• Title/Summary/Keyword: air mixing system

검색결과 293건 처리시간 0.029초

Examination of 2-Fluid Nozzle and 3-Fluid Nozzle for Fuel Reformer of 5 kW SOFC System (5 kW급 SOFC 시스템의 연료 개질기를 위한 2-유체 노즐과 3-유체 노즐의 검토)

  • Kwon, Hwa-Kil;Lee, Chi-Young;Lee, Sang-Yong
    • Journal of ILASS-Korea
    • /
    • 제13권1호
    • /
    • pp.16-21
    • /
    • 2008
  • In the present study, the 2-fluid nozzle and 3-fluid nozzle to atomize the diesel and water with air for the fuel reformer of SOFC system were experimentally examined. In the 2-fluid nozzle, the diesel and water were alternately atomized due to bislug flow pattern, and it implies that the mixing of both liquids strongly affects the atomization pattern. On the other hand, in the 3-fluid nozzle, the diesel and water were atomized simultaneously due to the separated injection channels without mixing problem. Therefore, compared to the 2-fluid nozzle, the 3-fluid nozzle is suitable for the stable operation of the fuel reformer. In case of the 3-fluid nozzle, Type A where the air was supplied through the central channel was the most efficient.

  • PDF

Mixing and Combustion Characteristics of a CNG and Air according to Fuel Supply Conditions in a DI Engine (직분식 엔진에서 연료공급 조건에 따른 CNG와 공기의 혼합 및 연소특성)

  • Kang, Jeong-Ho;Park, Jong-Sang;Yeom, Jeong-Kuk;Chung, Sung-Sik;Ha, Jong-Yul
    • Journal of ILASS-Korea
    • /
    • 제13권1호
    • /
    • pp.1-8
    • /
    • 2008
  • It was investigated how fuel injection timing - early injection and later injection - in conjunction with throttle open rate effect the fuel-air mixing characteristics, Engine power, combustion stability and emission characteristics on a DI CNG spark Engine and control system that had been modified and designed according to the author's original idea. It was verified that the combustion characteristics were changed according to fuel injection timings and Engine conditions determined by different throttle open rates and rpm. It was found that the combustion characteristics greatly improved at the complete open throttle rate with an early injection timing and at the part throttle rate with a late injection timing. Combustion duration was governed by flame propagation duration in a late injection timing and by an early flame development duration in an early injection timing. As the result, we discovered that combustion duration is shortened, lean limit is improved, air-fuel mixing conditions controlled, and emissions reduced through control of fuel injection timing according to change of the throttle open rate.

  • PDF

A PID Control of Supply Duct Outlet Air Temperature in Personal Environment Module

  • Park, Young-Chil
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권2호
    • /
    • pp.82-90
    • /
    • 2003
  • The work presented here is a design and an implementation of PID control system to regulate a supply duct outlet air temperature in PEM (Personal Environment Module). In PEM, the air is heated to the required temperature while it flows through the supply duct without any mixing chamber. This makes the control of air temperature in PEM difficult. A simulation is done first to understand the relationship between a temperature distribution in working area, flow rate and the outlet air temperature of PEM. Then a linear dynamic model of heating process in PEM is derived. P, PD and PID type control systems, to provide the rapid response without overshoot and saturation in heater command voltage, are designed using a linear model obtained. Experimentally obtained data shows that the control system satisfies the design criteria and works properly in controlling the supply duct outlet air temperature.

Impact of Different Meteorological Initializations on WRF Simulation During the KORUS-AQ Campaign (KORUS-AQ 기간 동안 초기 입력 자료에 따른 WRF 기상장 모의 결과 비교)

  • Mun, Jeonghyeok;Jeon, Wonbae;Lee, Hwa Woon
    • Journal of Environmental Science International
    • /
    • 제29권1호
    • /
    • pp.33-44
    • /
    • 2020
  • Recently, a variety of modeling studies have been conducted to examine the air quality over South Korea during the Korea - United States Air Quality (KORUS-AQ) campaign period (May 1 to June 10, 2016). This study investigates the impact of different meteorological initializations on atmospheric modeling results. We conduct several simulations during the KORUS-AQ period using the Weather Research and Forecasting (WRF) model with two different initial datasets, which is FNL of NCEP and ERA5 of ECMWF. Comparing the raw initial data, ERA5 showed better accuracy in the temperature, wind speed, and mixing ratio fields than those of NCEP-FNL. On the other hand, the results of WRF simulations with ERA5 showed better accuracy in the simulated temperature and mixing ratio than those with FNL, except for wind speed. Comparing the nudging efficiency of temperature and wind speed fields, the grid nudging effect on the FNL simulation was larger than that on the ERA5 simulation, but the results of mixing ratio field was the opposite. Overall, WRF simulation with ERA5 data showed a better performance for temperature and mixing ratio simulations than that with FNL data. For wind speed simulation, however, WRF simulation with FNL data indicated more accurate results compared to that with ERA5 data.

Evaluation of Aisle Partition System's Thermal Performance in Large Data Centers for Superior Cooling Efficiency (데이터센터의 공조효율 향상을 위한 공조파티션시스템 성능평가에 관한 연구)

  • Cho, Jin-Kyun;Jeong, Cha-Su;Kim, Byung-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제22권4호
    • /
    • pp.205-212
    • /
    • 2010
  • In a typical data center, large numbers of IT sever racks are arranged multiple rows. IT environments, in which extensive electronic hardware is air-cooled, cooling system inefficiencies result when heated exhaust air from equipment prematurely mixes with chilled coolant air before it is used for cooling. Mixing of chilled air before its use with heated exhaust air results in significant cooling inefficiencies in many systems. Over temperatures may not only harm expensive electronic equipment but also interrupt critical and revenue generating services. Cool shield is a cost effective aisle partition system to contain the air in cold aisles and hot aisles of an IT server room. This paper focuses on the use of performance metrics for analyzing aisle partition system in data centers.

Analyses of Steady State Mixing Process of Two-Liquids Using Artificial Intelligence (인공지능을 이용한 이종액체 정상 상태 혼합의 혼합과정 해석)

  • KONG, DAEKYEONG;YUM, JUHO;CHO, GYEONGRAE;DOH, DEOGHEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • 제29권5호
    • /
    • pp.523-529
    • /
    • 2018
  • Two liquids which are generally used as fuels of rockets are mixed and their mixing process is quantitatively investigated by the use of particle image velocimetry (PIV). As working fluids for the liquid mixing, Dimethylfuran (DMF) and JetA1 oils have been used. Since the specific gravity of DMF is larger than that of JetA1 oil, the DMF oil has been set at the lower part of the JetA1 oil. For better visualization of the mixing process, Rhodamin B powder has been blended into the DMF oil. An agitator having 3 blades has been used for mixing the two liquids. For quantitative visualization, a LCD monitor has been used as a light source. A color camera, camcoder, has been used for recording the mixing process. The images captured by the camcoder have been digitized into three color components, R, G, and B. The color intensities of R, G, and B have been used as the inputs of the neural network of which hidden layer has 20 neurons. Color-to-concentration calibration has been performed before commencing the main experiments. Once this calibration is completed, the temporal changes of the concentration of the DMF has been quantitatively analyzed by using the constructed measurement system.

Analysis of Air Distribution in the Windbox System of the Utility Boiler (보일러 Windbox내 공기공급 계통의 유량분포 해석)

  • Park, Ho-Young;Kim, Sung-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제20권9호
    • /
    • pp.581-589
    • /
    • 2008
  • The pulverized coal combustion behavior in the utility boiler is very complex since so many physical and chemical processes happen in it, simultaneously. The mixing of pulverized coal with combustion air plays an important role in achieving the efficient combustion and stable boiler operation. The distribution of combustion air supplied to the furnace through the windbox damper system has not been clearly known since the individual measurements of air flow for each air nozzle were not possible, yet. The present study describes the CFD modelling of windbox damper system and aims to obtain the air flow rates and pressure loss coefficients across the present five damper systems, respectively. The one dimensional flow network model has been also established to get air flow distributions across the windbox damper, and applied to the actual plant operation condition. Compared with the designed air flow distribution, the modelled one gives a reasonable agreement. For the actual plant operation, the predicted air flow distribution at each air nozzle is differed with the designed data and strongly affected by the individual opening angle.

On the Behavior of Liquid Droplets Depending upon ALR in Two-phase Internal Mixing Nozzle Jet (2상 내부 혼합형 노즐분사에서 ALR 변화에 따른 액적의 거동)

  • Kim Kyu Chul;Namkung Jung Hwan;Lee Sang Jin;Rho Byung Joon
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.385-388
    • /
    • 2002
  • The researches of a two-phase atomizers have been carried out in the field of automotive and aerospace industries in order to improve the atomization performance of the liquid droplets ejecting from these nozzles. The smaller droplets have the advantages of the reduction of environmental pollution matter and effective use of energy through the improvement of heat and mass transfer efficiency. Thus, to propose the basic information of two-phase flow, an internal mixing atomizer was designed, its shape factor was 0.6 and the liquid feeding hole was positioned at the center of the mixing tube which was used to mix the air and liquid. The experimental work was performed in the field after the nozzle exit orifice. The measurement of the liquid droplets was made by PDPA system. This system can measure the velocity and size of the droplets simultaneously. The number of the droplets used in this calculation was set to 10,000. The flow patterns were regulated by ALR (Air to Liquid mass Ratio). ALR was varied from 0.1024 to 0.3238 depending on the mass flow rate of the air. The analysis of sampling data was mainly focused on the spray characteristics such as flow characteristics distributions, half-width of spray, RMS, and turbulent kinetic energy with ALR.

  • PDF

Study on Exhaust Air Heat Transfer Characteristics of Heat Exchange System for White Smoke Reduction (백연 저감을 위한 열교환 시스템의 배기 열전달 특성에 관한 연구)

  • Wang, Zhen-Huan;Chun, Chong-Keun;Kwon, Young-Chul
    • Journal of the Korean Society of Mechanical Technology
    • /
    • 제20권6호
    • /
    • pp.739-744
    • /
    • 2018
  • In this study, effects of reducing white smoke at a heat exchange system for white smoke reduction were studied in the winter season. For this purpose, the heat transfer processes on the exhaust air were investigated by Solidworks. Five wave heat exchangers of air-to-air and air-to-water type were applied for the exhaust air heat recovery. The analytical condition of the exhaust air was fixed and the computational analysis was performed according to the change of SA(supply air) inlet velocities. In order to evaluate the performance of the heat exchange system for white smoke reduction, W(water)/SA recovered capacities and the temperature/absolute humidity reduction rate were calculated. As SA inlet velocity increased, the exit temperature and absolute humidity of the mixing zone were reduced by up to about $40^{\circ}C$ and 0.12kg/kg respectively. Also, W/SA recovered capacities increased linearly up to about 35%.

An Emission Characteristics of a Controlled Auto-Ignition Gasoline Engine (제어자발화 가솔린기관의 배기 특성)

  • Kim, H.S.
    • Journal of Power System Engineering
    • /
    • 제13권3호
    • /
    • pp.5-10
    • /
    • 2009
  • This work deals with a controlled auto-ignition (CAI) single cylinder gasoline engine, focusing on the extension of operating conditions. The fuel is injected indirectly into electrically heated inlet air flow. In order to keep a homogeneous air-fuel mixing, the fuel injector is cooled by the water of a specially designed coolant passage. The engine emission characteristics were investigated under the wide range of operating conditions such as 32 to 63 in the air-fuel ratio, 1000 to 1800 rpm in the engine speed, and 150 to $180^{\circ}C$ in the inlet air temperature. The ultra lean-burn can be achieved by the auto-ignition of gasoline fuel due to the heated inlet air in the compression ignition gasoline engine. It is confirmed that the emission concentrations of carbon monoxide, hydrocarbons and nitrogen oxide can be significantly reduced by CAI combustion compared with the combustion of a conventional spark ignition engine.

  • PDF