Effects of Leaf Loading Quantity and Circulating Air Volume on the Physical and Chemical Characteristics during Curing in Flue-cured Tobacco Leaves. (열풍건조시 적입 및 송풍량에 따른 황색종 연초엽의 이화학성 변화)

  • 석영선;노재영
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.14 no.1
    • /
    • pp.48-56
    • /
    • 1992
  • This studies were carried out to investigate the effects of leaf loading quantity and circulating air volume during bulk curing on the variation of physical and chemical characteristics in flue-cured tobacco. The results are as follows : 1. The content of sugar in cured leaves was decreased with more circulating air volume and leaf loading quantity at bulk curing. 2. Total nitrogen and protein nitrogen were decreased with less circulating air volume and more leaf loading quantity, while amino nitrogen was increased. 3. The contents of linolenic acid and linoleic acid were increased with more leaf loading quantity and oxalic acid and citric acid had a tendency of being increased in case of high circulating air volume. 4. In general, major aromatic compounds were increased through flue-curing. Relatively high content of solanone in case of lower air volume and less leaf loading were observed, while megastig matrienone was increased when leaf loading was small. 5. The more circulation air volume with leaf loading quantity caused lowering equilibrium moisture content and higher shatter index, which resulted in poor quality of cured leaves based on quality index, nitrogen number, taste index phillips index, and sugar-nicotine ratio.

  • PDF

Evaluation of Air Ion According to Vegetation Types in Valleys and Slopes - Focused on Tangeumdae Park in ChungJu - (계곡·사면부의 식생유형에 따른 공기이온 평가 - 충주시 탄금대 공원을 대상으로 -)

  • Yoon, Young-Han;Lee, Sang-Hoon;Kim, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.29 no.5
    • /
    • pp.519-529
    • /
    • 2020
  • The purpose of this study was to provide basic health care data for the climate aspects of park re-cultivation by evaluating air ions according to the type of vegetation in the valley and upper slopes of the mountain park. Simple negative or positive air ions were expected to show the same tendencies, so they were analyzed in terms of correcting the air ion index. By analyzing the air ions according to the topography, it was found that valley > slope in terms of the air ion index. When analyzing air ions according to tree species, we found that evergreen conifers in the valley > the deciduous broad-leaved trees in the valley > the evergreen conifers in the slope = the deciduous broad-leaved trees in the slope. For DBH(Diameter at breast height), the valley large pole > slope large pole > slope medium hard wood, while crown density was analyzed as valley dense > slope dense> valley proper > slope proper. Layered structure analysis showed that the multi-layer structure of the valley > multi-layer structure of the slope = the single-layer structure of the valley > the single-layer structure of the slope. The correlation coefficient was determined according to vegetation type and air ion index in the order of DBH > crown density > layer structure > geomorphic structure. In this study, limits exist except for ridge line, valley, and slopes in urban mountain parks. Therefore, analysis should be made considering both topographical structure and various vegetation types in future studies of air ions.

Feasibility Study for the Location of Air Quality Monitoring Network in Daegu Area (대구지역 대기오염자동측정망 위치의 타당성 분석)

  • Choi, Sung-Woo;Lee, Jung-Beom
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.81-91
    • /
    • 2011
  • Air quality monitoring networks are very important facilities to manage urban air pollution control and to set up an environmental policy. Since air quality monitoring network of Daegu was allocated from 1980s to mid-90s, there is need to reevaluate it and relocated its site. This study was evaluated the position of Daegu air quality monitoring station by unit environmental sensitivity index, grid emission rate, CAI (Comprehensive Air-quality Index) point. The investigation domain covered an area of 16 $\times$ 24 km centered at the metropolitan area of Daegu with grid spacing of 2 km. The location of alternative air quality monitoring networks was selected through optimization and quintiles analysis of total score. The result showed that all things considered, new air quality monitoring network need to install grid numbers 10, 28, 36, 37, 46. We also recommand three scenarios of alternative air quality monitoring network when considering unit environmental sensitivity index, emission rate and CAI point.

Air Pollution Prediction Model Using Artificial Neural Network And Fuzzy Theory

  • Baatarchuluun, Khaltar;Sung, Young-Suk;Lee, Malrey
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.3
    • /
    • pp.149-155
    • /
    • 2020
  • Air pollution is a problem of environmental health risk in big cities. Recently, researchers have proposed using various artificial intelligence technologies to predict air pollution. The proposed model is Cooperative of Artificial Neural Network (ANN) and Fuzzy Inference System (FIS), to predict air pollution of Korean cities using Python. Data air pollutant variables were collected and the Air Korean Web site air quality index was downloaded. This paper's aim was to predict on the health risks and the very unhealthy values of air pollution. We have predicted the air pollution of the environment based on the air quality index. According to the results of the experiment, our model was able to predict a very unhealthy value.

Comparison of Indoor Thermal Environments in Winter depending on Supply Vent Configurations (급기구 형상에 따른 겨울철 실내 온열환경의 비교)

  • Han, Hwa-Taik;Jeong, Young-Kyun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.970-975
    • /
    • 2008
  • This study considers indoor thermal comfort in an ondol space by supply vent configurations to prevent cold draft in winter. A specially-designed vent cap has been investigated in comparison with a round pan-type vent and a simple opening without a cap. Numerical simulations have been conducted using CFD to analyze thermal comfort indices such as Predicted Mean Vote (PMV) and Effective Draft Temperature (EDT) as well as air distribution index i.e. Air Diffusion Performance Index (ADPI). Results show the new vent cap provides improved thermal comfort conditions especially near ondol heated floor, as the cold outdoor air spreads upwards along the vertical wall before reaching occupant region near floor. This paper includes discussions on the flow and comfort distributions created by the thermal jets from the vents.

  • PDF

Performance Improvement of Air Conditioner Network System using Wireless Sensors Through System Performance Index and Dynamic Power Distribution Control (시스템 성능 지수 및 동적 전력분산 제어를 통한 무선센서를 이용한 에어컨 네트워크 시스템의 성능 개선)

  • Choi, Ho-seek;Kwon, Woo-hyen;Yoon, Byung-keun
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.64-70
    • /
    • 2019
  • Wireless sensors have been developed in numerous ways for enhancing the convenience of installation, management and maintenance of sensors. Energy harvesting wireless sensors, which can collect energy from the external environment for permanent usage without the need of recharging and exchanging batteries, have been developed and employed used in Internet of Things and at various industrial sites. Energy harvesting wireless sensors are significantly affected by the sensor lifespan to sudden variation in the external environment. Furthermore, reduction in the sensor operating timespan can greatly affect the characteristics of the devices connected through a network. In this paper, a system performance index is proposed that can comprehensively evaluate the lifespan of a solar cell wireless sensor, determine the characteristics of devices connected to the associated network, and recommend dynamic power distribution control for improving the system performance index. Improvement in the system performance index was verified by applying the proposed dynamic power distribution control to an air conditioner network system using a solar cell wireless sensor. Obtained results corroborate that the dynamic power distribution control can extend the lifespan of the incorporated wireless sensor and reduce the air conditioner's power consumption.

Physicochemical Properties of Soybean Curd Residue Powder by Different Soybean and Drying Methods (콩의 종류와 건조 방법에 따른 비지 분말의 이화학적 특성)

  • Eun Ji Kim;Hee Nam Jung
    • Journal of the Korean Society of Food Culture
    • /
    • v.38 no.5
    • /
    • pp.356-364
    • /
    • 2023
  • This study compared the physicochemical properties of soybean curd residue and black soybean curd residue produced by hot air-drying and freeze-drying. Regardless of drying method, the crude protein, crude ash, crude fiber contents, pH, L, a, b color values and water soluble index were higher in soybean curd residue, whereas total polyphenol contents and antioxidant activity were higher in black soybean curd residue. Significant differences in water absorption index, oil absorption capacity and emulsion activity were observed between soybean curd residue and black soybean curd residue in freeze-drying. On the other hand, the emulsion stability was not significant difference in both hot-air drying and freeze-drying. The crude protein and crude fiber contents of soybean curd residue were not significant difference between hot-air drying and freeze-drying. Freeze-drying resulted in higher crude ash contents, pH, water absorption index, water soluble index, oil absorption capacity, emulsion activity and emulsion stability than hot-air drying. Hot-air drying have caused significantly higher water contents, water activity, total polyphenol contents and antioxidant activity in soybean curd residue than freeze-drying. In conclusion, soybean type and drying methods affect the physicochemical and quality characteristics of soybean curd residue, which could be important factors in the manufacture of processed foods.

Research for Lateral Penumbra and Dose Distribution When Air Gap Changing in Proton Therapy Case (양성자치료시 Air Gap 변화에 따른 Lateral Penumbra와 선량분포 변화에 대한 비교 및 연구)

  • Kim, Jae-Won;Sim, Jin-Seob;Jang, Yo-Jong;Kang, Dong-Yun;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.47-51
    • /
    • 2010
  • Purpose: In the treatment of high-energy protons Air gap (the distance between the patient and the exit Beam) Lateral Penumbra of the changes to the increase in the radiation fields can form unnecessary and Increase the maximum dose at the site of treatment and reduced the minimum dose homogeneity of dose distributions can decline. Air gap due to this change in dose distribution compared to investigate studied. Materials and Methods: Received proton therapy at our institution Lung, Liver patients were selected and the size of six other Air gap in Field A and Field B 2, 4, 6, 8, 10 cm Proton external beam planning system by setting up a treatment plan established. Air gap according to the Lateral Penumbra area and DVH (Dose Volume Histogram) to compare the maximum dose and minimum dose of PCTV areas were compared. In addition, the dose homogeneity within PCTV Homogeneity index to know the value and compared. Results: Air gap (2, 4, 6, 8, 10 cm) at each change in field size were analyzed according to the Lateral Penumbra region Field A Change in the Air gap 2~10 cm by 1.36~1.75 cm, the average continuously increased about 28.7% and Field B Change in the Air gap 2~10 cm by 1.36~1.75 cm, the average continuously increased about 31.6%. The result of DVH analysis for relative dose of the maximum dose According to Air gap 2~10 cm is the mean average of 110.3% from 108.1% to a sustained increased by approximately 2.03% and The average relative dose of minimum dose is the mean average of 93.9% percent to 90.8 percent from the continuous decrease of about 3.31 percent. The result of Homogeneity index value to the according to Air gap 2~10 cm is the 2-fold increase from 1.09 to 2.6. Conclusion: In proton therapy case, we can see the increasing of lateral penumbra area when airgap getting increase. And increasing of Dmax and decreasing Dmin in the field are making increase homogeneity index, So we can realize there are not so good homogeneity in the PCTV. Therefore we should try to minimize air gap in proton therapy case.

  • PDF

A Study on the Characteristics of Perceived Temperature over the Korean Peninsula During 2007 Summer (한반도 2007년 여름철 인지온도 특성 연구)

  • Byon, Jae-Young;Kim, Jeong-Sik;Kim, Ji-Young;Choi, Byoung-Cheol;Choi, Young-Jean;Graetz, Angelika
    • Atmosphere
    • /
    • v.18 no.2
    • /
    • pp.137-146
    • /
    • 2008
  • This study examines one thermal index, perceived temperature (PT), over the Korean Peninsula during 2007 summer. Heat/cold stress has been described using air temperature and humidity for warm seasons and air temperature and wind velocity in the cold conditions, while PT is based on a heat budget model of the human body that considers air temperature, humidity, wind velocity and radiation effect regardless of climates, regions and seasons. PT is higher about $4-5^{\circ}C$ than air temperature in the summer. Humidity increases PT, while wind tends to reduces PT possibly by evaporation of water vapor. The geographical distribution of summer PT indicates that the lowest PT happened in the east central region, with the appearance of the highest PT in the inland of southern region in Korea. Although the latitudinal trend shows that PT decreases northward, inland PT is higher than that of coastal region. Compared to the heat index or the discomfort index that considers air temperature and humidity, PT represents distinctive regional characteristics of thermal comfort. The distribution of PT shows that it may be a useful thermal index for the assessment of thermal comfort or stress region in the Korean Peninsula.