• Title/Summary/Keyword: air foam

Search Result 234, Processing Time 0.024 seconds

Numerical study of steel sandwich plates with RPF and VR cores materials under free air blast loads

  • Rashad, Mohamed;Yang, T.Y.
    • Steel and Composite Structures
    • /
    • v.27 no.6
    • /
    • pp.717-725
    • /
    • 2018
  • One of the most important design criteria in military tunnels and armoured doors is to resist the blast loads with minimum structural weight. This can be achieved by using steel sandwich panels. In this paper, the nonlinear behaviour of steel sandwich panels, with different core materials: (1) Hollow (no core material); (2) Rigid Polyurethane Foam (RPF); and (3) Vulcanized Rubber (VR) under free air blast loads, was investigated using detailed 3D nonlinear finite element models in Ansys Autodyn. The accuracy of the finite element model proposed was verified using available experimental test data of a similar steel sandwich panel tested. The results show the developed finite element model can be reliably used to simulate the nonlinear behaviour of the steel sandwich panels under free air blast loads. The verified finite element model was used to examine the different parameters of the steel sandwich panel with different core materials. The result shows that the sandwich panel with RPF core material is more efficient than the VR sandwich panel followed by the Hollow sandwich panels. The average maximum displacement of RPF sandwich panel under different ranges of TNT charge (1 kg to 10 kg at a standoff distance of 1 m) is 49% and 53% less than the VR and Hollow sandwich panels, respectively. Detailed empirical design equations were provided to quantify the maximum deformation of the steel sandwich panels with different core materials and core thickness under a different range of blast loads. The developed equations can be used as a guide for engineer to design steel sandwich panels with RPF and VR core material under a different range of free air blast loads.

An Experimental Study on a Discharge Pressure, Flow Rate and Foam Discharge Concentration through the Nozzle According to the Foam Suction Nipple Diameter (노즐 구경에 따른 포 수용액의 압력과 유량 및 농도 변화에 관한 실험적 연구)

  • Jang, Kyung-Nam;Lee, Maing-Ro;Park, Bong-Rae;Yun, Ki-Jo;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.84-91
    • /
    • 2015
  • The purpose of this study is to suggest the reasonable model of the caliber in suction nozzle, the pressure of suction nozzle, and the flow rate about foam system of line proportioner type using in the pumpcar. To test this, the experimental study was accomplished on the ground of the standards for the Performance Certification and Product Inspection of Foam Fire-extinguishing Chemical Mixing Machine. Aqueous Film Forming Foam in 3% and pipe type air foam nozzle with line proportioner FE 40 type were used. Test result showed that the pressure of suction nozzle within the limits between 0.25 MPa and 0.35 MPa was appropriate when the caliber in suction nozzle is 4 mm. Also, the pressure of suction nozzle within the limits between 0.45 MPa and 0.60 MPa was appropriate in the higher pressure than 4 mm when the caliber in suction nozzle is 5 mm.

A Study on the Effectiveness of Hand Sanitizer compared to Conventional Ultrasound Gel during Ultrasound Examination (초음파검사 시 기존 초음파젤과 비교한 손소독제의 유용성 연구)

  • Sun-Youl Seo;Jin-Ok Lee;Young-Ran Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.957-964
    • /
    • 2023
  • This study focused on hand sanitizer as a medium that can replace ultrasonic gel, which is vulnerable to contamination by bacteria that reside on the hand. Hand sanitizer produces a strong sterilization effect from germs resident on the hands through different sterilization principles depending on the ingredients. Select products of gel type, cream type, and foam type, except for liquid type with low viscosity, and ultrasonically apply one 62% ethanol gel type and one cream type, one benzalkonium chloride 0.066% cream type and one foam type, respectively. Using ATS-539 as a medium, image evaluation was performed on the axial and lateral resolution and penetration depth, and the presence or absence of an air layer between the probe and the phantom. As a result, in the evaluation of the axial and lateral resolution and the depth of penetration, all four experimental groups met the evaluation criteria. However, in the case of the foam type, although it was suitable for the evaluation criteria of resolution and penetration depth, dark shadows appeared on both sides except for the center of observation during image evaluation. Through this experiment, it was possible to confirm the possibility that the remaining three types of hand sanitizers except the foam type could replace the ultrasonic gel.

Compost of Swine Manure Slurry Using the Thermophilic Aerobic Oxidation (TAO) Syst

  • Lee, W.I.;Tsujii, H.;Lee, M.G.;Cha, G.C.;Chung, J.C.
    • Journal of Animal Environmental Science
    • /
    • v.10 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • A field-scale(8.6${\times}$2.5${\times}$2.4 m) and pilot-scale(1.39${\times}$0.89${\times}$0.89 m) thermophilic aerobic oxidation (TAO) units were installed to investigate the volume reduction efficiency of slurry, by varying the aeration and treatment temperature of swine manure, and the collected liquid was evaluated as a liquid fertilizer. In the field-scale unit, the aeration level and numbers of foam breakers made different effects on the slurry volume and temperature in the TAO system. The experiments were peformed for three cases, using different levels of aeration and numbers of foam breakers: Treat-A (aeration rate; 120 ㎥ air/hr using 2 air pumps and 2 foam breakers), Treat-B (aeration rate; 180 ㎥ air/hr using 3 air pumps and 3 foam breakers) and Treat-C (aeration rate; 180 ㎥ air/hr using 3 air pumps and 4 foam breakers). With the same input volume (5 ㎥/day) of swine manure slurry, the resulting liquid levels, temperatures and evaporation rates were 50∼100 cm, 31∼$64^{\circ}C$ and 55 $\ell/m^2$/day for Treat-A; 40∼90 cm, 29∼$52^{\circ}C$ and 75 $\ell/m^2$/day for Treat-B; and 40∼70 cm, 45∼$54^{\circ}C$ and 120.0 $\ell/m^2$/day for Treat-C. In the pilot-scale unit, semi-continuous flow of swine manure slurry was introduced. 50 $\ell$ every 2hr(T-1), 50 $\ell$ every 3hr(T-2), 40 $\ell$ every 2hr (T-3) and 60 $\ell$ every 4hr (T-4) within 24 hours, in order to find the maximum slurry volume reduction conditions.

  • PDF

해수의 포말생성 영향 인자 고찰

  • Lee, Ju-Hwa;Sin, Jeong-Sik;Seo, Geun-Hak
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.371-373
    • /
    • 2003
  • In experiments on sea water, it took longer to reach almost steady state and the foam heights were increased as increasing initial protein concentration. The foam height was increased with the decrease of the pore size. G3, G4, and air stone were similar. It was increased with the increase in the superficial air velocity (SAV) and it was efficient when the SAV is $0.7{\sim}0.8\;cm/sec$. The optimum pH condition is weak acid and weak base region. The influence of salts, $NaHCO_3$, was not that significant due to NaCl in the sea water.

  • PDF

NUMERICAL SIMULATION ON CONTROL OF HUMIDITY AND AIR TEMPERATURE IN THE GRADIENT BIOME (환경경도 바이옴 내의 온도 및 습도 제어 시뮬레이션)

  • Jeong, S.M.
    • Journal of computational fluids engineering
    • /
    • v.21 no.2
    • /
    • pp.32-39
    • /
    • 2016
  • The Gradient Biome is a unique and large greenhouse(length 200 m, width 50 m, height:40 m) in which the elements of the weather, such as temperature and humidity, are controlled and reproduced in such a way as to create a continuous gradient from the tropical to frigid zones along specified longitudinal or transvers lines on the earth. One of the main purposes of the Gradient Biome is to observe the possible responses of the ecosystems (mainly plants), which are to be corresponding to each test climate and be introduced in the Biome, to the expected global warming. As one of the expected responses is the shift of the ecosystem(s) toward the region of suitable environment, there should be no artificial obstacles, which can prevent the shift, inside the facility. However, it is important but not so easy to find the ways of how the temperature and humidity in the Biome could be reproduced since the environmental variables tends to be homogeneous. In this paper, numerical simulations were carried out to find the effective control methods for air temperature and humidity inside the real scale Biome. One of the contributed solvers of OpenFOAM, which is an open source physics simulation code, was modified and used for the simulations.

Comparative Effects and Ranks of Repositioning for Pressure Ulcer Prevention in Adults: A Network Meta-analysis (욕창예방을 위한 체위변경 중재 효과의 비교순위: 네트워크 메타분석)

  • Ko, Ji Woon
    • Journal of muscle and joint health
    • /
    • v.29 no.1
    • /
    • pp.18-27
    • /
    • 2022
  • Purpose: A network meta-analysis was conducted to assess the comparative effects and ranks of repositioning for pressure ulcer prevention in adults. Methods: A network meta-analysis was performed in a frequency method, using the "netmeta" package of R software version 4.1. The effects of repositioning intervention were confirmed by the odds ratio. The comparative ranking of the repositioning effects was confirmed using the cumulative probability (P-score). Results: Seven intervention studies were included in this study. Based on the P-score, the use of the repositioning system was ranked as the most effective among all interventions (P-score 78.7%). Next was 3~4-hour repositioning combined with memory foam mattress use (P-score 77.2%), use of wearable sensor (P-Score 61.4%), 2-hour repositioning combined with memory foam mattress use (P-score 59.1%), 2-hour repositioning combined with powered air pressure redistribution mattress use (P-score 18.0%), and 4-hour repositioning combined with powered air pressure redistribution mattress use (P-score 18.0%). Conclusion: This study provides information on the relative comparative value of various repositioning interventions to prevent pressure ulcers using network meta-analysis. This is expected to be useful for nurses' decision-making when applying repositioning interventions in clinical practice

A Study On The Development Of An Automatic Fire Extinguishing System For The Engine Compartment Use Of Automobiles (자동차 엔진 화재용 자동 소화 시스템 개발에 관한 연구)

  • Lim, Sung-Muk;Jung, Ki-Chang;Kim, Hong;Kang, Young-Goo;Lee, Chang-Sub
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.57-61
    • /
    • 1996
  • Our goal was to make a cost-effective automatic fire extinguishing system for the engine compartment use of automobiles. We designed this system for the engine compartment. This system consists of 1)foam extinguisher, 2)four nozzles, 3)a pipe arrangement, and 4)an extinguishing device which is equipped with a glass bulb as detector. First and foremost, the extinguishing device was carefully designed to keep the system cost to a minimum. Second, a AFFF foam extinguisher was used because no other fire-fighting agents proved effective against fire in the engine compartment. The AFFF(Aqueous Film Forming Foam) agent which was used in the extinguisher is the 3M company's Light Water. We sought, however, to make other foams by using Halon 1301 and Halon alternatives such as HCFC Blend A, HFC-227ea. We selected these alternatives instead of air in order to raise the expansion ratio of the AFFF agent. By these means we discovered that it is possible to increase the expansion ration of the AFFF agent up to 44:1. We then demonstrated that our automatic fire extinguishing system is the most effective and lowest cost-system yet devised for passenger cars.

  • PDF