• 제목/요약/키워드: air filter

검색결과 1,003건 처리시간 0.023초

A Novel Range Estimator for Surface to Air Missile with Closing Velocity Measurements

  • Ra, W.S.;Whang, I.H.;Lee, J.I.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1822-1825
    • /
    • 2003
  • A practical range estimator based on the robust Kalman filter is proposed to solve the range estimation problem for surface to air missile(SAM) homing guidance. Apart from the previous works based on the extended Kalman filter(EKF) with bearing only measurement, the proposed scheme makes use of line-of-sight(LOS) rate to ensure the fast convergency at long-range. In this reason, the robust Kalman filter is considered to deal with LOS rate measurement error. The recursive linear structure of proposed filter is easy to implement and make it possible to reduce computational burdens. Moreover, it shows good estimation performance without specific guidance law such as oscillation proportional navigation guidance(OPNG).

  • PDF

UHF대역 TV 튜너에 적용을 위한 가변형 대역통과필터 (SIP based Tunable BPF for UHF TV Tuner Applications)

  • 이태창;박재영
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.2127-2130
    • /
    • 2008
  • In this paper, a tunable bandpass filter with mutual inductive coupling circuits is newly designed and demonstrated for UHF TV tuner ranged from Ch.14(473MHz) to Ch.69(803MHz) applications. Conventional HF tuning circuit with an electromagnetic bandpass filter has several problems such as large size, high volume and high cost, since the electromagnetic filter is comprised of several passive components and air core inductors to be assembled and controlled manually. To address these obstacles, peaking chip inductor was newly applied for constructing the mutual inductive coupling circuit. The proposed circuit was newly and optimally designed, since the chip inductor showed lower components Q-value than the air core inductor. A varactor diode has been also used to fabricate the proposed tunable bandpass filter for RF tuning circuit. The fabricated tunable filter exhibited low insertion loss of approximately -3dB, high return loss of below -10dB, and large tuning bandwidth of 330MHz.

실험동물 사육실에서의 Exhaust Filter Unit의 악취제거성능에 관한 실험적 연구 (An Experimental Study on the Deodorization Performance of Exhaust Filter Unit in a Laboratory Animal Breeding Facility)

  • 권순욱;홍진관
    • 설비공학논문집
    • /
    • 제25권4호
    • /
    • pp.194-200
    • /
    • 2013
  • In this study, an exhaust filter unit for removing bad smells is designed and manufactured to understand the characteristics, damages, and effects on humans and animals of bad smell substances in laboratory animal breeding facilities. Using the exhaust filter unit, a deodorization performance test using ammonia gas, as a typical bad smell in an animal breeding room, was carried out for three types of activated and impregnated charcoal filters. The experimental results showed that the pressure loss of the HEPA and carbon filter was increased with flow rate and that the average deodorization performance for the case where an impregnated carbon filter was installed was a maximum value of between 93 and 96%, with various fractional flow rates ranging from 1,500 to $3,500m^3/h$ in a laboratory animal breeding room. The experimental results will also be used for the design and manufacture of a practical and efficient exhaust filter unit to cope with bad smell problems in animal breeding facilities.

Adsorption of volatile organic compounds using activated carbon fiber filter in the automobiles

  • Moon, Hyung Suk;Kim, In Soo;Kang, Sin Jae;Ryu, Seung Kon
    • Carbon letters
    • /
    • 제15권3호
    • /
    • pp.203-209
    • /
    • 2014
  • The adsorption of volatile organic compounds (VOCs) was carried out using an activated carbon fiber (ACF) filter in an automobile. The adsorption capacities of formaldehyde, toluene, and benzene on an ACF filter were far better than those of a polypropylene (PP) mat filter and combined (PP+activated carbon) mat filter by batch adsorption in a gas bag. In a continuous flow of air containing toluene vapor through an ACF packed bed, the breakpoint time was very long, the length of the unused bed was short, and sharp "S" -type breakthrough curve was plotted soon after breakpoint, showing a narrow mass transfer zone of toluene on the ACF. The adsorption amount of toluene on the ACF filter was proportional to the specific surface area of the ACF; however, the development of mesopores 2-5 nm in size on the ACF was very effective with regard to the adsorption of toluene. The ACF air clarifier filter is strongly recommended to remove VOCs in newly produced automobiles.

승용차용 정전 필터 내의 정전 섬유의 보유 하전 감쇄에 의한 미세 입자 포집효율 변화 (Charge Depletion Effect on Collection Efficiency of an Electret Cabin Air Filter for Submicron Particles)

  • 지준호;강석훈;황정호;배귀남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.71-76
    • /
    • 2001
  • An electret filter is composed of permanently charged electet fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using poly-disperse particles when submicron particles are loaded. Long-term experiments were conducted by applying different charging states, which are spray electrification and charge equilibrium by bipolar ionization. In order to investigate on the effect of particle loading in filter media, NaCl particles were generated from 0.1% and 1% solutions by an atomizer. In NaCl 0.1%, the collection efficiency of electret filter decreased and then did not change in equilibrium state. In the case of relative larger particles of NaCl 1%, collection efficiency for the equilibrium charged particles increases due to the particle loading on the filter fibers. Particles charged by spray electrification are small in collection efficiency after equilibrium state and increase of filter media's pressure drop was very low in comparison of the equilibrium charged particles.

  • PDF

Analysis of Air Discharge and Disused Air Filters in Radioisotope Production Facility

  • Kim, Sung Ho;Lee, Bu Hyung;Kwon, Soo Il;Kim, Jae Seok;Kim, Gi-sub;Park, Min Seok;Jung, Haijo
    • 한국의학물리학회지:의학물리
    • /
    • 제27권3호
    • /
    • pp.156-161
    • /
    • 2016
  • When air discharged from a radioisotope production facility is contaminated with radiation, the public may be exposed to radiation. The objective of this study is to manage such radiation exposure. We measured the airborne radioactivity concentration at a 30 MeV cyclotron radioisotope production facility to assess whether the exhaust gas was contaminated. Additionally, we investigted the radioactive contamination of the air filter for efficient air purification and radiation safety control. To measure the airborne radiation concentration, specimens were collected weekly for 4 h after the beginning of the radioisotope production. Regarding the air purifier, five specimens were collected at different positions of each filter-pre-filter, high-efficiency particulate air filter, and charcoal filter-installed in the cyclotron production room. The concentrations of F-18, I-123, I-131, and Tl-201 generated in the radioiodine production room were $13.5Bq/m^3$, $27.0Bq/m^3$, $0.10Bq/m^3$, and $11.5Bq/m^3$, respectively; the concentrations of F-18, I-123, and I-131 produced in the radioisotope production room were $0.05Bq/m^3$, $16.1Bq/m^3$, and $0.45Bq/m^3$, correspondingly; and those of F-18, I-123, I-131, and Tl-201 generated in the accelerator room were $2.07Bq/m^3$, $53.0Bq/m^3$, $0.37Bq/m^3$, and $0.15Bq/m^3$, respectively. The maximum radiation concentration of I-123 generated in the radioiodine production room was 1,820 Bq/g, which can be disposed after 2 days. The maximum radiation concentration of Tl-202 generated in the radioisotope production room was 205 Bq/g, and this isotope must be stored for 53 days. The I-123 generated in the radioiodine production room had a maximum concentration of 1,530 Bq/g and must be stored for 2 days. The maximum radiation concentration of Na-22 generated in the radioisotope production room was 0.18 Bq/g and this isotope must be disposed after 827 days. To manage the exhaust, the efficiency of air purification must be enhanced by selecting an air purifier with a long life and determining the appropriate replacement time by examining the differential pressure through systematic measurements of the airborne radiation contamination level.

이끼를 활용한 공기정화 시스템 개발 및 이끼별 공기정화 능력 평가 (Development of an air purification system using moss and evaluation of air purification capability for each moss)

  • 안도현;최현우;이종민;허성필
    • 한국산업정보학회논문지
    • /
    • 제27권3호
    • /
    • pp.21-28
    • /
    • 2022
  • 미세먼지는 대기를 타고 호흡기를 거쳐 폐 혹은 혈관에 침투한다. 최근 미세먼지 문제 때문에 국내에 공기청정기 수요도 급증하고 있다. 이끼는 가장 오래된 지상식물로 중금속과 미세먼지를 흡착하여 분해하는 성질을 가지고 있는 것으로 알려졌고 본 연구진은 이를 활용하여 화학적 필터를 대체할 수 있는 시스템에 대해 연구하였다. 이끼와 기존 화학적 필터(Hepa)의 미세먼지 감소 효과를 비교하기 위하여 1 m3의 큐브를 제작하고 통제된 환경하에서 미세먼지의 감소량을 비교하였다. 미세먼지 상황 하에서 우산 이끼 필터, 쥐꼬리 이끼 필터, 깃털 이끼 필터, 비단 이끼 필터 등을 삽입한 4가지 상황별로 각각 10회씩 총 40회의 실험을 진행하였으며 각각의 미세먼지 감소량을 비교한 결과 미세먼지 양과 30분후의 감소량의 차이는 모든 필터에서 모두 통계적으로 유의한 차이가 있었다. 하지만 필터별 차이는 확인 결과 미세먼지, 혼합 가스, CO2, O2 모두 필터별 간 통계적으로 유의한 차이가 없음을 확인하였다. 특히 기존에 알려진 이끼의 산소 발생의 효과는 거의 없었음을 확인하였다. 이 결과를 통해 이끼의 종류와 관계없이 미세먼지 감소는 효과가 있는 것을 확인하였고 향후 개선을 통해 기존 공기정화기의 화학 필터를 대체하거나 보조할 것으로 기대된다.

입자의 크기와 유속에 따른 섬유질 여과포에 의한 부유입자 제거 연구 (Removal of Aerosol Through Fibrous Filter as a Function of Particle Size and Velocity)

  • Sang Hoon Lee;Kwan Sik Chun;Hoo Keun Lee
    • Nuclear Engineering and Technology
    • /
    • 제16권1호
    • /
    • pp.29-35
    • /
    • 1984
  • 유리섬유 여과포에 의한 0.1~0.45$\mu\textrm{m}$ 크기의 DOP 부유입자의 제거효율시험을 1~10cm/sec의 유속범위에서 수행하였다. 섬유여과포에 의한 미세입자의 여과는 여과속도에 의하여 결정되는데, 최소제거 효율을 나타내는 DOP 입자의 크기는 여과속도가 증가함에 따라 감소한다. Kuwabara Cell Model과 Von Mises Transformation을 사용하여 유리섬유 여과포내에서 화산에 의한 입자 제거효율을 수치해석적으로 전개하여 구하였으며, 이 계산치는 실험치와 잘 일치하였다. 본 실험의 결과는 여과포의 입자제거효율을 예측하고 최적 운전조건을 추구하는데 기여할 수 있을 것이다.

  • PDF

절곡필터에서의 압력강하 및 유동특성에 관한 수치적 연구 (A Numerical Study on Pressure Drop and Flow Characteristics in Pleated Filters)

  • 이재헌;정상호;조상준;김광영
    • 설비공학논문집
    • /
    • 제3권3호
    • /
    • pp.176-185
    • /
    • 1991
  • Pressure drop and flow characteristics through a filter medium have been investigated numerically. A basic model similar to the filter employed in a hard disk drive was established so that the inflow velocity was 0.1 m/s and the box size was $40mm{\times}50mm{\times}30mm$. The filter medium specifications were 0.38mm of thickness, $1{\mu}m$ of fiber diameter, 0.05 of packing density. And the filter medium was pleated by 10 within the filter box. Twenty-one sets of calculation were performed with different inlet velocities, pleated numbers, and packing densities from the basic model. As the result, it was found that the velocity after filter medium had maximum value at the rear of the upstream pleated line, but had minimum value at the rear of the downstream pleated line. This made the velocity distribution have sinusoidal form immediately after the filter medium. As the inlet velocity increased, the pressure drop increased linearly. But as the packing density increased the pressure drop increased quadratically.

  • PDF