• Title/Summary/Keyword: air exposure time

Search Result 336, Processing Time 0.034 seconds

Application of Biomarkers for the Assessment of Carcinogen Exposure and Cancer Risk (발암물질 노출량 산출 및 암 위해성 평가에 있어서 Biomcrker의 활용)

  • 이병무
    • Environmental Mutagens and Carcinogens
    • /
    • v.19 no.2
    • /
    • pp.95-101
    • /
    • 1999
  • Risk Assessment is an important area in toxicology and the methodology for risk assessment has been developed. Mathematical models used for risk assessment include one-hit multi-hit, two-stage, probit logistic, multistage, and linearized multistage models. For the assessment of exposure dose, environmental monitoring has been applied, but it has limitation to accurately assess exposure level because the levels in the air, water, foods, and soil may vary depending on time of sampling. In addition, humans can be exposed to various sources of exposure and thus it will be impossible to estimate the total level of exposure in humans by environmental monitoring. To eliminate the limitation of environmental monitoring, a direct measurement of toxic materials or modified biomolecules (called biomarkers) associated with the exposure of toxic materials is needed. Here, scientific basis of biomarkers and future direction have been considered for the assessment of carcinogen exposure and cancer risk in humans.

  • PDF

Application of Indoor Air Modelling for Using Health Risk Assessment in Environmental Impact Assessment (환경영향평가에서 건강위해성평가 기법을 이용하기 위한 실내공기 모델링 적용)

  • Yang, Won-Ho;Son, Bu-Soon;Park, Jong-An;Kim, Im-Soon;Han, Sang-Wook
    • Journal of Environmental Impact Assessment
    • /
    • v.10 no.3
    • /
    • pp.211-221
    • /
    • 2001
  • Recognizing interaction between the environment and humans, the EIA(environmental impact assessment) movement has sought to promote more environmentally sound and informed decisions for the sake of human welfare. Therefore, most EIA programs require the consideration of human health impacts. Yet relatively few EIA documents adequately address those impacts. This study was carried out to investigate the role of EIA for reuniting the environment and human health, for preventing and reducing significant health risks, and for improving human health impact assessment by means of risk assessment. Risk assessment consists of 4 components; hazard identification, dose-response assessment, exposure assessment and risk characterization. Since most people spent their times in indoor, indoor air quality modelling can be used in exposure assessment and risk assessment. In this study, indoor $NO_2$ concentration and personal $NO_2$ exposure were estimated by Box Model using mass balance equation and time weighted average, respectively. The estimated indoor $NO_2$ concentration and the personal $NO_2$ exposure were compared by those measured, respectively. Subsequntly, health effect was assessed with these results. Consequently, exposure assessment and risk assessment using indoor air quality model may be considered to be applicable to EIA.

  • PDF

Comparison with decompression time and modes of air decompression tables in 5 countries (5개국 공기잠수감압표의 감압시간과 감압방법 비교)

  • Kang, Joonhyuk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.4
    • /
    • pp.445-453
    • /
    • 2016
  • Objectives: The objective of this study is to assess relative safety level of the decompression tables in Ministry of Employment and Labor Public Notice No. 2014-28 in comparison with overseas decompression tables. Methods: Decompression tables in the Public Notice No. 2014-28 were compared with examples from Japan, the USA, Canada, and France in terms of ascent rate, surface intervals after exceptional exposures, oxygen decompression and allowable partial pressure, depth limits in air diving, no-decompression limits, and decompression time and methods. Results: Public Notice No. 2014-28 does not include air diving depth limits, exceptional exposure limits, mandatory surface intervals after exceptional exposures, oxygen decompression, and surface decompression schedules. Its decompression time was found to be the shortest among the five decompression tables. Conclusions: Public Notice No. 2014-28 has the lowest safety level in comparison with overseas decompression tables. Deck decompression chambers are not applicable due to no regulations on surface interval and oxygen use in the chamber for decompression.

Effect of Ambient Air Pollution on Years of Life Lost from Deaths due to Injury in Seoul, South Korea (대기오염물질이 손상으로 인한 손실수명연수에 미치는 영향: 서울특별시를 중심으로)

  • Sun-Woo Kang;Subin Jeong;Hyewon Lee
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.3
    • /
    • pp.149-158
    • /
    • 2023
  • Background: Injury is one of the major health problems in South Korea. Few studies have evaluated both intentional and unintentional injury when investigating the association between exposure to air pollutants and injury. Objectives: We aimed to explore the association between short-term exposure to ambient air pollution and years of life lost (YLLs) due to injury. Methods: Data on daily YLLs for 2002~2019 were obtained from the the Death Statistics Database of the Korean National Statistical Office. This study estimated short-term exposure to particulate matter with an aerodynamic diameter of <10 ㎛ (PM10), particulate matter with an aerodynamic diameter of <2.5 ㎛ (PM2.5), sulfur dioxide (SO2), nitrogen dioxide (NO2), carbon monoxide (CO), and ozone (O3). This time series study was conducted using a generalized additive model (GAM) assuming a Gaussian distribution. We also evaluated a delayed effect of ambient air pollution by constructing a lag structure up to seven days. The best-fitting lag was selected based on smallest generalized cross validation (GCV) value. To explore effect modification by intentionality of injury (i.e., intentional injury [self-harm, assault] and unintentional injury), we conducted stratified subgroup analyses. Additionally, we stratified unintentional injury by mechanism (traffic accident, fall, etc.). Results: During the study period, the average daily YLLs due to injury was 307.5 years. In the intentional injury, YLLs due to self-harm and assault showed positive association with air pollutants. In the unintentional injury, YLLs due to fall, electric current, fire and poisoning showed positive association with air pollutants, whereas YLLs due to traffic accident, mechanical force and drowning/submersion showed negative associations with air pollutants. Conclusions: Injury is recognized as preventable, and effective strategies to create a safe society are important. Therefore, we need to establish strategies to prevent injury and consider air pollutants in this regard.

Quantitative Assessment Strategy for Determining the Exposures to Volatile Organic Chemicals in Chemistry Laboratories (화학실험실의 휘발성유기화합물 노출에 대한 정량적 평가전략)

  • Byun, Hyaejeong;Ryu, Kyongnam;Yoon, Chungsik;Park, Jeongim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.1
    • /
    • pp.11-24
    • /
    • 2011
  • Working in a research laboratory means exposure to a wide range of hazardous substances. Several studies indicated that laboratory workers, especially working with chemicals, might have an increased risk of certain cancers. However, exposure assessment data in laboratory settings are scarce. This study was performed to examine several approaches for quantitatively assessing the exposure levels to volatile organic compounds (VOCs) among workers in chemistry laboratories. The list of 10 target VOCs, including ethanol, acetone, 2-propanol, dichlormethane, tetrahydrofuran, benzene, toluene, n-hexane, ethyl acetate, chloroform, was determined through self-administered questionnaire for six chemistry research laboratories in a university, a government-funded research institute, or private labs. From September to December 2008, 84 air samples were collected (15 area samples, 27 personal time weighted samples, 42 personal task-basis short-term samples). Real time monitors with photo ionization detector were placed during the sampling periods. In this study, benzene was observed exceeding the action levels, although all the results were below the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV). From the air sampling results, we concluded that (1) chemicals emitted during experiments could directly affect to neighbor office areas (2) chemical exposures in research laboratories showed a wide range of concentrations depending on research activities (3) area samples tended to underestimate the exposures relative to personal samples. Still, further investigation, is necessary for developing exposure assessment strategies specific to laboratories with unique exposure profiles.

Review of Various Quantitative Methods to Measure Secondhand Smoke (간접흡연의 정량적 노출측정 방법의 고찰)

  • Lim, Soo-Gil;Kim, Joung-Yoon;Lim, Wan-Ryung;Sohn, Hong-Ji;Lee, Ki-Young
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.2
    • /
    • pp.100-115
    • /
    • 2009
  • Secondhand smoke (SHS) is one of major public health threats. Since secondhand smoke is complex mixture of toxic chemicals, there has been no standardized method to measure SHS quantitatively. The purpose of this manuscript was to review various quantitative methods to measure SHS. There are two different methods: air monitoring and biological monitoring. Air monitoring methods include exhaled carbon monoxide level, ambient fine particulates, nicotine and 3-ethenylpyridine. Measurement of fine particulates has been utilized due to presence of real-time monitor, while fine particulates can have multiple indoor sources other than SHS. Ambient nicotine and 3-EP are more specific to SHS, although there is no real-time monitor for these chemicals. Biological monitoring methods include nicotine in hair, cotinine in urine, NNK in urine and DNA adducts. Nicotine in hair can provide chronic internal dose, while cotinine in urine can provide acute dose. Since biological monitoring can provide total internal dose, identification of specific exposure source may be difficult. NNK in urine can indicate carcinogenicity of the SHS exposure. DNA adducts can provide overall cancer causing exposure, but not specific to SHS. While there are many quantitative methods to measure SHS, selection of appropriate method should be based on purposes of assessment. Application of accurate and appropriate exposure assessment method is important for understanding health effects and establishing appropriate control measures.

A Critical Evaluation of DNA Adducts as Biological Markers for Human Exposure to Polycyclic Aromatic Compounds

  • Godschalk, Roger W.L.;Van Schooten, Frederik-Jan;Bartsch, Helmut
    • BMB Reports
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2003
  • The causative role of polycyclic aromatic hydrocarbons (PAH) in human carcinogenesis is undisputed. Measurements of PAH-DNA adduct levels in easily accessible white blood cells therefore represent useful early endpoints in exposure intervention of chemoprevention studies. The successful applicability of DNA adducts as early endpoints depends on several criteria:i.adduct levels in easily accessible surrogate tissues should reflect adduct levels in target-tissues, ii. toxicokinetics and the temporal relevance should be properly defined.iii. sources of inter- and intra-individual variability must be known and controllable, and finally iv. adduct analyses must have advantages as compared to other markers of PAH-exposure. In general, higher DNA adduct levels or a higher proportion of subjects with detectable DNA adduct levels were found in exposed individuals as compared with non-exposed subjects, but saturation may occur at high exposures. Furthermore, DNA adduct levels varied according to changes in exposure, for example smoking cessation resulted in lower DNA adduct levels and adduct levels paralleled seasonal variations of air-pollution. Intra-individual variation during continuous exposure was low over a short period of time (weeks), but varied significantly when longer time periods (months) were investigated. Inter-individual variation is currently only partly explained by genetic polymorphisms in genes involved in PAH-metabolism and deserves further investigation. DNA adduct measurement may have three advantages over traditional exposure assessment: i. they can smooth the extreme variability in exposure which is typical for environmental toxicants and may integrate exposure over a longer period of time. Therefore, DNA adduct assessment may reduce the monitoring effort. ii. Biological monitoring of DNA adducts accounts for all exposure routes. iii. DNA adducts may account for inter-individual differences in uptake, elimination, distribution, metabolism and repair amongst exposed individuals. In conclusion, there is now a sufficiently large scientific basis to justify the application of DNA adduct measurement as biomarkers in exposure assessment and intervention studies. Their use in risk-assessment, however, requires further investigation.

VISUALIZATION OF THE INTERNAL WATER DISTRIBUTION AT PEMFC USING NEUTRON IMAGING TECHNOLOGY: FEASIBILITY TEST AT HANARO

  • Kim Tae-Joo;Jung Yong-Mi;Kim Moo-Hwan;Sim Cheul-Muu;Lee Seung-Wook;Jeon Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • v.38 no.5
    • /
    • pp.449-454
    • /
    • 2006
  • Neutron imaging technique was used to investigate the water distribution and movement in Polymer Electrolyte Membrane Fuel Cell (PEMFC) at HANARO, KAERI. The Feasibility tests were performed in the first and second exposure rooms at the neutron radiography facility (NRF) at HANARO in order to check the ability of each exposure room, respectively. The feasibility test apparatus was composed of water and pressurized air before making up the actual test apparatus. Due to the low neutron intensity in the second exposure room, the exposure time was too long to investigate the transient phenomena of PEMFC. Although the exposure time was improved to 0.1 sec in the first exposure room, it was difficult to discriminate detail water movement at the channel due to the high noise level. Therefore, the experimental setup must be optimized according to the test conditions. Water discharge characteristics were investigated under different flow field geometries by using feasibility test apparatus and the neutron imaging technique. The water discharge characteristics of a 3-parallel serpentine are superior to those of a 1-parallel serpentine, but water at Membrane Electrode Assembly (MEA) was not removed, regardless of the flow field type.

Setting time properties of cement matrix according to photosynthetic bacterial dilution ratio (광합성 세균 희석 비율에 따른 시멘트 경화체의 응결 특성)

  • Pyeon, Su-Jeong;Kim, Dae-Yeon;Lim, Jeong-Jun;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.89-90
    • /
    • 2018
  • In recent years, harmful substances and fine dust in the air are caused by respiratory and cardiovascular diseases through various mechanisms when they are introduced into the human body through respiration, thereby exacerbating human health and causing cancer by prolonged exposure do. In order to prevent such fine dust from being introduced into the room and to improve indoor air quality, improvement of air quality has attracted attention. Among indoor air pollutants, fine dust and CO2 are pollutants that are directly affected by indoor number and activity. The purpose of this study is to evaluate the basic performance of cement matrix using photosynthetic bacteria as a basic study of fine dust and CO2 adsorption type matrix to suppress indoor air pollution and improve air quality.

  • PDF

The Effect of Aircraft Parking Environment on Atmospheric Corrosion Severity (항공기 주기환경이 대기부식위험도에 미치는 영향)

  • Yun, Juhee;Lee, Dooyoul;Park, Sungryul;Kim, Min-Saeng;Choi, Dongsu
    • Corrosion Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.94-104
    • /
    • 2021
  • Atmospheric corrosion severity associated with aircraft parking environment was studied using metallic specimens, and temperature and humidity sensors installed at each aircraft operating base. Data were analyzed after a year of exposure. Silver was used to measure chloride deposition by integrating X-ray photoelectron spectroscopy depth profiles. Carbon steel was utilized to determine the corrosion rate by measuring the weight loss. The time of wetness was determined using temperature and humidity sensor data. Analysis of variance followed by Tukey's "honestly significant difference" test indicated that atmospheric environment inside the shelter varied significantly from that of unsheltered parking environment. The corrosion rate of unsheltered area also varies with the roof. Hierarchical clustering analysis of the measured data was used to classify air bases into groups with similar atmospheric corrosion. Bases where aircraft park at a shelter can be grouped together regardless of geographical location. Unsheltered bases located inland can also be grouped together with sheltered bases as long as the aircraft are parked under the roof. Environmental severity index was estimated using collected data and validated using the measured corrosion rate.