• 제목/요약/키워드: air data sensor

검색결과 301건 처리시간 0.029초

KEOP-2007 라디오존데 관측자료를 이용한 장마 특성 분석: Part I. 라디오존데 관측 자료 평가 분석 (The Analysis of Changma Structure using Radiosonde Observational Data from KEOP-2007: Part I. the Assessment of the Radiosonde Data)

  • 김기훈;김연희;장동언
    • 대기
    • /
    • 제19권2호
    • /
    • pp.213-226
    • /
    • 2009
  • In order to investigate the characteristics of Changma over the Korean peninsula, KEOP-2007 IOP (Intensive Observing Period) was conducted from 15 June 2007 to 15 July 2007. KEOP-2007 IOP is high spatial and temporal radiosonde observations (RAOB) which consisted of three special stations (Munsan, Haenam, and Ieodo) from National Institute of Meteorological Research, five operational stations (Sokcho, Baengnyeongdo, Pohang, Heuksando, and Gosan) from Korea Meteorological Administration (KMA), and two operational stations (Osan and Gwangju) from Korean Air Force (KAF) using four different types of radiosonde sensors. The error statistics of the sensor of radiosonde were investigated using quality control check. The minimum and maximum error frequency appears at the sensor of RS92-SGP and RS1524L respectively. The error frequency of DFM-06 tends to increase below 200 hPa but RS80-15L and RS1524L show vice versa. Especially, the error frequency of RS1524L tends to increase rapidly over 200 hPa. Systematic biases of radiosonde show warm biases in case of temperature and dry biases in case of relative humidity compared with ECMWF (European Center for Medium-Range Weather Forecast) analysis data and precipitable water vapor from GPS. The maximum and minimum values of systematic bias appear at the sensor of DFM-06 and RS92-SGP in case of temperature and RS80-15L and DFM-06 in case of relative humidity. The systematic warm and dry biases at all sensors tend to increase during daytime than nighttime because air temperature around sensor increases from the solar heating during daytime. Systematic biases of radiosonde are affected by the sensor type and the height of the sun but random errors are more correlated with the moisture conditions at each observation station.

인텔리전트 컨포넌트 (Intelligent Conponent) (Intelligent Conponent)

  • 미즈타까준;서길진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.103-108
    • /
    • 2008
  • Automatic control makes the air-handling unit go into operation and determines the functions of high-efficient and energy-saving machines. Yamatake, an automatic control system manufacturer, have expanded fault detection and diagnosis, and data volumes so as to achieve higher technology in control by developing a sensor which makes field data visible, an actuator and Intelligent Conponent. This study, thus, focuses on applications for saving energy with Intelligent Conponent and goes in for easing global warming by creating future field data-based applications.

  • PDF

Development of Smart Healthcare Scheduling Monitoring System for Elderly Health Care

  • Cho, Sooyong;Lee, Sang Hyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제10권2호
    • /
    • pp.51-59
    • /
    • 2018
  • Health care has attracted a lot of attention, recently due to an increase in life expectancy and interest in health. Various biometric data of the user are collected by using the air pressure sensor, gyro sensor, acceleration sensor, and heart rate sensor to perform the Smart Health Care Activity Tracker function. Basically, smartphone application is made and tested for biometric data collection, but the Arduino platform and bio-signal measurement sensor are used to confirm the accuracy of the measured value of the smartphone. Use the Google Maps API to set user goals and provide guidance on the location of the user and the points the user wants. Also, the basic configuration of the main UI is composed of the screen of the camera, and it is possible for the user to confirm the forward while using the application, so that accident prevention is possible.

자동차 배기계용 산소센서 내부유동 특성 평가 (Evaluation of Inner Flow Characteristics of Oxygen Sensor for Vehicle Exhaust System)

  • 한대광;서호철;이정재;강정호;한승호
    • 한국기계가공학회지
    • /
    • 제11권2호
    • /
    • pp.47-54
    • /
    • 2012
  • An oxygen sensor installed in vehicle exhaust systems enables to measure the amount of oxygen in the exhaust gas, in which the measured data are collected and analyzed in ECU(Engine Control Unit). The oxygen sensor is exposed to the high speed exhaust gas at high temperature circumstance, so that protection caps are required not only to protect the susceptible measuring part, but also to provide the real time measurement without time delay. In this study, a new oxygen sensor with one protection cap was proposed, and the CFD analysis was carried out in order to compare the performance characteristics, such as flow speed and ratio of AOA(Age of Air), for the conventional and new oxygen sensor. The numerical results of CFD analysis provided the flow speed of 1.34m/s and the ratio of AOA of 3.43. The similar features obtained from the numerical results showed that the new oxygen sensor guarantees the same performance characteristics of the conventional ones.

소형 통합형 비행조종컴퓨터 개발 (Development of the compact Integrated Flight Control Computer)

  • 장성호;구삼옥;박주원
    • 항공우주시스템공학회지
    • /
    • 제2권1호
    • /
    • pp.17-21
    • /
    • 2008
  • A compact, light-weight, integrated flight control computer(IFCC) for small unmanned autonomous vehicles is developed. Its design objective is to produce an all in one avionics system which includes the navigation sensor, data link, attitude sensors and air data sensors. The initial phase of ground and flight tests are performed to verify the prototype IFCC, showing promising results. The high potential of its application is expected.

  • PDF

IoT 기반 실내 공기질 모니터링 시스템 (Indoor Air Quality Monitoring Systems in the IoT Environment)

  • 오창세;서민석;이정혁;김상현;김영돈;박현주
    • 한국통신학회논문지
    • /
    • 제40권5호
    • /
    • pp.886-891
    • /
    • 2015
  • 최근 전 세계적으로 인류의 건강을 위협하는 요소로 대기오염이 대두되고 있는 가운데 세계보건기구(WHO : World Health Organization)의 발표에 의하면 대기오염으로 인해 사람의 건강을 해친다고 발표했으며, 서울시의 '2011~2014년 7월 다중이용시설 실내 공기 질 측정 결과'에 의하면 대부분의 다중이용시설에서 실내공기오염도 기준을 위반한 것으로 조사되었다. 이러한 실내에서 발생하는 대기오염은 폐 질환, 천식, 기관지염 등의 질병을 유발하며 본 논문에서는 이와 관련하여 환경센서를 이용하여 실내공기질을 측정하고, 측정된 데이터를 분석하여 환기 개선에 필요한 액츄에이터 신호를 생성하고 실시간으로 실내 공기 질 측정 모니터링 시스템을 구현하여, 우리 생활에서 대기오염을 자율적으로 관리할 수 있도록 한다.

차량 내부 환경 제어용 무선 자동화 시스템 구현 (Implementation of Wireless Automatic Control System for Vehicle Interior Environment)

  • 조해성;조주필
    • 한국인터넷방송통신학회논문지
    • /
    • 제10권5호
    • /
    • pp.287-291
    • /
    • 2010
  • 본 논문에서는 차량 자동화 구현을 위한 센서네트워크 기반의 차량용 자동화 시스템을 설계 및 구현하였다. 이를 위하여 자동차내부의 각종 센서로부터 Zigbee 센서 망을 이용하여 무선으로 각종 센싱 데이터를 수집한 후 모니터 프로그램에서 이를 분석한다. 그리고 분석된 데이터를 무선 단말기와 인터페이스 시켜 차량의 상태 정보를 한눈에 운전자가 한눈에 파악할 수 있도록 하였다. 또한, 센서 네트워크 기반으로 온도센서, 습도센서 그리고 조도센서 등을 모니터링하고 이들 데이터를 기반으로 히터, 에어콘 및 차량의 실내등을 자동 구동시키는 차량 내 온/습도 자동제어 및 조도 자동조절기를 구현하였다.

공기구동기 성능평가 시스템 개발 (The Development of Performance Evaluation System for Air-Operated Actuaotr)

  • 조택동;양성빈;이호영;양상민;권봉수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1770-1773
    • /
    • 2005
  • The performance evaluation of AOV(air-operated valve) requires the processes to confirm the actuator system capability. It is necessary to evaluate the thrust of the air actuator for the margin evaluation. In this paper, to evaluate and analysis the air actuator, the performance test system and operating program are developed. This system is composed of several sensors such as pressure sensor, LVDT, and LoadCell which are used to get the data for evaluation. The LabVIEW was used for developing the operating program. The test system and operating program are proved through the actual test of the diaphragm actuator.

  • PDF

Flicker-free Visible Light Communication Using Three-level RZ Modulation

  • Lee, Seong-Ho
    • 센서학회지
    • /
    • 제29권2호
    • /
    • pp.75-81
    • /
    • 2020
  • We introduce a new visible light communication (VLC) method in which three-level return-to-zero (RZ) modulation is used for flicker-free transmission. In the VLC transmitter, the three-level RZ modulation ensures that the average optical power is constant; thus, a flicker-free light-emitting diode (LED) light is achieved. In the VLC receiver, a resistor-capacitor high-pass filter is used for generating spike signals, which are used for data recovery while eliminating the 120 Hz optical noise from adjacent lighting lamps. In transmission experiments, we applied this method for wireless transmission of an air quality sensor message using the visible light of an LED array. This configuration is useful for the construction of indoor wireless sensor networks for air pollution monitoring using LED lights.

Sensing Characterization of Metal Oxide Semiconductor-Based Sensor Arrays for Gas Mixtures in Air

  • Jung-Sik Kim
    • 한국재료학회지
    • /
    • 제33권5호
    • /
    • pp.195-204
    • /
    • 2023
  • Micro-electronic gas sensor devices were developed for the detection of carbon monoxide (CO), nitrogen oxides (NOx), ammonia (NH3), and formaldehyde (HCHO), as well as binary mixed-gas systems. Four gas sensing materials for different target gases, Pd-SnO2 for CO, In2O3 for NOx, Ru-WO3 for NH3, and SnO2-ZnO for HCHO, were synthesized using a sol-gel method, and sensor devices were then fabricated using a micro sensor platform. The gas sensing behavior and sensor response to the gas mixture were examined for six mixed gas systems using the experimental data in MEMS gas sensor arrays in sole gases and their mixtures. The gas sensing behavior with the mixed gas system suggests that specific adsorption and selective activation of the adsorption sites might occur in gas mixtures, and allow selectivity for the adsorption of a particular gas. The careful pattern recognition of sensing data obtained by the sensor array made it possible to distinguish a gas species from a gas mixture and to measure its concentration.