• Title/Summary/Keyword: air conditioning

Search Result 8,505, Processing Time 0.032 seconds

THE EFFECTS OF VARIOUS ALL-ETCHING AGENTS AND VARIED ETCHING TIME ON ENAMEL MORPHOLOGY AND BOND STRENGTH (수종의 All-Etching Agent와 산부식시간에 따른 법랑질 산부식형태 및 전단 결합강도에 관한 연구)

  • Kwon, So-Ran;Yoon, Tae-Hyun;Park, Dong-Soo
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.136-149
    • /
    • 1996
  • The effects of various All-Etching Agents (10% phosphoric acid, 10% maleic acid and 10 % citric acid) and 32 % phosphoric acid and varied etching time were evaluated by observing the morphology of the etched enamel surfaces using Scanning electron microscopy and by measuring the shear bond strength of a composite resin to human enamel. A total of 156 extracted premolar and molar teeth free of irregularities were employed in this study. Specimens for the observation of enamel morphology were divided into 12 groups of 3 teeth each, based on the type of etchant used and application time. After exposure to the etching agent specimens were washed air-dried and then glued to aluminum stubs and coated with a layer of gold for examination in the scanning electron microscope. Specimens for the evaluation of bond strength were divided into 12 groups of 10 teeth each also based on the type of etchant used and application time. After exposure to the etching agent the specimens were washed, air-dried and a thin layer of bonding agent was applied using a brush. Z 100 composite resin was light cured to the surface and stored at $37^{\circ}C$, 100% humidity for 7 days. An Instron Universal Testing Machine was used to apply a shearing force at $90^{\circ}$ angle from the enamel surface. It is concluded from this study that commercial All-etching agents can be used with a 15-second etching without adversely affecting retention of dental resin materials. At the same time, the acid concentration is probably a suitable compromise regarding the acid's function as a dentin demineralizing all-etch conditioning agent. The following results were obtained. 1. Specimens etched with 10 % citric acid showed a random superficial etching pattern which could not be related to prism morphology. 2. Specimens etched with 10 % and 32 % phosphoric acid and 10 % maleic acid showed a type I pattern in which core material was preferentially removed leaving the prism peripheries relatively intact or a type II pattern in which prism peripheries were preferentially removed. This delineation became more distinguished as etching time was increased. 3. All-Etching Agents and 32 % phosphoric acid showed a statistically significant higher shear bond strength at 15 seconds etching time.(p<0.05) 4. 10 % maleic acid and 32 % phosphoric acid exhibited a statistically significant higher shear bond strength than 10 % phosphoric and citric acid at 15 seconds etching time.(p<0.05).

  • PDF

Conservation Environmental Assessment and Microbial Distribution of the Songsan-ri Ancient Tombs, Gongju, Korea (공주 송산리 고분 내 미생물 분포 및 보존환경 연구)

  • Lee, Min Young;Kim, Dae Woon;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.30 no.2
    • /
    • pp.169-179
    • /
    • 2014
  • After occurrence of Cyanobacteria in 1997, Songsan-ri tombs located in Gonju have been investigated to monitor for biological damage. The room temperature of Tomb No.6 was $18.6{\sim}19.8^{\circ}C$ and the relative humidity was 94.3~99.9%. The temperature of Royal Tomb of King Muryeong was $17.3{\sim}18.53^{\circ}C$ and the relative humidity was 73.2~96.45%. The variation of relative humidity increased after setting up air vents. If the outside temperature increases, dew condensation occurs on the floor and the north side. When conditioning equipment operates, the maximum temperature differences between walls is $2.8^{\circ}C$. Bacteria from the air of the tomb and on the surface of the walls outnumbered fungi. 20 species of fungi including Alternaria sp., Aspergillus sp., Penicillium sp., and 19 species of bacteria including Pseudomonas sp., Arthrobacter sp., are identified. Microbes in the tombs may damage cultural heritage. The growth possibility of microbes should be estimated because the microbes in the tombs may damage mural painting. The interrelation between microenvironmental condition and biological damage of mural painting should be researched to come up with an long-term conservation method.

Estimation of THI Index to Evaluate Thermal Stress of Animal-occupied Zone in a Broiler House Using BES Method (BES 기법을 이용한 육계사 내부 고온 스트레스 평가를 위한 THI 지수 모의)

  • Ha, Taehwan;Kwon, Kyeong-seok;Hong, Se-Woon;Choi, Hee-chul;Lee, Jun-yeob;Lee, Dong-hyun;Woo, Saemee;Yang, Ka-young;Kim, Rack-woo;Yeo, Uk-hyeon;Lee, Sangyeon;Lee, In-bok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.2
    • /
    • pp.75-84
    • /
    • 2018
  • Thermal stress of livestock has been issued due to recent climate change trends and this causes reproductive disorders, decreased feed consumption, immunosuppression, and increased mortality of animals. Concept of THI has been widely used to quantitatively evaluate the degree of thermal stress for animals, however use of this concept is restricted for animals living in the enclosed facilities such as mechanically ventilated broiler houses. In this study, time-based internal energy flow and variation trends of temperature and humidity were analyzed based on BES technique. Local weather data, insulation characteristics of building materials, heat and moisture generation rate from broilers according to age, algorithm of ventilation operation were adopted for boundary condition of the model to accurately compute THI values inside the mechanically ventilated broiler house. From the BES computation, excess frequency of THI threshold in Jeju city was highest on the assumption that air conditioning equipments were not installed. When general raising density ($39kg\;m^{-2}$) was adopted, total 2,191 hours were exceeded. Excess hours of THI threshold were strongly related to the cumulative air temperature ($R^2=0.87$).

Interpretation on Internal Microclimatic Characteristics and Thermal Environment Stability of the Royal Tombs at Songsanri in Gongju, Korea (공주 송산리 고분군 내부의 미기후 특성 및 온열환경 안정성 해석)

  • Kim, Sung Han;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.35 no.2
    • /
    • pp.99-115
    • /
    • 2019
  • The Royal Tombs at Songsanri is one of the most important historic site for ancient historical study in Korean Peninsula. Since the excavation of the tombs, continuous exposure to the outside environment and the negative effects of the artificial air conditioning system have caused significant threats to the thermal environment stability of the tombs. Unlike the outside temperature that shows significant differences according to seasonal changes, the burial chamber of the tombs had a relatively stable temperature range of 11.4 to $22.2^{\circ}C$ throughout the year, and the standard deviation of temperature was within 3.5. It was revealed that major factors affecting the microclimate of the tombs were inflow of outdoor air, wind direction and speed, and all of them had closely related to airtightness of the tombs. The solar radiation was in inverse proportion to the thickness of burial mounds, and thus Royal Tomb of King Muryeong, which has the thickest burial mound, was least affected by solar radiation. Especially, microclimate of the tombs caused to the highest influence with artificial environmental changes due to access by people, which varied in proportion to the number of accessed people and time of stay. Currently, the inside of the tombs are sealed and always in saturated condition, it is very vulnerable to dew condensation. As a result of analyzing the possibility of condensation in each tomb, all the tomb No. 5, tomb No. 6 and Royal Tomb of King Muryeong had condensation most of the time throughout the year. It is required to make a proper conservation environment for the Royal Tombs at Songsanri.

Analysis and Investigation of International(UIC, EN, IEC) and Domestic Standards(Test Methods) for Climatic Wind Tunnel Test of Rolling Stock (철도차량 기후환경시험을 위한 국제 규격(UIC, EN, IEC) 및 국내 규격(시험방법) 분석 및 고찰)

  • Jang, Yong-Jun;Chung, Jong-Duk;Lee, Jae-Cheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.782-789
    • /
    • 2020
  • The demand for the development of rolling stock technology to maintain the best performance in various climatic environments has increased to expand the overseas market of rolling stock. In this study, international and domestic standards that must be applied to build a harsh climatic environment test system were investigated and compared. The way of improvement for domestic standards is proposed. The wind velocities and temperatures are specified in the UIC, EN, and IEC standards for climatic wind tunnel, and EN 50125-1 provides the velocity test up to 180km/h, the largest wind speed. UIC and EN provide the lowest temperature of -45℃, and IEC 62498-1 provides the highest temperature 55℃. The solar radiation test was specified up to 1200W/m2 in the UIC, EN, and IEC. The IEC, EN, and KS R 9145 provide the water tightness standards, which are different from each other in water capacity, pressure, and methods. The snow test method was not well specified. KRTS-VE-Part 31 provides pressurization test methods. The airtightness standards for high-speed rolling stock are defined and regulated for internal pressure change rate in UIC 660 and 779-11. The domestic standard for the wind tunnel test was not well prepared, and the solar radiation test and snow test do not exist in Korea. Therefore, it is necessary to improve domestic standards to an international level for the climatic wind tunnel test of rolling stock.

Experimental Study of Transition to Secondary Acoustic Instability at Downward-Propagating Premixed Flame in a Tube (튜브 내 하향 전파하는 예혼합 화염의 이차 열음향 불안정성 천이에 관한 실험적 연구)

  • Park, Juwon;Kim, Daehae;Park, Dae Geun;Yoon, Sung Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.7
    • /
    • pp.915-921
    • /
    • 2020
  • Thermoacoustic instability caused by air conditioning in a combustion chamber has emerged as a problem that must be solved to establish a stable combustion system. Thermoacoustic instability is largely divided into primary and secondary acoustic instability. In this study, an experimental study of the effects of heat losses was conducted to investigate the mechanism of secondary acoustic instability. To generate the secondary acoustic instability, a quarter-wavelength resonator with one open end and one closed end was used, and the inside of the resonator was filled with premixed gases. Subsequently, secondary acoustic instability with downward-propagating flames could be realized via thermal expansion on the burnt side. To control heat losses qualitatively, an additional co-axial tube was installed in the resonator with air or nitrogen supply. Therefore, additional diffusion flames can be formed at the top of the resonator depending on the injection of the oxidizer into the co-axial tube when rich premixed flames are used. Consequently, secondary acoustic instability could not be achieved by increasing heat losses to the ambient when the additional diffusion flame was not formed, and the opposite result was obtained with the additional diffusion flame.

A study on the 3-step classification algorithm for the diagnosis and classification of refrigeration system failures and their types (냉동시스템 고장 진단 및 고장유형 분석을 위한 3단계 분류 알고리즘에 관한 연구)

  • Lee, Kangbae;Park, Sungho;Lee, Hui-Won;Lee, Seung-Jae;Lee, Seung-hyun
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.8
    • /
    • pp.31-37
    • /
    • 2021
  • As the size of buildings increases due to urbanization due to the development of industry, the need to purify the air and maintain a comfortable indoor environment is also increasing. With the development of monitoring technology for refrigeration systems, it has become possible to manage the amount of electricity consumed in buildings. In particular, refrigeration systems account for about 40% of power consumption in commercial buildings. Therefore, in order to develop the refrigeration system failure diagnosis algorithm in this study, the purpose of this study was to understand the structure of the refrigeration system, collect and analyze data generated during the operation of the refrigeration system, and quickly detect and classify failure situations with various types and severity . In particular, in order to improve the classification accuracy of failure types that are difficult to classify, a three-step diagnosis and classification algorithm was developed and proposed. A model based on SVM and LGBM was presented as a classification model suitable for each stage after a number of experiments and hyper-parameter optimization process. In this study, the characteristics affecting failure were preserved as much as possible, and all failure types, including refrigerant-related failures, which had been difficult in previous studies, were derived with excellent results.

Importance-Performance Analysis of Operation of Specialized Complexes for Horticultural Production (원예전문생산단지 운영에 대한 중요도-만족도 분석)

  • Hong, Na-Kyoung;Rhee, Zae-Woong;Kim, Tae-Kyun
    • Current Research on Agriculture and Life Sciences
    • /
    • v.33 no.1
    • /
    • pp.25-31
    • /
    • 2015
  • This study investigated the operation criteria of specialized complexes for horticultural production reflecting the farmers' preferences. First, the analysis of the communal activity included six factors: the group purchase of consumables for common activity, group purchase of the greenhouse apparatus, cooperative seed raising, use of a common air conditioning and heating system, cooperative shipping, and soil examination and certification system. The results of the Importance-Performance analysis can be summarized as follows. The factors requiring good management included the group purchase of consumables for common activity, group purchase of the greenhouse apparatus, and cooperative shipping. The factors with a lower priority included cooperative seed raising and the use of a common air conditioning and heating system. While the importance of the soil examination and certification system was low, the satisfaction was high, so this factor needs to be managed to avoid overkill. Second, the analysis of information exchange and education included six factors: production technique information, greenhouse facility management information, distribution-related information, production technique education, greenhouse facility management education, and distribution-related education. The results of the Importance-Performance analysis can be summarized as follows. The factor of production technique education was the most important determinant, plus the factors requiring good management included production technique information, greenhouse facility management information, and distribution-related information. The factors with a lower priority included greenhouse facility management education and distribution-related education. Therefore, to enhance productivity through facility modernization, the scaling up and creation of more specialized horticulture complexes are recommended as policy measures to gain export competitiveness. As the Korean government is expected to expand the scale of specialized horticulture complexes, the results of this paper can be widely utilized.

THE EFFECTS OF SURFACE CONTAMINATION BY HEMOSTATIC AGENTS ON THE SHEAR BOND STRENGTH OF COMPOMER (지혈제 오염이 콤포머의 전단결합강도에 미치는 영향)

  • Heo, Jeong-Moo;Kwak, Ju-Seog;Lee, Hwang;Lee, Su-Jong;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.150-157
    • /
    • 2002
  • One of the latest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not dry but left moist before application of the bonding primer Ideally the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically, contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during cavity preparation. The aim of this study was to evaluate the effect of contamination by hemostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were removed soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive papers on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows : Group 1: Dentin surface was not etched and not contaminated by hemostatic agents. Group 2: Dentin surface was not etched but was contaminated by Astringedent$^{\circledR}$(Ultradent product Inc., Utah, U.S.A.) Group 3: Dentin surface was not etched but was contaminated by Bosmin$^{\circledR}$(Jeil Pharm, Korea.). Group 4: Dentin surface was not etched but was contaminated by Epri-dent$^{\circledR}$(Epr Industries, NJ, U.S.A.). Group 5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6: Dentin sorface was etched and contaminated by Astringedent$^{\circledR}$. Group 7 : Dentin surface was etched and contaminated by Bosmin$^{\circledR}$. Group 8: Dentin surface was etched and contaminated by Epri-dent$^{\circledR}$. Group 9: Dentin surface was contaminated by Astringedent$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. Group 10: Dentin surface was contaminated by Bosmin$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. Group 11 : Dentin surface was contaminated by Epri-dent$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. After surface conditioning, F2000$^{\circledR}$ was applicated on the conditoned dentin surface The teeth were thermocycled in distilled water at 5$^{\circ}C$ and 55$^{\circ}C$ for 1,000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the knife-edge shearing rod of the Universal Testing Machine(Zwick Z020, Zwick Co., Germany) running at a cross head speed or 1.0 mm/min. Group 2 showed significant decrease in shear bond strength compared with group 1 and group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

An Experimental Study on Radiation/Convection Hybrid Air-Conditioner (복사-대류 겸용 하이브리드 냉방기에 대한 실험 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.288-296
    • /
    • 2019
  • Radiation cooling has used ceilings or floors as cooling surfaces. In such cases, to avoid moisture condensation on the surface, the surface temperature needs be higher than the dew point temperature or an additional dehumidifier is added. In this study, with a goal for residential application, intentional moisture condensation on the cooling surface was attempted, which increased the cooling capacity and improved the indoor comfortness. This method included two separate refrigeration cycles - convection-type dehumidifying cycle and the panel cooling cycle. Test results on the panel cooling cycle showed that, at the standard outdoor ($35^{\circ}C/24^{\circ}C$) and indoor ($27^{\circ}C/19.5^{\circ}C$) condition, the refrigerant flow rate was 8.8 kg/h, condensation temperature was $51^{\circ}C$, evaporation temperature was $8.8^{\circ}C$, cooling capacity was 376 W and COP was 1.75. Furthermore, the panel temperature was uniform within $1^{\circ}C$ (between $13^{\circ}C$ and $14^{\circ}C$). As the relative humidity decreased, the cooling capacity decreased. However, the power consumption remained approximately constant. In the convection-type dehumidification cycle, the refrigerant flow rate was 21.1 kg/h, condensation temperature was $61^{\circ}C$, evaporation temperature was $5.0^{\circ}C$, cooling capacity was 949 W and COP was 2.11 at the standard air condition. When both the radiation panel cooling and the dehumidification cycle operated simultaneously, the cooling capacity of the radiation panel cycle was 333 W and that of the dehumidification cycle was 894 W, and the COP was 1.89. As the fan flow rate decreased, both the cooling capacity of the radiation panel and the dehumidification cycle decreased, with that of the dehumidification cycle decreasing at a higher rate. Finally, a possible control logic depending on the change of the cooling load was proposed based on the results of the present study.