• Title/Summary/Keyword: air conditioner system

Search Result 407, Processing Time 0.022 seconds

Refrigerant Amount Detection Technology for System Air-Conditioner Using Design of Experiment (실험계획법을 이용한 시스템에어컨의 냉매량검지 기술개발)

  • Lee, Soo-Young;Takeichi, Hisashi;Tae, Sang-Jin;Yoon, Baek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.1
    • /
    • pp.26-32
    • /
    • 2010
  • This paper is suggesting a new technology for refrigerant amount detection of a system air-conditioner installed under various installation conditions. System air-conditioner was introduced to domestic market first in 2000. It consists of one or a series of outdoor units and a number of indoor units connected with single pipe line to the outdoor unit. The system can vary the capacity from 2.0 kW to 186 kW. For the system Installed under long and high-elevated condition, about 100 kg of refrigerant is charged in the whole system. In this paper, the new technology RAD (Refrigerant Amount Detection) with edge technology of refrigerant cycle control and measurement of a system air conditioner was developed and investigated for its application for the various installation conditions.

Fuzzy Algorithm for FDD Technique Development of System Multi-Air Conditioner (퍼지 알고리즘을 이용한 시스템 멀티 에어컨의 고장진단 알고리즘 개발)

  • Choi, C. S.;Tae, S. J.;Kim, H. M.;Cho, K. N.;Moon, J. M.;Kim, J. Y.;Kwon, H. J.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.11 s.242
    • /
    • pp.1220-1228
    • /
    • 2005
  • Fault detection and diagnostic (FDD) systems have the potential to reduce equipment downtime, service costs, and utility costs. In this study, model based algorithm and fuzzy algorithm were used to detect and diagnose various fault at System multi-air conditioner. various fault include the Refrigerant Low charging, Fouling of Indoor Heat Exchanger, Fouling of Outdoor Heat Exchanger A experimental verification was conducted in the 6HP System multi-air conditioner on an 8-floor building. Test results showed diagnosis result about 78 $\~$ 90$\%$ for given faults. This Study lays the foundation fur future work on develope the real-time fault detection and diagnosis system for the System multi-air conditioner.

Thermal Behavior of Air Conditioning System in an Indoor Energy Storage System (실내 에너지저장시스템 공조시스템의 열적 거동에 관한 연구)

  • Kim, Junyoung;Choi, Naksam;Kim, Jintaek
    • New & Renewable Energy
    • /
    • v.17 no.1
    • /
    • pp.33-39
    • /
    • 2021
  • The energy use is increasing as the quality of human life improves. and research on the efficient use of energy in ESS (Energy Storage System) is ongoing. An air conditioner is required for the efficient use of an ESS, as are data on the distribution of the temperature of the latter based on the capacity of the air conditioner. In the absence of an air conditioner, the battery of the ESS reaches its maximum temperature of 40℃ after 2 h. When an air conditioner is present, the temperature of the battery stabilizes as the capacity of the former increases.

The Analysis for Thermal Comfort Evaluation during long time operating Air Conditioner (에어컨 장시간 운전시 온열쾌적감 평가에 관한 연구)

  • Kim, Dong-Gyu;Park, Jong-Il;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.59-64
    • /
    • 2007
  • Using air conditioner has been increased in home or office buildings in summer. Also various problems related to air conditioning such as disease induction happened by using air conditioner excessively and operating long. Active operation control is needed for occupant's health when air conditioner operates long. We should think ahead to acquire thermal comfort of occupants which represents psychological and physiological reaction for this operation. Research has been progressed to observe activity of autonomic nervous system by trying to quantitate change of thermal comfort. In this study, questions of the subject and change of body's autonomic nervous system were chosen to evaluate thermal comfort during operation of air conditioner for a long time. Electrocardiogram and questions of the subject which is the progress of changing TSV and CSV by occupants indoor were measured when room air conditioner is operated for a long time, and an air-conditioned adaptability of human body was evaluated by acquiring the change rate of autonomic nervous system through analyzing HRV. As a result of the evaluation, change rate of body's autonomic nervous system corresponded to votes of the subject's question generally, but was distinguished from analysis result of warm-cold sensation in a low temperature area.

Numerical study on the flow characteristics in Air-conditioner duct of EMU (전동차 공조기 덕트 내의 유동특성에 관한 수치해석적 연구)

  • Kim Seung-Tech;Kim Sung-Jong;Park Geun-Soo;Park Hyung-Soon
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.345-350
    • /
    • 2003
  • The inside of EMU is supplied with the cooling air from air-conditioner and the fresh air from exterior through the air-conditioner duct which is one of the air conditioning system. The shape of air-conditioner duct is a major factor in determining the air-conditioning efficiency, thermal comfort and energy efficiency. Therefore, this study is to understand the flow characteristics in the air-conditioner duct by three dimensional numerical simulation. The air-conditioner duct was calculated for the design volume flow rate, $2,726\;m^3/h/unit$. From the result of calculation and measurement, the velocity at diffuser outlet presented good agreement in general. [n this present study, the calculation was also performed for three volume flow rate(1,800, 2,200, 3,000 $m^3/h/unit$) and total pressure characteristic curve with volume flow rate was presented.

  • PDF

Study on the Development for Low Noise Indoor Unit Package Air-Conditioner (저소음 패키지형 공기조화기의 실내기 개발에 관한 연구)

  • 이재효;조성철;김태헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.518-523
    • /
    • 2003
  • The purpose of this study was to reduce the noise emitted from the package air-conditioner. The optimum design methods of the fans ware investigated experimentally through the analysis of noise problem caused by the conventional PAC system. New PAC system had decreased 6 dBA in overall noise level as compared with the conventional system by various technology.

The Effects of the Refrigerant Charge on the Performance of an Air Conditioner with Capillary Tube Expansions (냉매충전량이 모세관 팽창장치를 가진 공기조화기의 성능에 미치는 영향)

  • 최은수;김종배
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.359-364
    • /
    • 2002
  • A popular type of residential air conditioner is the split system which has two separate units: indoor and outdoor units During field installation of the split system, the potential exists for not setting the charge exactly to the manufacturer´s specifications. The objective of this study is to investigate the effects of the refrigerant charge on the performance of the air conditioner. An air conditioner with capillary tube expansions was tested for various refrigerant charges. The results indicated that the more charge resulted in the more flowrate of the refrigerant. The flowrate of the refrigerant was one of the most important factors to understand the e(sects of the charge on the performance of the air conditioner with capillary tube expansions. Under-charge results in wide region of superheated vapor of the refrigerant in the evaporator, while over-charge results in high temperature of the liquid refrigerant in the evaporator.

A study on the performance of a split system inverter air-conditioner at different operation conditions (분리형 인버터 에어컨의 운전조건에 따른 성능 연구)

  • Kim, Man-Hoe
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.1
    • /
    • pp.113-121
    • /
    • 1998
  • The performance evaluation of a residential split system inverter air-conditioner has been conducted analytically and experimentally at different system operating conditions. A simulation program for modelling an air-conditioning system which consists of a compressor, a condenser, a capillary tube, an evaporator and related attachments was developed on the basis of the Oak Ridge heat pump design model, MARK III. The accuracy of the simulation results for the compressor frequencies of 32, 68 and 79 Hz for the residential split system inverter air-conditioner has been estimated by comparing calculation results to the experimental data and parametric study has been performed to investigate the effect of design parameters and operation conditions on the system performance.

Development of Simulation Program of Automotive Engine Cooling System (자동차 엔진냉각계의 해석 프로그램의 개발)

  • 배석정;이정희;최영기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.11
    • /
    • pp.943-956
    • /
    • 2003
  • A numerical program has been developed for the simulation of automotive engine cooling system. The program determines the mass flow rate of engine coolant circulating the engine cooling system and radiator cooling air when the engine speed is adopted by appropriate empirical correlation. The program used the method of thermal balance at individual element through the model for radiator component in radiator analysis. This study has developed the program that predicts the coolant mass flow rate, inlet and outlet temperatures of each component in the engine cooling system (engine, transmission, radiator and oil cooler) in its state of thermal equilibrium. This study also combined the individual programs and united into the total performance analysis program of the engine cooling system operating at a constant vehicle speed. An air conditioner system is also included in this engine cooling system so that the condenser of the air conditioner faces the radiator. The effect of air conditioner to the cooling performance, e.g., radiator inlet temperature, of the radiator and engine system was examined. This study could make standards of design of radiator capacity using heat rejection with respect to the mass flow rate of cooling air. This study is intended to predict the performance of each component at design step or to simulate the system when specification of the component is modified, and to analyze the performance of the total vehicle engine cooling system.

Performance Characteristics of a Hybrid Air-Conditioner for Telecommunication Equipment Rooms (통신기지국용 하이브리드 냉방기의 성능특성 연구)

  • Kim, Yong-Chan;Choi, Jong-Min;Kang, Hoon;Yoon, Joon-Sang;Kim, Young-Bae;Choi, Kwang-Min;Lee, Ho-Seong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.11
    • /
    • pp.874-880
    • /
    • 2006
  • The power density and heat dissipation rate per unit area of the telecommunication equipment have been increased with the technology development in the footprint of telecommunication hardware. A proper heat dissipation method from the PCB module is very important to allow reliable operation of its electronic component. In this study, a hybrid air-conditioner for the telecommunication equipment room was designed to save energy and obtain system reliability. For high outdoor temperatures, the hybrid system operates in the vapor compression cycle, while, for low outdoor temperatures, the hybrid system works in the secondary fluid cooling cycle with no operation of the compressor. The performance of the hybrid air-conditioner was measured by varying outdoor and indoor temperatures. The hybrid air-conditioner yielded 50% energy saving compared with the conventional refrigeration system when the mode switch temperature was $8.3^{\circ}C$.