• Title/Summary/Keyword: air change effectiveness

Search Result 77, Processing Time 0.026 seconds

Study of the cap-and-trade system against the air pollutants in the Seoul Metropolitan Area and suggestion for its enforcement throughout South Korea (수도권 대기오염물질 배출권거래제에 대한 고찰 및 총량제 확대 시행을 위한 제언)

  • Park, Min Ha;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.15 no.4
    • /
    • pp.159-171
    • /
    • 2019
  • The cap-and-trade system against the air pollutants in the Seoul Metropolitan Area (SMA), Korea has been implemented since 2008 and will be implemented other areas in Korea on 2020. In this study, to identify the outcome and effectiveness of the cap-and-trade system in the SMA, (1) the rate of change for NOx and SOx emissions, (2) differences between the real emission and allocated amount, and (3) the status of trading are reviewed. It was found that the NOx and SOx emissions from the sources under the cap-and-trade system decreased in the SMA but the reduction was mainly due to the reduction of fuel usage not related to the system. It was found that the average percentage of annual emission in the SMA to the allocated amount between 2008 and 2018 was 66.9% for NOx and 69.3% for SOx, respectively. It suggests that there was over allocation of the emission amounts. The average trading prices in the SMA were 0.193 $/kg for NOx and 0.128 $/kg for SOx, far lower than those in RECLAIM, 131.942 $/kg and 81.677 $/kg, respectively. It was suggested that (1) the cap system for NOx and SOx emissions should be implemented only for the area with high emission ratio from large point sources, (2) the trade system is not suitable for the effective implementation of the cap system, and (3) Korean government should not allow over allocation in order to ensure sound market function without delaying the introduction of technology.

Analysis on the Effects of Building Coverage Ratio and Floor Space Index on Urban Climate (도시의 건폐율 및 용적률이 도시기후에 미치는 영향 분석)

  • Yeo, In-Ae;Yee, Jurng-Jae;Yoon, Seong-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.3
    • /
    • pp.19-27
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed by 3-Dimensional Urban Canopy Model. The characteristics of urban climate were analyzed combining artificial land coverage, building size, heat production from the air conditioning and topographic conditions as physical variables which affects urban climate characteristics. The results are as follows. (1) The aspects of the urban climatal change is derived to be related to the combination of the building coverage ratio, building height and shading area. According to the building height, the highest temperature was increased by $2.1^{\circ}C$ from 2-story to 5-story building and the absolute humidity by 2.1g/kg maximum and the wind velocity by 1.0m/s was decreased from 2-story to 20-story building. (2) Whole heat generation was influenced by the convective sensible heat at the lower building height and by the artificial heat generation at the higher one over 20-story building influence to some extent of the building coverage ratio. The effect of the altitude is not more considerable than the other variables as below $1^{\circ}C$ of the air temperature. In the last, deriving the combination of building coverage and building height is needed to obtain effectiveness of the urban built environment planning at the point of the urban climate. These simulation results need to be constructed as DB which shows urban quantitative thermal characters by the urban physical structure. These can be quantitative base for suggesting combinations of the building and urban planning features at the point of the desirable urban thermal environment as well as analyzing urban climate phenomenon.

The Effects of Alternating Set Pressure Changes on Dynamic Tissue Perfusion Characteristics (교대부양 설정압력 변화가 인체조직의 동적인 관류특성에 미치는 영향)

  • Won, Byeong-Hee;Song, Chang-Seop
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.6
    • /
    • pp.875-887
    • /
    • 2010
  • The quantitative effectiveness of powered support surfaces such as APAM in preventing and treating pressure ulcers has not been sufficiently evaluated because of uncertainty of alternating pressure load input and lack of interpretation of dynamic perfusion characteristics of soft tissue. The aim was to verify the dynamic loading effects to sacral tissue perfusion characteristics from alternating set pressure changes. We developed integrated experiment system to supply alternating load to supinely positioned sacrum and concurrently measured $TcPO_2$, $TcPCO_2$ and air cell pressure. Ten aged subjects (5 female, 5 male) were tested with alternating set pressure 20, 30, 40, 50 and 60mmHg. From the dynamic perfusion response eight characteristic parameters were proposed such as average, minimum, maximum and perfusion range regarding to $TcPO_2$ and $TcPCO_2$. A one-way ANOVA was carried out to determine whether the manipulation of alternating set pressure had any effect on $TcPO_2$ and $TcPCO_2$. From the dynamic tissue perfusion response we found mean $TcPO_2$ decreased exponentially as alternating pressure load increased and perfusion range varied mainly because of minimum level change of $TcPO_2$. And perfusion range of $TcPCO_2$ affected by increase of maximum value of $TcPCO_2$. From the results we can get more strict insights about actual physiological dynamic tissue perfusion mechanism under alternating pressure load.

The Effectiveness of Cardiopulmonary Resuscitation Training Targeted for Nursing Students (간호학생에게 실시한 심폐소생술 교육의 효과)

  • Han Jung-Suk;Ko Il-Sun;Kang Kyu-Sook;Song In-Ja;Moon Seong-Mi;Kim Sun-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.6 no.3
    • /
    • pp.493-506
    • /
    • 1999
  • The purpose of the study is to evaluate the effectiveness and competence level of trainees of Cardiopulmonary resuscitation training targeted for nursing students. 70 nursing students of Y nursing college are recruited as subjects from Dec. 1st, 1998 through Dec. 8th. 1998. For the pre-test. demographic data related to CPR and knowledge of CPR were evaluated. For the post-test, the next week of pre-test, three difference groups of subjects were tested their knowledge of CPR. CPR training was designed by two components which were 90 mins lecture and demonstration by one professor and individual practice using two educational models with two professors. As the tool of measurement estimating pre or post knowledge of CPR. questionnaires were developed based on self-diagnosis questionnaires of American Heart Association(AHA). The questionnaires were multiple choices (50 questions) and open end questions regarding CPR process. Each multiple choices questions valued 2 points (Score varied min. 0 point to max 100 points.). Collected data were computerized and analyzed by SPSS-WIN. Frequency and percentage of each questions analyzed. The differences of the knowledge and competency level of subjects between pre and post test was analyses by paired t-test. The followings are research outcome. 1. In the pre-test, 95% of subjects answered that they already knew what CPR was. but only 82% described correctly what CPR was. 49% learned CPR before, and 80s5 of them learned at high school. 2. 37 questions scores increases, and 10 questions scores decreased. 3 questions didnt change their score. After getting training, ratio of 80% correct score significantly increased 4 times. 3. In post-test. knowledge level of trainees increased compared to that of pre-test. (t=-15.075, p=.000) 4. Competence level also increased (t=-14.86, p=.00). In result, after getting CPR training, most CPR knowledge increased except open the air tract, toddler CPR, and alternative behavior when the air tract is blocked. CPR training needs to extend the educational scope not only CPR lecture but also psychomotor skill practice. CPR trainees are in need of appropriate feedback as well as enough opportunities of skill practice.

  • PDF

Effect of Evasive Maneuver Against Air to Air Infrared Missile on Survivability of Aircraft (공대공 적외선 위협에 대한 회피기동이 항공기 생존성에 미치는 영향)

  • Bae, Ji-Yeul;Bae, Hyung Mo;Kim, Jihyuk;Jung, Dae Yoon;Cho, Hyung Hee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.6
    • /
    • pp.501-506
    • /
    • 2017
  • An infrared seeking missile does not emit any signal by itself as it is guided by passive heat signature from an aircraft. Therefore, it is difficult for the target aircraft to notice the existence of incoming missile, making it a serious threat. The usage of MAW(missile approach warning) that can notify the approaching infrared seeking missile is currently limited due to its high cost. Furthermore, effectiveness of MAW against infrared seeking missile is not available in open literature. Therefore, effect of evasive maneuver by MAW on the survivability of the aircraft is simulated to evaluate the benefit of the MAW in this research. The lethal range is used as a measure of aircraft survivability. An aircraft flying at an altitude of 5km with Mach 0.9 being tracked by air-launched AIM-9 infrared seeking missile is considered in this research. As a variable for the evasive maneuver, the MAW recognition distance of 5~7km and the G-force of 3~7G that limits maximum directional change of the aircraft are considered. Simulation results showed that the recognition of incoming missile by MAW and following evasive maneuver can reduce the lethal range considerably. Maximum reduction in lethal range is found to be 29.4%. Also, the MAW recognition distance have a greater importance than the aircraft maneuverability that is limited by structural limit of the aircraft.

Study on forming Process of Piston Crown Using Near Net Shaping Technology (재료이용율 향상을 위한 피스톤 크라운 성형공정 연구)

  • Choi, H.J.;Choi, S.;Yoon, D.J.;Jung, H.S.;Choi, I.J.;Baek, D.K.;Choi, S.K.;Park, Y.B.;Lim, S.J.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.197-198
    • /
    • 2008
  • The forging process produces complicated and designed components in a die at high productivity for mass production and minimizes the machining amount for favorable material utilization; the forging products used at highly stressed sections are well accepted at a wide range of industry such as automobile, aerospace, electric appliance and et cetera. Accordingly, recent R&D activities have been emphasized on improvement of forging die-life and near net shaping technology for cost effectiveness and better performance. Usually closing and consolidation of internal void defects in a ingot is a vital matter when utilized as large forged products. It is important to develop cogging process for improvement of internal soundness without a void defect and cost reduction by solid forging alone with limited press capacity. For experiments of cogging process, hydraulic press with a capacity of 800 ton was used together with a small manipulator which was made for rotation and overlapping of a billet. Size of a void was categorized into two types; ${\phi}$ 6.0 mm and ${\phi}$ 9.0 mm to investigate the change of closing and consolidation of void defects existed in the large ingot during the cogging process. In addition for forming experiment of piston grown air drop hammer with a capacity of 16 ton was used. The experiment with piston crown was carried out to show the formability and void closing status. In this paper systematic configuration for closing process of void defects were expressed based on this experiment results in the cogging process. Also forging defects through forming process for piston crown was improved using the experiment results and FE analysis. Consequently this paper deals with the effect of radial parameters in cogging process on a void closure far large forged products and formability of piston crown.

  • PDF

Performance Evaluation of a $CO_2$ Heat Pump System for Fuel Cell Vehicles (연료전지 자동차용 이산화탄소 열펌프 시스템의 성능평가)

  • Kim, Sung-Chul;Park, Jong-Chul;Kim, Min-Soo;Won, Jong-Phil
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.1
    • /
    • pp.37-44
    • /
    • 2008
  • The global warming potential (GWP) of $CO_2$ refrigerant is 1/1300 times lower than that of R134a. Furthermore, the size and weight of the automotive heat pump system can decrease because $CO_2$ operates at high pressure with significantly higher discharge temperature and larger temperature change. The presented $CO_2$ heat pump system was designed for both cooling and heating in fuel cell vehicles. In this study, the performance characteristics of the heat pump system were analyzed for heating, and results for performance were provided for operating conditions when using recovered heat from the stack coolant. The performance of the heat pump system with heater core was compared with that of the conventional heating system with heater core and that of the heat pump system without heater core, and thus the heat pump system with heater core showed the best performance among the selected heating systems. On the other hand, the heating performance of two different types of coolant/air heat pump systems with heater core was compared each other at various coolant inlet temperatures. Furthermore, to use exhausted thermal energy through the radiator, experiments were carried out by changing the arrangement of a radiator and an outdoor evaporator, and quantified the heating effectiveness.

Improvement of Oxidation-resistance of Graphite by Phosphate (인산 에스테르에 의한 탄소재료의 내산화 증진 효과)

  • 김경자;조광연;박윤창;김태관;정윤중;임연수
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.5
    • /
    • pp.555-563
    • /
    • 1999
  • Impregnation of phosphorous additiers into graphite bulk was studied with the goal of enhancing the effectiveness of oxidationprotection. In addition graphite acid washing was carried out prior to the impregnation further to improve oxidation resistance. Observation of the oxidation rate for raw graphite(Raw) impregnated graphite with tri-butyl phsophate on raw block(RP) and impregnated graphite on acid-treated graphite(AP) in air are reported. The phsophorus residue adsorbed on the graphite surface at active sites was determined by FTIR, XRS, TGA techniques. AP with tri-butyl phosphate was found to result in both 30% reduction in oxidation rate at 1000$^{\circ}C$ compared to Raw and increase of 120$^{\circ}C$ in oxidation temperature From the samples of oxidation rate of each specimen in Arrhenius plot it can be said that the present oxidation resistance origninates from the change of chemical reaction modesw neigther by acid-washing treatment nor phsophate impregnation

  • PDF

A Technical Review of Endothermic Fuel Use on High Speed Flight Cooling (흡열연료를 이용한 고속비행체 냉각기술 동향)

  • Kim, Joong-Yeon;Park, Sun-Hee;Chun, Byung-Hee;Kim, Sung-Hyun;Jeong, Byung-Hun;Han, Jeong-Sik
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.2
    • /
    • pp.71-79
    • /
    • 2010
  • As hypersonic flight speeds and engines efficiencies increase, heat loads on an aircraft and it's engine increase. Because the temperature of the air flow is too high to cool the aircraft structure at hypersonic flight speeds, it is essential to use the aircraft fuel as the primary coolant. Endothermic fuels are liquid hydrocarbon aircraft fuels which are able to absorb the heat loads by undergoing endothermic reactions, such as thermal and catalytic cracking. The endothermic reactions are improved by catalysts which change the extent of reaction and product distribution. At high temperature, liquid hydrocarbons would lead to coke formation that can reduce the effectiveness of heat exchanger and cause rapid degradation of the catalyst, thus endothermic capacity of endothermic fuels is limited to the temperature at which coke doesn't form. In this study, the essential cooling technologies by applying endothermic fuels and the properties of the endothermic fuels are described.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF