• Title/Summary/Keyword: air anion

Search Result 73, Processing Time 0.029 seconds

Characteristic Changes on Nonwoven Fabric by Charcoal Printing (숯 날염에 의한 부직포의 특성 변화)

  • ;;;田村照子;小紫朋子
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.2
    • /
    • pp.303-311
    • /
    • 2004
  • The purposes of this study were to investigate characteristic changes on nonwoven fabric by the charcoal printing. It separate grind charcoal as two different size of particles 45-52${\mu}{\textrm}{m}$ and 53-65${\mu}{\textrm}{m}$ for hand screen printing on three kind of nonwoven fabrics. To examine the effect of charcoal printing on nonwoven fabric were to obselve surface changes by a scanning electron microscope, dyeability by using spectrophotometer, moisture regain by oven method, air permeability, anion property, deodoriration and antibacterial activity. The results were as follows: When charcoal powder concentration increased from 3 to 9%, K/S value also increased from 3.06 to 8.55. When charcoal concentration increased, moisture regain also increased. In same concentration, moisture regain occurred higher as particle of small size. Air permeability decreased when the charcoal printing concentration increased. Anion occurrence appeared 140-160ion/cc from three different kinds of nonwoven fabrics in 3% and 9% charcoal concentration. Therefore, occurred anion ineffectively. In concentration of 3%, rate of deodorization measured as 89%, 83% and 87%, and 9% concentration caused 96%, 86% and 93% of high deodorization. Antibacterial activity examination in nonfinished nonwoven fabric resulted range of 60%, however, 3% and 9% concentration finished nonwoven fabric resulted 99.9% of excellent antibacterial activity.

Improvement of Comfortability and Ability on Nonwoven Fabric for Disposable Work Clothing Using Yellow Soil Printing (황토 날염을 이용한 일회용 작업복 소재의 쾌적성 및 기능성 향상에 관한 연구)

  • Jung, Myung-Hee;Park, Soon-Ja;Koshiba, Tomoko;Tamura, Teruko;Shin, Jung-Sook
    • The Research Journal of the Costume Culture
    • /
    • v.15 no.2 s.67
    • /
    • pp.276-283
    • /
    • 2007
  • The purpose of this study were to investigate characteristic changes on nonwoven fabric for disposable work clothes by the yellow soil printing. It separate grind yellow soil as two different size of particles $45\sim52{\mu}m$ and $53\sim65{\mu}m$ for hand screen printing on three kind of nonwoven fabrics. To examine the effect of yellow soil printing on nonwoven fabric were to observe, dyeability by using spectrophotometer, moisture regain by oven method, air permeability, anion property and antibacterial activity. The results were as follows: When yellow soil concentration increased from 5 to 10%, K/S value also increased from 1.05 to 1.88. When yellow soil concentration increased, moisture regain also increased. In same concentration, moisture regain occurred higher as particle of small size. Air permeability decreased when the charcoal printing concentration increased. Anion occurrence appeared $140\sim160ion/cc$ from three different kinds of nonwoven fabrics in 3% and 9% yellow soil concentration. Therefore, occurred anion ineffectively. In concentration of 3%, rate of deodorization measured as 89%, 83% and 87%, and 9% concentration caused 96%, 86% and 93% of high deodorization. Antibacterial activity examination in nonfinished nonwoven fabric resulted range of 60%, however, 3% and 9% concentration finished nonwoven fabric resulted 99.9% of excellent antibacterial activity Surface temperature increased $1.5\sim2^{\circ}C$ by yellow soil finishing.

  • PDF

Effect of Species and Volume Rate of Potted Orchid Plants Put in Closed Chambers on Emission of Air Anions (난의 종류 및 공간대비 투입 비율에 따른 음이온 발생량 구명)

  • Kim, Kwang Jin;Lee, Jong Suk
    • FLOWER RESEARCH JOURNAL
    • /
    • v.16 no.1
    • /
    • pp.85-92
    • /
    • 2008
  • The air anions generated by potted Cymbidium spp., Cymbidium Meglee 'Ms Taipei' Dendrobium phalaenopsis, Oncidium spp., Phalaenopsis spp., and Sedirea japonicum were investigated, and changes of air anion emission were measured as affected by volume rates of potted orchids put in chambers. The volume rates of 20, 40, 60, and 80% for potted Cymbidium spp. and 25, 50, 75, and 100% for potted Cymbidium Meglee 's Taipei'were used in closed chambers. Air anion emission by Cymbidium spp. ($332/cm^3$) and Cymbidium 's Taipei'($323/cm^3$) was the greatest among the tested six orchid species, followed by Dendrobium phalaenopsis ($250/cm^3$), Oncidium spp. ($203/cm^3$), Sedirea japonicum ($119/cm^3$), and Phalaenopsis spp. ($77/cm^3$). Air anion emission by Cymbidium spp. and Cymbidium Meglee 'Ms Taipei'g increased by 40% and 75%, respectively, and thereafter slightly decrease. Therefore, the volume rates of potted plants put in closed chambers should be less than 40% to compare with species and 30% seems most pertinent considering increasing relative humidity in closed chambers. Air anions were generated the greatest amount by potted Cymbidium genera among the orchids tested.

Setting time properties of cement matrix according to photosynthetic bacterial dilution ratio (광합성 세균 희석 비율에 따른 시멘트 경화체의 응결 특성)

  • Pyeon, Su-Jeong;Kim, Dae-Yeon;Lim, Jeong-Jun;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.89-90
    • /
    • 2018
  • In recent years, harmful substances and fine dust in the air are caused by respiratory and cardiovascular diseases through various mechanisms when they are introduced into the human body through respiration, thereby exacerbating human health and causing cancer by prolonged exposure do. In order to prevent such fine dust from being introduced into the room and to improve indoor air quality, improvement of air quality has attracted attention. Among indoor air pollutants, fine dust and CO2 are pollutants that are directly affected by indoor number and activity. The purpose of this study is to evaluate the basic performance of cement matrix using photosynthetic bacteria as a basic study of fine dust and CO2 adsorption type matrix to suppress indoor air pollution and improve air quality.

  • PDF

Positive Charge-doping on Carbon Nanotube Walls and Anion-directed Tunable Dispersion of the Derivatives

  • Shin, Ueon-Sang;Knowles, Jonathan C.;Kim, Hae-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.5
    • /
    • pp.1635-1639
    • /
    • 2011
  • An efficient and novel positive charge-doping on the sidewalls of multi-walled carbon nanotubes has been achieved in the presence of tetrahydrofuran as a dopant and Lewis acidic ionic liquids, [bmim]$Sb_nF_{5n+1}$ (n ${\geq}$ 2; bmim = 1-butyl-3-methylimidazolium), as an activator, leaving air-stable derivatives having positively charged sidewalls and the counter anions, [MWCNT$^{y+}$][SbF$_6^-$]$_y$ (MWCNT = multi-walled carbon nanotube). The derivatization took place very fast in one-pot and under mild reaction conditions. The ionic structure enabled a tunable dissolution of the derivatives in various solvents through anion exchange.

A Study on IT System Design for Eco-Amenity (식물을 이용한 실내공기정화용 정보시스템 설계에 대한 연구)

  • Noh, Yong-Deok;Lee, Jung-Hoon
    • The KIPS Transactions:PartD
    • /
    • v.13D no.7 s.110
    • /
    • pp.971-976
    • /
    • 2006
  • Recently, people is interested in the indoor air pollution because of the well-being life. One of the effective way to remove the air pollutants is to use the eco-friendly houseplants. Eco-friendly houseplants absorb substances out of the stomata in their leaves and improve the indoor environment by plant emission such as phytochemical, anion, etc. In this paper, Eco-Amenity IT system is discussed which provide the data about the eco-friendly plants and related management information depending on the indoor air pollutants.

COD, SS and Turbidity Removal of Paper Wastewater Using DAE(Dissolved Air Flotation) (DAF(Dissolved Air Flotation)를 이용한 제지폐수의 COD, SS 및 탁도 제거)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.4 s.85
    • /
    • pp.246-253
    • /
    • 2005
  • The supernatant treatment of recovery process of raw materials of paper plant was studied using DAF (Dissolved Air Flotation) system. We investigated the removal efficiency (COD, SS and turbidity) of the DAF process. The effects of parameters such as A/S ratio, pressure, flotation conditions, coagulant concentration, mixing conditions, size and ratio of packing and nozzle type were examined. The results showed that the optimum A/S ratio and pressure were 0.058 and 4.5-5 atm, respectively. Injection times of pressurized water around 30 s and flotation times around 10 min appeared to be optimal for the DAF operation. Anion polymer addition improved the removal of COD, SS and turbidity. The smaller size and the more packing ratio were enhanced the removal efficiencies. The order of performance of nozzle was full cone > flat > assemble type.

Concentration and Size Distribution of Atmospheric Particulate Matters, Chloride, Nitrate, and Sulfate Salts in Urban Air (都市大氣중 浮遊粒子狀物質, 鹽化物, 窒酸鹽 및 黃酸鹽의 濃度와 粒經分布)

  • Sohn, Dong-Hun;Heo, Moon-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.3
    • /
    • pp.27-33
    • /
    • 1986
  • Atmospheric particulate matter (A. P. M.) was collected and size-fractionated by an Andersen high-volume air sampler over 15 month period from Jan. 1985 to Feb. 1986 in Seoul. The concentration of chloride, nitrate and sulfate were extracted in an ultrasonic bath and were analyzed by ion chromatography. The annual arithmetical mean of A. P. M. was 128.54 $\mug/m^3$. The concentration of anions were 2.88 $\mug/m^3$ for chloride, 3.86$\mug/m^3$ for nitrate, and 25.44$\mug/m^3$ for sulfate. The content of A. P. M. was lowest in the particle size range 1.1 $\sim 3.3\mum$ and increased as the particle size increased or decreased. And the anions exhibited a seasonal variation in the isize distribution. The contents of anions were higher in winter than summer. Ther ratio of fine particles to the total particles defined by F/T for chloride, nitrate and sulfate. The F\ulcornerT of these anion generally decrease with increasing air temperature. This tendency was prevalent in the chloride and nitrate.

  • PDF

Searching for Anions in the Aerosol around Jeju Samdasu Forest Environments (제주 삼다수 숲길 주변 대기질의 음이온 탐색)

  • Sin, Bang Sik;Lee, Jae H.;Song, Kyu J.;Lee, Hyung H.
    • Journal of Naturopathy
    • /
    • v.10 no.2
    • /
    • pp.114-119
    • /
    • 2021
  • Background: Many anionic phytoncides exist in the forest. Purpose: This study aimed to measure and investigate the number of negative ions in aerosol composition in Samdasu Forest, Jeju. Methods: We counted the number of negative ions in the aerosol with an anion meter at 17 points in the Samdasu forest area. Results: The average number of negative ions measured at 17 points in the aerosol of the Samdasu forest area was 719.7 ions/cm3, the temperature was 25.2℃, the humidity was 80.9%, the altitude was 503 m, and the wind speed was 0.6 m/sec. When looking at the content of anion number in the air quality in order, the highest place was waterfall-entrance-course R-course B- pine forest- course exit> exit wetland. The highest altitude of the collection point was in the order of pine forest-course R-course exit-waterfall-course B- exit wetland-entrance. The elevation difference in elevation was statistically significant. There was no correlation between altitude and anion content. It could be seen that the air quality fluctuates from time to time. Conclusions: A large amount of anionic phytoncide was contained in the air quality in Samdasu Forest in the over results. Therefore, Samdasu Forest is a helpful area as a place to visiting. The visit to the Jeju region, which has a high content of anionic phytoncide, has provided essential information that it has beneficial conditions for health management.

Characteristics of PM2.5 and PM10 Concentration in Pusan Area (부산지역 PM2.5와 PM10의 농도 특성)

  • Kim, Sang-Youl;Cheong, Jang-Pyo;Yi, Seung-Muk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.6
    • /
    • pp.1159-1170
    • /
    • 2000
  • It is necessary to improve the ambient air quality through the proper treatment and control of pollutants by designating air pollutants to regulatory ones. Especially, human took a concern for particulate matters which raised visibility reduction, public health effects and injury of property for urban areas. In order to reduce the effect of particulate matters, we need to establish proper control strategies based on the concentration characteristics of particulate matters. In this study. to evaluate the characteristics of $PM_{2.5}$ and $PM_{10}$. thirty-eight samples of $PM_{2.5}$ and $PM_{10}$ were collected at Nam-Gu sampling site where continuous air monitoring system has been operated, from May, 1999 to November, 1999, and their concentrations for the mass and anion components($Cl^-$, $NO_3{^-}$, $SO_4{^{2-}}$) were analyzed. The important conclusions obtained in this study were as followings. Total average mass concentrations of $PM_{2.5}$ and $PM_{10}$ were 35.016 and $50.293{\mu}g/m^3$ respectively. and $PM_{2.5}/PM_{10}$ ratio was calculated 0.692. Total average concentrations of anion components in $PM_{2.5}$ were $1.581(Cl^-)$, $3.690(NO_3{^-})$ and $12.825(SO_4{^{2-}}){\mu}g/m^3$ and those in $PM_{10}$ were $2.471(Cl^-)$, $5.819(NO_3{^-})$ and $14.414(SO_4{^{2-}}){\mu}g/m^3$ respectively. From the correlations analysis. the correlation coefficient between mass concentration of $PM_{2.5}$ and $PM_{10}$ was calculated as 0.945. The correlation coefficients between $PM_{2.5}$ and anion components were analyzed as $Cl^-$(0.025), $NO_3{^-}$(0.788) and $SO_4{^{2-}}$(0.500) respectively, and the correlation coefficients between $PM_{10}$ and anion components were analyzed as $Cl^-$(-0.019), $NO_3{^-}$(0.806) and $SO_4{^{2-}}$)(0.535) respectively.

  • PDF