• Title/Summary/Keyword: agricultural water

Search Result 7,063, Processing Time 0.036 seconds

A Comparative Considerations of the Moat at the East and West (동.서양 해자(垓字)의 비교 고찰)

  • Jung, Yong-Jo;Park, Joo-Sung;Sim, Woo-Kyung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.3
    • /
    • pp.29-38
    • /
    • 2010
  • A moat is a pond or waterway paved on the outside of a fortress that is one of the facilities to prevent enemy from approaching the fortress wall or classify it as the boundary space, and this study was undertaken to find out the characteristics of the moat that was existed in the East and the West from ancient time to medieval time with the following result. First, the moat in the East was installed of natural moat and artificial moat at the same time while the moat in the West had the fortress built in naturally advantageous site to use natural most substantially more. Second, the moats of Korea were smaller in scale compared to other countries (Japan, China and the Western countries). Third, the fortresses in the East were built to protect towns or royal palace while the West had the fortress to protect the residence of kings, lords, great wealthy persons and the like, and they were used jointly with the natural moat and artificial moat to defend against the infiltration of enemy. Fourth, the Pungsujiri in the Orient is one of the numerous ideologies forming the supplementary ideologic system of Korean people that could not be denied as the perception that influences on Korean people after the Silla Dynasty, and this Pungsujiri was considered when determining the location of the castle. The moat surrounding the castle had the role to keep the good energy in the castle from escaping away. Fifth, the Ha-Ha technique in the west was designed to prevent the external power from infiltration by digging the ditch on the place applicable to the boundary of the garden site, rather than the fence. While walking around along the water-side path without knowing the existence of this ditch, when the road is discovered with the cut off in the ditch, people had the exclamation without actually recognizing such astonishment. It was originally the dike for military purpose during the medieval time that was designed to look into the garden without physical boundary surrounded with the vertical fence in the garden that by having the deep ditch like shape on the boundary line of the garden which was designed to form the farm by preventing various types of cattle from coming inside the garden and bring in the garden element for farms, forestry, agricultural land and the like.

A Study on the Improvement of Treatment Efficiency for Nitrogen and Phosphorus by Improved Sewage Treatment Process in Constructed Wetland by Natural Purification Method (자연정화공법에 의한 인공습지 하수처리장에서 하수처리 공정개선에 따른 질소 및 인의 처리효율 향상 방안)

  • Seo, Dong-Cheol;Park, Woo-Young;Lim, Jong-Sir;Park, Chan-Hoon;Lee, Hong-Jae;Kim, Hong-Chul;Lee, Sang-Won;Lee, Do-Jin;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.1
    • /
    • pp.27-34
    • /
    • 2008
  • To effectively treat the domestic sewage that was produced on a small-scale in farming and fishing village in order to encourage an ecologically friendly environment, a small-scale sewage treatment apparatus using natural purification methods that consisted of an aerobic and an anaerobic plots were constructed. The efficiency of sewage treatment according to the sewage loading was investigated to obtain the optimum sewage loading in small-scale sewage treatment apparatus. Removal rate of pollutants according to the sewage loading were in the order of $150\;Lm^{-2}day^{-1}{\fallingdotseq}300\;Lm^{-2}day^{-1}>600\;Lm^{-2}day^{-1}$. Therefore, the optimum sewage loading was 300 L m-2 day-1. Under the optimum sewage loading, removal rate of BOD, $COD_{Mn}$, turbidity, T-N and T-P were 99, 94, 99, 49 and 89%, respectively. However, to satisfy the water quality standard in effluent in small-sclae sewage treatment apparatus for domestic sewage treatment, the low removal efficiency of T-N and T-P must be improved. So to improve the removal rate of T-N and T-P, the efficiency of sewage treatment according to the improved sewage treatment process such as, re-treatment at aerobic plot, anaerobic condition of aerobic plot, changing the filter media sizes and the depths in anaerobic plot, and also addition of oyster shells to filter media at anaerobic plot were investigated. In case of 150 cm depth in anaerobic plot with filter medium A (effectivity particle size 1.50 mm) and addition of oyster shells to filter media at anaerobic plot, removal rate of T-N and T-P in both plots were increased by 10 and 3%, and 14 and 7% in comparison with 100 cm depth in anaerobic plot with filter medium B(effectivity particle size 0.95 mm), respectively. The optimum improved sewage treatment process in small-scale sewage treatment apparatus were 150 cm depth in anaerobic plot with filter medium A and addition of oyster shells to filter media at anaerobic plot.

Study on Morphological Characteristics of Rice Soils in Mangeong-Dongjin and Yeongsan Watersheds (영산강(榮山江)과 만경(萬頃)·동율강유역(東律江流域)의 답토양분포(畓土壤分布)에 관(關)하여)

  • Kim, Han-Myoung;Cho, Guk-Hyun;Yoo, Chul-Hyun;Eun, Mu-Young;Rho, Sung-Pyo;Shin, Yong-Hwa
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.17 no.2
    • /
    • pp.125-133
    • /
    • 1984
  • To obtain the basic date for the improvement of cultural and managemental problems caused by soil characteristics and soil productivity in rice cultivation of Honam area, morphological characteristics of rice soils were investigated in Mangeng-Dongjin and Yeongsan Water-sheds, and compaired differences between two major Watersheds. The results obtained are summarized as follows: 1. According to U.S.D.A. Soil Taxonomy Classification System, eight great groups are distributed in rice soils of two major Watersheds. More than 50% of rice paddy soils are classified as Haplaquepts. 2. Two Watersheds are quite different in soil parent materials. In Mangeong-Dongjin Watershed, most soils (55.1%) are derived from fluvic-marine deposits. Remainders are derived from local alluvium (24.7%) and alluvium (14.2%). But in Yeongsan Watershed, the order is local alluvium>alluvium>fluvio-marine deposits. 3. Rice soils occur mostly in coastal and inland flat-site with the slope of less than 2% (57.8%) in Mangeong-Dongjin Watersheds. However, in Yeongsan Watershed, flat-site and low undulating terrace are mostly distributed (52.9%). 4. About 81.9, 61.4 and 53.3% of rice soils are classified as fine textured in Yeongsan, Dongjin, and Mangeong Watersheds, respectively. 5. More normal paddy soils and less sandy paddy soils are distributed in Yeongsan Watershed. The results indicate that more rice soils are classified as productivity classes of I and II in Yeongsan Watershed than in Mangeong-Dongjin Watersheds.

  • PDF

Evaluation on Heating Effects of Geothermal Heat Pump System in Farrowing House (지열 난방시스템을 이용한 분만돈사의 난방효과 분석)

  • Choi, H.C.;Park, Jae-Hong;Song, J.I.;Na, J.C.;Kim, M.J.;Bang, H.T.;Kang, H.G.;Park, S.B.;Chae, H.S.;Suh, O.S.;Yoo, Y.S.;Kim, T.W.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.205-215
    • /
    • 2010
  • Geothermal heat pump system (GHPS) is an energy-efficient technology that use the relatively constant and renewable energy stored in the earth to provide heating and cooling. With the aim of using GHPS as a heating source, it's possibilities of application in farrowing house were examined by measuring environmental assessment and sow's performance. A total of 96 sows were assigned to 2 pig housings (GHPS and conventional housing) with 48 for four weeks in winter season. During the experimental period, indoor maximum temperature in GHPS-housing was measured up to $26.7^{\circ}C$, average temperature could maintain $21.2^{\circ}C$. The mean value of dust levels and $CO_2$, $NH_3$ and $H_2S$ gas emissions were decreased in GHPS-housing compare with those of conventional housing. Litter size, birth weight, parity and weaning weight did not differ between housings. However, feed intake of sow in GHPS-housing was lower than that of conventional housing. In energy consumption for heating, electric power consumption increased in GHPS-housing than the conventional housing, a 2,250 kwh increase, whereas there is no fuel usage for heater in GHPS-housing. Amount of ground water circulated for heating in cold weather for earth heat exchanger was 8.4-12.9 ton per day. In conclusion, GHPS may have environmental benefits and effectiveness of heating in farrowing housing and affect the performance in sows.

Microbiological Hazard Analysis for HACCP System Application to Non Heat-Frozen Carrot Juice (비가열냉동 당근주스의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Lee, Ung-Soo;Kwon, Sang-Chul
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.79-84
    • /
    • 2014
  • This study has been performed for about 270 days at analyzing biologically hazardous factors in order to develop HACCP system for the non heat-frozen carrot juice. A process chart was prepared by manufacturing process of raw agricultural products of non heat-frozen carrot juice, which was contained water and packing material, storage, washing, cutting, extraction of the juice, internal packing, metal detection, external packing, storage and consignment (delivery). As a result of measuring Coliform group, Staphylococcus aureus, Salmonella spp., Bacillus cereus, Listeria Monocytogenes, Enterohemorrhagic E. coli before and after washing raw carrot, Standard plate count was $4.7{\times}10^4CFU/g$ before washing but it was $1.2{\times}10^2CFU/g$ detected after washing. As a result of testing airborne bacteria (Standard plate count, Coliform group, Yeast and Fungal) depending on each workplace, number of microorganism of in packaging room, shower room and juice extraction room was detected to be 10 CFU/Plate, 60 CFU/Plate, 20 CFU/Plate, respectively. As a result of testing palm condition of workers, as number of Standard plate count, Coliform group and Staphylococcus aureus was represented to be high as $6{\times}10^4CFU/cm^2$, $0CFU/cm^2$ and $0CFU/cm^2$, respectively, an education and training for individual sanitation control was considered to be required. As a result of inspecting surface pollution level of manufacturing facility and devices, Coliform group was not detected in all the specimen but Standard plate count was most dominantly detected in scouring kier, scouring kier tray, cooling tank, grinding extractor, storage tank and packaging machine-nozzle as $8.00{\times}10CFU/cm^2$, $3.0{\times}10CFU/cm^2$, $4.3{\times}10^2CFU/cm^2$, $7.5{\times}10^2CFU/cm^2$, $6.0{\times}10CFU/cm^2$, $8.5{\times}10^2CFU/cm^2$ respectively. As a result of analyzing above hazardous factors, processing process of ultraviolet ray sterilizing where pathogenic bacteria may be prevented, reduced or removed is required to be controlled by CCP-B (Biological) and critical level (critical control point) was set at flow speed is 4L/min. Therefore, it is considered that thorough HACCP control plan including control criteria (point) of seasoning fluid processing process, countermeasures in case of its deviation, its verification method, education/training and record control would be required.

Effect of Sasa Borealis and White Lotus Roots and Leaves on Insulin Action and Secretion In Vitro (In vitro에서 조릿대, 연근과 연잎이 인슐린 작용 및 분비에 미치는 영향)

  • Ko, Byoung-Seob;Jun, Dong-Wha;Jang, Jin-Sun;Kim, Ju-Ho;Park, Sun-Min
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.1
    • /
    • pp.114-120
    • /
    • 2006
  • Anti-diabetic effects of extracts and fractions of Sasa borealis (SB), white lotus roots (LR) and leaves (LL), and their mixture were determined in 3T3-L1 adipocytes and Min6 cells by investigating insulin-sensitizing activity and glucose-stimulated insulin secretion, respectively. SB, LR, LL, and mixture of SB, LR, and LL (3 : 2 : 3) were extracted using 70% ethanol, and m mixture extract was fractionated by XAD-4 column chromatography with serial mixture solvents of methanol and water. Fractional extractions were utilized for anti-diabetic effect assay. SB and LR extracts increased insulin-stimulated glucose uptake, but not as much as mixture of SB, LR, and LL. Significant insulin-sensitizing activities of 20 and 80% methanol fractions of SB, LR, and LL mixture extract were observed in 3T3-L1 adipocytes, giving 0.5 or $5\;{\mu}g/mL$ each fraction with 0.2 nM insulin to attain glucose uptake level similar to that attained by 10 nM insulin alone. Similar to pioglitazone, peroxisome proliferators-activated $receptor-{\gamma}\;(PPAR-{\gamma})$ agonist, 20 and 80% methanol fractions increased adipocytes by stimulating differentiation from fibroblasts and triglyceride synthesis. LL extract and 20, 60, and 80% methanol fractions of the mixture suppressed ${\alpha}-amylase$ activity, but did not modulate insulin secretion capacity of Min6 cells in both low and high glucose media. These data suggest 20 and 80% methanol tractions contain potential insulin sensitizers with functions similar to that of $PPAR-{\gamma}$ agonist. Crude extract of SB, LR, and LL mixture possibly improves glucose utilization by enhancing insulin-stimulated glucose uptake and inhibiting carbohydrate digestion without affecting insulin secretion in vivo.

Influence of $SiO_2$ Treatment on Guttation in Rice Seedlings Stage (규산(珪酸)이 수도(水稻) 유묘(幼苗)의 일액(溢液)에 미치는 영향(影響))

  • Jeh, Sang Yull;Choi, Jang Soo
    • Current Research on Agriculture and Life Sciences
    • /
    • v.4
    • /
    • pp.1-6
    • /
    • 1986
  • This study was conducted to find out the effect of $SiO_2$ treatment on the $SiO_2$ concentration in guttation liquid, the amount of guttation liquid exudated from the margin of rice leaves, and the relationships between $SiO_2$ concentration in guttation liquid and foliar burn during the rice seedling stage, using two rice varieties;Nagdong-byeo (a Japonica) and Samgang-byeo (a - Indica - Japonica hybrid). Seedlings were cultivated in water solution and enveloped in polyvinyl case ($50cm{\times}150cm{\times}70cm$). $SiO_2$ treatment increased the amount of guttation liquid, the amount of guttation liquid (Nagdong-byeo:4.30mg/plant, Samgang-byeo:4.34mg/plant)) treated with 200ppm of $SiO_2$ was greater than any other level, decreased over 200ppm of $SiO_2$. $SiO_2$ concentration in guttation liquid was increased as application rates of $SiO_2$ increased, showing the positive correlation, and $SiO_2$ in guttation liquid/$SiO_2$ in culture ratio decreased over 100ppm of $SiO_2$. The highest concenitration of $SiO_2$ (Nagdong-byeo:172.6ppm/lcc, Samgang-byeo:199.8ppm/lcc) in guttation liquid was obtained at 12 hrs after $SiO_2$ applied. Foliar burn seemed to be closely related with $SiO_2$ concentration in guttation liquid.

  • PDF

Key Methodologies to Effective Site-specific Accessment in Contaminated Soils : A Review (오염토양의 효과적 현장조사에 대한 주요 방법론의 검토)

  • Chung, Doug-Young
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.4
    • /
    • pp.383-397
    • /
    • 1999
  • For sites to be investigated, the results of such an investigation can be used in determining foals for cleanup, quantifying risks, determining acceptable and unacceptable risk, and developing cleanup plans t hat do not cause unnecessary delays in the redevelopment and reuse of the property. To do this, it is essential that an appropriately detailed study of the site be performed to identify the cause, nature, and extent of contamination and the possible threats to the environment or to any people living or working nearby through the analysis of samples of soil and soil gas, groundwater, surface water, and sediment. The migration pathways of contaminants also are examined during this phase. Key aspects of cost-effective site assessment to help standardize and accelerate the evaluation of contaminated soils at sites are to provide a simple step-by-step methodology for environmental science/engineering professionals to calculate risk-based, site-specific soil levels for contaminants in soil. Its use may significantly reduce the time it takes to complete soil investigations and cleanup actions at some sites, as well as improve the consistency of these actions across the nation. To achieve the effective site assessment, it requires the criteria for choosing the type of standard and setting the magnitude of the standard come from different sources, depending on many factors including the nature of the contamination. A general scheme for site-specific assessment consists of sequential Phase I, II, and III, which is defined by workplan and soil screening levels. Phase I are conducted to identify and confirm a site's recognized environmental conditions resulting from past actions. If a Phase 1 identifies potential hazardous substances, a Phase II is usually conducted to confirm the absence, or presence and extent, of contamination. Phase II involve the collection and analysis of samples. And Phase III is to remediate the contaminated soils determined by Phase I and Phase II. However, important factors in determining whether a assessment standard is site-specific and suitable are (1) the spatial extent of the sampling and the size of the sample area; (2) the number of samples taken: (3) the strategy of taking samples: and (4) the way the data are analyzed. Although selected methods are recommended, application of quantitative methods is directed by users having prior training or experience for the dynamic site investigation process.

  • PDF

Application of Reduce Tillage with a Strip Tiller and its Effect on Soil Erosion Reduction in Chinese Cabbage Cultivation (배추 재배에 있어 경운방법에 따른 작업효율성 및 토양유실 특성 평가)

  • Lee, Jeong-Tae;Lee, Gye-Jun;Ryu, Jong-Soo;Hwang, Seon-Woong;Park, Suk-Hoo;Zhang, Yong-Seon;Jeong, Yeong-Sang
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.6
    • /
    • pp.970-976
    • /
    • 2011
  • Strip tiller equipment was developed to reduce soil erosion in the slope land for highland agricultural area. The equipment consisted of 4 rows strip tillage device and fertilizer applicator. The field was tilled in 10 cm width and in 10 cm depth by the equipment, of which tilled surface was 16.7% of full-width tillage. The working time and fuel consumption of the equipment were $3.8hours\;ha^{-1}$ and $24.4L\;ha^{-1}$ respectively, which were 59% and 74% less than those of the conventional tillage. Fertilizer efficiency of the equipment in cultivation of Chinese cabbage was 1.7, 1.6 and 1.5 times higher in nitrate, phosphorous and potassium respectively, than conventional tillage. When the equipment was used after covering of rye residue, the quantity of runoff was 49~67% lower than the conventional tillage. And the quantity of soil loss were 1.3 and $0.2Mg\;ha^{-1}$ at right after and 30 days after planting of Chinese cabbage respectively, while 11.5 and $4.1Mg\;ha^{-1}$ in conventional tillage. In conclusion, the strip tillage equipment developed in this study can be applicable to slope land, so that soil loss of 90% can be reduced.

Investigations of Soil Chemical Properties in the Cultivation Fields of Rubus coreanus with Different Growth Ages (복분자 재배 기간에 따른 토양의 화학적 특성 변화)

  • Lee, Jin-Ho;Lee, Chang-Ho;Kang, Byeong-Suk;Ahn, Byung-Koo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.6
    • /
    • pp.923-929
    • /
    • 2010
  • This study was conducted to investigate the relations between soil chemical properties and Korean raspberry (Rubus coreanus Miq.) growth. Soils were collected from 54 sampling sites in 1 to 6 years old Korean raspberry cultivation fields (RCFs) at Gochang-gun, Jeollabuk-Do, Korea. In RCF with two to six years old plants, soil pH and exchangeable $Ca^{2+}$ and $Mg^{2+}$ contents were higher at the leaf-emergence time, but EC, available phosphorus content, CEC, and total nitrogen content were higher at the harvesting time; especially at the harvesting time, the content of available phosphorus in the RCF with 3~6 years old plants were at least three times higher than in the RCF with 2 years old plants. Water-soluble anions ($Cl^-$, ${NO_3}^-$, ${PO_4}^{2-}$, and ${SO_4}^{2-}$) in the RCF were also measured. The contents of ${NO_3}^-$ and ${SO_4}^{2-}$ were always higher in the RCF with older plants than in the RCF with younger plants, which were not affected by sampling time and sampling locations (rhizosphere and non-rhizosphere sites). However, soils collected from non-rhizosphere at the leaf-emergence time contained higher ${PO_4}^{2-}$ content, but $Cl^-$ content was higher in the soils collected from rhizosphere at the harvesting time. In general, soils in the RCFs contained excess amounts of inorganic nutrients such as available phosphorus and exchangeable $K^+$. Thus, optimal levels of soil properties for Korean raspberry cultivation should be reconsidered.