소형디젤엔진용 산화촉매에 의한 미 규제 배출가스 저감특성에 관한 연구 (A Study of Unregulated Emission Reduction Characteristics by Diesel Oxidation Catalyst (DOC) for Light-Duty Diesel Engine)

  • 김기호;안균재;강금원;이성욱;엄동섭;이태영
    • 한국자동차공학회논문집
    • /
    • 제14권2호
    • /
    • pp.145-150
    • /
    • 2006
  • Recently emission regulation on diesel vehicles is getting stringent and research on aftertreatment technology such as DPF and DOC has been carried out actively. Even though PM(Particulate matters) reduction efficiency in DOC is relatively low but the structure is simpler and very effective in the reduction of gas materials and unregulated materials. Therefore it has been applied to smaller diesel vehicles. The aims of this research is to investigate the emission reduction characteristics of DOC; DOC performance of regulated and unregulated material emission reduction. It results a Pt based catalyst demonstrated higher emission reduction efficiency than a Pt-V based catalyst in CVS-75 mode, and also the reduction efficiency of unidentified material was excellent.

DC 저온플라즈마를 이용한 디젤엔진 유해 배기가스 저감에 관한 실험적 연구 (The Experimental Study on the Removal of Diesel Engine Pollutant Emissions Using DC Non-Thermal-Plasma(NTP))

  • 채재우;황재원;정지용;한정희;황화자;김석
    • 한국자동차공학회논문집
    • /
    • 제9권2호
    • /
    • pp.35-42
    • /
    • 2001
  • The diesel engine exhaust gas is know as one of the causes to produce photochemical smog, which causes damage on environmental. However, due to the high thermal efficiency and low carbon dioxide emission, the usage of a diesel engine is prevailed. In this study, the DC non-thermal plasma technology used to the particulate matter (PM) aftertreatment. The exhaust gas characteristics and energy density were investigated on the dynamometer test bed and chassis dynamometer with CVS-75 mode in a passenger diesel car. It was reported that the smoke removal efficiency has around the 70% in the dynamometer test with 80W energy consumption and the PM removal efficiency has the 68% in the real car test. The NOx also reduced the 20% according to electrode type respectively. Considering these results, plasma technology is one of the ways to simultaneously removing method the particulate matter (PM) and NOx.

  • PDF

Urea-Formaldehyde 수지가공포에 있어 Resorcinol의 유리 Formaldehyde 포착효과 (Effect of Resorcinol as Free Formaldehyde Scavenger for Fabric Finished with Urea-formaldehyde Precondensate.)

  • Kang, In-Sook;Kim, Sung-Reon
    • 한국염색가공학회지
    • /
    • 제9권2호
    • /
    • pp.41-49
    • /
    • 1997
  • To control free formaldehyde release from fabric finished with N-methylol compounds, resin finished cotton fabric was treated with resorcinol solution, dried and cured. Factors affecting to control formaldehyde release have been investigated. It was shown that the aftertreatment with resorcinol greatly suppressed the free formaldehyde release. Up to concentration of about 5% of resorcinol, the concentration of resorcinol effected on the control of free and evolved formaldehyde. And at high concentration of resorcinol, however, the concentration became rather insensitive to contol formaldehyde release. Addition of some salt catalysts such as ammonium chloride, zinc nitrate, sodium acetate and ammonium acetate, was effective in decreasing formaldehyde release. Considering the effect on the control of formaldehyde and crease recovery, ammonium acetate was concidered to be the best catalyst. It was observed that the optimum curing temperature for the resorcinol treatment was about 15$0^{\circ}C$, and that the curing time did not affected formaldehyde release over three minutes. Although the treatment of resorcinol had a little adverse effect on crease recovery of resin finished fabric, this effect could be negligible.

  • PDF

소형디젤산화촉매의 배출가스 성능평가 (The evaluation of diesel emission reduction characteristics by DOC in light-duty vehicle)

  • 엄명도;류정호;임철수
    • 한국자동차공학회논문집
    • /
    • 제7권8호
    • /
    • pp.34-42
    • /
    • 1999
  • In late 1997, the portion of registered light-duty diesel vehicle was 25.3% and its emission rate was 17.1% in Korea. Especially, diesel particulate matters(DPM) and NOx are hazardous air pollutants to human health and environment in urban area. The reduction technologies of exhaust emissions from diesel engines are improvement of engine combustion, fuel quality and development of diesel exhaust after treatment , In this study , a light-duty diesel oxidation catalyst(DOC) that is one of the diesel exhaust after treatment was made for performance evaluation and the emission characteristics were tested on CVS-75 mode. And the analysis of the particle size distribution with scanning mobility particle 100, 67.6% and 66.7, 10.0% for Pt and Pt-V catalyst .And for Pt catalyst, the PM increased 7.8% because of increasing sulfate but Pt-V catalyst reduced the PM to 23.0% . Test results of particle size distribution showed that peak values of number and mass densities are respectively 100∼200nm their distribution trend independent of vehicle speed.

  • PDF

모사 배기관 내 HC-DeNOx 촉매용 인젝터의 분무 거동 특성 (Spray Behavior Characteristics of Injector Used for HC-DeNOx Catalyst System in the Transparent Exhaust Manifold)

  • 이동훈;오정모;정해영;이기형;여권구
    • 한국자동차공학회논문집
    • /
    • 제15권4호
    • /
    • pp.54-60
    • /
    • 2007
  • A new method that optimizes a control of hydrocarbon (HC) addition to diesel exhaust gas for HC type DeNOx catalyst system has been developed. These catalysts are called as the HC-DeNOx catalyst in this paper. The system using HC-DeNOx catalyst requires a resonable quantity of hydrocarbons addition in the inlet gas of the catalyst, because the HC concentration in a diesel engine is so low that the HC is not sufficient for NOx conversion. Generally ambient temperature in the exhaust manifold is $250{\sim}350^{\circ}C$, so spray behavior in this case is different from that of any other condions. This research shows spray behavior of injected hydrocarbons in the transparent exhaust manifold.

후처리장치 부착에 따른 대형디젤엔진의 입자 배출특성 (Particle Emission Characteristics of Heavy-duty Diesel Engine using Aftertreatment Systems)

  • 권상일;박용희
    • 한국분무공학회지
    • /
    • 제17권3호
    • /
    • pp.146-151
    • /
    • 2012
  • This study was primarily focused on the experimental comparison of the particle emission characteristics for heavy duty engine. PM and particle number from various heavy duty engines and DPF type were analyzed with a golden particle measurement system recommended by the Particle Measurement Program. And the repeatability and reproducibility between test mode was analyzed. This study was conducted for the experimental comparison on particulate emission characteristics between the European and World-Harmonized test cycles for a heavy-duty diesel engine. To verify the particulate mass and particle number concentrations from various operating modes, ETC/ESC and WHTC/WHSC, both of which will be enacted in Euro VI emission legislation, were evaluated. Real-time particle formation of the transient cycles ETC and WHTC were strongly correlated with engine operating conditions and after-treatment device temperature. A higher particle number concentration during the ESC mode was ascribed to passive DPF regeneration and the thermal release of low volatile particles at high exhaust temperature conditions.

48-볼트 가솔린 하이브리드 차량 초기 시동 시 배기 정화 성능 분석을 위한 1차원 전기 히터 촉매 해석 모델 개발 (Development of a One-dimensional Numerical Model of the Electrically Heated Three-Way Catalyst For Start-up Heating in a 48-V Gasoline Hybrid Vehicle)

  • 김성수;김정환
    • 한국분무공학회지
    • /
    • 제28권3호
    • /
    • pp.150-155
    • /
    • 2023
  • Cold-start emissions are given great importance under the Euro-7 emission standard due to their significant impact on overall vehicle emissions. When an engine is started from a cold state, the combustion process is not yet optimized, leading to higher emissions. Hybrid vehicles, in particular, may face additional challenges, as their engine may remain inactive for extended periods, causing their catalysts to cool down and potentially become less effective in reducing emissions. In the present study, the performance of an electric heater was investigated as a means to enhance the catalyst heating during the start-up time. A simulation tool was utilized to develop a model for the gasoline exhaust aftertreatment system. The result indicates that the heater was able to increase the three-way catalyst temperature to 500℃ in 4 s using 20 kW power. In addition, the implementation of a secondary air supply resulted in reduced temperature overshoot and improved conversion efficiencies.

Urea-SCR 분사시스템의 DeNOx 저감 성능 향상과 NH3 슬립저감을 위한 모델 기반 제어알고리즘 개발 및 구현 (The Development and Implementation of Model-based Control Algorithm of Urea-SCR Dosing System for Improving De-NOx Performance and Reducing NH3-slip)

  • 정수진;김우승;박정권;이호길;오세두
    • 한국자동차공학회논문집
    • /
    • 제20권1호
    • /
    • pp.95-105
    • /
    • 2012
  • The selective catalytic reduction (SCR) system is a highly-effective aftertreatment device for NOx reduction of diesel engines. Generally, the ammonia ($NH_3$) was generated from reaction mechanism of SCR in the SCR system using the liquid urea as the reluctant. Therefore, the precise urea dosing control is a very important key for NOx and $NH_3$ slip reduction in the SCR system. This paper investigated NOx and $NH_3$ emission characteristics of urea-SCR dosing system based on model-based control algorithm in order to reduce NOx. In the map-based control algorithm, target amount of urea solution was determined by mass flow rate of exhaust gas obtained from engine rpm, torque and $O_2$ for feed-back control NOx concentration should be measured by NOx sensor. Moreover, this algorithm can not estimate $NH_3$ absorbed on the catalyst. Hence, the urea injection can be too rich or too lean. In this study, the model-based control algorithm was developed and evaluated on the numerical model describing physical and chemical phenomena in SCR system. One channel thermo-fluid model coupled with finely tuned chemical reaction model was applied to this control algorithm. The vehicle test was carried out by using map-based and model-based control algorithms in the NEDC mode in order to evaluate the performance of the model based control algorithm.

악관절 폐구성 과두걸림 환자의 하악운동에 관한 연구 -치료전후의 하악운동 범위 및 양상 - (A Study on the Mandibular Movements in the Patients with TMJ Lock Closed -Range and pattern of mandibulr movement-)

  • Sung-Chang Chung;Hyung-Suk Kim
    • Journal of Oral Medicine and Pain
    • /
    • 제16권1호
    • /
    • pp.113-120
    • /
    • 1991
  • The authors examined the patterns and various ranges of mandibular movements in TMJ lock closed patients in the frontal, sagittal and horizontal plane pre-end post-treatment. And the author obtained the following results. 1. In the frontal plane, the patterns and ranges of mandibular movement of the patients were very irregular and small before treatment. But after the treatment, the patterns were similar to the typical shield shape of the normal subjects. And the velocity of opening and closing was improved after the treatment. 2. In the sagittal plane, the mean amount of maximum mouth opening was 27.0±4.0mm before treatment and 44.0±5.4mm after treatment. And there was statistically significant improvement(p<0.005). The patterns of the movement were very irregular and small before treatment, but were similar to the shape of "Posselt's envelope of motion" after the treatment. The velocity of opening and closing was improved after the treatment 3. In the horizontal plane, the mean amount of maximum laterotrusion was 8l2±2.5mm in the affected side and 6.7±2.2mm in the non-affected side before treatment. There was a significant difference between the sides(p<0.05). After the treatment, the mean was 10.4±2.6mm in the affected side and 8.9±2.3mm in the non-affected side and there was no significant difference between the sides(p>0.05). There was no significant difference in the mean amount of maximum protrusion between the before and aftertreatment(p>0.05), but the patterns of the movements were improved.

  • PDF

A Study on Numerical Simulation of Gaseous Flow in SCR Catalytic Filter of Diesel Exhaust Gas Aftertreatment Device

  • Bae, Myung-Whan;Syaiful, Syaiful;Mochimaru, Yoshihiro
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권3호
    • /
    • pp.360-368
    • /
    • 2010
  • A SCR catalytic filter system is used for reducing $NO_x$ and soot emissions simultaneously from diesel combustors. The amount of ammonia (as a reducing agent) must be controlled with the amount of $NO_x$ to obtain an optimal $NO_x$ conversion. Hence, gas mixing between ammonia and exhaust gases is vital to ensure that the SCR catalyst is optimally used. If ammonia mass distribution is not uniform, slip potential will occur in rich concentration areas. At lean areas, on the other hand, the catalyst is not fully active. The better mixing is indicated by the higher uniformity of ammonia mass distribution which is necessary to be considered in SCR catalytic filter system. The ammonia mass distributions are depended on the flow field of fluids. In this study, the velocity field of gaseous flow is investigated to characterize the transport of ammonia in SCR catalytic filter system. The influence of different injection placements on the ammonia mass distribution is also discussed. The results show that the ammonia mass distribution is more uniform for the injector directed radially perpendicular to the main flow of inlet at the gravitational direction than that at the side wall for both laminar (Re = 640) and turbulent flows (Re = 4255). It is also found that the mixing index decreases as increasing the heating temperature in the case of ammonia injected at the side wall.