• Title/Summary/Keyword: after-glow

Search Result 91, Processing Time 0.029 seconds

Optical Sensitivity of TL Glow Peaks Separated Using Computerized Glow Curve Deconvolution for RTL Quartz

  • Kim, Myung-Jin;Kim, Ki-Bum;Hong, Duk-Geun
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.3
    • /
    • pp.114-119
    • /
    • 2018
  • Background: The retrospective dosimetry using RTL quartz can be improved by information for an optical sensitivity of sample connected with the equivalent dose determination. Materials and Methods: The quartz sample from a volcanic rock of Japan was used. After correcting the thermal quenching effect, RTL peaks of quartz were separated by the CGCD method cooperated with the general order kinetics. The number of overlapped glow peaks were ascertained by the $T_m-T_{stop}$ method. The optical sensitivity was examined by comparing the change of intensity on RTL glow peaks measured after exposure to light from a solar simulator with various illumination times. Results and Discussion: Seven glow peaks appeared to be overlapped on the RTL glow curve. The general order kinetics model was appropriate to separate glow peaks. After exposure to light from a solar simulator from a few minutes to 416 hr, the signals for peaks P4 and P5 decayed following the form of $f(t)=a_1e^{-{\lambda}1t}$, while the signals for peaks P6 and P7 decayed by the form of $f(t) = a_1e^{-{\lambda}1t}+a_2e^{-{\lambda}2t}+a_3e^{-{\lambda}3t}$. Conclusion: For dosimetric peaks, the times taken to reduce the RTL signal to half of its initial value were 70 sec for the peak P4, 54 s for the peak P5, 9,840 sec for the peak P6 and 26,580 sec for the peak P7, respectively. We conclude that the optical sensitivity of peaks P4, and P5 gives much higher than that of peaks P6 and P7.

Thermoluminescence (TL) of Minerals Separated from Irradiated Mussel

  • Yi, Sang-Duk;Oh, Man-Jin
    • Preventive Nutrition and Food Science
    • /
    • v.10 no.1
    • /
    • pp.17-21
    • /
    • 2005
  • This study was carried out to determine whether detection of minerals separated from irradiated mussel could be could be done by thermoluminescence (TL) method. After the minerals were separated by sodium polytungstate solution (2.0 g/mL) from irradiated mussel, organic compounds remaining in the minerals were removed by acid-base treatment and dried at 50℃ overnight, and then the minerals were measured through TL. The TL intensities of separated minerals at different irradiation doses during storage conditions of room and darkroom were obtained. TL intensity of first glow curves for minerals separated from irradiated mussel showed linear increase from the control to 5 kGy and slight increase from 5 kGy to 10 kGy. Since glow curve ratios of G2, G3 and G4, calculated from re-irradiated minerals measured immediately after irradiation and after storage of three months were over 0.5, detection of irradiation was possible. G1, which showed the glow curve ratios above 0.1, was classified as non-irradiated samples because the unique first glow curve was not found within the recommended temperature interval (150-230℃). Hence, on the basis of TL intensity, and glow curve ratio and shape, it is possible to correctly identify irradaited mussels after mineral separation during storage.

Changes in Thermoluminescence of Mineral Separated from Irradiated Shellfish under Various Storage Conditions

  • Yi, Sang-Duk;Yang, Jae-Seung
    • Preventive Nutrition and Food Science
    • /
    • v.6 no.1
    • /
    • pp.23-28
    • /
    • 2001
  • A study was carried out to establish a detection method of irradiated shellfish through thermoluminescence (TL). The TL intensity of first glow curves for irradiated bloody, freshwater, and short-neck shellfish increased from control until 5 kGy and increased slightly room 5 kGy until 10 kGy. Maximum TL temperatures of all irradiated samples tested were below 23$0^{\circ}C$, within temperature interval of 150~25$0^{\circ}C$ recommended for evaluation. Since just in control, glow curve ratios of G3 and G4 calculated from re-irradiated (1 kGy) bloody, freshwater and shortneck were over 0.5, detection in control was possible. However, as glow curve ratios after three months were below 0.5, detection by glow curve ratios after three months was impossible. Gl, which calculated from unirradiated samples, exhibited below 0.1, they were classified as unirradiated. In all samples, all the irradiated shellfish could be classified correctly as irradiated by hemaximum TL temperatures and shape of the second glow curve because those were shown in a lower temperature region than those of the first glow curve.

  • PDF

After-glows in $N_2$ RF Flowing Plasma

  • Lee, Min-Uk;O, Su-Gi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.489-489
    • /
    • 2012
  • The vibrational distribution of $N_2$ (B, v') in after-glows in $N_2$ RF flowing plasma was investigated. The optical emission of the after-glow was studied as function of distance from plasma. In a tube 2.1 cm, the gas pressure varied 8 Torr with 1000sccm nitrogen gas flowing late.. The discharges were excited by two ring-electrode powered by RF 13.56 MHz 100 Watt. $N_2$ (B, v') vibrational distribution was analyzed to see depends of position in after-glow. Dissociation rate of $N_2$ varied showing maximum in the late after-glow region. We studied $N_2$ RF capacitive flowing plasmas and afterglows by emission spectroscopy and by NO titration to determine the density of N-atoms.

  • PDF

Optical and Long After-Glow Characteristics of $Eu^{2+}$, $Nd^{3+}$ doped $BaAl_{2}O_{4}$ Phosphorescent Crystals (($Eu^{2+}$, $Nd^{3+}$를 도핑시킨 $BaAl_{2}O_{4}$ 형광체의 광학 및 장잔광특성)

  • Kim, Jeong-Hwan;Kim, Byung-Gyu;Lee, Dong-Kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.174-180
    • /
    • 2002
  • In recent days, the study of a new phosphorescent phosphor has been performed in order to overcome the defect of sulfide phosphor and increase the brightness and long after-glow characteristic of phosphorescent phosphor. Particularly, sulfide phosphor usually used is so chemically unstable that the study of oxide phosphors are processing. $Eu^{2+}$, $Nd^{3+}$ doped Ba-Al-O phosphors sintered at $600{\sim}1500^{\circ}C$ for 2hours had the PL emission spectrum and after-glow over $1200^{\circ}C$. In this system, as the mole concentration of alumina increases, emission bands of phosphors moved from 500nm to 380nm. The optimum concentration of flux was 5wt% and after-glow characteristics of phosphors were found at the host material molar ratio ($BaCO_{3}:Al_{2}O_{3}$), 1:1 and 1:3.

Detection of Irradiated Agricultural Products by Thermoluminescence(TL) (Thermoluminescence(TL)를 이용한 농산물의 방사선 조사유무 확인)

  • Woo, Si-Ho;Yi, Sang-Duk;Yang, Jae-Seung
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.525-530
    • /
    • 2000
  • A study was carried out to establish the detection method of irradiated agricultural products cultivated in Korea by Thermoluminscece(TL). Samples were irradiated using Co-60 gamma rays at various doses(0.05, 0.1, 0.2, 0.3 and 0.5 kGy). After irradiation, separated minerals of the samples measured by TL. TL intensity increased with increasing doses and the irradiated samples were higher than the non-irradiated samples. TL first and second glow curves showed maximum TL temperature point at $176.16{\sim}190.08^{\circ}C$ and $143.84{\sim}146.56^{\circ}C$, respectively. All the irradiated samples can be classified correctly by the shape of the glow curve and the glow curve ratio. Correlation coefficients of ginger, carrot, potato and sweet potato were 0.9968, 0.8522, 0.9612 and 0.9071, respectively, that showed very high correlation between irradiation dose and TL intensity. Therefore, these results suggest that TL measurement is an useful detection method for irradiated agricultural products.

  • PDF

Observation of Several Detection Factors Derived from Thermoluminescence of Mineral Separated from Irradiated Korean Sesame and Perilla Seeds Stored under Different Storage Conditions

  • Oh, Man-Jin;Yi, Sang-Duk;Yang, Jae-Seung
    • Preventive Nutrition and Food Science
    • /
    • v.7 no.2
    • /
    • pp.188-194
    • /
    • 2002
  • This study was carried out to observe changes in several detection factors derived from thermoluminescence (TL) of minerals separated from irradiated Korean perilla and sesame seeds during storage under normal room and darkroom conditions. The TL intensities of the first glow curves increased from 0 to 5 kGy but only slightly increase from 5 to 10 kGy. Maximum TL temperatures of the first glow curves in all irradiated samples were around 20$0^{\circ}C$, ranging from 150 to 25$0^{\circ}C$. Since the control (0 day of storage) glow curve ratios of G3 and G4, calculated from re-irradiated (1 kGy) sample were over 0.5, detection of irradiation was possible. However, because Gl ratios were below 0.1, they were classified as non-irradiated. There was n unique first glow curve shape that could be clearly seen in all irradiated samples, regardless of storage conditions, that was never seen in non-irradiated samples. In all samples, the maximum TL temperatures and shape of the second glow curve was in a lower temperature range than that of the first glow curve. Therefore, detection of irradiated Korean perilla and sesame seeds was possible fur up to 3 months after irradiation, regardless of storage conditions, by examining several TL detection factors; including TL intensity, glow curve ratios maximum TL temperatures, and the shapes of glow curves.

Comparative Analysis of Flame Retardant Performance of Japanese Cypress Plywood Based on the Main Ingredients of Fire Retardant Paint (도료의 주성분에 따른 편백 합판의 방염성능 비교 분석)

  • Soo-Hee Lim;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.1
    • /
    • pp.61-66
    • /
    • 2023
  • The purpose of this study is to compare and analyze the flame retardant performance of Japanese cypress(Chamaecyparis obtusa) plywood, commonly used in indoor decoration, furniture, and tableware, by treating it with three different fire retardants with different primary ingredients. The experiment was conducted in compliance with Article 31, Paragraph 2 of the Enforcement Decree of the Fire Facilities Installation and Management Act and Articles 4 and 7-2 of the Flame Retardant Performance Standards. After flame time, after glow time, char length, and char area were measured. As a result, first, after flame time was measured at 0 seconds regardless of whether the flame retardant treatment was applied. Second, after glow time was relatively long, measuring 22.7 seconds without treatment, which is likely due to the weak fire resistance and high concentration of carbon monoxide generated by the chemical characteristics of the Japanese cypress itself. Third, it was confirmed that the effects of the primary ingredient, phosphorus, in the flame retardant treatment varied depending on the technological development of the manufacturers of the same species of Japanese cypress plywood. In the future, it is expected that the results of this study will provide fundamental data to select flame retardant treatments that show high flame retardant performance according to the botanical characteristics of the wood.

Numerical Analysis of Micro-Discharge in Plasma Display Panel Using 2-Fluid, 2-Dimensional MD equations (2차원, 2유체 MHD 식을 이용한 플라즈마 디스플레이 판넬의 미소 방전 특성 해석)

  • Choi, Kyung-Cheol;Whang, Ki-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.911-914
    • /
    • 1992
  • We have investigated the micro-discharge in plasma display panel using 2 dimensional 2 fluid MHD equations. Plasma display utilizes the physical phenomena of the normal glow or abnormal glow and is considered to be able to provide the largest display area among various flat panel. 2 fluid, 2 dimensional Magneto-Hydro-Dynamic equations are applied to Computational field of 100${\times}$800${\mu}m^2$. Time varing glows and after-glows were investigated for 11 $\mu$sec. We obtained the distribution of the microscopic variables such as the density, temperature, velocity of Ne+Ar0.1% gas plasma. During the first 6$\mu$ sec, glow discharge dued to DC pulse was investigated. Time varing phenomena of after-glow was also investigated during the last 5 $\mu$set. From results, it was found that the driving efficiency of a DC Plasma Display Panel could be improved when the diffusion of ions and electrons are controlled by the pulses applied to the auxiliary anode.

  • PDF

Characteristics of the Maximum Glow Intensity According to the Thermoluminescent Phosphors used in the Absorbed Dose Measurement of the Radiation Therapy (방사선치료 선량 측정에 사용되는 열형광체에 따른 최대 형광 강도 특성)

  • Kang, Suman;Im, Inchul;Park, Cheolwoo;Lee, Mihyeon;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.181-187
    • /
    • 2014
  • The purpose of this study were to analyze the characteristic of the glow curves in order to the glow temperature of the thermoluminescent dosimeters (TLDs) for the absorbed dose measurement of the radiation therapy. In this study, we was used the TLDs of the LiF:Mg${\cdot}$Ti, LiF:Mg${\cdot}$Cu${\cdot}$P, $CaF_2$:Dy, $CaF_2$:Mn (Thermo Fisher Scientific Inc., USA). The source-to-solid dry phantom (RW3 slab, IBA Dosmetry, Germany) surface distance was set at 100 cm, and the exposure dose of 100 MU (monitor unit) was used 6- and 15-MV X-rays, and 6- and 12-MeV electron beams in the reference depth, respectively. After the radiations exposure, we were to analyze the glow curves by using the TL reader (Hashaw 3500, Thermo Fisher Scientific Inc., USA) at the fixed heating rate of $15^{\circ}C/sec$ from $50^{\circ}C$ to $260^{\circ}C$. The glow peaks, the trapping level in the captured electrons and holes combined with the emitted light, were discovered the two or three peak. When the definite increasing the temperature of the TLDs, the maximum glow peak representing the glow temperature was follow as; $LiF:Mg{\cdot}Ti$: $185.5{\pm}1.3^{\circ}C$, $LiF:Mg{\cdot}Ti$: $135.0{\pm}5.1^{\circ}C$, $CaF_2$:Dy: $144.0{\pm}1.6^{\circ}C$, $CaF_2$:Mn: $294.3{\pm}3.8^{\circ}C$, respectively. Because the glow emission probability of the captured electrons depend on the heating temperature after the exposure radiation, TLDs by applying the fixed heating rate, the accuracy of measurement will be able to improve within the absorbed dose measurement of the radiation therapy.