• Title/Summary/Keyword: affine registration

Search Result 31, Processing Time 0.031 seconds

Multimodality Image Registration and Fusion using Feature Extraction (특징 추출을 이용한 다중 영상 정합 및 융합 연구)

  • Woo, Sang-Keun;Kim, Jee-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.2 s.46
    • /
    • pp.123-130
    • /
    • 2007
  • The aim of this study was to propose a fusion and registration method with heterogeneous small animal acquisition system in small animal in-vivo study. After an intravenous injection of $^{18}F$-FDG through tail vain and 60 min delay for uptake, mouse was placed on an acryl plate with fiducial markers that were made for fusion between small animal PET (microPET R4, Concorde Microsystems, Knoxville TN) and Discovery LS CT images. The acquired emission list-mode data was sorted to temporally framed sinograms and reconstructed using FORE rebining and 2D-OSEM algorithms without correction of attenuation and scatter. After PET imaging, CT images were acquired by mean of a clinical PET/CT with high-resolution mode. The microPET and CT images were fusion and co-registered using the fiducial markers and segmented lung region in both data sets to perform a point-based rigid co-registration. This method improves the quantitative accuracy and interpretation of the tracer.

  • PDF

Analysis of Co-registration Performance According to Geometric Processing Level of KOMPSAT-3/3A Reference Image (KOMPSAT-3/3A 기준영상의 기하품질에 따른 상호좌표등록 결과 분석)

  • Yun, Yerin;Kim, Taeheon;Oh, Jaehong;Han, Youkyung
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.2
    • /
    • pp.221-232
    • /
    • 2021
  • This study analyzed co-registration results according to the geometric processing level of reference image, which are Level 1R and Level 1G provided from KOMPSAT-3 and KOMPSAT-3A images. We performed co-registration using each Level 1R and Level 1G image as a reference image, and Level 1R image as a sensed image. For constructing the experimental dataset, seven Level 1R and 1G images of KOMPSAT-3 and KOMPSAT-3A acquired from Daejeon, South Korea, were used. To coarsely align the geometric position of the two images, SURF (Speeded-Up Robust Feature) and PC (Phase Correlation) methods were combined and then repeatedly applied to the overlapping region of the images. Then, we extracted tie-points using the SURF method from coarsely aligned images and performed fine co-registration through affine transformation and piecewise Linear transformation, respectively, constructed with the tie-points. As a result of the experiment, when Level 1G image was used as a reference image, a relatively large number of tie-points were extracted than Level 1R image. Also, in the case where the reference image is Level 1G image, the root mean square error of co-registration was 5 pixels less than the case of Level 1R image on average. We have shown from the experimental results that the co-registration performance can be affected by the geometric processing level related to the initial geometric relationship between the two images. Moreover, we confirmed that the better geometric quality of the reference image achieved the more stable co-registration performance.

A Study on Semi-Automatic Registration for Synthesizing Natural Video and Virtual Objects (합성 컨텐츠 저작을 위한 반자동 정합 기술에 관한 연구)

  • Jeong, Se-Yoon;Kim, Kyu-Heon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.11a
    • /
    • pp.661-664
    • /
    • 2002
  • 실사 영상에 가상 객체를 합성하기 위해서는 실사 영상 촬영 당시의 카메라 정보가 필요하다. 본 논문에서는 이러한 카메라 정보를 구하기 위하여 가상현실 분야에서 사용하고 있는 캘리브레이션 프리 정합 (Calibration-Free Registration) 기술을 기반으로 한 반자동 정합 기술을 제안하였다. 가상 현실은 실시간 응용인데 반하여 본 논문에서 제안하는 반자동 정합 기술은 합성 컨텐츠 저작을 위한 오프라인 응용에 적합한 방법으로 캘리브레이션 프리 정합기술의 합성 결과는 사용자의 입력정보와 밀접한 관계가 있다. 캘리브레이션 프리 정합기술은 두가지 사용자 입력을 필요로 한다. 첫번째 입력은 어파인공간 (Affine space)의 기저 (Basis vector)를 위한 특징점 정보이고, 두번째 입력 정보는 가상객체의 영상 투영점 입력이다. 본 논문에서는 이 두가지 사용자 입력중 기저를 위한 특징점 정보입력을 사용자가 쉽게, 정확한 정보를 입력할 수 있게하기 위하여, 사용자가 특징점을 개략적으로 입력하게 하고, 주변 영역에서 코너점 검출을 수행하여 사용자 입력을 수정하여 받아들리는 방법을 제안하였다. 실험결과 제안한 방법을 사용하여 구한 카메라 정보로 만족할 만한 합성 영상을 얻을 수 있었다.

  • PDF

Development of the Multi-Parametric Mapping Software Based on Functional Maps to Determine the Clinical Target Volumes (임상표적체적 결정을 위한 기능 영상 기반 생물학적 인자 맵핑 소프트웨어 개발)

  • Park, Ji-Yeon;Jung, Won-Gyun;Lee, Jeong-Woo;Lee, Kyoung-Nam;Ahn, Kook-Jin;Hong, Se-Mie;Juh, Ra-Hyeong;Choe, Bo-Young;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.153-164
    • /
    • 2010
  • To determine the clinical target volumes considering vascularity and cellularity of tumors, the software was developed for mapping of the analyzed biological clinical target volumes on anatomical images using regional cerebral blood volume (rCBV) maps and apparent diffusion coefficient (ADC) maps. The program provides the functions for integrated registrations using mutual information, affine transform and non-rigid registration. The registration accuracy is evaluated by the calculation of the overlapped ratio of segmented bone regions and average distance difference of contours between reference and registered images. The performance of the developed software was tested using multimodal images of a patient who has the residual tumor of high grade gliomas. Registration accuracy of about 74% and average 2.3 mm distance difference were calculated by the evaluation method of bone segmentation and contour extraction. The registration accuracy can be improved as higher as 4% by the manual adjustment functions. Advanced MR images are analyzed using color maps for rCBV maps and quantitative calculation based on region of interest (ROI) for ADC maps. Then, multi-parameters on the same voxels are plotted on plane and constitute the multi-functional parametric maps of which x and y axis representing rCBV and ADC values. According to the distributions of functional parameters, tumor regions showing the higher vascularity and cellularity are categorized according to the criteria corresponding malignant gliomas. Determined volumes reflecting pathological and physiological characteristics of tumors are marked on anatomical images. By applying the multi-functional images, errors arising from using one type of image would be reduced and local regions representing higher probability as tumor cells would be determined for radiation treatment plan. Biological tumor characteristics can be expressed using image registration and multi-functional parametric maps in the developed software. The software can be considered to delineate clinical target volumes using advanced MR images with anatomical images.

Automatic Registration Between KOMPSAT-2 and TerraSAR-X Images (KOMPSAT-2 영상과 TerraSAR-X 영상 간 자동기하보정)

  • Han, You-Kyung;Byun, Young-Gi;Chae, Tae-Byeong;Kim, Yong-Il
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.6
    • /
    • pp.667-675
    • /
    • 2011
  • In this paper, we propose an automatic image-to-image registration between high resolution multi-sensor images. To do this, TerraSAR-X image was shifted according to the initial translation differences of the x and y directions between images estimated using Mutual Information method. After that, the Canny edge operator was applied to both images to extract linear features. These features were used to design a cost function that finds matching points based on the similarities of their locations and gradient orientations. For extracting large number of evenly distributed matching points, only one point within each regular grid constructed throughout the image was extracted to the final matching point pair. The model, which combined the piecewise linear function with the global affine transformation, was applied to increase the accuracy of the geometric correction, and the proposed method showed RMSE lower than 5m in all study sites.

A method for ultrasound image edge enhancement by using Probabilistic edge map (초음파 진단영상 대조도 개선을 위한 확률 경계 맵을 이용한 연구)

  • Choi, Woo-hyuk;Park, Won-hwan;Park, Sungyun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.20 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • Ultrasonic imaging is the most widely modality among modern imaging device for medical diagnosis. Nevertheless, medical ultrasound images suffer from speckle noise and low contrast. In this paper, we propose probabilistic edge map for ultrasound image edge enhancement using automatic alien algorithm. The proposed method used applied speckle reduced ultrasound imaging for edge improvement using sequentially acquired ultrasound imaging. To evaluate the performance of method, the similarity between the reference and edge enhanced image was measured by quantity analysis. The experimental results show that the proposed method considerably improves the image quality with region edge enhancement.

Joint Segmentation of Multi-View Images by Region Correspondence (영역 대응을 이용한 다시점 영상 집합의 통합 영역화)

  • Lee, Soo-Chahn;Kwon, Dong-Jin;Yun, Il-Dong;Lee, Sang-Uk
    • Journal of Broadcast Engineering
    • /
    • v.13 no.5
    • /
    • pp.685-695
    • /
    • 2008
  • This paper presents a method to segment the object of interest from a set of multi-view images with minimal user interaction. Specifically, after the user segments an initial image, we first estimate the transformations between foreground and background of the segmented image and the neighboring image, respectively. From these transformations, we obtain regions in the neighboring image that respectively correspond to the foreground and the background of the segmented image. We are then able to segment the neighboring image based on these regions, and iterate this process to segment the whole image set. Transformation of foregrounds are estimated by feature-based registration with free-form deformation, while transformation of backgrounds are estimated by homography constrained to affine transformation. Here, both are based on correspondence point pairs. Segmentation is done by estimating pixel color distributions and defining a shape prior based on the obtained foreground and background regions and applying them to a Markov random field (MRF) energy minimization framework for image segmentation. Experimental results demonstrate the effectiveness of the proposed method.

Enhancement of Spatial Resolution to Local Area for High Resolution Satellite Imagery (고해상도 위성영상을 위한 국소영역 공간해상도 향상 기법)

  • Kang, Ji-Yun;Kim, Ihn-Cheol;Kim, Jea-Hee;Park, Jong Won
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.4
    • /
    • pp.137-143
    • /
    • 2013
  • The high resolution satellite images are used in many fields such as weather observation, remote sensing, military facilities monitoring, cultural properties protection etc. Although satellite images are obtained in same satellite imaging system, the satellite images are degraded depending on the condition of hardware(optical device, satellite operation altitude, image sensor, etc.). Due to the fact that changing the hardware of satellite imaging system is impossible for resolution enhancement of these degraded satellite after launching a satellite, therefore the method of resolution enhancement with satellite images is necessary. In this paper the resolution is enhances by using a Super Resolution(SR) algorithm. The SR algorithm is an algorithm to enhance the resolution of an image by uniting many low resolution images, so an output image has higher resolution than using other interpolation methods. But It is difficult to obtain many images of the same area. Therefore, to solve this problem, we applied SR after by applying the affine and projection transform. As a results, we found that the images applied SR after affine and projection transform have higher resolution than the images only applied SR.

Comparison Among Sensor Modeling Methods in High-Resolution Satellite Imagery (고해상도 위성영상의 센서모형과 방법 비교)

  • Kim, Eui Myoung;Lee, Suk Kun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6D
    • /
    • pp.1025-1032
    • /
    • 2006
  • Sensor modeling of high-resolution satellites is a prerequisite procedure for mapping and GIS applications. Sensor models, describing the geometric relationship between scene and object, are divided into two main categories, which are rigorous and approximate sensor models. A rigorous model is based on the actual geometry of the image formation process, involving internal and external characteristics of the implemented sensor. However, approximate models require neither a comprehensive understanding of imaging geometry nor the internal and external characteristics of the imaging sensor, which has gathered a great interest within photogrammetric communities. This paper described a comparison between rigorous and various approximate sensor models that have been used to determine three-dimensional positions, and proposed the appropriate sensor model in terms of the satellite imagery usage. Through the case study of using IKONOS satellite scenes, rigorous and approximate sensor models have been compared and evaluated for the positional accuracy in terms of acquirable number of ground controls. Bias compensated RFM(Rational Function Model) turned out to be the best among compared approximate sensor models, both modified parallel projection and parallel-perspective model were able to be modelled with a small number of controls. Also affine transformation, one of the approximate sensor models, can be used to determine the planimetric position of high-resolution satellites and perform image registration between scenes.

Knee Cartilage Defect Assessment using Cartilage Thickness Atlas (무릎 연골 두께 아틀라스를 통한 손상 평가 기법)

  • Lee, Yong-Woo;Bui, Toan Duc;Ahn, Chunsoo;Shin, Jitae
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.2
    • /
    • pp.43-47
    • /
    • 2015
  • Osteoarthritis is the most common chronic joint disease in the world. With its progression, cartilage thickness tends to diminish, which causes severe pain to human being. One way to examine the stage of osteoarthritis is to measure the cartilage thickness. When it comes to inter-subject study, however, it is not easy task to compare cartilage thickness since every human being has different cartilage structure. In this paper, we propose a method to assess cartilage defect using MRI inter-subject thickness comparison. First, we used manual segmentation method to build accurate atlas images and each segmented image was labeled as articular surface and bone-cartilage interface in order to measure the thickness. Secondly, each point in the bone-cartilage interface was assigned the measured thickness so that the thickness does not change after registration. We used affine transformation and SyGN to get deformation fields which were then applied to thickness images to have cartilage thickness atlas. In this way, it is possible to investigate pixel-by-pixel thickness comparison. Lastly, the atlas images were made according to their osteoarthritis grade which indicates the degree of its progression. The result atlas images were compared using the analysis of variance in order to verify the validity of our method. The result shows that a significant difference is existed among them with p < 0.001.