• 제목/요약/키워드: aerodynamic countermeasure

검색결과 5건 처리시간 0.019초

Aerodynamic performance evaluation of different cable-stayed bridges with composite decks

  • Zhou, Rui;Ge, Yaojun;Yang, Yongxin;Du, Yanliang;Zhang, Lihai
    • Steel and Composite Structures
    • /
    • 제34권5호
    • /
    • pp.699-713
    • /
    • 2020
  • The aerodynamic performance of long-span cable-stayed bridges is much dependent on its geometrical configuration and countermeasure strategies. In present study, the aerodynamic performance of three composite cable-stayed bridges with different tower configurations and passive aerodynamic countermeasure strategies is systematically investigated by conducting a series of wind tunnel tests in conjunction with theoretical analysis. The structural characteristics of three composite bridges were firstly introduced, and then their stationary aerodynamic performance and wind-vibration performance (i.e., flutter performance, VIV performance and buffeting responses) were analyzed, respectively. The results show that the bridge with three symmetric towers (i.e., Bridge I) has the lowest natural frequencies among the three bridges, while the bridge with two symmetric towers (i.e., Bridge II) has the highest natural frequencies. Furthermore, the Bridge II has better stationary aerodynamic performance compared to two other bridges due to its relatively large drag force and lift moment coefficients, and the improvement in stationary aerodynamic performance resulting from the application of different countermeasures is limited. In contrast, it demonstrates that the application of both downward vertical central stabilizers (UDVCS) and horizontal guide plates (HGP) could potentially significantly improve the flutter and vortex-induced vibration (VIV) performance of the bridge with two asymmetric towers (i.e., Bridge III), while the combination of vertical interquartile stabilizers (VIS) and airflow-depressing boards (ADB) has the capacity of improving the VIV performance of Bridge II.

Control effect and mechanism investigation on the horizontal flow-isolating plate for PI shaped bridge decks' VIV stability

  • Li, Ke;Qian, Guowei;Ge, Yaojun;Zhao, Lin;Di, Jin
    • Wind and Structures
    • /
    • 제28권2호
    • /
    • pp.99-110
    • /
    • 2019
  • Vortex-Induced-Vibration (VIV) is one kind of the wind-induced vibrations, which may occur in the construction and operation period of bridges. This phenomenon can bring negative effects to the traffic safety or can cause bridge fatigue damage and should be eliminated or controlled within safe amplitudes.In the current VIV studies, one available mitigation countermeasure, the horizontal flow-isolating plate, shows satisfactory performance particularly in PI shaped bridge deck type. Details of the wind tunnel test are firstly presented to give an overall description of this appendage and its control effect. Then, the computational-fluid-dynamics(CFD) method is introduced to investigate the control mechanism, using two-dimensional Large-Eddy-Simulation to reproduce the VIV process. The Reynolds number of the cases involved in this paper ranges from $1{\times}10^5$ to $3{\times}10^5$, using the width of bridge deck as reference length. A field-filter technique and detailed analysis on wall pressure are used to give an intuitive demonstration of the changes brought by the horizontal flow-isolating plate. Results show that this aerodynamic appendage is equally effective in suppressing vertical and torsional VIV, indicating inspiring application prospect in similar PI shaped bridge decks.

Investigation on vortex-induced vibration of a suspension bridge using section and full aeroelastic wind tunnel tests

  • Sun, Yanguo;Li, Mingshui;Liao, Haili
    • Wind and Structures
    • /
    • 제17권6호
    • /
    • pp.565-587
    • /
    • 2013
  • Obvious vortex induced vibration (VIV) was observed during section model wind tunnel tests for a single main cable suspension bridge. An optimized section configuration was found for mitigating excessive amplitude of vibration which is much larger than the one prescribed by Chinese code. In order to verify the maximum amplitude of VIV for optimized girder, a full bridge aeroelastic model wind tunnel test was carried out. The differences between section and full aeroelastic model testing results were discussed. The maximum amplitude derived from section model tests was first interpreted into prototype with a linear VIV approach by considering partial or imperfect correlation of vortex-induced aerodynamic force along span based on Scanlan's semi-empirical linear model. A good consistency between section model and full bridge model was found only by considering the correlation of vortex-induced force along span.

고속(KTX) 및 기존 철도차량의 열차풍 현상 비교 분석 (The Comparative Analysis of Slipstream Phenomena by High-Speed and Traditional Train)

  • 김동현;장용준
    • 대한기계학회논문집B
    • /
    • 제31권2호
    • /
    • pp.173-180
    • /
    • 2007
  • A series of field tests were performed to develop aerodynamic characteristic evaluation method and countermeasure technology in conventional and high-speed railway. The strength of rolling stock-induced wind which affect the people and substructure in platform and nearby track were investigated. The slipstream of passing trains was measured by hot-wire array system. The speed of trains was 110 - 125km/h for conventional ones and 300km/h for high-speed ones. The streamlined shape trains cause about 50% smaller-scale slipstream compared to the non-streamlined ones.

횡방향 새그를 가진 자정식 현수교의 공탄성 거동(II) - 주탑의 거동을 중심으로 - (Aeroelastic Behaviors of Self-anchored Suspension Bridge with Lateral Sag of Main Cable(II) - Focused on the Behavior of Tower -)

  • 권순덕;장승필
    • 한국강구조학회 논문집
    • /
    • 제9권2호통권31호
    • /
    • pp.269-275
    • /
    • 1997
  • 본 연구에서는 자정식 현수교 주탑의 내풍 안정성을 보기 위하여 주탑 모형 실험과 전교 모형 실험을 수행하고 그 결과를 분석하였다. 경사진 병렬 탑주를 가진 주탑의 경우에는 다양한 주파수대의 웨이크가 존재하므로 넓은 풍속대에서 진동이 발생한다는 사실을 확인하였다. 자정식 현수교의 경우에는 주형의 교축방향 지지조건에 따라 주탑 진동 모드가 매우 민감하게 변화하였다. 본 연구 대상 주탑은 면외 휨 모드와 비틈 모드의 고유진동수가 매우 근접해 있어서 넓은 범위의 풍속에서 연성진동이 발생하였다 주탑 진동을 완화하기 위한 공기역학적 수단으로 모서리 자르기를 시도하였는데, 탑주의 폭과 잘린 모서리의 비가 1/10일 때가 가장 효과적이었다.

  • PDF