• Title/Summary/Keyword: aerodynamic

Search Result 3,108, Processing Time 0.028 seconds

Influence of Precooling Cooling Air on the Performance of a Gas Turbine Combined Cycle (냉각공기의 예냉각이 가스터빈 복합발전 성능에 미치는 영향)

  • Kwon, Ik-Hwan;Kang, Do-Won;Kang, Soo-Young;Kim, Tong-Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.2
    • /
    • pp.171-179
    • /
    • 2012
  • Cooling of hot sections, especially the turbine nozzle and rotor blades, has a significant impact on gas turbine performance. In this study, the influence of precooling of the cooling air on the performance of gas turbines and their combined cycle plants was investigated. A state-of-the-art F-class gas turbine was selected, and its design performance was deliberately simulated using detailed component models including turbine blade cooling. Off-design analysis was used to simulate changes in the operating conditions and performance of the gas turbines due to precooling of the cooling air. Thermodynamic and aerodynamic models were used to simulate the performance of the cooled nozzle and rotor blade. In the combined cycle plant, the heat rejected from the cooling air was recovered at the bottoming steam cycle to optimize the overall plant performance. With a 200K decrease of all cooling air stream, an almost 1.78% power upgrade due to increase in main gas flow and a 0.70 percent point efficiency decrease due to the fuel flow increase to maintain design turbine inlet temperature were predicted.

Benefits of Palliative Office-Based Hyaluronic Acid Injection Laryngoplasty in Cancer-Related Unilateral Vocal Cord Paralysis Patients (악성 종양 관련 일측성 성대 마비 환자에서 고식적 Hyaluronic Acid 성대 주입 성형술의 유용성)

  • Kim, Go-Woon;Park, Young-Hak;Joo, Young-Hoon;Kim, Sang-Yeon;Shim, Mi-Ran;Hwang, Yeon-Sin;Sun, Dong-Il
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.29 no.1
    • /
    • pp.30-36
    • /
    • 2018
  • Background and Objectives : The effect of palliative injection laryngoplasty in cancer-related unilateral vocal cord paralysis patients on voice and swallowing function is uncertain and there are few previous studies of its suitability, benefits as a palliative treatment option. The purpose of this study is to confirm the objective results of voice and swallowing function after palliative office-based hyaluronic acid injection laryngoplasty in cancer-related unilateral vocal cord paralysis patients. Materials and Method : 36 patients who had unilateral vocal cord paralysis from non-thyroidal, extralaryngeal neoplasms were included in this study. To evaluate the clinical outcome, we analyzed perceptual GRBAS grading, acoustic analysis, aerodynamic study, Electroglottography (EGG), Voice Handicap Index (VHI-30) about voice function and disability rating scale (DRS), gastric tube dependency, aspiration pneumonia about swallowing function and 36-Item Short Form Survey version 2 (SF-36v2) about quality of life. Results : In GRBAS scale, G (p<0.001), R (p=0.004), B (p=0.001), A (p=0.011), and S (p=0.007) showed significant improvement. Jitter, shimmer, speaking fundamental frequency, maximal phonation time, VHI-30, DRS score, gastric tube dependency, aspiration pneumonia, and SF-36v2 were significantly improved after injection (p=0.016, p=0.011, p=0.045, p=0.005, p<0.001, p<0.001 p=0.003, p<0.001, and p<0.001 respectively). Conclusion : From this study we concluded office-based hyaluronic acid injection can be used as a useful palliative treatment option in cancer-related ill patients with unilateral vocal cord paralysis. Palliative hyaluronic acid injection laryngoplasty avoids the need for tube feeding, thus reducing the risk of aspiration pneumonia. These outcomes are accompanied by significant improvement in voice quality.

The Correlation between The Size and Location of Vocal Polyp and Voice Quality, Before and After Laryngeal Microsurgery (후두미세수술 전후 성대 용종의 크기 및 위치가 음성의 질의 변화에 미치는 영향)

  • Han, Won Gue;Kim, Min-Su;Oh, Kyung Ho;Woo, Jeung Soo;Jung, Kwang Yoon;Kwon, Soon Young
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.27 no.2
    • /
    • pp.102-107
    • /
    • 2016
  • Background and Objectives : Vocal polyps are caused by inflammation induced by stress or irritation. Many patients with vocal polyps complain voice discomfort. For vocal polyps, surgery such as laryngeal microsurgery has been the mainstay of management. We analyzed the clinical features of vocal polyps, and how the size and location of vocal polyps affect the outcomes of surgery. Methods : We retrospectively reviewed 42 patients from March 2014 to December 2015, who were diagnosed as unilateral single vocal polyp. When we operated on a vocal polyp with laryngeal microscopy, we measured their size and location. The quality of voice was evaluated by GRABS scale, jitter, shimmer, NHR (noise to harmonic ratio), MPT (maximum phonation time), and VHI (voice handicap index) before operation and 4 weeks after operation. Results : When we divided the patients into large-sized vocal polyp group (the longest length >3 mm) and small-sized vocal polyp group (the longest length ${\leq}3mm$), all parameter differences tend to be greater at large sized vocal polyp. However, these differences were not statistically significant (p>0.05). When we divided into two groups depending on the volume of vocal polyp, no distinct tendency was found. When we compared the location (anterior, mid and posterior) of vocal polyp with the improvement of voice quality, more change was found at mid portion vocal polyp, except the difference of VHI. However, these differences were also not statistically significant (p>0.05). Conclusion : All parameter differences tend to be greater at large vocal polyp and polyp of the mid location.

  • PDF

Estimation of Air-Sea Heat Exchange Using BUOY Data at the Yellow Sea, Korea (부이 관측자료를 이용한 서해 해역의 해양-대기 열교환량 산출)

  • kang, Yune-Jeung;Hwang, Seung-On;Kim, Tae-Hee;Nam, Jae-Cheol
    • Journal of the Korean earth science society
    • /
    • v.22 no.1
    • /
    • pp.40-46
    • /
    • 2001
  • Heat exchange between the atmosphere and sea is produced using the data from two 3m discus buoy installed by KMA in 1996. The meteorological and oceanic characteristics at the Dukjukdo and Chilbaldo buoy for the period 1996 ${\sim}$ 2000 are discussed. Daily averaged sensible heat and latent heat flux at each site are estimated from bulk aerodynamic method using given data and analyzed. Quantitative analyses show SST indicates 1-year cycle like air temperature but has 1 month lag. Sea level pressure is lowest in July, humidity is higher from May to August, and wind speed has averaged value of 5 m/s and higher in autumn and winter. Sensible heat flux analyses present that strong heat loss from the sea occurs in autumn and winter and weak heat loss from atmosphere appears in spring and summer, and net sensible heat loss from the sea is found throughout the year. The ocean significantly releases latent heat into atmosphere from August to May but get a little latent heat from atmosphere in other months. Net latent heat loss from the sea is larger than net sensible heat loss except in January and February. Comparison with two sites suggests that the magnitude of heat flux and their fluctuation are generally stronger at Dukjukdo than at Chilbaldo. In case study, both sensible and latent heat flux is a little more at Chilbaldo in March 1998, but substantially stronger at Dukjukdo in November 1996.

  • PDF

Cumulative Distributions and Flow Structure of Two-Passage Shear Coaxial Injector with Various Gas Injection Ratio (2중 유로형 전단 동축 분사기의 기체 분사율에 따른 유동 및 입도분포)

  • Lee, Inchul;Kim, Dohun;Koo, Jaye
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.7
    • /
    • pp.675-682
    • /
    • 2013
  • To verify the effect of inner- and outer-stage gas jets, a shear coaxial injector was designed to analyze the axial velocity profile and breakup phenomenon with an increase in the measurement distance. When the measurement position was increased to Z/d=100, the axial flow showed a fully developed shape due to the momentum transfer, aerodynamic drag effect, and viscous mixing. An inner gas injection, which induces a higher momentum flux ratio near the nozzle, produces the greater shear force on atomization than an outer gas injection. Inner- and Outer-stage gas injection do not affect the mixing between the inner and outer gas flow below Z/d=5. The experiment results showed that the main effect of liquid jet breakup was governed by the gas jet of an inner stage. As the nozzle exit of the outer-stage was located far from the liquid column, shear force and turbulence breaking up of the liquid jets do not fully affect the liquid column. In the case of an inner-stage gas injection momentum flux ratio within 0.84, with the increase in the outer gas momentum flux ratio, the SMD decreases. However, at an inner-stage gas jet momentum flux ratio over 1.38, the SMD shows the similar distribution.

Effect of Medium and Small Scale Shipyard Operations on Environmental Pollutions Related with Civil Appeal (중.소규모 조선소 조업이 주요 민원 유발성 환경오염에 미치는 영향)

  • Chung, Jae-Woo;Lee, Myoung-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.10
    • /
    • pp.1006-1012
    • /
    • 2008
  • The effect of small and medium scale shipyard operations on environmental pollutions related with civil appeal of nearby residential areas was estimated. PM-10(particles with an aerodynamic diameter less than or equal to 10 $\mu$m) concentrations were higher, as the sampling sites were nearer from shipyards. PM-10 concentrations of sampling sites closer to shipbuilding companies were higher during the normal operation periods than on vacation at which only small works were done. The larger amount of dry deposition was observed as the sampling sites were closer to shipyards. The odor intensity was highly influenced by ambient temperature. Almost all odor intensities measured by air dilution sensory test went over the emission standard in summer. Odor properties measured by instrumental analysis were observed to exceed the emission standard enforced to the shipyards. Odor compounds such as ammonia, sulfur compounds and trimethylamine went over the standard. Concentrations of styrene and aldehydes were lower than the olfactory threshold. All equivalent sound levels measured at daytime except the value of SP-3 pont were in excess of the environmental standard. Almost all sound levels at nighttime in all measuring sites were higher than the environmental standard. The results of this study shows counterplans need to be established for reducing the civil appeal related pollutions in the research areas.

Structural Design and Experimental Investigation of A Medium Scale Composite Wind Turbine Blade Considering Fatigue Life (피로 수명을 고려한 중형 복합재 풍력터빈 블레이드의 구조설계 및 실험 평가)

  • Gong, Chang Deok;Bang, Jo Hyeok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.3
    • /
    • pp.23-30
    • /
    • 2003
  • In this study, the various load cases by specified by the IEC61400-1 international specification and GL Regulations for the wind energy conversion system were considered, and a specific composite structure configuration which can effectively endure various loads was proposed. In order to evaluate the structure, the structural analysis for the composite wind turbine blade was performed using the finite element method(FEM). In the structural design, the acceptable configuration of blade structure was determined through the parametric studies, and the most dominant design parameters were confirmed. In the stress analysis using the FEM, it was confirmed that the blade structure was safe and stable for all the considerd load cases. Moreover the safety of the blade root joint with insert bolts, newly devised in this study, was checked against the design loads and also the fatigue loads. The fatigue life for operating more than 20 years was estimated by using the well-known S-N linear damage rule, the load spectrum and Spera's empirical equations. The full-scale static test was performed under the simulated aerodynamic loads. from the experimental results, it was found that the designed blade had the structural integrity. Furthermore the measured results were agreed with the analytical results such as deflections, strains, the mass and the radial center of gravity. The studied blade was successfully certified by an international institute, GL, of Germany.

Voice Quality in Patients with Asthma (천식환자에서의 음성의 질)

  • Han, Myung-Woul;Kim, Seong-Tae;Choi, Seung-Ho;Kim, Sang-Yoon;Nam, Soon-Yuhl
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.20 no.1
    • /
    • pp.63-67
    • /
    • 2009
  • Background and Objectives: In patients with asthma, increased obstruction and resistance of airway result in impairment in the generation of voice. Allergy and nasal polyposis, which are frequently observed in patients with asthma, are other factors that affect the vocal performance. Bronchodilators and steroids are commonly used in the treatment of asthma, and these agents also have been reported to be associated with voice changes. The aim of this study is to evaluate the voice quality in patients with mild to-moderate asthma by subjective and objective methods. Materials and Methods: A total of 36 patients with asthma established in the Department of Respiratory Medicine were included in this study. 23 were women and 13 were men, with a mean age of 51.7 years. The average duration of asthma was 77.0 months. All patients had mild-to moderate asthma. Acoustic and aerodynamic analyses were performed and the movements of the vocal cords were examined by videolaryngostroboscopy (VLS). Voice Handicap Index (VHI) and GRABS scales were used for subjective evaluations. Results: 50% of patients suffered from dysphonia and FO was 119.3${\pm}$23.7 Hz in male and 198.2${\pm}$18.4 Hz in female patients. There were no significant differences in average shimmer and NHR between females (4.90${\pm}$2.95% ; 0.1O${\pm}$0.04 dB) and males (4.64${\pm}$2.45% ; 0.20${\pm}$0.15 dB). However, the value of jitter was greater for females (2.60${\pm}$1.92%) than for males (1.21${\pm}$0.84%). The VHI score was above the normal limit in 35%, and VLS findings were shown diverse abnormality in 89% asthmatics from mucosal change to hyperfunction of supragottis and contact granuloma. But duration of illness and steroid dose did not correlate with these findings. Conclusion: Subjective and objective abnormality was shown in more than 50% of asthmatic patients. We suggest that persons who suffer from asthma should be examined for possible voice disorders by laryngologist. Additionally, appropriate medical care and voice therapy should be provided for those who have voice disorders associated with asthma.

  • PDF

Analysis on Ventilation Efficiency of Standard Duck House using Computational Fluid Dynamics (전산유체역학을 이용한 표준 오리사 설계안에 대한 환기효율성 분석)

  • Yeo, Uk-Hyeon;Jo, Ye-Seul;Kwon, Kyeong-Seok;Ha, Tae-Hwan;Park, Se-Jun;Kim, Rack-Woo;Lee, Sang-Yeon;Lee, Seung-No;Lee, In-Bok;Seo, Il-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.5
    • /
    • pp.51-60
    • /
    • 2015
  • In Korea, 69.4 % of duck farms had utilized conventional plastic greenhouses. In this facilities, there are difficulties in controlling indoor environments for raising duck. High rearing density in duct farms also made the environmental control difficult resulting in getting more stressed making their immune system weaker. Therefore, a facility is needed to having structurally enough solidity and high efficiency on the environmental control. So, new design plans of duck house have recently been conducted by National Institute of Animal Science in Korea. As a study in advance to establish standard, computational fluid dynamics (CFD) was used to estimate the aerodynamic problems according to the designs by means of overall and regional ventilation efficiencies quantitatively and qualitatively. Tracer gas decay (TGD) method was used to calculate ventilation rate according to the structural characteristics of duck houses including installation of indoor circulation fan. The results showed that natural ventilation rate was averagely 164 % higher than typically designed ventilation rate, 1 AER ($min^{-1}$). Meanwhile, mechanically ventilated duck houses made 81.2 % of summer ventilation rate requirement. Therefore, it is urgent to develop a new duck house considering more structural safety as well as higher efficiency of environmental control.

Urbanization Effects on Reference Evapotranspiration (도시화에 따른 수문기후변화 II (도시화가 기준 증발산량에 미치는 영향))

  • Rim, Chang-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.7
    • /
    • pp.571-583
    • /
    • 2007
  • The effects of climatic changes owing to urbanization, geographical and topographical conditions on Penman-Monteith reference evapotranspiration, and energy and aerodynamic terms of Penman-Monteith reference evapotranspiration have been studied. In this study, 56 climatological stations including the Seoul metropolis in South Korea have been selected, and the area of study site was set at $314\;km^2$. The climatological station is centrally located In the study area with a 10 km radius. The geographical and topographical characteristics of these sites were examined using GIS analysis. Land use status of the study area was also examined to estimate the extent of urbanization. The study results indicated that the variation of reference evapotranspiration rate is closely related to urbanization in most climatological stations. The level of change in reference evapotranspiration was higher in areas with higher urbanization rates. The change in reference evapotranspiration appears to be caused by temperature rises following heat island phenomena due to urbanization, and by the decrease in humidity, wind speed and sunshine duration due to the Increase in residential areas in urban districts. Especially, the humidity decrease causes a significant decrease in evapotranspiration rate. The study results showed that climatic change due to urbanization and proximity to the coast had the greatest effect on reference evapotranspiration.