• Title/Summary/Keyword: aeration pond

Search Result 6, Processing Time 0.018 seconds

Composting and trickling filter for treatment of olive mill waste

  • Li, Xinhua;Lin, Ching-Chieh;Sweeney, Daniel;Earl, Jessica;Hong, Andy
    • Advances in environmental research
    • /
    • v.2 no.2
    • /
    • pp.131-141
    • /
    • 2013
  • Agricultural practice and improper waste disposal in developing regions have resulted in environmental degradation in land and waters, for which low-cost, proven solutions are needed. We demonstrate in the laboratory the applications of composting and trickling filter techniques to treat olive mill wastes that can be implemented in the West Bank and other regions of the world. To a pomace waste sample from a California mill, we amended with saw dust (wood carbon source) and baking soda ($NaHCO_3$ alkalinity) at weight ratios of waste/wood/$NaHCO_3$ at 70:27:1 and composted it for periods of 11 and 48 days; the compost was used as an additive to potting soil for transplanting. The pomace sample was also blended into slurry and introduced to a water-circulating pond and trickling filter system (P/TF) to examine any inhibitive effect of the pomace on biological removal of the organic waste. The results showed the compost-amended potting soil supported plant growth without noticeable stress over 34 days and the P/TF system removed BOD and COD by >90% from the waste liquid within 2 days, with a first-order rate constant of 1.9 $d^{-1}$ in the pond. An onsite treatment design is proposed that promises implementation for agricultural waste disposal in developing regions.

Analyses of the Environmental Characteristics of Ponds in Golf Courses for Ecological Management (골프장 연못의 생태적 관리를 위한 환경특성 분석)

  • Ahn Deug-Soo;Kim Chang-Hwan
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.6 s.113
    • /
    • pp.51-77
    • /
    • 2006
  • Pond management is a critical part of overall golf course management, both during growth and maintenance modes of turf care. This study investigated 48 ponds in nine 18- or 27-hole golf courses to analyze the environmental characteristics of ponds. The research process had three phases: (1) inventory and analysis of grading plans and drainage plans, (2) field verification and interviews with greenskeepers, and (3) analyses of water quality and statistics. All data were collected from May to August in 2004. The results of this study can be summarized as follows: 1. It is desirable to site a golf course in a small watershed with high watershed eccentricity to control storm water runoff efficiently and to minimize soil erosion during construction. 2. The siting and size of a pond should be determined through a land-use analysis of the watershed for the purpose of ecological management. The bigger the forest-to-golf course ratio, the better the water quality will be. 3. The size and capacity of each individual ponds varied and there were many somewhat longish rather than round ponds. 4. There were many differences among golf courses in naturalness of the ponds, and the correlation between naturalness and area of aquatic plants was very high. 5. Analyses of pond water quality indicated that the degrees of Dissolved Oxygen, Chemical Oxygen Demanded and Suspended Solids were relatively low values but Total Phosphorus and Total Nitrogen were too high. Therefore a systematic approach is needed to solve e problem. Pesticide residues were not detected in all ponds. 6. Water depth and area of hydrophyte should be considered when designing an ecological pond. 7. All ponds used storm water as a main source of water supply and added underground water. Aquatic plants and physical methods such as water aeration and spray fountains were the main choices for maintaining a healthy aquatic environment.

Purification Technology in Closed Water like a Reservoir and Pond using Oxygen Solubilized Device and Standardized Microorganism Culture System (산소용해수와 미생물제재를 이용한 호소 및 폐쇄수역의 정화기술)

  • Seo, Seong-nyeo;Kim, Young-taek;Park, Chul-hwi
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.118-124
    • /
    • 2005
  • The oxygen solubilized device(O.S.D) and standardized microorganism culture system is more efficient than physical and chemical purification techniques in closed water. This study was to determine how the O.S.D and standardized culture system is efficient in purification capacity in closed water based on the lab scale and pilot plant. In the batch test, inducing the quantitative results from pilot plant operation condition, removal efficiency of COD and TN were about 48.3% and 35% respectively, while SS and chlorophyll-a were 94.9% and 68.7%. The pilot plant results showed that suspended solid(SS) and chlorophyll-a removal efficiency were 60% and 59% respectively, due to coagulation characteristics by standardized culture. Total nitrogen(TN) and total phosphorus(TP)showed good effect for the purification of target pond water quality from field data. Additionally, released velocity was determined in control condition of $5.31mgPO{_4}^{3-}{\cdot}m^{-2}{\cdot}day^{-1}$ and $2486.8mgCOD{\cdot}m^{-2}{\cdot}day^{-1}$. Otherwise, phosphate and COD reflux in the aeration and microorganism condition was showed $-9.95mgPO{_4}^{3-}{\cdot}m^{-2}{\cdot}day^{-1}$ and $-397.88mgCOD{\cdot}m^{-2}{\cdot}day^{-1}$. This technology is the most effective not only removal of SS and chlorophyll-a but also control of phosphate and COD release which is very important phenomena in evaluating water quality in closed water like a reservoir and pond.

Oxygen Mass Balance Analysis in an Intermittently Aerated Wetland Receiving Stormwater from Livestock Farms (축산유역 강우유출수 처리를 위한 간헐 포기식 인공습지에서 산소수지분석)

  • Guerra, Heidi B.;Park, Kisoo;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.488-498
    • /
    • 2016
  • In order to assess the role of aeration in stormwater wetlands, oxygen supply and consumption in a wetland treating runoff from livestock farms were estimated and analyzed. Furthermore, oxygen mass balance was conducted during day time and night time. Internal production by algal photosynthesis dominated the oxygen production particularly in the shallow marsh due to the large amount of algae. Consequently, algal respiration was also the major oxygen depletion element with nitrification and biodegradation estimated as 5.35% and 6.43% of the total oxygen consumption. This excessive portion of oxygen consumption by algae was associated to the highly turbid water caused by the resuspension of sediment particles in the aeration pond, which also affected the subsequent wetland. Moreover, an abundance of oxygen was estimated during the day indicating that oxygen produced by algal activity is sufficient to meet the oxygen demand in the wetland. Thus, supplemental aeration was deemed not necessary at daytime. In contrast, oxygen was greatly depleted at night when algal photosynthesis stopped which induced denitrification. Therefore, it was suggested that supplemental aeration may be operated continuously instead of intermittently to avoid oxygen deficit in the wetland at night or it may be stopped entirely to further enhance denitrification.

A Study on Kinetics of Oxygen in Small Size Pond using Oxygen Solubilization Device System (산소 용해수 발생 장치를 이용한 소형 연못의 산소 거동 연구)

  • Kim, Young-Taek;Bae, Yoon-Sun;Roh, Eun-Kyung;Park, Chul-Hwi
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.475-481
    • /
    • 2006
  • The major problem in closing water like lakes and ponds in Korea is that because they are exposed to surrounding, so easily polluted. The pollution in closing water can be caused by not only artificial factor like sewage but also natural factor like elution from sediment. For insurance of safe and satisfied water source, lots of studies and projects are now going on. In this study, we examined the behavior and effect of microbubble ($3{\sim}10{\mu}m$) produced by device called O.S.D (Oxygen Solubillization Device) in small size pond. The value of oxygen transfer coefficient ($K_La$) was 0.68/min independently of air flow rate, 6.5 times higher than commercial aeration stone and the variation of nitrogen concentration was $0.008NO_3/O_2$, DO concentration was potentially saturated for 24 hr. From the results of pilot plant, SOD of experiment (O.S.D) and control were $12.18gO_2{\cdot}m^{-2}{\cdot}d^{-1}$ and $47.95gO_2{\cdot}m^{-2}{\cdot}d^{-1}$ respectively. In conclusion, because O.S.D has extraordinary physico-chemical characteristics, it can contribute to improvement of both the waterbody and the sediment environment.

Analytical examples of volatile amines in ambient airs (공기 중 저급아민류의 분석과 측정 사례)

  • Yu, Mee-Seon;Yang, Sung-Bong
    • Analytical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.216-223
    • /
    • 2005
  • In this study, several kinds of volatile amines in ambiant air were collected and their concentrations were expected from the calibration curves prepared by standard solutions of 7 amines by the official measuring method prescribed in Japanese Offensive Odor Law. The obtained calibration curves showed a good linearity and the detection limit of trimethyl amine was found to be about 0.033 ppb (0.040 ng) in case of 50 liters air. It means that trimethyl amine could be detected with the concentration of lower than its permitting level at the border line of companies. As typical examples of measuring amines in air, results of investigation of two sewage works and one rendering plant around the capital area indicated that 4 kinds of amines, i.e. methyl amine, dimethyl amine, trimethyl amine and isopropyl amine were detectable and concentrations of trimethyl amine at the primary sedimentation pond and sludge dewatering building of the sewage plant A showed 9.07 ppb and 7.79 ppb respectively, being over the concentration of odor strength 2.5, And the aeration tank, excrement input facility and indoor of maintenance room of excrement process building in the sewage plant B showed 70.0 ppb of dimethyl amine and 2.44 ppb of trimethyl amine.