• Title/Summary/Keyword: advanced control room

Search Result 124, Processing Time 0.024 seconds

A Study on the Emission of Hazardous Volatile Compounds in Wood and Steel Furniture (목재 및 철재가구중의 유해물질 방출에 관한 연구)

  • Kim, Sun-Tae;Park, Kyung-Su;Kim, Byoung-Eog;Woo, Soon-Hyung
    • Analytical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.194-201
    • /
    • 1998
  • The formaldehyde vapor produced from wood and steel furniture was absorbed in distilled water and derivatized with acetylacetone and determined by UV-visible spectrophotometry. Variation in HCHO emission with time was monitored at room temperature. The emission of volatile compounds from wood, wood-based and steel-based materials was investigated in a 50 mL glass vial. The concentration of the gases emitted in a glass vial was determined by ion-trap GC-MS.

  • PDF

Development of engine room monitoring system complied with IEC 61162-3 international standards for ship's network (IEC 61162-3 선박네트워크 국제표준 적합 기관실모니터링시스템 개발)

  • Kim, Jong Hyun;Yu, Yung Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.2
    • /
    • pp.183-191
    • /
    • 2013
  • International network standards for SOLAS ship are composed of instrument network that controls and monitors machine in real time, shipboard control network that controls and monitors system through computer by human and telecommunication network that connects ship and shore. This paper describes development of stack for instrument network protocol complied with NMEA 2000 that is IEC 61162-3 international standards for SOLAS ship and also that of engine room monitoring system using the developed stack. Developed engine room monitoring system is certified by NMEA according to standards that require to pass about 1,600 test procedures.

Drop Time Evaluation for SMART Control Rod Assembly (스마트 제어봉집합체의 낙하시간 평가)

  • Kim, Kyoung-Rean;Jang, Ki-Jong;Park, Jin-Seok;Lee, Won-Jae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.2
    • /
    • pp.25-28
    • /
    • 2011
  • The control rod assemblies do freely fall into the reactor core by the gravity from the control rod drive mechanism. In order to achieve a rapid shutdown and control the reactor power, it is required to insert control rod assemblies as soon as possible. In this paper, we evaluated the drop time and flow characteristics caused around guide tube for SMART(System-integrated modular advanced reactor) control rod assembly. Numerical analyses are carried out with FLUENT program of computational fluid dynamics. This study results show that the drop time of the control rod assembly in the operating condition of SMART is more 20 percent rapidly than the drop time of the room temperature and ambient atmosphere condition.

Control of Softening of Long-Term Stored 'Fuji' Apples at Low Temperature and Subsequent Shelf-life by Combination Treatment of 1-MCP and Ethylene (1-MCP와 에틸렌 혼용처리가 장기간 저온저장 후 상온에 보관된 '후지' 사과의 연화 억제에 미치는 영향)

  • Choi, Hyun-Sug;Jung, Seok-Kyu
    • Journal of Bio-Environment Control
    • /
    • v.26 no.2
    • /
    • pp.108-114
    • /
    • 2017
  • The effect of 1-methylcyclopropene (1-MCP) at $1.0{\mu}L{\cdot}L^{-1}$ was compared with control and $10{\mu}L{\cdot}L^{-1}$ ethylene treatment to evaluate softening control of apple (Malus ${\times}$ domestica Borkh.) fruit for 180 days at $0.5^{\circ}C$ in the air, followed for 28 days at a room temperature. 1-MCP or 1-MCP+ethylene treatment maintained high fruit titratable acidity and firmness after 120 days during the cold storage, which was similarly observed for 28 days at a room temperature. 1-MCP treatment maintained fruit firmness more than 14 N during the cold storage and shelf-life at room temperature. Fruit surface red color was not consistently affected by the treatments during the cold storage but enhanced more than 4.0 by 1-MCP at 21- and 28-days of room temperature. Control or ethylene treatment advanced overall preceeding of fruit softening as rapid ethylene production and respiration rates at 90 days during the cold storage increased to a climacteric maximum. Therefore, pre 1-MCP-treated fruit maintained high fresh condition at a long-term low storage + approximately one month room temperature-storage under $10{\mu}L{\cdot}L^{-1}$ ethylene treatment.

A Study on Development of an Integration Methodology for Design Guideline of Advanced Information Display (개량형 정보표시 화면설계 지침의 일원화 방법론 개발에 관한 연구)

  • Jeong, Seong-Hae;Cha, U-Chang
    • Journal of the Ergonomics Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.13-24
    • /
    • 2004
  • Human error has brought about accidents more than 50% in system of a large size and complicated expecially in nuclear power plants(NPPs). The technology of Man Machine Interface(MMI) has been changed to the digitalized controls employing computer-based technology. According to this trend. the human factors guidelines are becoming main issue for reliable supports to digitalized information displays. However. the existing human factors guidelines is not enough for advanced information display on NPPs. The purpose of this research is to develop the reliable design and evaluation guidelines for advanced information display in main control room (MCR) of NPPs. In this study. the various general human factors guidelines concerning information display on CRT are integrated on data base management system. unified based on the integration rules. and applied in computer based procedures. The use of the integrated guidelines are expected to evaluate the existing information display on MCR in NPPs from the human factors point of view.

The Development and Application of a Training Base for the Installation and Adjustment of Photovoltaic Power Generation Systems

  • Chuanqing, SUN
    • International Journal of Advanced Culture Technology
    • /
    • v.4 no.1
    • /
    • pp.37-50
    • /
    • 2016
  • In recent years, the development and application of green energy resources have attracted more and more /$^*$ 'tention of people. The training room presented here is focused on the terminal applications of a photovoltaic power generation system (PPGS). Through introducing the composition and the general design principles, we aimed at leading the students to master the fundamental skills required for its design, installation and construction. The training room consists of numerous platforms, such as: PPGS, Wind and Photovoltaic Hybrid Power Generation Systems, Wind Power Generation Equipments, Simulative Grid-Connected Power Generation System, Electronic Technology Application of New Energy, etc. This enables the students to obtain their project and professional skills training via assembling, adjusting, maintaining and inspecting, etc., various component parts of the photovoltaic and new energy power generation systems, to further grasp the fundamental and related theoretical knowledge, and to further reinforce their practical and operational skills, so as to improve their problem-analyzing and problem-solving abilities.

The Development of Diesel Engine Room Fault Diagnosis System Using a Correlation Analysis Method (상관분석법에 의한 선박기관실 고장진단 시스템 개발)

  • Kim, Young-Il;Oh, Hyun-Kyung;Yu, Yung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.253-259
    • /
    • 2006
  • There is few study which automatically diagnoses the fault from ship's monitored data. The bigger control and monitoring system is. the more important fault diagnosis and maintenance is to reduce damage caused by system fault. This paper proposes fault diagnosis system using a correlation analysis algorithm which is able to diagnose and forecast the fault from monitored data and is composed of fault detection knowledge base and fault diagnosis knowledge base. For all kinds of ship's engine room monitored data are classified with combustion subsystem, heat exchange subsystem and electric motor and pump subsystem, To verify capability of fault detection, diagnosis and prediction, FMS(Fault Management System) is developed by C++. Simulation by FMS is carried out with population data set made by the log book data of 2 months duration from a large full container ship of H shipping company.

Practical Development and Evaluation of Advanced Alarm System for Nuclear Power Plant (원자력 플랜트의 개량형 경보시스템 개발 및 평가사례)

  • Jang Gui-Suk
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.12 no.4
    • /
    • pp.229-240
    • /
    • 2006
  • The advanced Alarm System (AS) employs modem digital technology to implement the alarm functions of the NPP(Nuclear Power Plant). The use of modem digital technology can provide advanced alarm processing in which new algorithms such as a signal validation, advanced alarm processing logic and other features are applied to improve the control room man-machine interfaces. This paper will describe the design process of the AS of NPP, improving the system reliability and availability using the reliability prediction tool, design strategies regarding the human performance topics associated with a computer-based AS and the results of the performance analysis using a prototype of the AS.

A Study on the Safe Position from the Local Fire in the Ship's Engine Rooms

  • Kim, Mann-Eun;Lee, Kyoung-Woo;Lee, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.446-454
    • /
    • 2008
  • Control devices for fire safety systems located in a engine room are to be arranged at a safe position which is easily accessible during a fire. To develop an interpretation for the safe position in engine rooms, calculation and experiments are carried out to determine a correlation between radiant heat and distance from fire in this paper. On the basis of results of this research, the control devices for a main engine are to be installed in the behind side of an obstruction to reduce radiant heat from the fire of the main engine. In case of other control devices, they are also to be provided in the same manner of control devices for the main engine or are to be placed with 5 meters far from fire hazards.

Non-Solvent Liquid Resin of Non-Discoloration Type at Room Temperature (비변색타입의 무용제형 상온 액상수지)

  • Moon, Jin-Bok;Mok, Dong-Yeop;Kim, Gu-Hyun
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.669-675
    • /
    • 2009
  • A study has been made on the preparation of liquid resin of non-solvent and non-discoloration type for replacement of the soft PVC at room temperature. A new synthetic process was developed by structure-control design of polyurethane synthesis using pre-polymer and polyols as curing agent. The optimum recipe was made according to macro-glycols, molecular weight and reaction conditions, and the final products indicated that the mechanical properties such as tensile strength, tear strength and flexibility was very excellent than PVC products. Also, viscosity, hardness and color operations of the final products can be controlled by this system. And yellowing property by UV and NOx gas was improved from the various additive experiment.