• Title/Summary/Keyword: adjusting coefficient

Search Result 143, Processing Time 0.019 seconds

Development of Forward Slip Model in Hot Strip Mill (강판의 열간압연 선진율 예측모델의 개발)

  • 문영훈;천명식;이준정
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.7
    • /
    • pp.1597-1603
    • /
    • 1995
  • A prediction model on forward slip has been developed for presetting rolling speed of each finish mill stand in the continuous hot strip roduction. Those factors such as neutral point, friction coefficient, volume fractions undergoing width spread, shape of deformation zone at each side of entry and delivery of the rolls were taken into account. To reduce the speed unbalance between adjacent stands a refining method of adjusting friction coefficient has also been developed. On-line application of the model showed a good agreement in rolling speeds between the predictions and the actual measurements, and gave an outstanding improvement in the travelling stability of strip passing through the finishing mill train.

Effects of the Floor Pannel on Flows in a Vertical Laminar Flow Type Clean Room (수직 층류형 클린룸의 바닥 패널이 실내기류에 미치는 영향)

  • Kang, S.H.;Jeon, W.P.;Oh, M.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.4
    • /
    • pp.303-315
    • /
    • 1990
  • Uniformity of velocity is quite important design points of a vertical laminar flow type clean room. In the present paper, flows in a room with a bottom pannel are numerically simulated by using a low-Reynolds number $k-{\epsilon}$ model, and a new flow model of the pannel are suggested. Resistance coefficient of the pannel and size of the exhaust channel show considerable effects on flow pattern and uniformity of flow on the bottom. Reflection coefficient also has important roles. A possibility to obtain the uniform and unidirectional flow is tested by adjusting the distribution of resistance coefficient of the pannel. Such a numerical simulation of the flow will be a good method to get optimun design parameters.

  • PDF

Microwave Dielectric Properties of the $BaO-(Nd,Bi)_2 O_3-TiO_2$$_2$ Ceramic for Mobile Communication Component (이동 통신 부품에 이용되는 $BaO-(Nd,Bi)_2 O_3-TiO_2$계 마이크로파 유전체의 유전 특성)

  • 윤중락;이헌용;김경용;이석원
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.11
    • /
    • pp.947-953
    • /
    • 1998
  • The microwave dielectric properties of X BaO-0.15($Nd_{0.87}Bi_{0.13})_2O_3-(0.85-X)TiO_2 (X=0.14~0.17) and 0.16BaO-0.15(Bi_xNd_{1-x})_2O_3-0.69TiO_2$ (X=0.12~0.15) ceramics sintered at 1320~$1380^{\circ}C$ were investigated. The microwave dielectric properties of X BaO-0.15(Nd_{0.87}Bi_{0.13})_2O_3-(0.85-X)TiO_2$ (X=0.14~0.17) can be controlled effectively by adjusting X content : with increasing X from 0.14 to 0.17 both dielectric constant and temperature coefficient of resonant frequency decreased from 94.6 to 86 and from 22 ppm/^${\circ}C to -7 ppm/^{\circ}C$, respectively, while quality factor increased from 1300 to 1920 (at 4GHz). The microwave dielectric properties of 0.16BaO-0.15(Bi_x/Nd_{1-x2}O_3 -0.69TiO_2$ (X=0.12~0.15) can be controlled effectively by adjusting X content : with increasing X from 0.12 to 0.15 both quality factor and temperature coefficient of resonant frequency decreased from 1920 to 1430 and from 9 ppm/^${\circ}C to -10 ppm/^{\circ}C$, respectively, while dielectric constant increased from 87.5 to 92.6.

  • PDF

Performance Analysis of Refrigeration System by Adjusting Manual Expansion Valve (수동식 팽창밸브 조정에 의한 냉동시스템의 성능 분석)

  • Yang, Hyung-Suk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.14 no.3
    • /
    • pp.113-119
    • /
    • 2011
  • This study analyzed facts affecting the performance of refrigeration systems after throttling actions, by changing the amount of refrigerant according to adjusting the opening of manual expansion valve to 80%, or 20% with vapor compressional refrigeration training equipment. At opening of 20%, the inlet and outlet temperature of compressor, subcooling and superheat, condenser heat, refrigeration effect, flash gas heat, coefficient of performance were higher, while at 80%, condensing pressure, evaporating pressure, compression work were higher, Thus, we could see changes in the amount of refrigerant affect the performance of the refrigeration system.

Modification of Design Response Spectra Considering Geotechnical Site Characteristics in Korea (국내 지반특성에 적합한 설계응답스펙트럼 개선을 위한 증폭계수 재산정에 대한 연구)

  • Yoon, Jong-Ku;Kim, Dong-Soo;Bang, Eun-Seok
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.113-124
    • /
    • 2006
  • Despite the site classification method was improved in the previous study, the response spectrum would be required to be modified by adjusting the integration interval to calculate the site coefficients because the response spectra did not match well the average spectral accelerations obtained by site response analyses in the range of long periods. In this paper, new response spectra for each site categories were determined by adjusting the integration interval of long-period site coefficient $F_{v}$ from $0.4{\sim}2.0$ to $0.4{\sim}1.5$ second. It matched well the average spectral accelerations and new response spectrum, and it was also improved compared to the current site classification system.

  • PDF

Characteristics of Flow Coefficients in an Engine Cylinder Head with a Quasi-steady Flow Condition by Continuous Variation of the Valve Lift (밸브 양정의 연속 변화에 의한 준정상 유동 조건에서의 엔진 실린더헤드 유량계수 특성)

  • Oh, Dae-San;Lee, Choong-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.22-27
    • /
    • 2010
  • Flow Coefficients of intake port in an engine cylinder head were measured by a newly designed flow rig. In measuring the flow coefficient with traditional method, the valve lift was manually varied by technician with adjusting a micrometer which is directly connected to the intake valve of the cylinder head. The cam shaft of the cylinder head is directly rotated by a step motor and the valve lift was automatically varied with cam shaft profile in the newly designed flow rig. The measurement of the flow coefficient was automated by rotating the cam shaft with the step motor. Automatic measurement of the flow coefficient could be safely measured by separating a technician from the noise and vibration of the traditional flow rig. Also, the automatic measurement of the flow coefficient reduce the measurement time and provide meaningful statistical data.

Performance Improvement Strategy for Parallel-operated Virtual Synchronous Generators in Microgrids

  • Zhang, Hui;Zhang, Ruixue;Sun, Kai;Feng, Wei
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.580-590
    • /
    • 2019
  • The concept of virtual synchronous generators (VSGs) is a valuable means for improving the frequency stability of microgrids (MGs). However, a great virtual inertia in a VSG's controller may cause power oscillation, thereby deteriorating system stability. In this study, a small-signal model of an MG with two paralleled VSGs is established, and a control strategy for maintaining a constant inertial time with an increasing active-frequency droop coefficient (m) is proposed on the basis of a root locus analysis. The power oscillation is suppressed by adjusting virtual synchronous reactance, damping coefficient, and load frequency coefficient under the same inertial time constant. In addition, the dynamic load distribution is sensitive to the controller parameters, especially under the parallel operation of VSGs with different capacities. Therefore, an active power increment method is introduced to improve the precision of active power sharing in dynamic response. Simulation and experimental is used to verify the theoretical analysis findings.

Experimental Study of Improving Electromagnetic Sound for Indoors side Package Air conditioner (패키지형 에어컨 실내기 자기음 개선을 위한 실험적 연구)

  • 김문섭;구형모;모진용;박득용;한형석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.138-140
    • /
    • 2003
  • In this paper, It is introduced to electromagnetic sound by AC motor and example of application by experiments. And Through adjusting some design parameter related to Mass, Damping coefficient and Stiffness of the system, we could find best design point to reduce motor total noise as well as noise component at AC power frequency (2f).

  • PDF

Association of PAH-DNA adducts and Urinary PAH metabolites influenced by polymorphisms of xenobiotic metabolism enzymes in industrial wase incinerating workers (산업폐기물 소각장 근로자에서 요중 PAHs 대사산물과 혈중 aromatic-DNA adducts)

  • ;Masayoshi Ichiba
    • Environmental Mutagens and Carcinogens
    • /
    • v.22 no.4
    • /
    • pp.303-311
    • /
    • 2002
  • This study evaluated the concentrations of urinary metabolites of polycyclic aromatic hydrocarbons (PAHs) in industrial waste incineration workers. The effect of genetic polymorphisms of xenobiotic metabolism enzymes on urinary concentration of PAH metabolites was assessed. And, aromatic DNA adduct levels were also determined in total white blood cells. Fifty employees were recruited from a company handling industrial wastes located in Ansan, Korea: non-exposed group (n=21), exposed group (n=29). Sixteen ambient PAHs were determined by GC/MSD (NIOSH method) from personal breathing zone samples of nine subjects near incinerators. Urinary 1-hydroxypyrene glucuronide (1-OHPG), a major pyrene metabolite, was assayed by synchronous fluorescence spectroscopy after immunoaffinity purification using monoclonal antibody 8E11 (SFS/IAC). Multiplex PCR was used for genotyping for GSTMI/TI and PCR-RFLP for genotyping of CYP1A1 (MspI and Ile/Val). PAH-DNA adducts in peripheral blood WBC were measured by the nuclease P1-enhanced postlabeling assay. Smoking habit, demographic and occupational information were collected by self-administered questionnaire. The range of total ambient PAH levels were 0.00-7.00 mg/㎥ (mean 3.31). Urinary 1-OHPG levels were significantly higher in workers handling industrial wastes than in those with presumed lower exposure to PAHs (p=0.006, by Kruskal-Wallis test). There was a statistically significant dose-response increase in 1-OHPG levels with the number of cigarettes consumed per day (Pearson correlation coefficient=0.686, p<0.001). Urinary 1-OHPG levels in occupationally exposed smoking workers were highest compared with non-occupationally exposed smokers (p=0.053, by Kruskal-Wallis test). Smoking and GSTMI genotype were significant predictors for log-transformed 1-OHPG by multiple regression analysis (overall model R²=0.565, p<0.001), whereas smoking was the only significant predictor for log-transformed aromatic DNA adducts (overall model R²=0.249, p=0.201). Aromatic DNA adducts was also a significantly correlation between log transferred urinary 1-OHPG levels (pearson's correlation coefficient=0.307, p=0.04). However, the partial correlation coefficient adjusting for Age, Sex, and cigarette consumption was not significant (r=0.154, p=0.169). The significant association exists only in individuals with the GSTMI null genotype (pearsons correlation coefficient=0.516, p=0.010; partial correlation coefficient adjusting for age, sex, and cigarette consumption, r=0.363, p=0.038). Our results suggest that the significant increase in urinary 1-OHPG in the exposed workers is due to higher prevalence of smokers among them, and that the association between urinary PAH metabolites and aromatic DNA adducts in workers of industrial waste handling may be modulated by GSTMI genotype. There results remain to be confirmed in future larger studies.

  • PDF

Prediction of Chlorine Residual in Water Distribution System (상수관망내 잔류염소농도 분포 예측)

  • Joo, Dae-Sung;Park, No-Suk;Park, Heek-Yung;Oh, Jung-Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.3
    • /
    • pp.118-124
    • /
    • 1998
  • To use chlorine residual as an surrogate parameter of the water quality change during the transportation in the water distribution system(WDS), the correct prediction model of chlorine residual must be established in advance. This paper shows the procedure and the result of applying the water quality model to the field WDS. To begin with, hydraulic model was calibrated and verified using fluoride as an tracer. And chlorine residual was predicted through simulation of water quality model. This predicted value was compared with the observed value. With adjusting the bulk decay coefficient(kb) and the wall decay coefficient(kw) according to the pipewall environment, the predicted chlorine residual can represent the observed value relatively well.

  • PDF