• Title/Summary/Keyword: adjacent structures

Search Result 721, Processing Time 0.022 seconds

Case Study of Damage Behavior in Urban Excavation (도심지 흙막이 굴착시 손상거동에 대한 대책공법사례)

  • Kim, Man-Ha;Chae, Young-Su;Kim, Hak-Moon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.330-335
    • /
    • 2005
  • Reliable predictions of the movement of earth retaining structures and the ground adjacent to braced walls in urban excavation are often difficult due to many variable factors. The ground settlement and the damage of adjacent structures in urban excavation has been an important issue. Therefore, the stability of the adjacent structures must be secured with the excavation support and research on the protection of adjacent structure is necessary. This study showed a countermeasure method for case of damage behavior in urban excavation.

  • PDF

Minimum Deficiency Ordering with the Clique Storage Structure (클릭저장구조에서 최소 부족수 순서화의 효율화)

  • Seol, Tong-Ryeol;Park, Chan-Kyoo;Park, Soon-Dal
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.24 no.3
    • /
    • pp.407-416
    • /
    • 1998
  • For fast Cholesky factorization, it is most important to reduce the number of nonzero elements by ordering methods. Generally, the minimum deficiency ordering produces less nonzero elements, but it is very slow. We propose an efficient implementation method. The minimum deficiency ordering requires much computations related to adjacent nodes. But, we reduce those computations by using indistinguishable nodes, the clique storage structures, and the explicit storage structures to compute deficiencies.

  • PDF

Seismic pounding between adjacent buildings considering soil-structure interaction

  • Raheem, Shehata E Abdel;Alazrak, Tarek M.A.;AbdelShafy, Aly G.A.;Ahmed, Mohamed M.;Gamal, Yasser A.S.
    • Earthquakes and Structures
    • /
    • v.20 no.1
    • /
    • pp.55-70
    • /
    • 2021
  • In urban cities, buildings were built in the neighborhood, these buildings influence each other through structure-soilstructure interaction (SSSI) and seismic pounding due to limited separation distance in-between. Generally, the effects of the interaction between soil and structure are disregarded during seismic design and analysis of superstructure. However, the system of soil-base adversely changes structural behavior and response demands. Thus, the vibration characteristics plus the seismic response of a building are not able to be independent of those in adjacent buildings. The interaction between structure, soil, and structure investigates the action of the attendance of adjacent buildings to the others by the interaction effect of the sub-soil under dynamic disturbances. The main purpose of this research is to analyze the effects of SSSI and seismic pounding on the behavior of adjacent buildings. The response of a single structure or two adjacent structures with shallow raft base lying on soft soil are studied. Three dimensions finite element models are developed to investigate the effects of pounding; gap distance; conditions of soil; stories number; a mass of adjacent building and ground excitation frequency on the seismic responses and vibration characteristics of the structures. The variation in the story displacement, story shear, and story moment responses demands are studied to evaluate the presence effect of the adjacent buildings. Numerical results acquired using conditions of soil models are compared with the condition of fixed support and adjacent building models to a single building model. The peak responses of story displacement, story moment, and story shear are studied.

Random vibration-based investigation of required separation gap between adjacent buildings

  • Atefeh Soleymani;Denise-Penelope N. Kontoni;Hashem Jahangir
    • Earthquakes and Structures
    • /
    • v.26 no.4
    • /
    • pp.285-297
    • /
    • 2024
  • Due to the imbalanced vibration of the adjacent buildings, the pounding phenomenon occurs as a result of an insufficient gap between them. Providing enough gap between adjacent structures is the most efficient approach to preventing the pounding effect. This paper calculated the required separation gaps between adjacent buildings, including two, four, eight, twelve and twenty stories steel moment-resisting frames, and investigated their related influencing parameters such as time periods, damping ratios, and the number of bays. The linear and nonlinear dynamic time-history analyses under real seismic event records were conducted to calculate the required separation gaps by obtaining relative displacement and velocity functions of two adjacent frames. The results showed that the required separation gap increased when the time periods of adjacent frames were not the same. The resulting separation gaps values of linear and nonlinear analyses were similar only for two and four stories frames. In other frames, the resulting separation gap values of linear analyses surpassed the corresponding nonlinear analyses. Although increasing the damping ratios in adjacent frames causes a decrease in the required separation gaps, the number of bays had no significant effect on them.

Integrated Optimal Design of Smart Connective Control System and Connected Buildings (스마트 연결 제어 시스템과 연결 구조물의 통합 최적 설계)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.2
    • /
    • pp.43-50
    • /
    • 2019
  • A smart connective control system was invented recently for coupling control of adjacent buildings. Previous studies on this topic focused on development of control algorithm for the smart connective control system and design method of control device. Usually, a smart control devices are applied to building structures after structural design. However, because structural characteristics of building structure with control devices changes, a iterative design is required for optimal design. To defeat this problem, an integrated optimal design method for a smart connective control system and connected buildings was proposed. For this purpose, an artificial seismic load was generated for control performance evaluation of the smart coupling control system. 20-story and 12-story adjacent buildings were used as example structures and an MR (magnetorheological) damper was used as a smart control device to connect adjacent two buildings. NSGA-II was used for multi-objective integrated optimization of structure-smart control device. Numerical simulation results show the integrated optimal design method proposed in this study can provide various optimal designs for smart connective control system and connected buildings presenting good control performance.

A Basic Study on Effect Analysis of Adjacent Structures due to Explosion of Underground Hydrogen Infrastructure (지하 수소인프라 폭발에 따른 인접 구조물 영향 분석에 대한 기초 연구)

  • Choi, Hyun-Jun;Kim, Sewon;Kim, YoungSeok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.21 no.3
    • /
    • pp.21-27
    • /
    • 2022
  • For carbon neutrality, interest in R&D and infrastructure construction for hydrogen energy, an eco-friendly energy source, is growing worldwide. In particular, for hydrogen stations installed in downtown areas, underground hydrogen infrastructure are being considered to increase a safety distance from hydrogen tank explosions to adjacent structures. In order to design an appropriate location and depth of the underground hydrogen infrastructure, it is necessary to evaluate the impact of the explosion of the underground hydrogen infrastructure on adjacent structures. In this paper, a numerical model was developed to analyze the effect of the underground hydrogen infrastructure explosion on adjacent structures, and the over pressure of the hydrogen tank was evaluated using the equivalent TNT (Trinitrotoluene) model. In addition, parametric analysis was performed to estimate the stability of adjacent structures according to the construction conditions of the underground hydrogen infrastructure.

Analysis on the Influence and Reinforcement Effect of Adjacent Pier Structures according to the Underpass Construction (지하차도 시공에 따른 인접 교각구조물 영향 및 보강효과 분석)

  • Lee, Donghyuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.4
    • /
    • pp.29-39
    • /
    • 2022
  • In order to solve the serious traffic congestion in seoul metropolitan city, large-scale underground space development such as underpasses, deep underground roads, and GTX (Great Train eXpress) is being carried out. In order to minimize the impact of the adjacent seoul metro line A pier foundation and stability due to the construction of the underground road in Seoul, earth retaining structures were reinforced and the foundation was reinforced as well. In this study, three-dimensional finite element mehtod analysis was performed to evaluate the effect on adjacent construction and to review the stability of the underpass excavation work. The reinforcement effect was quantitatively analyzed through numerical analysis. As a result of the analysis, compared to the result of performing the existing reinforcement when overlapping CIP and ground reinforcement grouting were performed, the displacement of the earth retaining structures was reduced by more than 50%, and stress of the foundation piles were also reduced by more than 45%. Based on the analysis of the numerical analysis results, it was confirmed that the displacement of the walls of earth retaining structures during adjacent construction should be strictly controlled.

Prognostic Analysis of Stage I Non-Small Cell Lung Cancer Abutting Adjacent Structures on Preoperative Computed Tomography

  • Soohwan Choi;Sun Kyun Ro;Seok Whan Moon
    • Journal of Chest Surgery
    • /
    • v.57 no.2
    • /
    • pp.136-144
    • /
    • 2024
  • Background: Early non-small cell lung cancer (NSCLC) that abuts adjacent structures requires careful evaluation due to its potential impact on postoperative outcomes and prognosis. We examined stage I NSCLC with invasion into adjacent structures, focusing on the prognostic implications after curative surgical resection. Methods: We retrospectively analyzed the records of 796 patients who underwent curative surgical resection for pathologic stage IA/IB NSCLC (i.e., visceral pleural invasion only) at a single center from 2008 to 2017. Patients were classified based on tumor abutment and then reclassified by the presence of visceral pleural invasion. Clinical characteristics, pathological features, and survival rates were compared. Results: The study included 181 patients with abutting NSCLC (22.7% of all participants) and 615 with non-abutting tumors (77.3%). Those with tumor abutment exhibited higher rates of non-adenocarcinoma (26.5% vs. 9.9%, p<0.01) and visceral/lymphatic/vascular invasion (30.4%/33.1%/12.7% vs. 8.5%/22.4%/5.7%, respectively; p<0.01) compared to those without abutment. Multivariable analysis identified lymphatic invasion and male sex as risk factors for overall survival (OS) and disease-free survival (DFS) in stage I NSCLC measuring 3 cm or smaller. Age, smoking history, vascular invasion, and recurrence emerged as risk factors for OS, whereas the presence of non-pure ground-glass opacity was a risk factor for DFS. Conclusion: NSCLC lesions 3 cm or smaller that abut adjacent structures present higher rates of various risk factors than non-abutting lesions, necessitating evaluation of tumor invasion into adjacent structures and lymph node metastasis. In isolation, however, the presence of tumor abutment without visceral pleural invasion does not constitute a risk factor.

Structure-soil-structure interaction in a group of buildings using 3D nonlinear analyses

  • Sharifi, Behroozeh;Nouri, Gholamreza;Ghanbari, Ali
    • Earthquakes and Structures
    • /
    • v.18 no.6
    • /
    • pp.667-675
    • /
    • 2020
  • The current study compares the effect of structure-soil-structure interaction (SSSI) on the dynamic responses of adjacent buildings and isolated structures including soil-structure interaction (SSI) with the responses of fixed-base structures. Structural responses such as the relative acceleration, displacement, drift and shear force were considered under earthquake ground motion excitation. For this purpose, 5-, 10- and 15-story structures with 2-bay moment resisting frames resting on shallow foundations were modeled as a group of buildings in soft soil media. Viscous lateral boundaries and interface elements were applied to the soil model to simulate semi-infinite soil media, frictional contact and probable slip under seismic excitation. The direct method was employed for fully nonlinear time-history dynamic analysis in OpenSees using 3D finite element soil-structure models with different building positions. The results showed that the responses of the grouped structures were strongly influenced by the adjacent structures. The responses were as much as 4 times greater for drift and 2.3 times greater for shear force than the responses of fixed-base models.