• 제목/요약/키워드: adjacent structures

검색결과 721건 처리시간 0.021초

Cone-beam computed tomography findings of impacted upper canines

  • Da Silva Santos, Ludmilla Mota;Bastos, Luana Costa;Oliveira-Santos, Christiano;Da Silva, Silvio Jose Albergaria;Neves, Frederico Sampaio;Campos, Paulo Sergio Flores
    • Imaging Science in Dentistry
    • /
    • 제44권4호
    • /
    • pp.287-292
    • /
    • 2014
  • Purpose: To describe the features of impacted upper canines and their relationship with adjacent structures through three-dimensional cone-beam computed tomography (CBCT) images. Materials and Methods: Using the CBCT scans of 79 upper impacted canines, we evaluated the following parameters: gender, unilateral/bilateral occurrence, location, presence and degree of root resorption of adjacent teeth (mild, moderate, or severe), root dilaceration, dental follicle width, and presence of other associated local conditions. Results: Most of the impacted canines were observed in females (56 cases), unilaterally (51 cases), and at a palatine location (53 cases). Root resorption in adjacent teeth and root dilaceration were observed in 55 and 47 impacted canines, respectively. In most of the cases, the width of the dental follicle of the canine was normal; it was abnormally wide in 20 cases. A statistically significant association was observed for all variables, except for root dilaceration (p=0.115) and the side of impaction (p=0.260). Conclusion: Root resorption of adjacent teeth was present in most cases of canine impaction, mostly affecting adjacent lateral incisors to a mild degree. A wide dental follicle of impacted canines was not associated with a higher incidence of external root resorption of adjacent teeth.

근접시공이 기초 구조물의 지지력 및 침하량에 미치는 영향 평가를 위한 실험 연구 (Experimental Study to Evaluate the Adjacent Construction Effect on the Bearing Capacity and Settlement of Nearby Foundation Structures)

  • 백문경;이상덕;장일한
    • 한국지반공학회논문집
    • /
    • 제37권8호
    • /
    • pp.15-24
    • /
    • 2021
  • 오늘날 도시 과밀화로 인해 한정된 부지를 효과적으로 사용하기 위해 기존 구조물과 인접한 조건에서 신규 구조물이 시공되는 경우가 많아지고 있다. 기존 구조물 근처에 신규 구조물이 시공되는 경우 기존 구조물에 의한 간섭효과가 발생할 수 있어, 이와 관련된 다양한 국내외 연구들이 진행되고 있지만 실험실 규모에서 모사할 수 있는 근접 구조물의 조건들이 한정적이라 실제 현장 조건을 제대로 반영하지 못하고 있다. 아울러 근접시공에 관한 명확한 기준과 역학적 거동이 규명되어 있지 않아 연구가 필요한 실정이다. 따라서 본 연구에서는 다양한 크기의 근접 구조물 시공 조건에 대한 지지력 및 침하량 변화를 관찰하기 위한 실험 연구를 수행하였다. 실험 결과 사질토 지반에서 구조물이 특정 거리 내에 근접 시공되는 경우 간섭효과로 인해 신규 구조물의 지지력 상승 효과가 확인되었으나 기존 구조물의 침하량이 증가하여 실제 근접 시공 시 면밀한 검토가 필요함을 확인하였다.

머신러닝 기반의 실시간 자동화계측 데이터 분석 기법 연구 (A Study on Machine Learning-Based Real-Time Automated Measurement Data Analysis Techniques)

  • 최정열;한재민;안대희;정지승;김정호;이성진
    • 문화기술의 융합
    • /
    • 제9권1호
    • /
    • pp.685-690
    • /
    • 2023
  • 도시의 인구증가 및 고밀화에 따라 기존 지하구조물에 인접하여 대심도 굴착 공사 물량이 증가하는 추세인 것으로 분석되었다. 현재 지하구조물 및 궤도는 외부요인에 의해 지하구조물의 손상이 다수 발생되는 실정이며 터널 내의 계측결과로 원인을 분석하여 예방차원이 아닌 사후처리에 대해서 측정을 하고 있는 실정이다. 본 연구의 목적은 공용중인 도시철도 선로와 인접한 굴착공사에 따른 구조물의 변형에 미치는 영향을 분석하는 것이다. 또한 외적 요인으로 인해 지하구조물 및 궤도 손상 및 파괴가 발생하기 전 구조물의 변위를 머신러닝 기법을 통해 구조물의 안전성을 평가하고자 한다. 분석결과, 분석한 데이터세트에서 구조물관리기준치에 도달하는 시간을 예측하기에 적합한 모델은 다항회귀 머신러닝 알고리즘인 것으로 분석되었다. 그러나 본 연구에서 적용한 자동화계측 데이터에 한정될 수 있으므로 추가적으로 구조물 조건의 다양성과 데이터양을 늘리는 향후 연구가 필요하다.

선형 점성 감쇠기가 장착된 인접구조물의 진동제어를 위한 유전자 알고리즘 기반 최적설계 (GA-Based Optimal Design for Vibration Control of Adjacent Structures with Linear Viscous Damping System)

  • 옥승용;김동석;고현무;박관순
    • 한국지진공학회논문집
    • /
    • 제11권1호
    • /
    • pp.11-19
    • /
    • 2007
  • 이 연구에서는 인접한 두 빌딩의 진동제어를 위한 방법으로 선형 점성 감쇠기의 위치별 용량의 최적설계방법을 제시하고자 한다. 기존 연구들에서는 감쇠기의 균등분포 또는 층별 감쇠비의 민감도에 비례하는 분포의 가정 하에서의 준최적(suboptimal) 설계문제를 다룬 반면, 이 연구에서는 감쇠기의 위치별 용량을 독립적인 설계인자로 고려함으로써 전역 최적해를 결정하는 최적화기법을 다루었다. 이를 위하여 넓은 영역에서 다수의 설계변수를 효율적으로 검색할 수 있는 유전자 알고리즘(genetic algorithm)을 도입하였으며, 제어 성능 및 감쇠용량에 대한 목적함수의 정의를 달리함으로써 얻어지는 여러 최적설계 결과를 상호 비교하여 보다 최적의 해를 구할 수 있는 목적함수를 정립하였다. 기존 연구결과와의 제어성능 및 감쇠용량의 비교를 통하여 제시하는 방법의 효율성을 검증하였다. 아울러 서로 상이한 주파수 성분을 띄는 실제 역사지진에 대한 시간이력해석을 통하여 제시하는 방법이 인접 구조물의 효과적인 제진설계방법이 될 수 있음을 입증하였다.

다목적 시스템식별을 이용한 모우드 불확실성이 있는 구조물의 강인 최적 감쇠기 설계 (Robust Optimal Damper Design of Structures with Modal Uncertainty Using Multi-Objective System Identification)

  • 정성운;옥승용;박원석;고현무
    • 한국안전학회지
    • /
    • 제27권1호
    • /
    • pp.76-85
    • /
    • 2012
  • This paper proposes a robust damper design technique for adjacent structures against model uncertainty. This approach introduces multi-objective optimization based system identification using measurement information which enables reasonable selection of the perturbation range in the robust design. Moreover, in order to improve the numerical efficiency in sampling the structural models required for the robust design of large structures, we define new objective functions which enable us to minimize the number of candidate models suitable to the purpose of the robust design. In addition, the performance index is newly employed to evaluate the robust performance of the sampled structural models, and the robust design has been performed according to the performance index. As a numerical example to demonstrate the efficiency of the proposed method, 5-story and 10-story two adjacent buildings are taken into account, and the existing and newly proposed robust design approaches are compared with each other. The results demonstrate that the proposed approach can guarantee more robust damper system only using small number of samples of the structural models because of using the measurement information which leads to improvement in the numerical efficiency, compared with the existing robust design methods.

Inter-story pounding between multistory reinforced concrete structures

  • Karayannis, Chris G.;Favvata, Maria J.
    • Structural Engineering and Mechanics
    • /
    • 제20권5호
    • /
    • pp.505-526
    • /
    • 2005
  • The influence of the inter-story structural pounding on the seismic behaviour of adjacent multistory reinforced concrete structures with unequal total heights and different story heights is investigated. Although inter-story pounding is a common case in practice, it has not been studied before in the literature as far as the authors are aware. Fifty two pounding cases, each one for two different seismic excitations, are examined. From the results it can be deduced that: (i) The most important issue in the inter-story pounding is the local effect on the external column of the tall building that suffers the impact from the upper floor slab of the adjacent shorter structure. (ii) The ductility demands for this column are increased comparing with the ones without the pounding effect. In the cases that the two buildings are in contact these demands appear to be critical since they are higher than the available ductility values. In the cases that there is a small distance between the interacting buildings the ductility demands of this column are also higher than the ones of the same column without the pounding effect but they appear to be lower than the available ductility values. (iii) It has to be stressed that in all the examined cases the developed shear forces of this column exceeded the shear strength. Thus, it can be concluded that in inter-story pounding cases the column that suffers the impact is always in a critical condition due to shear action and, furthermore, in the cases that the two structures are in contact from the beginning this column appears to be critical due to high ductility demands as well. The consequences of the impact can be very severe for the integrity of the column and may be a primary cause for the initiation of the collapse of the structure. This means that special measures have to be taken in the design process first for the critically increased shear demands and secondly for the high ductility demands.

Investigation of divergence tunnel excavation according to horizontal offsets between tunnels

  • Hong, Soon-Kyo;Oh, Dong-Wook;Kong, Suk-Min;Lee, Yong-Joo
    • Geomechanics and Engineering
    • /
    • 제21권2호
    • /
    • pp.111-122
    • /
    • 2020
  • In most cases in urban areas, construction of divergence tunnel should take into account proximity to existing tunnel in operation. This inevitably leads to deformation of adjacent structures and surrounding ground. Preceding researches mainly dealt with reinforcing of the diverging section for the stability including the pillar. This has limitations in investigating the interactive effects between existing structures and surrounding ground due to the excavation of the divergence tunnel. In this study, the complex interactive behavior of pile, the operating tunnel, and the surrounding ground according to horizontal offsets between the two adjacent tunnels was quantitatively analyzed based on conditions diverged from operating tunnel in urban areas. The effects on ground structures confirmed by analyzing the ground surface settlements, pile settlements, and the axial forces of the pile. The axial forces of lining in operating tunnel investigated to estimate their impact on existing tunnel. In addition, in order to identify the deformation of the surrounding ground, the close range photogrammetry applied to the laboratory model test for confirming the underground displacements. Two-dimensional finite element numerical analysis was also performed and compared with the results. It identified that the impact of excavating a divergence tunnel decreased as the horizontal offset increased. In particular, when the horizontal offset was larger than 1.0D (D is the diameter of operating tunnel), the impact on existing structures further reduced and the deformation of surrounding ground was concentrated at the top of the divergence tunnel.

스마트 스카이브릿지를 이용한 인접건물의 진동제어 (Vibration Control of Adjacent Buildings using a Smart Sky-bridge)

  • 강주원;채승훈;김현수
    • 한국공간구조학회논문집
    • /
    • 제10권4호
    • /
    • pp.93-102
    • /
    • 2010
  • 본 연구에서는 MR 감쇠기와 FPS를 사용하여 구성된 스마트 스카이브릿지를 제안하였으며 스마트 스카이브릿지로 연결된 인접건물의 지진응답 제어성능을 분석하였다. 이를 위하여 스마트 스카이브릿지로 연결된 10층과 20층 구조물을 예제 구조물로 선택하였고 근거리 (near fault) 및 원거리 (far fault) 지진의 특성을 가지는 El Centro 지진과 Kobe지진을 사용하여 시간이력해석을 수행하였다. 스마트 스카이브릿지블 효과적으로 제어하기 위해서 퍼지논리제어기를 개발하였으며 퍼지논리제어기를 최적화하기 위하여 다목적 유전자알고리즘을 사용하였다. 최적화결과 10층 건물의 지진응답과 20층 건물의 지진응답 사이에는 상충관계 (trade-off)가 있는 것을 알 수 있었고 다목적 유전자알고리즘을 통해서 두 건물의 지진응답 제어에 대한 퍼지논리제어거의 파레토 해집합을 구할 수 있었다. 수치해석결과 본 연구에서 제안한 스마트 스카이브릿지를 사용하면 연결된 건물의 지진응답을 효율적으로 저감시킬 수 있는 것을 알 수 있었다.

  • PDF

Seismic poundings of multi-story buildings isolated by TFPB against moat walls

  • Shakouri, Ayoub;Amiri, Gholamreza Ghodrati;Miri, Zahra Sadat;Lak, Hamed Rajaei
    • Earthquakes and Structures
    • /
    • 제20권3호
    • /
    • pp.295-307
    • /
    • 2021
  • The gap provided between adjacent structures in the metropolitan cities is mostly narrow due to architectural and financial issues. Consequently, structural pounding occurs between adjacent structures during earthquakes. It causes damages, ranging from minor local to more severe ones, especially in the case of seismically isolated buildings, due to their higher displacements. However, due to the increased flexibility of isolated buildings, the problem could become more detrimental to such structures. The effect of the seismic pounding of moat walls on the response of buildings isolated by Triple Friction Pendulum Bearing (TFPB) is investigated in this paper. To this propose, two symmetric three-dimensional models, including single-story and five-story buildings, are modeled in Opensees. Nonlinear Time History Analyses (NTHA) are performed for seismic evaluation. Also, five different sizes with four different sets of friction coefficients are considered for base isolators to cover a whole range of base isolation systems with various geometry configurations and fundamental period. The results are investigated in terms of base shear, buildings' drift, and roof acceleration. Results indicated a profound effect of poundings against moat walls. In situations of potential pounding, in some cases, the influence of impact on seismic responses of multistory buildings was more remarkable.