• Title/Summary/Keyword: adhesive layer

Search Result 542, Processing Time 0.039 seconds

Planar Type Flexible Piezoelectric Thin Film Energy Harvester Using Laser Lift-off

  • Noh, Myoung-Sub;Kang, Min-Gyu;Yoon, Seok Jin;Kang, Chong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.489.2-489.2
    • /
    • 2014
  • The planar type flexible piezoelectric energy harvesters (PEH) based on PbZr0.52Ti0.48O3 (PZT) thin films on the flexible substrates are demonstrated to convert mechanical energy to electrical energy. The planar type energy harvesters have been realized, which have an electrode pair on the PZT thin films. The PZT thin films were deposited on double side polished sapphire substrates using conventional RF-magnetron sputtering. The PZT thin films on the sapphire substrates were transferred by PDMS stamp with laser lift-off (LLO) process. KrF excimer laser (wavelength: 248nm) were used for the LLO process. The PDMS stamp was attached to the top of the PZT thin films and the excimer laser induced onto back side of the sapphire substrate to detach the thin films. The detached thin films on the PDMS stamp transferred to adhesive layer coated on the flexible polyimide substrate. Structural properties of the PZT thin films were characterized using X-ray diffraction (XRD) and scanning electron microscopy (SEM). To measure piezoelectric power generation characteristics, Au/Cr inter digital electrode (IDE) was formed on the PZT thin films using the e-beam evaporation. The ferroelectric and piezoelectric properties were measured by a ferroelectric test system (Precision Premier-II) and piezoelectric force microscopy (PFM), respectively. The output signals of the flexible PEHs were evaluated by electrometer (6517A, Keithley). In the result, the transferred PZT thin films showed the ferroelectric and piezoelectric characteristics without electrical degradation and the fabricated flexible PEHs generated an AC-type output power electrical energy during periodically bending and releasing motion. We expect that the flexible PEHs based on laser transferred PZT thin film is able to be applied on self-powered electronic devices in wireless sensor networks technologies. Also, it has a lot of potential for high performance flexible piezoelectric energy harvester.

  • PDF

Nkjet System 적용을 위한 유연 필름의 대기압 플라즈마 표면 처리 연구

  • Mun, Mu Kyeom;Yeom, Geun Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.162-162
    • /
    • 2014
  • 최근 들어 wearable computing에 대한 수요가 증가하면서 flexible device에 대한 연구가 활발히 진행되고 있다. 하지만, flexible device를 구현하기 위해서는 기판의 damage를 줄이기 위한 저온공정, device life-time 향상을 위한 passivation, 와이어 본딩 등 다양한 문제들이 해결 되어야 한다. 이러한 문제들 중, polymer 기판과 금속간의 접착력을 향상시키기 위해서 많은 연구자들은 기판의 표면에 adhesive layer를 도포하거나 금속잉크의 solvent를 변화시키는 등의 연구를 진행해왔다. 종래의 연구는 기존 device를 대체 할 수 있을 정도의 생산성과 polymer 기판에 대한 열 적인 손상 이 문제가 되었다. 종래의 문제를 해결하기 위하여 저온공정, in-line system이 가능한 준 준 대기압 플라즈마를 사용하였다. 본 연구에서는 금속잉크를 Ink-jet으로 jetting하여 와이어 본딩 하는 과정에서 전도성 ink의 선폭을 유지시키고 접착력을 향상하기 위하여 준 대기압 플라즈마 공정을 이용하여 이러한 문제점을 해결하고자 하였다. Polymer 기판 표면에 roughness를 만들기 위해 대략 수백 nm 크기를 갖는 graphene flake를 spray coating하여 마스크로 사용하고 준 대기압 플라즈마를 이용하여 표면을 식각 함으로써 roughness를 형성시켰다. 준 대기압 플라즈마를 발생시키기 위해 double discharge system에서 6 slm/1.5 slm (He/O2) gas composition을 하부 전극에 흘려보내고 60 kHz, 5 kV 파워를 인가하였다. 동시에 상부 전극에는 30 kHz, 5 kV 파워를 인가하여 110초 동안 표면 식각 공정을 진행하였다. Graphene flake mask가 coating되어 있는 유연기판을 산소 플라즈마 처리 한 후 물에 3초 동안 세척하여 표면에 남아있는 graphene flake를 제거하고 6 slm/0.3 slm (He/SF6)의 유량으로 주파수와 파워 모두 동일 조건으로 110초 동안 표면 처리를 하였다. Figure 1은 표면 개질 과정과 graphene flake를 mask로 사용하여 얻은 roughness 결과를 SEM을 이용하여 관찰한 결과이다. 이와 같이 실험한 결과 ink와 기판간의 접촉면적을 늘려주고 접촉 각을 조절하여 Wenzel model 을 형성 할 수 있는 표면 roughness를 생성하였고 표면의 화학적 결합을 C-F group으로 치환하여 표면의 물과 접촉각 이 $47^{\circ}$에서 $130^{\circ}$로 증가하는 것을 확인하였다.

  • PDF

Fabrication of Non Viral Vector for Drug and Gene Delivery using Particle Replication In Non-Wetting Templates (PRINT) Technique (Particle Replication In Non-Wetting Templates (PRINT) 방법을 이용한 약물 및 유전자 전달체의 제작)

  • Park, Ji-Young;Gratton, Stephanie;Benjamin, Maynor;Lim, Jomg Sung;Desimone, Joseph
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.493-499
    • /
    • 2007
  • Polymeric hydrogel particles were fabricated to demonstrate the scale-up possibilities with the Particle Replication In Non-wetting Templates (PRINT) process. A permanently etched, specifically designed master was made on a silicon wafer using conventional photolithography, then reactive ion etching. The master and substrate were used repeatedly to make a large number of identical elastomeric perfluoropolyethers (PFPE) replica molds. The PFPE replica molds were used to fabricate and harvest individual, monodisperse micron-sized particles using the PRINT process. A water-soluble polymer adhesive was used as a sacrificial layer for harvesting particles. Particles were composed of biodegradable poly (ethylene glycol) diacrylate (PEG-diA), and aminoethylacrylate (AEM) and 2-acryloxyethyltrimethyl ammonium chloride (AETMAC) were added to them for improving the uptake of the cells. This study suggested PRINT used to produce the uniformed and shape specific biodegradable polymer is the effective technique for the non viral vector for the drug and the gene delivery.

Phonosurgery after Laser Cordectomy (레이저 성문절제술 후의 음성수술)

  • So, Yoon-Kyung;Son, Young-Ik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.19 no.1
    • /
    • pp.11-15
    • /
    • 2008
  • Endoscopic laser cordectomy is known as an oncologically sound procedure for T1 and selected T2 glottic carcinoma ; it has comparable local control rate and better long-term laryngeal preservation rate when compared with those of radiotherapy. Even if results of the reported voice outcome studies after surgery or radiotherapy are diverse and controversial, resection deeper than the body layer of the vocal fold (type III, IV, V cordectomy) usually leads to aerodynamic insufficiency during phonation and results in poor voice quality. A keyhole defect or development of synechiae at the anterior commissure after type VI cordecomy may also result in unsatisfactory vocal outcome. However, many advances in phonosurgical techniques are reported to be successfully applied in the reconstruction of glottal defect that is subsequent to endoscopic laser cordectomy. In case of glottal insufficiency, voice restoration can be achieved by means of augmentation of the paraglottic space or medialization of the excavated vocal fold. Injection laryngoplasty with synthetic materials or autologous fat is gaining its popularity for restoring minor glottal volume defect because of its convenience. Laryngeal framework surgery, especially type I thyroplasty with premade implant systems or Gore-Tex, is most frequently used to correct larger glottic volume defect. In case of anterior commissural keyhole defect, additional procedure including laryngofissure may be required. For anterior commissural synechiae, laryngeal keel may be inserted for several weeks or mitomycin-C may be repeatedly applied after the division of adhesive scar to prevent restenosis. In this paper, current concepts and the authors' experiences of phonosurgical reconstruction of vocal function after endoscopic cordectomy will be introduced.

  • PDF

Finite Element Analysis and Validation for Mode I Interlaminar Fracture Behavior of Woven Fabric Composite for a Train Carbody Using CZM(Cohesive Zone Model) (CZM(Cohesive Zone Model)을 이용한 철도차량용 직물 복합재의 모우드 I 층간파괴의 해석적 연구)

  • Kim, Seung-Chul;Kim, Jung-Seol;Yoon, Hyuk-Jin;Seo, Seung-Il
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.719-724
    • /
    • 2009
  • In this study, DCB(double cantilever beam) specimens of woven fabric carbon/epoxy and glass/epoxy were manufactured and mode I fracture toughness of specimen was measured according to ASTM 5528-01. And FE analysis was conducted in the same condition and evaluated the behavior of delamination analytically. Mode I fracture toughness measured by test was $845.7\;J/m^2$ in the case carbon/epoxy and that of glass/epoxy was $1,042\;J/m^2$. FE analysis was conducted using cohesive elements for adhesive layer and applied measured fracture toughness. To verify the result of analysis, the reaction force measured at the end of specimen and that calculated by Timoshenko beam theory were compared. The numerical results show good agreements with the measured one.

A Study on Transparency and Characteristics of Natural Adhesives Made of Urushiol and Glue (우루시올과 아교를 배합한 천연 접착제의 투명성 및 접착 특성 연구)

  • Kim, Eun Kyung;Ahn, Sun Ah;Jang, Sungyoon
    • Journal of Conservation Science
    • /
    • v.31 no.2
    • /
    • pp.115-123
    • /
    • 2015
  • This study aims to increase the transparency of the natural adhesives made with lacquer and glue. For the purpose, samples were prepared by mixing urushiol with glue in varied proportion and the characteristics and adhesive properties were investigated. By adding glue on urushiol, IR spectra of the natural adhesives became similar to that of glue as the N-H band related with protein of glue increased, while that of methylene C-H bond related to urushiol decreased. Samples were dried within a day and maintained a bright color without blackening by oxidation during the curing process. The natural adhesives with urushiol and glue showed various range of viscosity and tensile shear strength as Cemedine C or Epoxy resin according to mixing ratio. In addition, the sample of mixing ratio of 6:4 showed bright and transparency in appearance and tensile shear strength similar to that of Araldite AY103-1/HY956 for earthenware layer.

A CONFOCAL LASER SCANNING MICROSCOPIC STUDY ON THE INTERFACE BETWEEN TOOTH COLORED RESTORATIVE MATERIALS AND DENTIN (공초점레이저주사현미경을 이용한 심미수복재와 상아질의 접착계면에 관한 연구)

  • Park, Byung-Chul;Cho, Young-Gon;Moon, Joo-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.313-320
    • /
    • 2000
  • The purpose of this study was to evaluate on the interfacial morphology between dentin and restorative materials. In this in vitro study, the cavity wall restorated with 3 different kinds of tooth colored restorative materials [resin-modified Glass Ionomer cement (Fuji II LC), composite resin (Z-100), compomer (Dyract)]. The thirty extracted human molar teeth without caries and/or restorations are used. The experimental teeth were randomly divided into three groups of ten teeth each. In each group, Wedge shaped cavities (width: 3mm, length: 2mm, depth: 1.5mm) were prepared at the cementoenamel junction on buccal and lingual surfaces. The adhesive of composite resin were mixed with rhodamine B. Primer of composite resin, Prime & Bond 2.1 of Dyract and liquid of Fuji II LC were mixed with fluorescein. In group 1, the cavity wall was treatment with dentin conditioner, and then restorated with Fuji II LC. In group 2, the cavity wall was treatment with Prime & Bond 2.1 and then restorated with Dyract. In group 3, the cavity wall was etching with 10% maleic acid, applied with primer and bonding agent and then restorated with Z-100. The interface between dentin and restorative materials was observed by fluoresence imaging with a confocal laser scanning microscope. The results were as follows : 1. In Glass ionomer group, adaptation of resin modified Glass-ionomer restoration against cavity wall is tight, but the crack formed inside of restoration were observed. 2. In Dyract group, the penetration of resin tag is shorter and the width of hybrid layer is narrower than composite resin group. 3. In Z-100 group, primer penetrated deeply through dentinal tubule. Also bonding agent was penetrated along the primer, but the penetration length is shorter than primer part, and in 3-D image, the resin tag is conical shape and lateral branch is observed.

  • PDF

Evaluation of Behavior of Composite Single Lap Joints with Different Finite Element Models (유한요소 모델에 따른 복합재 단일겹치기 접착 조인트부의 거동 평가)

  • Kim, Jung-Seok;Yoon, Hyuk-Jin;Hwang, Jae-Yeon;Yoon, Ji-You;Lee, Seung-Hun
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.6
    • /
    • pp.546-551
    • /
    • 2010
  • In this paper, the strain distribution of the bond layer has been compared with the experimental data and analyzed according to the different mesh refinements and element types. The mesh density was changed along the longitudinal direction of adherend, the longitudinal direction of overlapped region, the vertical direction of adherend, the vertical direction of adhesive and the width direction of the joint. In addition, the effect of the different types of element was evaluated using soild, shell and plane strain element. The geometric nonlinear analysis was performed to consider the large deformation of the joint. From the numerical result, at least 2 elements were needed to achieve a reliable result as the solid element used. In case of shell element, the peel strain at x/c=1 showed 22.8% error compared with the experiment but the shear strain showed a good agreement with the experiment within 1.67% error.

Analytic adherend deformation correction in the new ISO 11003-2 standard: Should it really be applied?

  • Ochsner, A.;Gegner, J.;Gracio, J.
    • Journal of Adhesion and Interface
    • /
    • v.5 no.2
    • /
    • pp.14-26
    • /
    • 2004
  • For reliable determination of mechanical characteristics of adhesively bonded joints used e.g. as input data for computer-aided design of complex components, the thick-adherend tensile-shear test according to ISO 11003-2 is the most important material testing method. Although the total displacement of the joint is measured across the polymer layer directly in the overlap zone in order to minimize the influence of the stepped adherends, the substrate deformation must be taken into account within the framework of the evaluation of the shear modulus and the maximum shear strain, at least when high-strength adhesives are applied. In the standard ISO 11003-2 version of 1993, it was prescribed to perform the substrate deformation correction by means of testing a one-piece reference specimen. The authors, however, pointed to the excessive demands on the measuring accuracy of the extensometers connected with this technique in industrial practice and alternatively proposed a numerical deformation analysis of a dummy specimen. This idea of a mathematical correction was included in the revised ISO 11003-2 version of 2001 but in the simplified form of an analytical method based on Hooke's law of elasticity for small strains. In the present work, it is shown that both calculation techniques yield considerably discordant results. As experimental assessment would require high-precision distance determination (e.g. laser extensometer), finite element analyses of the deformation behavior of the bonded joint are performed in order to estimate the accuracy of the obtained substrate deformation corrections. These simulations reveal that the numerical correction technique based on the finite element deformation modeling of the reference specimen leads to considerably more realistic results.

  • PDF

Interfacial Adhesion between Screen-Printed Ag and Epoxy Resin-Coated Polyimide (에폭시수지가 도포된 폴리이미드와 스크린 프린팅 Ag 사이의 계면접착력 평가)

  • Park, Sung-Cheol;Kim, Jae-Won;Kim, Ki-Hyun;Park, Se-Ho;Lee, Young-Min;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • The interfacial adhesion strengths between screen-printed Ag film and epoxy resin-coated polyimide were evaluated by $180^{\circ}$ peel test method. Measured peel strength value was initially around $164.0{\pm}24.4J/m^2$, while the heat treatment during 24h at $120^{\circ}C$ increase peel strength up to $220.8{\pm}19.2J/m^2$. $85^{\circ}C/85%$ RH temperature/humidity treatment decrease peel strength to $84.1{\pm}50.8J/m^2$, which seems to be attributed to hydrolysis bonding reaction mechanism between metal and adhesive epoxy resin coating layer.