• Title/Summary/Keyword: adhesion test

Search Result 1,107, Processing Time 0.029 seconds

Adhesive Properties of High Flowable SBR-modified Mortar for Concrete Patching Material Dependent on Surface Water Ratio of Concrete Substrate (콘크리트 피착체의 표면수율에 따른 단면복구용 고유동성 SBR 개질 모르타르의 부착특성)

  • Do, Jeong Yun;Kim, Doo Kie
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.124-134
    • /
    • 2013
  • This study investigated the effect of surface water on concrete substrate on adhesive strength in tension of very high flowable SBR-modified cement mortar. The specimens were prepared with proportionally mixing SBR latex, ordinary portland cement, silica sand, superplasticizer and viscosity enhancing agent. Polymer cement ratio (P/C) were 10, 20, 30, 50 and 75% and the weight ratio of fine aggregate to cement were 1:1 and 1:3. The specimens obtained with different P/C and C:F were characterized by unit weight, flow test, crack resistance and adhesion test. After basic tests, two mixtures of P/C=20% and 30% in case of C:F=1:1, and one mixture of P/C=50% in case of C:F=1:3 were selected, respectively. These three selected specimens were studied about the effect of surface water evenly sprayed on concrete substrate by a amount of 0, 0.006, 0.012, 0.017, 0.024g per unit area ($cm^2$) of concrete substrate surface The results show that surface water on concrete substrate increases the adhesive strength in tension of high flowable SBR-modified cement mortar and improve the flowability compared to the non-sprayed case.

Interfacial fracture Energy between Electroless Plated Ni film and Polyimide for Flexible PCB Applications (Flexible PCB용 무전해 도금 Ni 박막/Polyimide 계면파괴에너지 평가)

  • Min, Kyoung-Jin;Park, Sung-Cheol;Lee, Jee-Jeong;Lee, Kyu-Hwan;Lee, Gun-Hwan;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.1
    • /
    • pp.39-47
    • /
    • 2007
  • It is investigated how KOH and Rthylenediamine(EDA) treatment conditions on Polyimide film surface affect the interfacial fracture energy between electroless plated Ni and Polyimide film by $180^{\circ}$ peel test. Estimated values of interfacial fracture energy were 24.5 g/mm and 33.3 g/mm for the KOH treatment times under 1 and 5 minutes, respectively, while, those were 31.6 g/mm and 22.3 g/mm for EDA treatment times under 1 and 5 minutes, respectively. Interfacial bonding between electroless plated Ni and Polyimide seems to be dominated by chemical bonding effect rather than mechanical interlocking effect. It is found that chemical treatment produces carboxyl and mine functional groups which are closely related the interfacial bonding mechanism. Finally, it is speculated that interfacial fracture energy seems to be controlled by O=C-O bonding near cohesive failure region.

  • PDF

Silica Filler Addition Effect on the Ion Conductivity of PEO Composite Electrolytes Blended with Poly(ethylene imine) (폴리에틸렌 이민과 혼합된 PEO 복합체 전해질의 이온 전도도에 미치는 실리카 필러 첨가 효과)

  • Kim, Juhyun;Kim, Kwang Man;Lee, Young-Gi;Jung, Yongju;Kim, Seok
    • Korean Chemical Engineering Research
    • /
    • v.49 no.4
    • /
    • pp.465-469
    • /
    • 2011
  • In this study, poly(ethyleneoxide) and poly(ethylene imine) polymer blends containing fumed silica fillers were studied in order to enhance the ion conductivity and interfacial properties. Lithium perchlorate ($LiClO_4$) as a salt, and silica($SiO_2$) as the inorganic filler were introduced into the polymer composite electrolyte composites and the composites were examined to evaluate their ionic conductivity for a possibility test of electrolyte application. As the diameter of semicircle in an impedance test became smaller, ionic conductivity of composite electrolytes had been enhanced by addition of 20 wt% silica filler. However, the conductivity was not greatly changed over 20 wt% content because the silica was sufficiently saturated in the polymer electrolytes. Diffraction peaks of PEO became weaker with the addition of inorganic fillers using XRD analysis. It showed that a crystallinity was proportionally reduced by increasing filler contents. The morphology of composite electrolyte films has been investigated by SEM. The heterogeneous morphology which silica was evenly dispersed by the strong adhesion of PEI was shown at higher contents of silica.

A Study on the Surface-Modification of Barium Sulfate/TiO$_2$/Dimethicone Composite Powder and its Application in Color Cosmetics (바륨설페이트/티타늄디옥사이드/디메치콘의 복합화 및 메이크업에서의 응용)

  • Kyung-Ho, Choi;Seung-Yong, Ko;Hak-Hee, Kang;Ok-Sub, Lee
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.2
    • /
    • pp.197-200
    • /
    • 2004
  • Sensor and optical properties have become critical features in powder foundation. The flaky barium sulfate powder shows good smooth texture, adhesion and natural looking characteristics. However, it has limitations abilities in UV shielding, hiding and blooming effect. Thus we adopt TiO$_2$ that has excellent hiding power and blooming effect as well as UV shielding ability, but TiO$_2$ has still intrinsic problems in dispersion and texture. To overcome this disadvantages, the barium sulfate/TiO$_2$/dimethicone composite powder was prepared. The flaky barium sulfate powder was coated with TiO$_2$ in nanoscale and followed by coated with dimethicone. When this surface-modified powder was applied for make-up cosmetics, especially in powder foundation, the powder gave powder foundation more good characteristics than the original flaky barium sulfate, Ti02 powder, dimethicone in abovementioned optical and sensory properties. To characterize the distinctive features of this surface-modified powder, we measured its characteristics with UV in vitro tester, hiding powder test method, goniophotometer, consumer panel test and so on.

Laser Transmission Welding of Flexible Substrates and Evaluation of the Mechanical Properties (플렉서블 기판의 레이저 투과 용접 및 기계적 특성 평가)

  • Ko, Myeong-Jun;Sohn, Minjeong;Kim, Min-Su;Na, Jeehoo;Ju, Byeong-Kwon;Park, Young-Bae;Lee, Tae-Ik
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.2
    • /
    • pp.113-119
    • /
    • 2022
  • In order to improve the mechanical reliability of next-generation electronic devices including flexible, wearable devices, a high level of mechanical reliability is required at various flexible joints. Organic adhesive materials such as epoxy for bonding existing polymer substrates inevitably have an increase in the thickness of the joint and involve problems of thermodynamic damage due to repeated deformation and high temperature hardening. Therefore, it is required to develop a low-temperature bonding process to minimize the thickness of the joint and prevent thermal damage for flexible bonding. This study developed flexible laser transmission welding (f-LTW) that allows bonding of flexible substrates with flexibility, robustness, and low thermal damage. Carbon nanotube (CNT) is thin-film coated on a flexible substrate to reduce the thickness of the joint, and a local melt bonding process on the surface of a polymer substrate by heating a CNT dispersion beam laser has been developed. The laser process conditions were constructed to minimize the thermal damage of the substrate and the mechanism of forming a CNT junction with the polymer substrate. In addition, lap shear adhesion test, peel test, and repeated bending experiment were conducted to evaluate the strength and flexibility of the flexible bonding joint.

A Study on the Frictional Characteristics of Fiber Reinforced Composites under Corrosive Environment (부식 환경 하에서의 섬유강화복합재료의 마찰 및 마모 특성 연구)

  • Choong-Yong Park;Dong-Hyun Park;Soo-Jeong Park;Yun-Hae Kim
    • Composites Research
    • /
    • v.36 no.1
    • /
    • pp.37-41
    • /
    • 2023
  • The treated water inside the ballast electrolytic cell creates a highly alkaline atmosphere due to hydroxide generated at the DSA(Dimension Stable Anode) electrode during electrolysis. In this study, a composite material that can replace the weakness of the PE-coated steel pipe used in the existing ballast pipe was prepared. The test samples are BRE(Basalt fiber reinforced epoxy), BRP(Basalt fiber reinforced unsaturated polyester), GRE(Glass fiber reinforced epoxy), and GRP(Glass fiber reinforced unsaturated polyester). And then it was immersed in NaOH for 720 hours. The friction test of each specimen was conducted. The Friction coefficient analysis according to material friction depth and interfacial adhesion behavior between resin and fiber were analyzed. As a result, the mechanism of interfacial separation between resin and fiber could be analyzed. In the case of the unsaturated polyester resin with low interfacial bonding strength the longer the immersion time in the alkaline solution, the faster the internal deterioration caused by the deterioration that started from the surface, resulting in a decrease in the friction coefficient. It is hoped that this study will help to understand the degradation behavior of composite materials immersed in various chemical solutions such as NaOH, acid, and sodium hypochlorite in the future.

Evaluation of Bonding Performance of Hybrid Materials According to Laser and Plasma Surface Treatment (레이저 및 플라즈마 표면처리에 따른 이종소재 접합특성평가)

  • Minha Shin;Eun Sung Kim;Seong-Jong Kim
    • Composites Research
    • /
    • v.36 no.6
    • /
    • pp.441-447
    • /
    • 2023
  • Recently, as demand for high-strength, lightweight materials has increased, there has been great interest in joining with metals. In the case of mechanical bonding, such as bolting and riveting, chemical bonding using adhesives is attracting attention as stress concentration, cracks, and peeling occur. In this paper, surface treatment was performed to improve the adhesive strength, and the change in adhesive strength was analyzed. For the adhesive strength test were conducted with Carbon Fiber Reinforced Plastic(CFRP), CR340(Steel), and Al6061(Aluminum), and laser and plasma surface treatment were used. After plasma surface treatment, the adhesive strength improved by 7.3% and 39.2% in CFRP-CR340 and CFRP-Al6061, respectively. CR340-Al6061 was improved by 56.2% in laser surface treatment. Surface free energy(SFE) was measured by contact angle after plasma treatment, and it is thought that the adhesion strength was improved by minimizing damage through a chemical reaction mechanism. For laser surface treatment, it is thought that creates a rough bonding surface and improves adhesive strength due to the mechanical interlocking effect. Therefore, surface treatment is effect to improve adhesive strength, and based on this paper, the long-term fatigue test will be conducted to prevent fatigue failure, which is a representative cause of actual structural damage.

Evaluation of Wear Characteristics of Low-alloy Steel Brake Discs for High Energy Capacity (고에너지용 저합금강 제동디스크의 마모 특성 평가)

  • Dong-gyu Lee;Kyung-il Kim;Gue-Serb Cho;Kyung-taek Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.4
    • /
    • pp.532-537
    • /
    • 2024
  • In this study, wear characteristics and microstructure changes due to changes in alloy composition of Ni-Cr-Mo-V and Ni-Cr-Mo low-alloy steels used in brake discs for transportation system such as aircraft and high-speed trains. As a result of the hardness test, the hardness of C-Mo-V steel was the highest at 39.4±0.9HRc, and the hardness of Ni-Cr-Mo steel was the lowest at 32.4±0.6HRc. The friction coefficient tended to decrease as the vertical load increased. At a vertical load of 1 N, the friction coefficient of Ni-Cr-Mo steel was the highest at 0.842, and at a vertical load of 5 N, Mn-Cr-V steel was the highest at 0.696. Ni-Cr-Mo showed the largest wear scar width, depth, and wear amount, with a width of 711 ㎛, a depth of 8.24 ㎛, and a wear amount of 11 mg under a vertical load of 1 N, and a width of 1,017 ㎛, a depth of 19.17 ㎛, and a wear amount of 17 mg under a vertical load of 5 N. As a result of wear mechanism analysis, ploughing, delamination, and adhesion in all specimens, with plastic deformation being more prominently observed in Ni-Cr-Mo.

THE EFFECTS OF PASTE TYPE CALCIUM SULFATE ON THE PERIODONTAL HEALING OF 3-WALL INTRABONY DEFECTS IN DOGS (성견 3면 골내낭에서 Paste형 Calcium Sulfate 가 치주조직 치유에 미치는 영향)

  • Hyun, Suk-Ju;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.429-455
    • /
    • 2002
  • There are numerous kind of materials and techniques to regenerate the periodontal tissue which has been lost due to destructive periodontal disease, including bone graft material. Many bone graft materials have been reported and among these materials, synthetic material has been developed fin the long time because of its sufficient supply economically. Calcium sulfate which was evaluated as including much calcium, has been used in the clinical field. In the dental field calcium sulfate has been used as bone graft material and Kim reported that improved bone formation and more amount of new attachment after grafting calcium sulfate. but, because calcium sulfate has the problem that it generates the heat in setting period and resolves fast, we need to evaluate the effect of the improved calcium sulfate on periodontal tissue. The present study evaluates the effect of paste type calcium sulfate on the epithelial migration, alveolar bone regeneration, cementum formation and gingival connective tissue attachment in intrabony defect in dogs. Four millimeter deep and four millimeter wide 3-wall defects were surgically created in the mesial or distal aspects of premolars or molars. the test group received paste-type calcium sulfate with a flap procedure and the control group underwent flap procedure only. Histologic analysis after 8 weeks of healing revealed the following results : 1. The length of epithelial growth(the distance from CEJ to the apical end of JE) was 0.52${\pm}$0.26mm in the control and 0.56${\pm}$0.25mm in the test group. there was no statistically significant difference between the two groups. 2. The length of connective tissue adhesion was 1.74${\pm}$1.06mm in the control and 1.28${\pm}$0.57mm in the test group. there was no statistically significant difference between the two groups. 3. The length of new bone was 2.01${\pm}$0.95mm in the control and 2.62${\pm}$0.81mm in the test group. there was no statistically significant difference between the two groups. 4. The length of new cementum was 1.86${\pm}$0.80mm in the control and 2.77${\pm}$ 0.86mm in the test group. there was a statistically significant difference between the two groups.(P<0.01) These results suggest that the use of paste type calcium sulfate in 3-wall intrabony defects has significant effect on new cementum formation , but doesn't have any significant effect on the prevention of junctional epithelium migration and new bone formation. Finally, the paste type calcium sulfate that is used in this study is suggested to be the material that can have a significant effect on the periodontal healing, if its biocompatibility is improved.

The effects of decalcification time of demineralized freeze-dried bone on the healing of 3-wall intrabony defects in dogs (탈회시간에 따른 탈회 냉동 건조골이식이 성견 3면 골내낭의 치유에 미치는 영향)

  • Kim, Chang-Sung;Cho, Kyoo-Sung;Kim, Chong-Kwan;Chai, Jung-Kiu
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.4
    • /
    • pp.779-797
    • /
    • 1996
  • The present study investigated the effects of variations in decalcification time of demineralized freeze-dried bone on the osteogenic potential of DFDB. Sixteen 3-wall intrabony defects with 4mm depth were surgically created in the mesial aspect of upper and lower anterior teeth of 4 dogs. Following the flap procedure, three test groups with 4 defects each received either freeze-dried bone graft (Group I), demineralized freeze-dried bone graft decalcified for 12hours (Group II), or demineralized freeze-dried bone graft decalcified for 24hours(Group III). The rest of the four defects received the flap procedure-only as the control group. The healing was histologically analyzed after 14 weeks on the length of connective tissue adhesion, new bone formation and new cementum formation. The results were as follows: 1. The length of connective tissue adhesion showed no statistically significant difference in all groups with $0.62{\pm}0.14mm$ for Control, $0.42{\pm}0.11mm$ for Group I, $0.63{\pm}0.43mm$ for Group II and $0.52{\pm}0.11mm$ for Group III. 2. The new bone formation showed no statistically significant difference in all groups with $3.17{\pm}0.24mm$ for Control. $3.15{\pm}0.56mm$ for Group I. $3.22{\pm}0.36mm$ for Group II, and $3.28{\pm}0.74mm$ for Group III. 3. The new cementum formation showed no statistically significant difference in all groups with $4.19{\pm}0.46mm$ for Control, $3.23{\pm}0.64mm$ for Group I, $4.13{\pm}1.82mm$ for Group II. and $3.13{\pm}0.62mm$ for Group III.

  • PDF