• Title/Summary/Keyword: adapted therapy

Search Result 74, Processing Time 0.023 seconds

Evaluating applicability of metal artifact reduction algorithm for head & neck radiation treatment planning CT (Metal artifact reduction algorithm의 두경부 CT에 대한 적용 가능성 평가)

  • Son, Sang Jun;Park, Jang Pil;Kim, Min Jeong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.107-114
    • /
    • 2014
  • Purpose : The purpose of this study is evaluation for the applicability of O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands) in head & neck radiation treatment planning CT with metal artifact created by dental implant. Materials and Methods : All of the in this study's CT images were scanned by Brilliance Big Bore CT(Philips, Netherlands) at 120kVp, 2mm sliced and Metal artifact reduced by O-MAR. To compare the original and reconstructed CT images worked on RTPS(Eclipse ver 10.0.42, Varian, USA). In order to test the basic performance of the O-MAR, The phantom was made to create metal artifact by dental implant and other phantoms used for without artifact images. To measure a difference of HU in with artifact images and without artifact images, homogeneous phantom and inhomogeneous phantoms were used with cerrobend rods. Each of images were compared a difference of HU in ROIs. And also, 1 case of patient's original CT image applied O-MAR and density corrected CT were evaluated for dose distributions with SNC Patient(Sun Nuclear Co., USA). Results : In cases of head&neck phantom, the difference of dose distibution is appeared 99.8% gamma passing rate(criteria 2 mm / 2%) between original and CT images applied O-MAR. And 98.5% appeared in patient case, among original CT, O-MAR and density corrected CT. The difference of total dose distribution is less than 2% that appeared both phantom and patient case study. Though the dose deviations are little, there are still matters to discuss that the dose deviations are concentrated so locally. In this study, The quality of all images applied O-MAR was improved. Unexpectedly, Increase of max. HU was founded in air cavity of the O-MAR images compare to cavity of the original images and wrong corrections were appeared, too. Conclusion : The result of study assuming restrained case of O-MAR adapted to near skin and low density area, it appeared image distortion and artifact correction simultaneously. In O-MAR CT, air cavity area even turned tissue HU by wrong correction was founded, too. Consequentially, It seems O-MAR algorithm is not perfect to distinguish air cavity and photon starvation artifact. Nevertheless, the differences of HU and dose distribution are not a huge that is not suitable for clinical use. And there are more advantages in clinic for improved quality of CT images and DRRs, precision of contouring OARs or tumors and correcting artifact area. So original and O-MAR CT must be used together in clinic for more accurate treatment plan.

An Analysis of Child Care and Education Teacher's Current Practices and Difficulties in Supporting Children with Problem Behaviors (국공립 어린이집 재원 유아의 문제행동과 교사의 현재 교수 실태 및 지원요구에 대한 탐색)

  • Lee, Yeon Jeong;Cho, Youn Kyung
    • Korean Journal of Childcare and Education
    • /
    • v.10 no.3
    • /
    • pp.5-29
    • /
    • 2014
  • The purpose of this study was to find out various problem behaviors of children who were not diagnosed with any disability, but instead, engaged in problem behaviors. This study also intended to review the difficulties of children with problem behaviors, their teachers' difficulties and needs, to suggest support for child care and education teachers. This study conducted semi-structured qualitative interviews with eight child care and education teachers. The interviews were transcribed into text and analyzed by contents. The results of this study are as follows. Problem behaviors of children described by teachers were classified into external and internal types. In addition, children with problem behaviors had experienced difficulties in maintaining relationships with their teachers, peers and parents. Many teachers were not successful to provide appropriate support for preschoolers who demonstrated problem behaviors in classrooms or some teachers provided individualized support. Teachers adapted the behavioral and the psychological approaches to problem behaviors of preschoolers. However, teachers reported difficulties with children with problem behavior and brought up the following issues on teaching children with problem behaviors; managing troubled matters happening in the class, difficulty in controlling teacher's emotions on problem behaviors, the lack of time, the integrated child care time without teacher in charge of child, the interruption in activity progress, the lack of a special way to deal with problem behaviors, and difficulty in cooperation with families through parents-teacher counseling sessions. Teachers counseled with parents who had a child with problem behaviors and revealed that parents reacted to problem behaviors in various ways such as embarrassment, acceptance, ignorance, or avoidance. Most teachers received assistance and support for teaching children with problem behaviors, from families, local communities and in-service training. Lastly, teachers with preschoolers with problem behaviors needed the support of experts on managing behavior problems, assistant teaching personnel, education for parents and teachers, respects for teachers, psychological counseling or play therapy from professional service agencies, diagnosis service at child care and education centers which children attended, and support networking with agencies. Teachers also required the family support of medical diagnosis and psychological counseling and financial support from the government.

A study anxiety of mothers who have hospitalized ill children Focusing on the comparison of korean mothers with multicultural family mothers (입원 환아 어머니의 불안에 관한 연구: 한국인 어머니와 다문화가정 어머니 비교를 중심으로)

  • Oh, Jae-Woo;Moon, Young-Sook
    • Journal of Digital Convergence
    • /
    • v.10 no.6
    • /
    • pp.311-319
    • /
    • 2012
  • This study, by grasping the degree of anxiety of Korean mothers and multicultural family mothers because of their hospitalized children, was aimed to arrange the basic data for developing the program to help the mothers of Korea and multicultural family reduce the anxiety happening due to the hospitalization of their children and adapt to their environment. Methods: The subjects of the study were a total of 200 people composed of 100 multicultural family mothers, and 100 Korean mothers respectively whose children were hospitalized in the pediatric department of K university hospital located in Daejeon City. And the period of data collection was from Aug 1, 2010 to Aug 31, 2010.As a study tool, the measuring tool of Kim Jeong Taek(1978), which STAI of Sielberger(1972) was adapted to Koreans, was used.The collected data was analyzed using SPSS WIN 12.0. Results. A result of the state anxiety of the Korean mothers with that of the multicultural family mothers of the inpatient children, Korean mothers 2.11, multicultural family mothers 2.17, result of temperament anxiety showed Korean mothers 2.09, multicultural family mothers 1.94. As a result of comparing the anxiety of the Korean mothers with that of the multicultural family mothers of the inpatient children, there was no difference between groups in both temperament anxiety and state anxiety. In a situation of anxiety, when there was no explanation of the treatment or therapy, both Korean mothers and multicultural family mothers showed the severe anxiety. In the degree of anxiety according to the general characteristics of the mothers of the inpatient children, there was not a statistically significant result in anxiety according to general characteristics of the inpatient children of korean family mothers, there was a significant difference in state anxiety according to the state of average monthly income in Korean mothers(P<.05), however, there was a significant one in temperament anxiety in the course of perceiving a test method in multicultural family mothers(P<.05). In the degree of anxiety according to the general characteristics of the mothers of the inpatient children, there was a significant difference in state anxiety according to the state of average monthly income in Korean mothers(P<.05), however, there was a significant one in temperament anxiety in the course of perceiving a test method in multicultural family mothers(P<.05). Conclusion: Through the results of the study above, no matter what socio-demographic characteristics of the mothers of the inpatient children are, regardless of the general characteristics of the inpatient children, it was found out that most of mothers felt anxiety.

Verification of Radiation Therapy Planning Dose Based on Electron Density Correction of CT Number: XiO Experiments (컴퓨터영상의 전자밀도보정에 근거한 치료선량확인: XiO 실험)

  • Choi Tae-Jin;Kim Jin-Hee;Kim Ok-Bae
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.105-113
    • /
    • 2006
  • This study peformed to confirm the corrected dose In different electron density materials using the superposition/FFT convolution method in radiotherapy Planning system. The experiments of the $K_2HPO_4$ diluted solution for bone substitute, Cork for lung and n-Glucose for soft tissue are very close to effective atomic number of tissue materials. The image data acquisited from the 110 KVp and 130 KVp CT scanner (Siemes, Singo emotions). The electron density was derived from the CT number (H) and adapted to planning system (Xio, CMS) for heterogeneity correction. The heterogeneity tissue phantom used for measurement dose comparison to that of delivered computer planning system. In the results, this investigations showed the CT number is highly affected in photoelectric effect in high Z materials. The electron density in a given energy spectrum showed the relation of first order as a function of H in soft tissue and bone materials, respectively. In our experiments, the ratio of electron density as a function of H was obtained the 0.001026H+1.00 in soft tissue and 0.000304H+1.07 for bone at 130 KVp spectrum and showed 0.000274H+1.10 for bone tissue in low 110 KVp. This experiments of electron density calibrations from CT number used to decide depth and length of photon transportation. The Computed superposition and FFT convolution dose showed very close to measurements within 1.0% discrepancy in homogeneous phantom for 6 and 15 MV X rays, but it showed -5.0% large discrepancy in FFT convolution for bone tissue correction of 6 MV X rays. In this experiments, the evaluated doses showed acceptable discrepancy within -1.2% of average for lung and -2.9% for bone equivalent materials with superposition method in 6 MV X rays. However the FFT convolution method showed more a large discrepancy than superposition in the low electron density medium in 6 and 15 MV X rays. As the CT number depends on energy spectrum of X rays, it should be confirm gradient of function of CT number-electron density regularly.

  • PDF