• 제목/요약/키워드: actual concrete structures

검색결과 244건 처리시간 0.026초

재생골재를 사용한 구조용 콘크리트의 성능평가 (Performance Evaluation of Structural Concrete Using Recycled Aggregate)

  • 박희곤;배연기;이재삼;이영도;임남기;정상진
    • 한국건축시공학회지
    • /
    • 제7권2호통권24호
    • /
    • pp.85-92
    • /
    • 2007
  • In the past, recycled aggregate was used very limitedly in low value-added areas such as the base layer of roads. However, in response to the shortage of natural aggregate, high consciousness of resource saving and changed idea on environment, the quality of recycled aggregate has been improved considerably, and the percentage of recycled construction waste is increasing every year compared to simple landfill or incineration. Recently the Act on the Promotion of Construction Waste Recycling was enacted on December 2003 for the efficient use of recycled aggregate, and the Standards for the Quality of Recycled Aggregate for Concrete (Proposal) were announced in order to use and manage recycled aggregate according to quality. According to the Standards for the Quality of Recycled Aggregate for Concrete (Proposal), it is recommended to substitute recycled coarse aggregate and fine aggregate below 30% each. However, compared to the trend of recycling, the recycling rate of aggregate is still quite low. It is because of low performance of recycled aggregate, users' lack of understanding, etc. These problems basically come from the decrease of strength of recycled concrete resulting from the use of recycled aggregate, and recycled aggregate is still considered not reliable because there have been not many cases of actual application. If the basic problem of strength decrease is solved and data on recycled aggregate is provided through actual field placing, we may maximize the use of recycled aggregate. Thus, in order to maximize the use of recycled aggregate that satisfy the recycled aggregate quality standards, the present study made a mock-up similar to real structures, evaluated its performance and examined the field applicability of recycled aggregate concrete.

XFINAS 계면요소와 고체요소를 이용한 콘크리트-강재 합성구조물의 비선형 거동해석 (Nonlinear Analysis of Steel-Concrete Composite Structures using XFINAS Interface and Solid Elements)

  • 김기두;수타스트라디트 송삭;박종화;박재균
    • 한국전산구조공학회논문집
    • /
    • 제23권3호
    • /
    • pp.267-274
    • /
    • 2010
  • 합성구조는 전체가 동일한 재료 특성을 가지는 구조와는 달리 서로 다른 특성 즉 강재와 콘크리트의 구조로 결합되어 있다. 따라서 실제 모델링 시 이러한 재료 특성을 반영하지 않으면 실제 거동을 예측할 수 없으므로 콘크리트와 강재 사이에 인터페이스 요소를 연결하여 강재와 콘크리트의 슬립을 예측할 수 있게 한다. 인터페이스 요소는 일반적으로 사용되는 구성방정식은 적합하지 않고 실제 부착 및 슬립을 고려한 비선형 구성 방정식을 사용하여야만 적절히 사용할 수 있다. 이 계면요소를 이용하여 판형 강재 박스와 콘크리트의 접촉면을 묘사하였다. 그리고 강재 박스의 휨-좌굴 거동을 묘사하기 위해서는 일반적인 8절점 적합 요소의 사용은 부적절하므로 판형 강재 박스는 보강 변형도(Enhanced Assumed Strain) 고체요소를 사용하여 휨거동을 묘사할 수 있게 하였다.

Maximum axial load level and minimum confinement for limited ductility design of high-strength concrete columns

  • Lam, J.Y.K.;Ho, J.C.M.;Kwan, A.K.H.
    • Computers and Concrete
    • /
    • 제6권5호
    • /
    • pp.357-376
    • /
    • 2009
  • In the design of concrete columns, it is important to provide some nominal flexural ductility even for structures not subjected to earthquake attack. Currently, the nominal flexural ductility is provided by imposing empirical deemed-to-satisfy rules, which limit the minimum size and maximum spacing of the confining reinforcement. However, these existing empirical rules have the major shortcoming that the actual level of flexural ductility provided is not consistent, being generally lower at higher concrete strength or higher axial load level. Hence, for high-strength concrete columns subjected to high axial loads, these existing rules are unsafe. Herein, the combined effects of concrete strength, axial load level, confining pressure and longitudinal steel ratio on the flexural ductility are evaluated using nonlinear moment-curvature analysis. Based on the numerical results, a new design method that provides a consistent level of nominal flexural ductility by imposing an upper limit to the axial load level or a lower limit to the confining pressure is developed. Lastly, two formulas and one design chart for direct evaluation of the maximum axial load level and minimum confining pressure are produced.

플라이애쉬의 치환율에 따른 고강도 자기충전 콘크리트의 특성 (Properties of the high strength and self-compacting concrete according to the replacement ratio of fly ash)

  • 권영호;이현호;이화진;하재담
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.85-88
    • /
    • 2006
  • This study describes the optimum mix proportion of the high strength and self-compacting concrete placed in main structures of LNG above tank. This concrete requires high strength level about $60{\sim}80MPa$, low hydration heat, balance between workability and consistency without vibrating in the actual work. For this purpose, low heat portland cement and fly ash are selected and design factors including water-binder ratio, replacement ratio of fly ash are tested. As experimental results, low heat portland cement shows lower the confined water ratio than another cement type and the optimum replacement ratio of fly ash in order to improve properties of the binder-paste shows 10% by cement weight considering test results of the confined water ratio$({\beta}p)$. Also, flowability of the high strength and self-compacting concrete by using fly ash about $10{\sim}20%$ is improved. The replacement ratio of fly ash 10% and water-binder ratio $25{\sim}27%$ are suitable to the design strength 80MPa and cost, In case of the design strength 60MPa, the replacement ratio of fly ash and water-binder ratio show 20% and $25{\sim}30%$ separately. Based on the results of this study, the optimum mix proportions of the high strength and self-compacting concrete will be applied to the construction of LNG above tank as a new type.

  • PDF

Numerical study of concrete-encased CFST under preload followed by sustained service load

  • Li, Gen;Hou, Chao;Han, Lin-Hai;Shen, Luming
    • Steel and Composite Structures
    • /
    • 제35권1호
    • /
    • pp.93-109
    • /
    • 2020
  • Developed from conventional concrete filled steel tubular (CFST) members, concrete-encased CFST has attracted growing attention in building and bridge practices. In actual construction, the inner CFST is erected prior to the casting of the outer reinforced concrete part to support the construction preload, after which the whole composite member is under sustained service load. The complex loading sequence leads to highly nonlinear material interaction and consequently complicated structural performance. This paper studies the full-range behaviour of concrete-encased CFST columns with initial preload on inner CFST followed by sustained service load over the whole composite section. Validated against the reported data obtained from specifically designed tests, a finite element analysis model is developed to investigate the detailed structural behaviour in terms of ultimate strength, load distribution, material interaction and strain development. Parametric analysis is then carried out to evaluate the impact of significant factors on the structural behaviour of the composite columns. Finally, a simplified design method for estimating the sectional capacity of concrete-encased CFST is proposed, with the combined influences of construction preload and sustained service load being taken into account. The feasibility of the developed method is validated against both the test data and the simulation results.

Experimental Determination of Concrete Fracture Properties with Modified S-FPZ Model

  • Yon, Jung-Heum;Kim, Tai-Hoon
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권3E호
    • /
    • pp.213-219
    • /
    • 2006
  • Modified singular fracture process zone(S-FPZ) model is proposed in this paper to determine a fracture criterion for continuous crack propagation in concrete. The investigated fracture properties of the proposed fracture model are strain energy release rate at a micro-crack tip and the relationship between crack closure stress(CCS) and crack opening displacement(COD) in the FPZ. The proposed model can simulate the actual fracture energy of experimental results fairly well. The results of the experimental data analysis show that specimen geometry and loading condition did not affect the CCS-COD relation. However, the strain energy release rate is a function of not only specimen geometry but also crack extension. The strain energy release rate remained constantly at the minimum value up to the crack extension of 25 mm, and then it increased linearly to the maximum value. The maximum fracture criterion occurred at the peak load for specimens of large size. The fracture criterion remained at the maximum value after the peak load. The variation of the fracture criterion is caused by micro-cracking and micro-crack localization. The fracture criterion of strain energy release rate can simply be the size effect of concrete fracture, and it can be used to quantify the micro-cracking and micro-crack localizing behavior of concrete.

Seismic behavior of non-seismically designed reinforced concrete frame structure

  • Nguyen, Xuan-Huy;Nguyen, Huy Cuong
    • Earthquakes and Structures
    • /
    • 제11권2호
    • /
    • pp.281-295
    • /
    • 2016
  • This paper presents a study on a non-seismically designed reinforced concrete (RC) frame structure. The structure was a existing three-story office building constructed according to the 1990s practice in Vietnam. The 1/3 scaled down versions of structure was tested on a shake table to investigate the seismic performance of this type of construction. It was found that the inter-story drift and the overall behavior of structure meet the requirements of the actual seismic design codes. Then, nonlinear time history analyses are carried out using the fiber beam- column elements. The comparison between the experimental and simulation results shows the performance of the time history analysis models.

적산온도 기반 콘크리트의 압축강도 예측을 위한 무선 아두이노 센서 시스템 개발에 관한 기초 연구 (A Fundamental Study on Development of Arduino Wireless Sensor System for Prediction of Concrete Compressive Strength using Maturity)

  • 김한솔;문동환;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.67-68
    • /
    • 2019
  • The mechanical and durability characteristics of concrete structures depend on the construction environment, material conditions, design conditions, and temperature and humidity environment after casting. However, wired communicati-on sensors which are mainly used in the field have many limitations in their usability and monitoring. In this study, all temperature and humidity data measured from embedded sensors are monitored via a wireless sensor network. Based on the measured temperature data, the predicted compressive strength of the concrete was compared with the actual compressive strength. As a result, The error between predicted strength and experimental strength has decreased over time.

  • PDF

현장재하실험을 통한 PC지하주차장 주조물의 거동분석 (Assessments of Precast Concrete Underground Parking Garage Using Site Instrumentations)

  • 곽효경;윤정방;이형진;이석용
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.248-255
    • /
    • 1997
  • The structural behaviors under wheel loads are much different from those under uniform loads which are generally adopted for the design of parking garage. In such a viewpoint, the structural behavior of a Half-PC concrete underground parking garage under wheel loads was investigated using the site instrumentations. The static wheel loads were applied on the structure to evaluate the actual static resistance, and moving load tests were also performed to evaluate the impact factors of the structure. Besides, the impact tests were also conducted to estimate the modal parameters of the structure. Through the experimental investigations, it was found that the structural performance of the underground parking garage can be improved by use of structural type such as Half-PC concrete structures.

  • PDF

Residual capacity assessment of post-damaged RC columns exposed to high strain rate loading

  • Abedini, Masoud;Zhang, Chunwei
    • Steel and Composite Structures
    • /
    • 제45권3호
    • /
    • pp.389-408
    • /
    • 2022
  • Residual capacity is defined as the load carrying capacity of an RC column after undergoing severe damage. Evaluation of residual capacity of RC columns is necessary to avoid damage initiation in RC structures. The central aspect of the current research is to propose an empirical formula to estimate the residual capacity of RC columns after undergoing severe damage. This formula facilitates decision making of whether a replacement or a repair of the damaged column is adequate for further use. Available literature mainly focused on the simulation of explosion loads by using simplified pressure time histories to develop residual capacity of RC columns and rarely simulated the actual explosive. Therefore, there is a gap in the literature concerning general relation between blast damage of columns with different explosive loading conditions for a reliable and quick evaluation of column behavior subjected to blast loading. In this paper, the Arbitrary Lagrangian Eulerian (ALE) technique is implemented to simulate high fidelity blast pressure propagations. LS-DYNA software is utilized to solve the finite element (FE) model. The FE model is validated against the practical blast tests, and outcomes are in good agreement with test results. Multivariate linear regression (MLR) method is utilized to derive an analytical formula. The analytical formula predicts the residual capacity of RC columns as functions of structural element parameters. Based on intensive numerical simulation data, it is found that column depth, longitudinal reinforcement ratio, concrete strength and column width have significant effects on the residual axial load carrying capacity of reinforced concrete column under blast loads. Increasing column depth and longitudinal reinforcement ratio that provides better confinement to concrete are very effective in the residual capacity of RC column subjected to blast loads. Data obtained with this study can broaden the knowledge of structural response to blast and improve FE models to simulate the blast performance of concrete structures.