능동 클램프 모드로 동작하는 단일 전력 AC/DC 컨버터에 의한 역률개선 (Power Factor with Single Power Stage AC/DC Converter Operated in Active-Clamp Mode)

  • 윤신용;백수현;김용;김철진;어창진
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권8호
    • /
    • pp.392-401
    • /
    • 2001
  • This paper presents the single-stage high power factor AC to DC converter operated in active-clamp mode. The proposed converter is added active-clamping circuit to boost-flyback single-stage power factor corrected power supply. The active-clamping circuit limits voltage spikes, recycles the energy trapped in the leakage inductance, and provides a mechanism for achieving soft switching of the electronic switches to reduce the switching loss. The auxiliary switch of active-clamping circuit uses the same control and driver circuit as the main switch to reduce the additional cost and size. To verify the performance of the proposed converter, a 100W converter has been designed. The proposed converter gives good power factor correction, low line current harmonic distortions, and tight output voltage regulation, as used unity power factor.

  • PDF

높은 Q값을 갖는 저전압 능동 CMOS 인덕터 (A Low-voltage Active CMOS Inductor with High Quality Factor)

  • 유태근;홍석용;정항근
    • 대한전자공학회논문지SD
    • /
    • 제45권2호
    • /
    • pp.125-129
    • /
    • 2008
  • 본 논문에서는 Q값(Q-factor)을 증가시킬 수 있는 저전압 능동(active) CMOS 인덕터를 제안하고 설계하였다. Q값을 증가시키기 위한 방법으로 저전압 능동 CMOS 인덕터에 피드백 저항을 삽입하여 등가적인 인덕턴스와 Q값을 증가시켰다. 저전압 능동 CMOS 인덕터는 0.18um 표준 CMOS 공정으로 설계하였으며 모의실험은 애질런트사의 ADS 시뮬레이터를 이용하였다. 모의 실험결과 설계된 피드백 저항을 삽입한 저전압 능동 CMOS 인덕터는 4GHz에서 1.5nH의 인덕턴스와 최대 3000이상의 Q값을 가졌고 소비전력은 5.4mW였다.

액티브 시니어 골프참여자의 지각된 환경적요인과 주관적 건강 및 활동적 노화의 관계 (The Structural Relationship among Perceived Environmental Factor, Self-Rated Health and Active Aging for Active Senior Golf Participants)

  • 김형진
    • 한국응용과학기술학회지
    • /
    • 제38권6호
    • /
    • pp.1616-1626
    • /
    • 2021
  • 본 연구는 액티브 시니어 골프참여자를 대상으로 지각된 환경적요인과 주관적 건강 및 활동적 노화에는 어떠한 관계가 있는지 규명하는데 목적이 있다. 본 연구의 목적을 달성하기 위하여 SPSS(Statistical Package for the Social Sciences) 18.0과 AMOS(Analysis of Moment Structures) 18.0을 이용하여 빈도분석, 확인적 요인분석, 신뢰도분석과 상관관계분석을 실시하였고 모형을 설정한 뒤 구조방적식모형(Structural Equation Modeling)을 통하여 변인 간의 인과적 관계를 규명하였다. 이상과 같은 연구방법과 연구모형 검증을 기초로 하여 본 연구에서 도출된 결과는 다음과 같다. 첫째, 지각된 환경적요인은 활동적 노화에 정적인 영향을 미치는 것으로 나타났다. 둘째, 활동적 노화는 주관적 건강에 정적인 영향을 미치는 것으로 나타났다. 셋째, 지각된 환경적요인은 주관적 건강에 정적인 영향을 미치는 것으로 나타났다. 넷째, 지각된 환경적요인과 주관적 건강의 관계에서 활동적 노화는 매개하는 것으로 나타났다.

직.병렬 능동 전력필터 시스템을 이용한 불평형 전원전압 보상 (The Compensating Unbalanced Source Voltages for Unified Active Power Filter System)

  • 김영석;강민형
    • 전기학회논문지
    • /
    • 제56권4호
    • /
    • pp.716-723
    • /
    • 2007
  • This paper suggests of a 3-phase 3-wire unified active power filter. The system is composed of a series active power filter and a parallel active power filter. The proposed series active power filter compensating unbalance source voltage and current harmonics of the parallel active power filter improves power factor. The proposed algorithm which improves for power factor and harmonic reduction are calculated by the performance function, and which compensates for the unbalanced source voltage is calculated based on the symmetrical component analysis. We composed a combined system of the series active power filter and parallel active power filter to confirm a validity of the proposed control methods. The effectiveness of the proposed algorithm is confirmed by the experiments.

싸이리스터 정류부하를 위한 새로운 저원가 복합형 전력필터 (A New Low Cost Hybrid Power Filter for Thyristor-Controlled Rectifier Load)

  • 한성룡;김수근;석원엽;조정구;송의호;전희종
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권1호
    • /
    • pp.24-29
    • /
    • 2004
  • A new low cost hybrid active filter for thyristor-controlled rectifier load is presented to overcome the high cost problem of the active or the other hybrid active filters. The proposed hybrid active filter which consists of tuned (5th and 7th harmonics) LC passive filters, power factor improvement(PFI) capacitor bank, and active filter compensates power factor as well as harmonic currents. Since most of harmonic currents are filtered by the passive filter and most of reactive power is compensated by the PFI capacitor bank, the power rating of active filter can be minimized, resulting in cost minimization of the proposed hybrid active filter. A 300kVA hybrid active filter system is implemented and tested using 1MVA thyristor rectifier load to verify the operation and performance.

Bidirectional Dual Active Half-Bridge Converter Integrated High Power Factor Correction

  • Ngo, AnhTuan;Nam, Kwanghee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.444-446
    • /
    • 2011
  • A bidirectional dual active converter with the power factor control capability is proposed as a battery charger. The source side half-bridge acts as a PWM converter that maintains the unity power factor. The battery side half-bridge converter acts as a dual active bridge (DAB) together shares the same DC link voltage with PWM converter. The imbalance voltage phenomenon is eliminated by employing asymmetric duty cycle technique. Simulation results are included to verify theoretical analysis.

  • PDF

전원 불평형과 역률을 보상하는 직렬형 능동전력필터의 통합적 제어 (Integrative Control of Series Active Power Filters for Source Voltage Unbalance Compensation and Power Factor Correction)

  • 장정익;석줄기;이동춘
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권5호
    • /
    • pp.258-264
    • /
    • 2006
  • This paper presents an integrative control scheme for series-type active power filters combined with shunt passive filters not only to compensate for the source voltage unbalance and current harmonics but also to correct the power factor. To reduce the power capacity of the active filters, passive filters are connected in parallel. Diode rectifiers are replaced by the PWM converters in order to feed the real power back to the source. Power factor control is performed by changing the phase of the load voltage so that the phase of the source current coincides with that of the source voltage. The resultant voltage reference is the addition of the voltage component compensating for the source voltage unbalance and harmonic currents and the voltage component correcting the power factor. The validity of the proposed algorithm has been verified by experimental results.

고조파 필터 및 인버터의 용량을 고려한 분산전원 시스템의 역률 제어에 관한 연구 (A Study on Power Factor Control of Inverter-based DG System with Considering the Capacity of an Active Harmonic Filter and an Inverter)

  • 김영진;황평익;문승일
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2149-2154
    • /
    • 2009
  • Electric power quality in power transmission/distribution systems has considerably been deteriorated with the increase in the capacity of distributed generators (DGs). It is because inverters, connecting DGs to conventional power grids, tend to generate harmonic current and voltage. For harmonic mitigation, a large amount of research has been done on passive and active filters, which have been operating successfully in many countries. This paper, therefore, presents how to adopt the filters to an inverter-based DG, with considering a system consisting of both inverter-based DG and harmonic filters. In particular, this paper describes the simulation results using the PSCAD/EMTDC: firstly, the relationship between total harmonic distortion(THD) of current and output power of DG: secondly, the harmonic mitigation ability of passive and active filters. The system, furthermore, is obliged to satisfy the regulations made by Korean Electric Power Corporation(KEPCO). In the regulations, power factor should be maintained between 0.9 and 1 in a grid-connected mode. Thus, this paper suggests two methods for the system to control its power factor. First, the inverter of DG should control power factor rather than an active filter because it brings dramatic decrease in the capacity of the active filter. Second, DG should absorb reactive power only in the range of low output power in order to prevent useless capacity increase of the inverter. This method is expected to result in the variable power factor of the system according to its output power.

건설업의 산업재해 사고사망자 감소 영향요인 분석 - 경제적 요인 및 노동력 요인을 중심으로 - (Analysis on Reduction Effect Factors of Occupational Accident Fatalities in Construction Industry - Focusing on Economic and Workforce Factors -)

  • 송병춘;원정훈
    • 한국안전학회지
    • /
    • 제35권2호
    • /
    • pp.55-60
    • /
    • 2020
  • The purpose of this study is to analyze the influence of the economic and workforce factors on the annual number of occupational accident fatalities occurring at the construction sites. The considered variables of the economic factor are the amount of economic losses caused by industrial accidents, the GDP, and the total monthly wage for each economically active population. And, the variables related to the workforce factor are the number of economically active population, the number of female economically active population, and the number of labor union members. The multiple regression analysis was conducted to determine the effect of two factors on the total number of occupational fatalities in the construction industry. The results show that GDP among considered variables in the economic factor had a statistically significant negative relationship with the number of the construction accident fatalities in the construction industry. Among variables related to the workforce factor, economically active population showed a statistically significant negative relationship with the number of the construction accident fatalities.

단상 AC/DC PWM 변환기의 단위 역률 제어 (Unity Power Factor Control for A Single Phase AC/DC PWM Converter)

  • 강동우;차영길;이득기;김흥근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.373-377
    • /
    • 1996
  • Recently, active power factor control for AC/DC converter has been required to replace for a conventional diode rectifier. A voltage type AC/DC converter is widely used to obtain higher regulated DC voltage than input voltage with a unity power factor and a sinusoidal line current. This paper describes several active power factor control method for AC/DC converter. The analysis of several active power factor control is given. The simulations for hysteresis control, peak current control. constant frequency control and average current mode control are represented and compared.

  • PDF