• Title/Summary/Keyword: active contamination

Search Result 86, Processing Time 0.027 seconds

Study of point defects caused by a thin contamination layer in a-Si TFT-LCD

  • Oh, Jae-Young;Lee, Jae-Kyun;Yang, Moung-Su;Kang, In-Byeong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.845-848
    • /
    • 2007
  • Analysis of point defects invisible by a microscope has been studied on the a-Si thin film transistor panel. The point defects which were named Invisible Point Defect (IPD) is characterized by no particles or distortion of patterns on a pixel structure and randomly distributed on panels. To investigate the IPD, measurements were carried out: gray level driving, transistor transfer characteristic, focused ion beam (FIB), and secondary ion mass spectrometry (SIMS). The results showed that a contamination layer had a bad influence on an active surface. The contamination layer consisted of oxygen and iron from a water supply line during cleaning process. After the process tuning, IPD has been stabilized.

  • PDF

Design and Implementation of a Robust Predictive Control Scheme for Active Power Filters

  • Han, Yang;Xu, Lin
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.751-758
    • /
    • 2011
  • This paper presents an effective robust predictive control scheme for the active power filter (APF) using a smith-predictor based current regulator, which show superior features when compared to proportional-integral (PI) controllers in terms of an enhanced closed-loop bandwidth and an improved current tracking accuracy. A moving average filter (MAF) is implemented using a field programmable gate array (FPGA) for signal pre-processing to eliminate the switching ripple contamination. An adaptive linear neural network (ADALINE) is used for individual harmonic estimation to achieve selective compensation purpose. The effectiveness and validity of the devised control algorithm are confirmed by extensive simulation and experimental results.

Study of Radiation Mapping System for Water Contamination in Water System (방사능 수치 오염 지도 작성을 위한 방사선 계측 시스템 연구)

  • Na, Teresa W.;Kim, Han Soo;Yeon, Jei Won;Lee, Rena;Ha, Jang Ho
    • Journal of Radiation Industry
    • /
    • v.5 no.2
    • /
    • pp.185-189
    • /
    • 2011
  • As nuclear industry has been developed, a various types of radiological contamination has occurred. After 9.11 terror in U.S.A., it has been concerned that terrorists' active area has been enlarged to use nuclear or radioactive substance. Recently, the most powerful earth-quake stroke, which triggered a massive tsunami in Japan and then Fukushima nuclear power plant reactor has suffered from a serious accident in history. The Fukushima reactor accident has occurred an anxiety of radiation leaks and about 170,000 people have been evacuated from the accidental area near the nuclear power plant. For these reasons, a social chaos can be occurred if radiological contamination occurs to the supply system for the drinking water. As such, the establishment of the radiation monitoring system for the city main water system is compelling for the national security. In this study, a feasibility test of radiation monitoring system which consists of unified hybrid-type radiation detectors was experimented for multi detection system by using gamma-ray imaging. The hybrid-type radiation sensors were fabricated with CsI(Tl) scintillators and photodiodes. A preamplifier and amplifier was also fabricated and assembled with the sensor in the shielding case. For the preliminary test of detection of radiological contamination in the river, multi CsI(Tl)-PIN photodiode radiation detectors and $^{137}Cs$ gamma-ray source were used. The DAQ was done by Linux based ROOT program and NI DAQ system with Labview program. The simulated contamination was assumed to be occurred at Gapcheon river in Daejeon city. Multi CsI(Tl)-PIN photodiode radiation detectors were positioned at the Gapcheon river side. Assuming that the radiological contaminations flows in the river the $^{137}Cs$ gamma-ray source has been moved and then, the contamination region was reconstructed.

Clinical Characteristics Associated with Blood Culture Contamination in Neonates (신생아에서 혈액 배양 오염과 관련된 임상적 특징)

  • Jung, Min Young;Son, Ok Sung;Hong, Yoo Rha;Oh, Chi Eun
    • Pediatric Infection and Vaccine
    • /
    • v.22 no.3
    • /
    • pp.147-153
    • /
    • 2015
  • Purpose: This study was aimed to investigate the contamination rates of blood culture in a neonatal intensive care unit (NICU) and to examine the clinical characteristics related to the contamination. Methods: Eight hundred thirty cases of blood culture performed from March 2013 to February 2014 were analyzed. We evaluated the contamination rates of blood culture by blood sampling sites and compared the clinical characteristics such as real name system and body weights of the contaminated cases and those of non-contaminated ones. The clinical characteristics were retrospectively reviewed by medical records. Results: The overall contamination rate was 3.6% (30/830). The contamination rates by blood sampling sites were as follows: peripheral vein 15.6% (10/64), peripheral artery 2.6% (20/759), and umbilical arterial catheter 0% (0/7). There was no difference in the contamination rates between cases with and without real name system (P=0.484). However, there were significant differences in the contamination rates by the physicians who performed the culture (P=0.038) and body weight (<1,000 g vs. ${\geq}1,000g$) at the time of blood culture (P<0.001). Conclusions: These results suggest that neonates with a body weight less than 1,000 g have more risks of the contamination of blood culture. Furthermore, there is a necessity to provide blood culture performers with active feedbacks and individualized education plans that can help diminish blood culture contamination rates. Prospective studies in a systematic manner that can be applied in actual clinical settings are needed in order to figure out factors that can diminish the contamination rates of blood culture in NICU.

Decrease of PEMFC Performance by Toluene in Air (공기 중 톨루엔에 의한 고분자전해질연료전지의 성능감소)

  • Lee, Ho;Song, Jin-Hoon;Kim, Ki-Joong;Kim, Sae-Hoon;Ahn, Byung-Ki;Lim, Tae-Won;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.49 no.1
    • /
    • pp.15-20
    • /
    • 2011
  • The contamination effect of toluene in the airstream on PEM fuel cell performance was studied with various toluene concentration under different operation conditions. And the recovery of the cell performance by applying clean air and the removal of toluene in the air by adsorption of active carbon were investigated. The toluene concentration range used in the experiments was from 0.1 ppm to 5.0 ppm. The performance degradation and recovery were measured by constant-current discharging and electrochemical impedance spectroscopy(EIS). Toluene adsorption capacity of KOH impregnated active carbon was obtained from the adsorption isotherm curve. The severity of the contamination increased with increasing toluene concentration, current density and air stoichiometry, but decrease with increasing relative humidity. The cell performance was recovered by toluene oxidation with oxygen and water in humidified neat air. EIS showed that the increase of charge transfer resistance due to toluene adsorption on Pt surface mainly reduced the performance of PEMFC. Toluene adsorption capacity of active carbon decreased as KOH weight increased in KOH impregnated active carbon.

Cleaning Validation Studies for Multi-Purpose Facility : Vial Filling Machine (다품목 공용 제약설비인 바이알 충전기에 대한 세척공정 밸리데이션)

  • Choi, Han-Gon;Yang, Ho-Joon;Kim, Young-Ran;Sung, Jun-Ho;Hwang, Ma-Ro;Kim, Jong-Oh;Yong, Chul-Soon
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.4
    • /
    • pp.263-267
    • /
    • 2009
  • The purpose of this study is to evaluate the efficacy of stipulated cleaning process, and the prohibition of cross-contamination and microbiological contamination, which inadequate cleaning in multi-production could occur, through cleaning validation of multi-purpose facility used to produce five biopharmaceutical products as sterile injection. After production of five biopharmaceutical products such as hGH, rhGCSF, rhEPO, rhFSH and rhIFN using vial filling machine, the cleaning validation such as residual analysis of active ingredients or human serum albumin, measurement of total organic carbon (TOC), residual analysis of detergent and microbiological contamination were carried out. In the case of rhGH and rhGCSF clean validations, drug residues were not detected. Furthermore, in the case of rhEPO, rhFSH and rhIFN clean validations, human serum albumin residues were not detected. At TOC (total organic carbon) analysis, all clean validations gave the TOC of about average 137.93%, not more than 150% of acceptance criteria. At sodium analysis for the checking of residues of cleaning agent, sodium residues were not detected. In sterility test, they showed no microbiological contamination of bacteria and fungi. Thus, this cleaning validation was determined as successful in protection of cross-contamination and induction of safety in multi-purpose facility.

Using response surface methodology and Box-Behnken design in the study of affecting factors on the dairy wastewater treatment by MEUF

  • Khosroyar, Susan;Arastehnodeh, Ali
    • Membrane and Water Treatment
    • /
    • v.9 no.5
    • /
    • pp.335-342
    • /
    • 2018
  • Micelle-Enhanced Ultrafiltration (MEUF) is a membrane separation processes that improving ultrafiltration process with the formation of micelles of the surface active agents. Surface active agents are widely used to improve membrane processes due to the ability to trap organic compounds and metals in the treatment of industrial waste water. In this study, surface active agents are used to improve micelle-enhanced ultrafiltration (MEUF) to reduce chemical oxygen demand (COD), total dissolved solid (TDS), turbidity and clogging the membrane in dairy wastewater treatment. Three important operational factors (anionic surface active agent concentration, pressure and pH) and these interactions were investigated by using response surface methodology (RSM) and Box-Behnken design. Results show that due to the concentration polarization layer and increase the number of Micelles; the anionic surface active agent concentration has a negative effect on the flux and has a positive effect on the elimination of contamination indices. pH, and the pressure have the greatest effect on flux. On the other hand, it could be stated that these percentages of separation are in the percentages range of Nano-filtration (NF). While MEUF process has higher flux than NF process. The results have been achieved at lower pressure while NF process needs high pressure, thus making MEUF is the replacement for the NF process.

A Feasibility Study for Decision-Making Support of a Radioactive Contamination Model in an Urban Environment (METRO-K) (도시환경 방사능오염 평가모델 METRO-K의 대응행위 결정지원을 위한 실용성 연구)

  • Hwang, Won-Tae;Han, Moon-Hee;Jeong, Hyo-Joon;Kim, Eun-Han;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.27-34
    • /
    • 2008
  • A Korean urban contamination model METRO-K (${\underline{M}}odel$ for ${\underline{E}}stimates$ the ${\underline{T}}ransient$ Behavior of ${\underline{R}}adi{\underline{O}}active$ Materials in the ${\underline{K}}orean$ Urban Environment, which is capable of calculating the exposure doses resulting from radioactive contamination in an urban environment, is taking part in a model testing program EMRAS (${\underline{E}}nvironmental$ ${\underline{M}}odelling$ for ${\underline{RA}}diation$ ${\underline{S}}afety$) oragnized by the IAEA (${\underline{I}}nternational$ ${\underline{A}}tomic$ ${\underline{E}}nergy$ ${\underline{A}}gency$). For radioactive contamination scenarios of Pripyat districts and a hypothetical RDD (${\underline{R}}adiological$ ${\underline{D}}ispersal$ ${\underline{D}}evice$), the predicted results using METRO-K were submitted to the EMRAS's Urban Contamination Working Group. In this paper, the predicted results for the contamination scenarios of a Pripyat district were shown in case of both without remediation measures and with ones. Comparing with the predictied results of the models that have taken part in EMRAS program, a feasibility for decision-making support of METRO-K was investigated. As a predicted result of METRO-K, to take immediately remediation measures following a radioactive contamination, if possible, might be one of the best ways to reduce exposure dose. It was found that the discrepancies of predicted results among the models are resulted from 1) modeling approaches and applied parameter values, 2) exposure pathways which are considered in models, 3) assumptions of assessor such as contamination surfaces which might affect to an exposure receptor and their sizes, 4) parameter values which are related with remediation measures applied through literature survey. It was indentified that a Korean urban contamination model METRO-K is a useful tool for dicision-making support through the participation of EMRAS program.

Persistent Organic Pollution and Arsenic Contamination in Asia Pacific Water: Case Study of Emerging Environmental Problems in Vietnam

  • Pham, Viet.H.
    • Journal of Wetlands Research
    • /
    • v.9 no.1
    • /
    • pp.79-89
    • /
    • 2007
  • This paper provides a comprehensive overview of the present status of several environmental problems caused by emerging toxic substances such as persistent organic pollutants (POPs), endocrine disrupting chemicals (EDCs), and arsenic in various environmental media in Vietnam. Monitoring data reported during the 1990s demonstrated elevated contamination of DDTs in most of these compartments in Vietnam. Studies in frame of the Asia-Pacific Mussel Watch Program revealed that fish, mussels and resident birds from Vietnam contained higher concentrations of DDTs as compared to other countries in region, suggesting the role of Vietnamese environment as a significant emission source of DDT in the Southeast Asian region. The estimated dietary intakes of PCBs and DDTs for Vietnamese were relatively high among Asian developing countries, suggesting potential risk for humans posed by thesechemicals. Widespread contamination of some endocrine active compounds such as alkylphenols and phthalates was observed at various sites along the coasts of northern and middle Vietnam. The presence of significant source of bisphenol-A along Red River estuary was revealed with the concentrations comparable to those reported for developed nations. A case study on seasonal variation of alkylphenols and phthalates in surface water of river delta and estuary of north and middle Vietnam indicated the differences in distribution of these compounds between dry and rainy seasons. Higher concentrations of alkylphenols and phthalates were found in dry season in estuary; while the contrasting pattern was observed in the river delta, showing elevated residues in rainy season. This result suggests the different behavior of alkylphenols and phthalates in river delta and coastal environment. From ecotoxicological perspectives, concentrations of bis-phenol A and di(2-ethylhexyl)phthalates [DEHP] in surface water from some locations in Vietnam exceeded the guideline values for Ecotoxicological Effects and the Environmental Risk Limit, respectively, suggesting potential for toxic implications on aquatic wildlife. Widespread and elevated arsenic contamination was discovered inour recent surveys in groundwater in a large area of suburban areas of Hanoi city, the capital of Vietnam. The most recent investigation in 4 villages showed about more than 50 % of groundwater samples contained As concentrations exceeding 50 g/L (the WHO and Vietnamese standard). In particular, in Son Dong villages, 58 % of samples analyzed contained As concentrations higher than 200 g/L. Good correlations were found in As concentrations in water and hair and urine of peoples in corresponding families, suggesting the chronic exposure to As by people living in As-contaminated ground water areas. In Son Dong village, As levels in hair (mean: 1.7 mg/kg dry wt) and urine (g/g creatinine) exceeding the reference values recommended by WHO, suggesting potential for human risk posed by long term accumulation of As in human body. Future studies should be focused on the time trends of POPs and EDCs in biota in Vietnam in order to predict future trend of contamination and to reveal new clues for understanding possible toxic impacts on aquatic organisms. The issues of arsenic contamination in groundwater and their chronic toxic implications on human health should be systematically investigated in the future.

  • PDF

A Study on Welding Performance Improvement of $CO_2$ Inverter Arc Welding Machine by Arc Reignition Detection (아크 재생 검출에 의한 $CO_2$ 인버터 아크 용접기의 용접성능향상에 관한연구)

  • 이정락
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.581-586
    • /
    • 2000
  • Gas metal arc welding(GMAW) uses a continuously fed electrode as a filler metal. The arc is shielded from atmospheric contamination by an inert gas active or inert/active gas mixture delivered through the welding gun and cable assembly. The recent research topics on $CO_2$ are welding machines are focused mainly on the reduction method of generated spatter by using new type consumable electrode metal or inverter control method. The various current waveform control methods have been researched for welding performance improvement. Until now current waveform control methods reduce to spatter occurred by instantaneous short circuiting,. but these methods is drawback that no reduce spatter occurred by arc reignition. In this paper the previous arc reignition current control method for welding performance improvement of inverter arc welding machine is studied and compared the various current control methods with the previous arc reignition current control method.

  • PDF