• Title/Summary/Keyword: activation analysis

Search Result 3,571, Processing Time 0.041 seconds

Experimental Investigation on the Flow Characteristics of ER Fluids II (2nd Report, Viscosity-Temperature Characteristics of Dispersive ER Fluids) (ER 유체의 유동특성에 관한 실험적 연구 II (분산계 ER 유체의 점도-온도 특성))

  • 김도태
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.393-398
    • /
    • 1999
  • The temperature dependence of the viscosity was determined for an electrorheological(ER) fluid consisting of 35 weight% zeolite particles in hydraulic oil 46cSt. Thermal activation analysis were performed by changing the ER fluid's temperature from -1$0^{\circ}C$ to 5$0^{\circ}C$ at fixed electric field. According to the analysis, the activation energy for flow was about 79.64kJ/mole at E=0kV/mm. Generally, the hydraulic oil 46cSt will be operated at the temperature of about 4$0^{\circ}C$, the ER fluid's electric field dependence of viscosities were investigated at this temperature. also, the influence of adding the dispersant(Carbopl 940) on electrorheological effect of the ER fluid was discussed.

  • PDF

A quantitative approach for reliability growth of electronics units (전자장비 신뢰도 향상을 위한 정량적 접근 연구)

  • Kim, Joo-Nyun;Kim, Bo-Gwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.3
    • /
    • pp.268-274
    • /
    • 2007
  • In general, rocket or satellite circuit designers focus on reducing temperature of electronic devices in order to enhance electronic unit's reliability. This paper describes the quantitative analysis result of activation energy as well as device temperature effects to the system reliabilities. The quantitative analysis result shows that activation energy of device has more effects on system reliability than temperature does. And this paper suggests a strategy for enhancement of reliability during devices placement on PCB with simulation results.

The Design of 128 Channels Cardiac-Activation Pre-Amplifier (128 채널 심장전기도 전치 증폭기의 설계)

  • Yoo, Sun-Kook;Chang, Byung-Chul;Jung, Dong-Il;Han, Young-Oh
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.11
    • /
    • pp.550-556
    • /
    • 2001
  • The computerized cardiac analysis system, which acquires and analyzes the electrical activation signal propagating along the surface of the heart, is indispensible equipment for the open heart surgery and electrical cardiac study. In this paper, the design requirement and the electrical circuit analysis are performed to construct the multi-channel cardiac activation pre-amplifier necessary for a signal conditioning circuit. The general 64 channel configuration is expanded into 128 channels to enhance the spatial resolution on the mapped surface of the heart. The 128 channels pre-amplifier consists of input circuit, differential amplifier, right leg driven circuit and isolation part. It has distinct features; high voltage protection, leakage current limitation, isolation and the maximization of common mode rejection ratio with respect to the half-cell potential difference due to different electrode materials. The final pre-amplifier circuit is assembled with 8 boards, each of which composing of 16 channels.

  • PDF

The imaging of 128 channels cardiac activation signal (128채널 심장전기도 신호의 영상화)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.2
    • /
    • pp.133-137
    • /
    • 2010
  • In this study, The imaging of 128 channels cardiac activation signal is implemented. It is performed within one minutes and very useful in open-heart operation with analysis in a short time. Especially the keeping of data and the moving of system is facility because it was implemented with being based on PC. The cardiologist can call data and analysis them anytime after a surgery.

Electroencephalogram Analysis on Learning Factors during Relaxed or Concentrated Attention according to the Color Temperatures of LED Illuminance (이완집중 및 긴장집중 시 LED 조명의 색온도에 따른 학습요인의 뇌파분석)

  • Jee, Soon-Duk;Kim, Chae-Bogk
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.21 no.6
    • /
    • pp.33-42
    • /
    • 2014
  • The objective of this study is to investigate learning factors (stability, attention and activation) in school by electroencephalogram (theta, alpha and beta waves) analysis during relaxed or concentrated. In order to measure electroencephalograms, MP 150 by Biopac and ECI Electro-Cap are employed. Three types of color temperatures (3000K, 5000K, 7000K) are used and 13 undergraduate and 12 graduate students are selected as experimental subjects. When subjects are relaxed during contemplation or concentrated during mental arithmetic, we compare with stability, attention and activation indices. The test results show that subjects were stable when color temperature is 5000K. Subjects gave best attention when color temperature is 7000K. Subjects activated well when color temperature is 3000K during relaxed attention. However, subjects activated rigorous when color temperature is 7000K during constrained attention.

Measuring health activation among foreign students in South Korea: initial evaluation of the feasibility, dimensionality, and reliability of the Consumer Health Activation Index (CHAI)

  • Park, MJ;Jung, Hun Sik
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.192-197
    • /
    • 2020
  • Foreign students in South Korea face important challenges when they try to maintain their health. As a measure of their motivation to actively build skills for overcoming those challenges, we evaluated the 10-item Consumer Health Activation Index (CHAI), testing its feasibility, dimensionality, and reliability. There were no missing data, there was no floor effect, and for the total scores the ceiling effect was trivial (< 2%). Results of the Kaiser-Meyer-Olkin test and Bartlett's test of sphericity indicated that the data were suitable for the detection of structure by factor analysis. The results of parallel analysis and the shape of the scree plot supported a two-factor solution. One factor had 3 items concerning "my doctor" and the other factor had the 7 remaining items. Reliability was high for the 10-item CHAI (alpha = 0.856), for the 3-item subscale (alpha = 0.838), and for the 7-item subscale (alpha = 0.857). Reliability could not be improved by deletion of any items. Use of the CHAI to gather data from these foreign students is feasible, and reliable results can be obtained whether one uses the total score from all 10 items or scores from the proposed 7-item and 3-item subscales.

Effect of Lycii cortex radicis Extraction on Glioma Cell Viability

  • Kim, Seang-Jae;Jeong, Ji-Cheon
    • The Journal of Korean Medicine
    • /
    • v.30 no.6
    • /
    • pp.17-26
    • /
    • 2009
  • Objectives: Little information is available regarding the effect of Lycii cortex radicis (LCR) on cell viability in glioma cells. This study was therefore undertaken to examine the effect of LCR on cell survival in U87MG human glioma cells. Methods: Cell viability and cell death were estimated by MTT assay and trypan blue exclusion assay, respectively. Reactive oxygen species (ROS) generation was measured using the fluorescence probe DCFH-DA. Activation of Akt and extracellular signal-regulated kinase (ERK) and activation of caspase-3 were estimated by Western blot analysis. Results: LCR resulted in apoptotic cell death in a dose- and time-dependent manner. LCR increased reactive oxygen species (ROS) generation and LCR-induced cell death was also prevented by antioxidants, suggesting that ROS generation played a critical role in LCR-induced cell death. Western blot analysis showed that LCR treatment caused down-regulation of Akt and ERK. The LCR-induced cell death was increased by the inhibitors of Akt and ERK. Activation of caspase-3 was stimulated by LCR and caspase inhibitors prevented the LCR-induced cell death. Conclusion: These findings suggest that LCR results in human glioma cell death through a mechanism involving ROS generation, down-regulation of Akt and ERK, and caspase activation.

  • PDF

Characteristics of Pore Development for Activated Carbon Fiber from Polyacrylonitrile(II) -Activation- (PAN계 활성탄소 섬유의 세공발달 특성(II) -활성화-)

  • Park, Jong-Hak;Cho, Byung-Rin
    • Applied Chemistry for Engineering
    • /
    • v.4 no.1
    • /
    • pp.113-124
    • /
    • 1993
  • Thermogravimetric analysis of copolymer of acrylonitrile(95%) and methyl acrylate(5%) have been carried out to investigate the activation under $H_2O$(30%) -$N_2$atmosphere at various heating rates. The kinetic equation [$f=1-\exp(-a{\Delta}T)^b$] which was derived on the basis of the nonisothermal activation process of carbon fiber in the $H_2O$(30%)-$N_2$system showed good agreement with experimetal results. The pore volume upon conversion was in good agreement with the model of theoretical pore volume. The pore structures of the activated carbon fiber were influenced by the heating rate, activation temperature and internal-external conversions.

  • PDF

Correlation between Trunk Stabilization Muscle Activation and Gait Parameters (몸통 안정화 근육과 보행요소의 상관관계)

  • Chae, Jung-Byung;Jung, Ju-Hyeon
    • PNF and Movement
    • /
    • v.17 no.1
    • /
    • pp.111-118
    • /
    • 2019
  • Purpose: This study aimed to investigate the correlation between trunk stabilization muscle activation and the parameters of gait analysis in healthy individuals. Methods: Thirty healthy adults (15 male, 15 female) with no history of lower back pain (LBP) or current musculoskeletal and neurological injuries were studied. Trunk stabilization muscle activation (e.g., external oblique, internal oblique, transverse abdominis, erector spinae) were assessed using surface electromyography. To analyze gait, we measured temporal parameters (e.g., gait velocity, single support phase, double support phase, swing phase, and stance phase) and a spatial parameter (e.g., H-H base of support). Results: A statistically significant correlation was found between the internal oblique, transverse abdominis, and erector spinae muscle activity and gait velocity, single support phase, double support phase, swing phase, and stance phase. No statistically significant correlation was found between the external oblique muscle activity and the gait velocity, single support phase, double support phase, swing phase, and stance phase. No statistically significant correlation was found between the external oblique, internal oblique, transverse abdominis, and erector spinae muscle activity and the spatial parameter. Conclusion: This study demonstrated that a relationship exists between trunk stabilization muscle activation and temporal parameter (i.e., gait velocity, single support phase, double support phase, swing phase, and stance phase) during gait analysis. Therefore, the trunk's stabilizer muscles play an important role in the gait of healthy individuals.

Comparison Study of Thermal Decomposition Characteristics of Wattle & Pine Tannin-based Adhesives

  • Kim, Sumin;Lee, Young-kyu;Kim, Hyun-Joong;Eom, Young Geun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.34-41
    • /
    • 2002
  • This study investigated the thermogravimetric analysis of two types of cured tannin-based adhesives from wattle and pine, with three hardeners of paraformaldehyde, hexamethylenetetramine and TN (tris(hydroxyl)nitromethan), at a temperature of 170℃ and a heating rate of 5, 10, 20 and 40℃/min for 10 minutes. The 5 minutes cured wattle tannin-based adhesive with each hardener at 170℃ was also tested to compare the degree of curing. It was found that thermogravimetric analysis could be used to measure the degree of curing of a thermosetting adhesive. The TG-DTG curves of all the adhesive systems were similar and showed three steps in a similar way to a phenolic resin. This means that each adhesive system is well cross-linked. However, a high thermal decomposition rate was shown at 150 to 400℃ in the case of the pine tannin sample with TN (tris(hydroxyl)nitromethan). The Flynn & Wall expression was used to evaluate the activation energy for thermal decomposition. As the level of conversion (𝛼) increased, the activation energy of each system increased. The activation energy of the wattle tannin-based adhesive with paraformaldehyde was higher than the others.