• Title/Summary/Keyword: acrylic splint

Search Result 13, Processing Time 0.023 seconds

A Fully Digital Auricular Splint Workflow for Post-Keloid Excision

  • Rahmat Maria;Yee Onn Kok;Khim Hean Teoh
    • Archives of Plastic Surgery
    • /
    • v.50 no.6
    • /
    • pp.563-567
    • /
    • 2023
  • Ear keloids are challenging lesions to treat due to high recurrence rates postexcision. Conservative compression techniques as adjunct treatment have been reported to be effective. An innovative technique of using computer-aided design/computed-aided manufacturing to print a customized auricular splint improves efficiency and comfort level for patients compared with conventional methods. The ear is scanned using an intraoral scanning 2 weeks postsurgery. A two-piece auricular splint is designed on the digital model, incorporating perforated projections for three nylon screws for retention of the splint. The splint is printed with clear acrylic material, postprocessed, and finished. The patient is taught to assemble the components of the splint and instructed to wear for at least 8 hours daily. The surgery site reviewed for any ulceration, pain, or recurrence of keloid for 6 months. During the 6-month review, the excision scar remained flat and pink. The patient also reports unrestricted daily activities. The digital workflow increases comfort for the patient and reduces the number of hours required to produce a customized auricular splint compared with conventional methods. A fully digital workflow for a printed auricular splint should be considered for adjunctive treatment to excision of ear keloids.

The angulation and the position change of the planned implant after tomographic imaging (단층촬영상에서 계획된 임플랜트 매식 각도 및 위치에 대한 스텐트 핀의 상대적 각도 및 위치에 대한 평가)

  • Kang, Byung-Cheol
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.127-131
    • /
    • 2007
  • Purpose: To measure the differences of the splint pin angulation and the position of the planned implant site after conventional tomographic analysis. Materials and Methods: The angulation and the location of the metal splint pin retained in acrylic stent were compared with the corrected angulation and the location of the implant fixture on the 331 tomographic images. Results: The stent pins were located buccal in 40%, lingual in 10% to the corrected implant site after analysis of the conventional tomographic image. The angle and the location of the maxillary splint pin were mainly directed buccal on incisor and canine regions. The angle and the location of the splint pins in premolar and molar regions needed less corrections in both maxilla and mandible. Conclusions: This study demonstrated that the use of tomographs was essential for successful dental implant planning.

  • PDF

Computer-assisted Virtual Surgery and Splint Fabrication for Paediatric Mandible Fracture

  • Lee, Jung-woo
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.2
    • /
    • pp.87-89
    • /
    • 2015
  • Closed reduction using acrylic splints with circummandibular fixation has been known to be useful techniques in pediatric mandibular fractures. However, this technique has some shortcomings, including needs for impression taking or additional laboratory process, which can increase the exposure time of general anesthesia or make an additional sedation visit. Recently, the advancement of computer-aided maxillofacial surgery offers to clinicians to expansion of its application. This case report represents a technique of computer-assisted virtual reconstruction and computer-aided designed splint fabrication in a 2-year-old boy with mandibular body fracture.

IMMOBILIZATION OF LOWER MANDIBULAR ALVEOLAR BONE FRACTURE USING RESIN-WIRE OPEN CAP SPLINT (하악 유전치부 치조골 골절시 resin-wire open cap splint를 이용한 고정)

  • Kwon, Joung-Hyun;Choi, Byung-Jai;Choi, Hyung-Jun;Kim, Seong-Oh;Son, Heung-Kyu;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.175-180
    • /
    • 2008
  • Traumatic injuries to the primary dentition are commonly encountered problems in dental practice. It is found that 30% of the children had injuries to the primary dentition and 22% to the permanent dentition. The greatest incidence of trauma to the primary dentition occurs at the ages of 2 and 3 as children start to learn motor coordination. Because teeth and alveolar bone are traumatized simultaneously, alveolar bone fractures are likely to occur when multiple teeth are involved in injuries. Dental splints are indicated for the management of maxillofacial fractures. They enable anatomic reduction of fractured segments and help immobilization and maintenance of the fragments after reduction. They also act as a stabilizer during rehabilitation. Various types of dental splints are available. In this case, routine resin-wire splint technique could not be applied because of the child's uncooperative behavior. Oral sedation was not indicated because N.P.O. had not been preceded. Therefore, we decided to use open-cap acrylic splint instead. Stabilization using open cap acrylic splint requires minimum chair time with reduced discomfort to both patient and dentist. It is an effective means of splint for uncooperative children and especially useful when other means of fixation have been failed. Because trauma on the primary dentition can affect the underlying permanent tooth germ, it is important to monitor eruption process of the permanent dentition.

  • PDF

Comparative accuracy of implant impression techniques with different splinting materials (임플란트 인상채득 방법과 인상용 코핑 연결 고정에 따른 정확성 비교)

  • Ki-Yoon Hong;Soo-Yeon Shin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.1
    • /
    • pp.9-20
    • /
    • 2023
  • Purpose: We investigated the effect of open tray impression using pick-up impression coping and close tray impression using transfer impression coping on the accuracy of impression in edentulous patients on their mandibular parts. the effect of material types of pick-up type impression copings for splinting in open tray impression on the accuracy of impression was also evaluated. Materials and Methods: Two implant fixtures were implanted in parallel in the left molar of the mandibular in the shape of a mandibular partial edentulous model. The 40 individual trays were fabricated using 3D printer. The prepared individual trays were classified into 4 groups (i.e., PN, PG, PH, and TN groups), and a total of 40 impression-takings were conducted. A master cast was connected to a Scan Body. The converted STL file was super-imposed on the scan images of the various groups. Results: The order of standard deviation values decreased as follows: PN (0.2343 ± 0.0844 mm), TN (0.2192 ± 0.0840 mm), indicating that the high accuracy of impression for TN group. In addition, for the comparison results between the material types used in splinting the open tray impression, the PH group showed a relatively lower standard deviation (0.1910 ± 0.1176 mm) than that of the PN group (0.2343 ± 0.0844 mm), PG group (0.2556 ± 0.1082 mm). Conclusion: The acrylic resin synthesized by light-induced polymerization exhibited a higher accuracy of impression taking than that of autopolymerizing acrylic resin. Meanwhile, the accuracy of impression taking was not dependent on the implant impression taking method or the presence of connection/fixation of impression copings.

Open reduction and internal fixation of mandibular fracture in an 11-month-old infant: a case report

  • Kim, Tae-Wan;Seo, Eun-Woo;Song, Seung-Il
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.2
    • /
    • pp.90-93
    • /
    • 2013
  • Mandibular fractures in infants are rare. This case report describes management of a mandibular fracture in an 11-month-old infant using a microplate and screws with open reduction. The surgical treatment was successful. Because the bone fragments were displaced and only the primary incisors had erupted, conservative treatment, such as an acrylic splint and circummandibular wiring, was not recommended. Nine weeks after surgery, the microplate was removed. The results showed complete clinical and radiological bone healing with normal eruption of deciduous teeth.

Repair of the Traumatic Oronasal Communication in a Dog with a Palatal Prosthesis : a Case Report (개에서 창상성 구비강 개통의 아크릴 부목을 이용한 치유 증례)

  • Shim, Kyung-Mi
    • Journal of Veterinary Clinics
    • /
    • v.26 no.6
    • /
    • pp.641-643
    • /
    • 2009
  • A 5-year-old intact female mixed dog was admitted to the Veterinary Teaching Hospital for reconstructive surgery of traumatic oronasal communication in the palatal region after suffering a facial gunshot injury. The surgical procedure involved making buccal mucosal flaps as well as a transposition flap of the hard palate mucoperiosteum from the tissue adjacent to the defect, followed by applying a prosthetic appliance to protect the surgical flaps. A satisfactory outcome was obtained using a palatal prosthesis.

MECHANO THERAPY OF PEDIATRIC CONDYLAR FRACTURES USING BENOIST'S APPLIANCCE : A CASE REPORT (Benoist씨 장치를 이용한 소아의 하악 과두 골절의 치험례)

  • Park, Sang-Wook;Cha, In-Ho;Kim, Seong-Oh;Choi, Byung-Jai;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.453-458
    • /
    • 2004
  • Mandibular fracture is less common in children than in adults. However, children are more susceptible to ankylosis and developmental disorders, and don't respond as well to intermaxillary fixation compared to adults. On the other hand, bone fracture is healed more quickly in children and complications are scarce. Mandibular fracture in children is usually treated successfully with acrylic splint therapy with or without the use of eyelet wires and intermaxillary fixation. Severe complications that include ankylosis and developmental disorders may occur. The frequency and severity of such complications can be mitigated with a shorter duration of intermaxillary fixation and good post-operative care. Encouraging mandibular physical therapy by increasing patient motivation may be necessary in such cases where the patient's response is poor and the duration of intermaxillary fixation increases; when the patient is unable to undergo physical therapy, or when intermaxillary fixation is not necessary with the patient showing only minor symptoms such as trismus. In this case report, a 6 year-old girl with bilateral condylar fracture was treated with elastic in both the upper and lower jaws to allow mandibular physical therapy using a Benoist's appliance, which allows opening, lateral, and protrusive retrusive movements of the mandible. A 7-month follow-up showed beneficial therapeutic effects such as increased mandibular movement and prevention of condylar ankylosis.

  • PDF

Effect of Temporary Anterior Positioning Splint Using Putty Impression Material on Acute Closed Lock (급성 과두 걸림의 치료에서 퍼티 고무 인상재로 제작한 임시 전방위치장치의 적용)

  • Song, Ji-Hee;Kim, Ji-Hyun;Kwon, Jeong-Seung;Ahn, Hyung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.37 no.4
    • /
    • pp.221-225
    • /
    • 2012
  • Disc dislocation without reduction, as known as closed lock, is a clinical condition in which the disc is dislocated from the condyle and does not return to normal position during condylar movement When the condition of disc dislocation without reduction is acute, the initial therapy should include an attempt to reduce or recapture the disc by manual manipulation. When patients report a history of being locked for 1 week or less, manual manipulation is usually successful. In patients with a longer history, success rate tends to decrease rapidly. If the disc has been successfully recaptured, placing an anterior positioning appliance is recommended to prevent clenching on the posterior teeth, which would likely redislocated the disc. But it is hard to make an appliance immediately in the clinic because it takes too much time. And making an appliance using self-curing acrylic resin is not very popular because of its discomfort by odor and working time. Also, if the patient has resin allergy or is under orthodontic treatment, or if it is impossible to control behavior of the patient, it has been restricted to make an appliance immediately. Therefore, to supplement this disadvantages, we tried to confirm about successful short term use of temporary anterior positioning splint made by using putty impression material after manual manipulation in this study.

LATE TREATMENT OF MALUNITED MAXILLARY FRACTURE (부정유합된 상악골 골절의 처치)

  • Chang, Se-Hong;Ann, Jye-Jynn;Kim, Doe-Gyeun;Jeong, Min-Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.1
    • /
    • pp.255-260
    • /
    • 1989
  • Unfavorable healing of maxillary fractures may impose functional and esthetic burdens upon the trauma victim. Malunited maxillary fractures are generally a result of treatment delay, incomplete or inaccurate immobilization of the fracture fragments, or infection. Dysfunctions of mastication, distortions in speech, gross defects in facial contour, and related psychic changes are problems which may require secondary correction. When it is necessary to delay definitive treatment or when inadequate maxillary fracture reduction is recognized within the first week following injury, the maxilla can be mobilized by heavy handed dental manipulation under anesthesia or by elastic traction to an external fixation appliance attached to the maxilla by arch bars or an acrylic splint. But malunited maxillary fracture that have progressed to bony malunion require osteotomy procedure in order to establish normal anatomic relationships. This report parents two cases of malunited unilateral maxillary fracture surgically corrected by unilateral Le Fort I osteotomy.

  • PDF