• Title/Summary/Keyword: acrylic resins

Search Result 135, Processing Time 0.022 seconds

Wettability of denture relining materials under water storage over time

  • Jin, Na-Young;Lee, Ho-Rim;Lee, Hee-Su;Pae, Ahran
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 2009
  • STATEMENT OF PROBLEM. Poor wettability of denture relining materials may lead to retention problems and patient discomfort. PURPOSE. Purpose of this study is to compare and evaluate wettability of nine denture relining materials using contact angle measurements under air and water storage over time. MATERIAL AND METHODS. Nine denture relining materials were investigated in this study. Two heat-curing polymethyl-methacrylate(PMMA) denture base materials: Vertex RS, Lang, one self-curing polyethyl-methacrylate(PEMA) chairside reline resin: Rebase II, six silicone relining materials: Mucopren soft, Mucosoft, $Mollosil^{{R}}$ plus, Sofreliner Touch, GC $Reline^{TM}$ Ultrasoft, Silagum automix comfort were used in this experiment. Contact angles were measured using high-resolution drop shape analysis system(DSA 10-MK2, KRUESS, Germany) under three conditions(in air after setting, 1 hour water storage, and 24 hours water storage). Nine materials were classified into three groups according to material composition(Group 1: PMMA, Group 2: PEMA, Group 3: Silicone). Mean values of contact angles were compared using independent samples t-test and one-way ANOVA, followed by a Scheffe's post hoc analysis($\alpha$=0.01). RESULTS. Contact angles of materials tested after air and water storage increased in the following order: Group 1(PMMA), Group 2(PEMA), Group 3(Silicone). Heat-cured acrylic denture base resins had more wettability than silicone relining materials. Lang had the highest wettability after 24 hours of water storage. Silicone relining materials had lower wettability due to their hydrophobicity. Wettability of all denture relining materials, except Rebase II and $Mollosil^{{R}}$ plus, increased after 24 hours of water storage. CONCLUSIONS. Conventional heat-cured resin showed the highest wettability, therefore, it can be suggested that heat-cured acrylic resin is material of choice for denture relining materials.

A STUDY ON THE BOND STRENGH OF 4-META ACRYLIC RESIN DENTURE BASE TO COBALT-CHROMIUM ALLOYS (4-META의치상레진과 Cobalt-Chromium계 합금의 접착강도에 관한 연구)

  • Sung, Moo Gyung;Kim, Kwang Nam;Chang, Ik Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.29-51
    • /
    • 1990
  • This study was designed to compre the tensile bond strength of 4-META containging denture base resin to Co-Cr alloys after various surface treatments. Especially the surface treatment of sandblasting the mental with aluminum oxide and treating in oxidizing solution composed of 3% aqueous sulfuric acid with 1% potassium manganate were compared. Effect of surface roughness on bonding was measured after sandblasting with 50um, 300um aluminun oxide and polishing with emery pater. Also the effects of wax and wax solvent on bonding were observed. According to the type of polymerization process, heat-cured Meta-Dent resin and autopolymerizing Meta-Fast resin were used. For some specimnens, the tensile bond strength were measured agter three pre-conditions : 1day after bonding, immersed in water at $75^{\circ}C{\pm}3^{\circ}C$ for 4weeks, under normal ambient condition for 4weeks. The following results were obtained from this study : 1. The bond strengths of resins containing 4-META were significantly higher than those of conventional denture base resins(p<0.05). 2. Autopolymerizing Meta-Fast resin had higher bond strength than heat-cured Meta-Dent, resin(p<0.05). 3. The bond strengths of Biosil and Nobilium to 4-META containging resins were not significally different(p>0.05). 4. Stable adhesion can be achieved when mechanically roughen the metal surface by snadblasting with $50{\mu}m$ aluminum oxide than treating in an oxidizing soluing with potassium manganate(p<0.05). 5. Once the metal surface is contaminated with wax, the bond srtength decreased greatly in spite of wax wash with boiling water. But the bond strength recovered significantly with the use of wax solvent 6. Meta-Dent resin had higher bond strength when roughen the metal surface with $50{\mu}m$ aluminum oxide than with $300{\mu}m$ aluminum oxide(p<0.05). In case of Meta-Fast, resin, the use of $300{\mu}m$aluminum oxide was a little advantageous of bonding, but was statistically insignificant(p>0.05).

  • PDF

Effect of artificial aging on mechanical and physical properties of CAD-CAM PMMA resins for occlusal splints

  • Julia Correa Raffaini;Eduardo Jose Soares;Rebeca Franco de Lima Oliveira;Rocio Geng Vivanco;Ayodele Alves Amorim;Ana Lucia Caetano Pereira;Fernanda Carvalho Panzeri Pires-de-Souza
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.5
    • /
    • pp.227-237
    • /
    • 2023
  • PURPOSE. This study aimed to assess and compare the color stability, flexural strength (FS), and surface roughness of occlusal splints fabricated from heat-cured acrylic resin, milled polymethyl methacrylate (PMMA)-based resin, and 3D-printed (PMMA) based-resin. MATERIALS AND METHODS. Samples of each type of resin were obtained, and baseline measurements of color and surface roughness were recorded. The specimens were divided into three groups (n = 10) and subjected to distinct aging protocols: thermomechanical cycling (TMC), simulated brushing (SB), and control (without aging). Final assessments of color and surface roughness and three-point bending test (ODM100; Odeme) were conducted, and data were statistically analyzed (2-way ANOVA, Tukey, P <.05). RESULTS. Across all resin types, the most significant increase in surface roughness (Ra) was observed after TMC (P < .05), with the 3D-printed resin exhibiting the lowest Ra (P < .05). After brushing, milled resin displayed the highest Ra (P < .05) and greater color alteration (∆E00) compared to 3D-printed resin. The most substantial ∆E00 was recorded after brushing for all resins, except for heat-cured resin subjected to TMC. Regardless of aging, milled resin exhibited the highest FS (P < .05), except when compared to 3D-printed resin subjected to TMC. Heat-cured resin exposed to TMC demonstrated the lowest FS, different (P < .05) from the control. Under control conditions, milled resin exhibited the highest FS, different (P < .05) from the brushed group. 3D-printed resin subjected to TMC displayed the highest FS (P < .05). CONCLUSION. Among the tested resins, 3D-printed resin demonstrated superior longevity, characterized by minimal surface roughness and color alterations. Aging had a negligible impact on its mechanical properties.

Synthesis of Amino-type Anion Exchanger from Acrylic Acid Grafted Polypropylene Nonwoven Fabric and Its Ion-Exchange Property (아크릴산 그라프트 폴리프로필렌 부직포로부터 아민형 음이온 교환체의 합성 및 이온교환특성(I))

  • Park, Hyun-Ju;Na, Choon-Ki
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.5
    • /
    • pp.527-534
    • /
    • 2006
  • The purpose of this study is the development of more effective filter-type polymer adsorbent for removal of anionic pollutants from wastewater. In order to synthesize the polymer adsorbent that possesses anionic exchangeable function, carboxyl(-COOH) group of PP-g-AA nonwoven fabric was converted into amine($-NH_2$) group by the chemical modification using diethylene triamine(DETA). FT-IR data indicate that amine group was introduced into PP-g-AA through amidation of grafted acrylic acid by reaction with DETA. The degree of amination increased with increase in the reaction time and temperature of the chemical modification process, and was significantly improved by the pre-swelling treatment of PP-g-AA with solvent and addition of metal chlorides as a catalyst in following order as $NH_4OH>MeOH{\geq}HCl{\geq}H_2O\;and\;AlCl_3>FeCl_3{\geq}SnCl_2{\gg}ZnCl_2{\geq}FeCl_2$, respectively. However, the addition of catalyst limited the reusability of DETA, hence was less useful from the viewpoint of cost effectiveness and waste management. The anion exchange capacity of the aminated PP-g-AA(PP-g-AA-Am) increased with increase in the degree of amination, but it reached maximum value at the degree of amination as about $50{\sim}60%$. The anion exchange capacity of PP-g-AA-Am was higher than those of commercial anion resins.

Effect of acidic beverages on surface roughness and color stability of artificial teeth and acrylic resin

  • Bitencourt, Sandro Basso;Catanoze, Isabela Arague;da Silva, Emily Vivianne Freitas;dos Santos, Paulo Henrique;dos Santos, Daniela Micheline;Turcio, Karina Helga Leal;Guiotti, Aimee Maria
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.55-60
    • /
    • 2020
  • PURPOSE. The aim was to evaluate the effect of four acidic beverages on the roughness (Ra) and color change (ΔEab) of two brands of artificial teeth and a heat-polymerized acrylic resin (HPAR) for use in a prosthetic base. MATERIALS AND METHODS. All materials were divided into 5 groups, according to the used acidic beverage (artificial saliva - control, red wine, orange juice, coke-based, and lemon juice-based soft drink). The immersion process was divided into two stages: T1 - immersion in the acidic solutions for 10 minutes for 14 days; T2 - after T1, the samples were immersed in grape juice for 14 days. The Ra of the samples was evaluated in a rugosimeter and the ΔEab in a spectrophotometer, before and after the immersions. The analysis of variance of one (ΔEab) and two factors (Ra) and Tukey were performed (α=.05). RESULTS. There was a statistical difference for roughness after immersion (T1) for Trilux and Tritone teeth, regardless of the acid solution. For Trilux teeth, all acid solutions increased Ra (P<.05). For Tritone teeth, only the coke-based soft drink did not statistically change Ra. Grape juice (T2) altered Ra only of artificial teeth (P<.05). The color was changed for all materials, after T1 and T2. CONCLUSION. In general, the acidic solutions changed the Ra and ΔEab of HPAR and artificial teeth after T1. The grape juice altered the roughness only of the artificial teeth, promoting a clinically acceptable color change in the materials.

Effect of Silane Coupling Agent on Adhesion Properties between Hydrophobic UV-curable Urethane Acrylate and Acrylic PSA (소수성 UV 경화형 우레탄 아크릴레이트와 아크릴 점착제 사이의 계면 부착력 향상을 위한 에폭시 실란의 영향)

  • Noh, Jieun;Byeon, Minseon;Cho, Tae Yeun;Ham, Dong Seok;Cho, Seong-Keun
    • Applied Chemistry for Engineering
    • /
    • v.31 no.2
    • /
    • pp.230-236
    • /
    • 2020
  • In this study, an adhesive tape with water and impact resistance for mobile devices was developed using a UV-curable urethane acrylate based polymer as a substrate. The substrate fabricated by UV-curable materials shows hydrophobicity and poor wettability, which significantly deteriorates the interface-adhesions between the substrate and acrylic adhesive. In order to improve the interface adhesion, 3-glycidoxy-propyl trimethoxysilane (GPTMS), a silane coupling agent having epoxy functional groups, was selected and incorporated into UV-curable urethane acrylate based polymer resins in various contents. The changes of the chemical composition according to the contents of GPTMS was studied with Fourier-transform infrared spectroscopy (FT-IR), energy-dispersive X-ray spectroscopy (EDX) and X-ray photoelectron spectroscopy (XPS) to know the surface bonding properties. Also mechanical properties of the substrate were characterized by tensile strength, gel fraction and water contact angle measurements. The peel strengths at 180° and 90° were measured to compare the adhesion between the substrate and adhesive according to the silane coupling agent contents. The mechanical strength of the urethane acrylate adhesive tape decreased as the silane coupling agent increased, but the adhesion between the substrate and adhesives increased remarkably at an appropriate content of 0.5~1 wt%.

EFFECT OF SURFACE DESIGN ON BOND STRENGTH OF RELINING DENTURE RESIN (결합면 형태가 이장용 레진의 결합강도에 미치는 영향)

  • Park Eun-Ju;Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.2
    • /
    • pp.167-174
    • /
    • 2004
  • Statement of problem: Removable partial denture and complete denture often require denture base relines to improve the fit against the tissue-bearing mucosa because of gradual changes in edentulous ridge contours and resorption of underlying bone structure. Purpose: This study was performed to investigate the effect of surface design on bond strength of relining denture base resins to denture base acrylic resin. Materials and method: Heat curing resin(Lucitone 199, Dentsply U.S.A. and Vertex, Dentimex, Holland), self curing resin(Tokuso rebase, Tokuyama, Japan), and visible light curing resin(Triad, Dentsply, U.S.A.) were used in this study. The surface designs were classified as butt, bevel and rabbet joint and the bond strengths were measured by Universial Testing Machine (Zwick 2020, Zwick Co., Germany). Results and Conclusion: The obtained results from this study were as follows ; 1. The bond strength of Vertex resin was higher than those of Tokuso rebase and Triad. 2. The bond strength of rabbet and bevel joint was higher than that of butt joint. 3. The failure mode of Triad and Tokuso rebase was mainly adhesive, but cohesive failure was shown mainly in vertex.

Study on Changes in Shape of Denatured Area in Skull-mimicking Materials Using Focused Ultrasound Sonication

  • Min, JeongHwa;Kim, JuYoung;Jung, HyunDu;Kim, JaeYoung;Noh, SiCheol;Choi, HeungHo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.1
    • /
    • pp.28-34
    • /
    • 2014
  • Recently, ultrasound therapy has become a new and effective treatment for many brain diseases. Therefore, skull-mimicking phantoms have been developed to simulate the skull and brain tissue of a human and allow further research into ultrasound therapy. In this study, the suitability of various skull-mimicking materials(HDPE, POM C, Acrylic) for studies of brain-tumor treatments was evaluated using focused ultrasound. The acoustic properties of three synthetic resins were measured. The skull-mimicking materials were then combined with an egg white phantom to observe the differences in the ultrasound beam distortion according to the type of material. High-intensity polyethylene was found to be suitable as a skull-mimicking phantom because it had acoustic properties and a denatured-area shape that was close to those of the skull,. In this study, a skull-mimicking phantom with a multi-layer structure was produced after evaluating several skull-mimicking materials. This made it possible to predict the denaturation in a skull in relation to focused ultrasound. The development of a therapeutic protocol for a range of brain diseases will be useful in the future.

MICROLEAKAGE OF 4 DIFFERENT COMPOSITE RESIN RESTORATIONS IN CLASS II CAVITY WITH CEMENTAL MARGIN (백악질 변연을 갖는 2급 와동에 충전된 4종 복합레진의 미세누출)

  • 조영곤;한세희;김은성
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.6
    • /
    • pp.492-498
    • /
    • 2001
  • The purpose of this study was to evaluate four different composite resins in vitro for microleakage in Class II box type restorations that have gingival margins apical to the cementoenamel junction. Forty caries free extracted human molars were used in this study. The Class II cavities were prepared 1.0mm below cementoenamel junction with a #701 carbide bur. The teeth were randomly divided into four groups, each group comprising 20 treated cavities according to adhesives and filling materials ; Group 1: Scotchbond Multipurpose/Z 100. Group 2: Ariston Liner/Ariston pHc, Group 3: One Step/Pyramid, Group 4: Prime & Bond NT/SureFil. To simulate the clinical situation during restoration placement, a restoration template was fabricated and composite resin was filled using a three sited light-curing incremental technique. The specimens were stored in the 100% humidity for 7 days prior to thermocycling. The specimens were immersed in 2% methylene blue dye solution for 24 hours and then embeded in transparent acrylic resin and sectioned mesiodistally with a diamond wheel saw. The degree of marginal leakage was scored under the stereomicroscope($\times$20) and the data were analyzed by Kruskal Wallis test and Mann Whitney test. (omitted)

  • PDF

AN EXPERIMFNENTAL STUDY ON THE SURFACE ROUGHNESS OF ACID ETCHING ENAMEL SURFACE IN HUMAN TEETH (산부식처리(酸腐蝕處理) 치아법랑질(齒牙琺瑯質) 표면(表面)의 조도(粗度)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Lee, Eun-Goo
    • Restorative Dentistry and Endodontics
    • /
    • v.5 no.1
    • /
    • pp.13-18
    • /
    • 1979
  • The purpose of this study was to measure the roughness on the acid -etching surface. The etching agents of three-kinds composite resins were used to etch the tooth surface. Newly extracted I5-anterior teeth were invested with self-curing acrylic resin, and the labial surface was exposed. The exposed labial side was polished with abrasive papers and finally polished on polishing machine with zinc oxide powder. After the teeth were polished, the specimens were washed by water and dried by air. Surface roughness tester, Taylor-Habson's Taly Surf-10, (Fig-1) was used to measure roughness of this unetched tooth surface. And that, the specimens were divided into three groups. The first group was etched with Restodent etchant, the second group was etched with Nuva-system etchant, and Hi-pol etching agent was used in the third group. And the surface roughness tester was used to measure roughness of the etching teeth surface. The results obtained were as follows. 1. The roughness of acid-etched enamel were increased $2{\mu}m$ to $6{\mu}m$. 2. Hi-pol etchant produced the smoothest surface($2.3{\mu}m$). 3. Restodent etchant($3.8{\mu}m$) and Nuva-system etchant($3.7{\mu}m$) produced rougher surface than Hi-pol.

  • PDF