• 제목/요약/키워드: acquired materials

검색결과 857건 처리시간 0.025초

단섬유 복합재료 사출성형물의 잔류응력 측정 (Measurement of Residual Stress Distribution in Injection-Molded Short Fiber Composites)

  • 김상균;이석원;윤재륜
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 추계학술발표대회 논문집
    • /
    • pp.61-63
    • /
    • 2001
  • Residual stress distribution in injection-molded short fiber composites was determined using layer-removal method. Polysterene with 3 vol% carbon fibers was injection-molded into the tensile specimen. With milling machine layer-removal process was conducted and the curvature data were acquired. Treuting and Read analysis which is assuming isotropic material, and White analysis considering anisotropy due to the fiber orientation were used to calculate residual stress of the flow direction through the thickness direction and compared with each other.

  • PDF

Metal artifact 감소를 위한 CT simulator 영상 재구성의 유용성 평가 (Evaluation of the reconstruction of image acquired from CT simulator to reduce metal artifact)

  • 최지훈;박진홍;최병돈;원희수;장남준;구장현;홍주완
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.191-197
    • /
    • 2014
  • 목 적 : CT simulation 시 고 밀도 인공물에 의해 발생된 metal artifact는 주변조직의 관찰능력 감소 및 CT number 변화에 영향을 미치게 된다. 본 연구에서는 CT 촬영 시 Metal Artifact Reduction for Orthopedic implants(O-MAR)의 유용성을 평가해 보고자 한다. 대상 및 방법 : CT simulator를 이용하여 Gammex phantom과 Rando phantom의 original 영상, 고 밀도 인공물을 삽입 후 획득한 non O-MAR 영상과 O-MAR 적용 영상을 획득하였다. CT 영상 평가를 위해 Gammex phantom CT 영상 내 5개 조직과 artifact 영향을 직접 받는 3개 지점에 관심영역(region of interest, ROI)을 각각 설정하고, CT number와 노이즈(standard deviation, SD)를 평균값으로 비교, 분석하였다. 고 밀도 인공물 주변조직의 CT number 변화에 따른 선량변화 확인을 위해 전산화치료계획시스템 Eclipse를 이용하여 Rando phantom CT 영상 3곳에 원기둥 체적을 형성하였다. 치료계획은 6 MV 광자선, 7개 조사면, 조사야 $15{\time}15cm$, 1회당 처방선량 100 cGy를 적용하여 수립하고 평균선량을 비교, 분석하였다. 두 실험 모두 original 영상을 기준으로 분석하였다. 결 과 : Gammex phantom을 이용한 영상평가 실험에서 각 영상별 5개 조직의 CT number 차이는 작았으며, artifact 영향을 직접 받는 3개 지점은 O-MAR 적용 시 original 영상과 유사하게 나타났다. 그리고 O-MAR 적용 시 8개 지점의 SD는 non O-MAR 영상보다 모두 감소되었다. Rando phantom을 이용한 선량변화 실험 또한 O-MAR 적용 시 original 영상과 유사하게 나타났다. 결 론 : O-MAR 적용 시 고 밀도 인공물 artifact로 인한 영상 왜곡 및 SD 감소로 영상의 질이 향상되었으며 CT number 보정에 유용하였다. 이는 체표윤곽도(contour) 생성 및 치료계획 수립에 이점이 있을 것이라 사료된다.

비파괴 검사를 이용한 세라믹 재료의 결함 검출 (Detection of Flaws in Ceramic Materials Using Non-Destructive Testing)

  • 김광백;우영운
    • 한국전자통신학회논문지
    • /
    • 제5권3호
    • /
    • pp.321-326
    • /
    • 2010
  • 본 논문에서는 세라믹을 비파괴 검사를 통하여 얻어진 영상에서, 조직의 이상이나 결함의 정도를 자동으로 확인하는 방법을 제안한다. 비파괴 검사를 통하여 얻어진 영상에서 소벨 마스크를 적용하여 윤곽선을 추출하고, 추출된 윤곽선의 방향 정보를 $9{\times}9$ 마스크에 적용하여 영역을 분류한다. 그리고 분류된 각 영역을 히스토그램 스트레칭을 적용하여 영상을 보정하고, 4-방향 윤곽선 알고리즘을 적용하여 객체를 추출한다. 그리고 추출된 객체의 영역에 대해 형태학적 정보를 이용하여 잡음을 제거한 후, 손상된 영역을 추출한다. 본 논문에서 제안한 방법을 비파괴검사를 통하여 얻어진 영상을 대상으로 실험한 결과, 손상된 영역이 정확히 검출되는 것을 확인하였다.

Effect of Improving Accuracy for Effective Atomic number (EAN) and Relative Electron Density (RED) extracted with Polynomial-based Calibration in Dual-energy CT

  • Daehong Kim;Il-Hoon Cho;Mi-jo Lee
    • 한국방사선학회논문지
    • /
    • 제17권7호
    • /
    • pp.1017-1023
    • /
    • 2023
  • The purpose of this study was to improve the accuracy of effective atomic number (EAN) and relative electron density (RED) using a polynomial-based calibration method using dual-energy CT images. A phantom composed of 11 tissue-equivalent materials was acquired with dual-energy CT to obtain low- and high-energy images. Using the acquired dual-energy images, the ratio of attenuation of low- and high-energy images for EAN was calibrated based on Stoichiometric, Quadratic, Cubic, Quartic polynomials. EAN and RED were extracted using each calibration method. As a result of the experiment, the average error of EAN using Cubic polynomial-based calibration was minimum. Even in the RED image extracted using EAN, the error of the Cubic polynomial-based RED was minimum. Cubic polynomial-based calibration contributes to improving the accuracy of EAN and RED, and would like to contribute to accurate diagnosis of lesions in CT examinations or quantification of various materials in the human body.

Study on the PET image quality according to various scintillation detectors based on the Monte Carlo simulation

  • Eunsoo Kim;Chanrok Park
    • 핵의학기술
    • /
    • 제27권2호
    • /
    • pp.129-132
    • /
    • 2023
  • Purpose: Positron emisson tomography (PET) is a crucial medical imaging scanner for the detection of cancer lesions. In order to maintain the improved image quality, it is crucial to apply detectors of superior performance. Therefore, the purpose of this study was to compare PET image quality using Monte Carlo simulation based on the detector materials of BGO, LSO, and LuAP. Materials and Methods: The Geant4 Application for Tomographic Emission (GATE) was used to design the PET detector. Scintillations with BGO, LSO and LuAP were modelled, with a size of 3.95 × 5.3 mm2 (width × height) and 25.0 mm (thickness). The PET detector consisted of 34 blocks per ring and a total of 4 rings. A line source of 1 MBq was modelled and acquired with a radius of 1 mm and length of 20 mm for 20 seconds. The acquired image was reconstructed maximum likelihood expectation maximization with 2 iteration and 10 subsets. The count comparison was carried out. Results and Discussion: The highest true, random, and scatter counts were obtained from the BGO scintillation detector compared to LSO and LuAP. Conclusion: The BGO scintillation detector material indicated excellent performance in terms of detection of gamma rays from emitted PET phantom.

Confocal Microscopy Measurement of the Fiber Orientation in Short Fiber Reinforced Plastics

  • Lee, Kwang Seok;Lee, Seok Won;Youn, Jae Ryoun;Kang, Tae Jin;Chung, Kwansoo
    • Fibers and Polymers
    • /
    • 제2권1호
    • /
    • pp.163-172
    • /
    • 2001
  • To determine three-dimensional fiber orientation states in injection-molded short fiber composites a CLSM (Confocal Laser Scanning Microscope) is used. Since the CLSM optically sections the composites, more than two cross-sections either on or below the surface of the composite can be obtained. Three dimensional fiber orientation states can be determined with geometric parameters of fibers on two parallel cross-sections. For experiment, carbon fiber reinforced polystyrene is examined by the CLSM. Geometric parameters of fibers are measured by image analysis. In order to compactly describe fiber orientation states, orientation tensors are used. Orientation tensors are determined at different positions of the prepared specimen. Three dimensional orientation states are obtained without the difficulty in determining the out-of-plane angles by utilizing images on two parallel planes acquired by the CLSM. Orientation states are different at different positions and show the shell-core structure along the thickness of the specimen.

  • PDF

Effect of Processing Time on the Microarc Oxidation Coatings Produced on Magnesium AZ61 Alloy at Constant Hybrid Voltage

  • Ur Rehman, Zeeshan;Jeong, Yeong Seung;Koo, Bon Heun
    • 한국재료학회지
    • /
    • 제25권10호
    • /
    • pp.509-515
    • /
    • 2015
  • MAO ceramic coatings were prepared on AZ61 magnesium alloy for various processing times ranging from 5 to 60 min, in an electrolyte solution based on silicate-fluoride. The mechanical, electrochemical and, microstructural properties and the phase compositions of the coating layers were investigated. In this work, unlike previous studies, coatings with high amounts of the $Mag_2SiO_4$ phase were formed which contained small amounts of MgO and $MgF_2$ at a processing condition of 30 min. A microstructural analysis revealed that the porosity of the coatings was reduced considerably with an increase in the processing time, together with a change in the pore geometry from an irregular to a spherical shape. Potentiodynamic polarization and mechanical testing results showed that the coatings acquired after a processing time of 30 min were superior to all of the others.

풍력발전기 모사 시스템에서의 균열 결함 진단에 대한 연구 (A Study on Crack Fault Diagnosis of Wind Turbine Simulation System)

  • 배근호;박종원;김봉기;최병오
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제14권4호
    • /
    • pp.208-212
    • /
    • 2014
  • An experimental gear-box was set-up to simulate the real situation of the wind-turbine. Artificial cracks of different sizes were machined into the gear. Vibration signals were acquired to diagnose the different crack fault conditions. Time-domain features such as root mean square, variance, kurtosis, normalized 6th central moments were used to capture the characteristics of different crack conditions. Normal condition, 1 mm crack condition, 2mm crack condition, 6mm crack condition, and tooth fault condition were compared using ANFIS and DAG-SVM methods, and three different DAG-SVM models were compared. High-pass filtering improved the success rates remarkably in the case of DAG-SVM.

RI계기를 이용한 성토시공 관리기법연구(II) -조립토함유율에 따른 보정 (A Study on Embankment Compaction Control System Using RI Gauge(II) Focuses on the Modification due to Gravel Content)

  • 나경준;정두영
    • 한국지반공학회지:지반
    • /
    • 제10권2호
    • /
    • pp.97-108
    • /
    • 1994
  • 본 연구에서는 기준공시체를 이용한 측정시험을 통해 도출된 RI교정계수가 모든 노상토재료에는 적합치 않다는 판단아래 모든 종류의 성토재료에 사용이 가능하고 신뢰성있는 RI측정이 가능하도록 조립토함유율을 변화시켜 가면서 기준공시체 제작과 이에 대한 측정실험을 통해 RI 측정값의 보정방법을 제안하므로써 모든 종류의 성토재료에 RI측정이 가능하도록 하였다. 또한 일반적인 다짐관리지표로 사용되는 건조밀도 외에 다짐도와 공기함유율 및 포화도와의 상관성을 각각 분석하여 이것들이 다짐관리지표로 사용될 수 있는지에 대한 적용성을 검토하였다.

  • PDF

MATERIAL INVESTIGATION AND ANALYSIS USING CHARACTERISTIC X-RAY

  • Oh, Gyu-Bum;Lee, Won-Ho
    • Nuclear Engineering and Technology
    • /
    • 제42권4호
    • /
    • pp.426-433
    • /
    • 2010
  • The characteristic X-rays emitted from materials after gamma ray exposure was simulated and measured. A CdTe semiconductor detector and a $^{57}Co$ radiation source were used for energy spectroscopy. The types of materials could be identified by comparing the measured energy spectrum with the theoretical X-ray transition energy of the material. The sample composition was represented by the $K_{\alpha1}$-line (Siegbahn notations), which has the highest intensity among the characteristic X-rays of each atom. The difference between the theoretic prediction and the experimental result of K-line measurement was < 0.61% even if the characteristic X-rays from several materials were measured simultaneously. 2D images of the mixed materials were acquired with very high selectivity.