• Title/Summary/Keyword: acoustic methods

Search Result 918, Processing Time 0.023 seconds

DFT-spread OFDM Communication System for the Power Efficiency and Nonlinear Distortion in Underwater Communication (수중통신에서 비선형 왜곡과 전력효율을 위한 DFT-spread OFDM 통신 시스템)

  • Lee, Woo-Min;Ryn, Heung-Gyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.8A
    • /
    • pp.777-784
    • /
    • 2010
  • Recently, the necessity of underwater communication and demand for transmitting and receiving various data such as voice or high resolution image data are increasing as well. The performance of underwater acoustic communication system is influenced by characteristics of the underwater communication channels. Especially, ISI(inter symbol interference) occurs because of delay spread according to multi-path and communication performance is degraded. In this paper, we study the OFDM technique to overcome the delay spread in underwater channel and by using CP, we compensate for delay spread. But PAPR which OFDM system has problem is very high. Therefore, we use DFT-spread OFDM method to avoid nonlinear distortion by high PAPR and to improve efficiency of amplifier. DFT-spread OFDM technique obtains high PAPR reduction effect because of each parallel data loads to all subcarrier by DFT spread processing before IFFT. In this paper, we show performance about delay spread through OFDM system and verify method that DFT spread OFDM is more suitable than OFDM for underwater communication. And we analyze performance according to two subcarrier mapping methods(Interleaved, Localized). Through the simulation results, performance of DFT spread OFDM is better about 5~6dB at $10^{-4}$ than OFDM. When compared to BER according to subcarrier mapping, Interleaved method is better about 3.5dB at $10^{-4}$ than Localized method.

Preliminary Results of Fractionated Stereotactic Radiotherapy for Benign Brain Tumors (양성 뇌종양에 대한 분할 정위 방사선치료의 예비 결과)

  • Choi, Byung-Ock;Kang, Ki-Mun
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.10-18
    • /
    • 2003
  • Purpose : To evaluate the role of fractlonated sterotactic radiotherapy (FSRT) in the management of benign brain tumors, we reviewed the clinical, and radiographic responses of patients treated. Methods and Materials : Between March 1995 and March 2002, 36 patients with benign brain tumors were treated by FSRT. The pathological diagnoses consisted of pituitary adenomas (12 patients), cranio-pharyngiomas (5 patients), meningiomas (10 patients), and acoustic neurinomas (9 patients). Radiotherapy doses of 25 to 35 Gy (3~6 Gy/fraction, 5~10 fractions) were prescribed to the 85~90% isodose line, depending upon the location, size and volume of the tumors. The median clinical and radiographical follow up periods were 31 (range, 2~74) and 21 (range, 4~56) months, respectively. Results : In the 35 patients that could be evaluated for their clinical response, 13 (37.1%) were considered improved, 16 (45.7%) stable and 6 (17.2%) worse. Of the 33 patients who had radiographic studies, tumor shrinkage was noted in 17 (51.5%), tumor stabilization in 13 (39.4%), and tumor progression in 3 (9.1%). Of the 17 tumor shrinkage patients, 7 (21.2%) showed a complete response. Acute radiation-induced complications occurred iin 11 (30.6%) patients. Conclusions : FSRT is considered a safe and effective treatment method for begin brain tumors, but large numbers of patients, with relatively long follow-up periods are needed to assess the exact role or effect of FSRT.

Image Processing Algorithms for DI-method Multi Touch Screen Controllers (DI 방식의 대형 멀티터치스크린을 위한 영상처리 알고리즘 설계)

  • Kang, Min-Gu;Jeong, Yong-Jin
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.3
    • /
    • pp.1-12
    • /
    • 2011
  • Large-sized multi-touch screen is usually made using infrared rays. That is because it has technical constraints or cost problems to make the screen with the other ways using such as existing resistive overlays, capacitive overlay, or acoustic wave. Using infrared rays to make multi-touch screen is easy, but is likely to have technical limits to be implemented. To make up for these technical problems, two other methods were suggested through Surface project, which is a next generation user-interface concept of Microsoft. One is Frustrated Total Internal Reflection (FTIR) which uses infrared cameras, the other is Diffuse Illumination (DI). FTIR and DI are easy to be implemented in large screens and are not influenced by the number of touch points. Although FTIR method has an advantage in detecting touch-points, it also has lots of disadvantages such as screen size limit, quality of the materials, the module for infrared LED arrays, and high consuming power. On the other hand, DI method has difficulty in detecting touch-points because of it's structural problems but makes it possible to solve the problem of FTIR. In this thesis, we study the algorithms for effectively correcting the distort phenomenon of optical lens, and image processing algorithms in order to solve the touch detecting problem of the original DI method. Moreover, we suggest calibration algorithms for improving the accuracy of multi-touch, and a new tracking technique for accurate movement and gesture of the touch device. To verify our approaches, we implemented a table-based multi touch screen.

Aerodynamic Study in Normal Korean and Patients with Vocal Polyp (정상인과 성대용종 환자에서의 공기역학적 검사)

  • 서장수;송시연;정유선;김정수;지덕환;이무경
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.10 no.1
    • /
    • pp.5-11
    • /
    • 1999
  • Background and Objectives : Recently, many people suffering from voice change visit otolaryngologist. So, it is important to study vocal function in patients with glottic or laryngeal disease. Aerodynamic investigation is valuable information about the efficiency of the larynx in translating air pressure to acoustic signal. The purpose of this study was to investigate the aerodynamic data in patients with vocal polyp, compare this data with that of the normal Korean. Materials and Methods : In aerodynamic study, maximum phonation time, mean air flow rate, phonatory flow volume and subglottal pressure were tested by using Aerophone II voice function analyzer in 157 normal korean and 143 patients with vocal polyp, aged from 20 to 69 years randomly selected. Results and Conclusion : In vocal polyp, maximum phonation time was significantly decreased and mean air How rate was increased. Phonatory flow volume was significantly decreased and subglottic pressure was increased only in female with vocal polyp. These data will be served as basic data of evaluation after treatment and postoperative assessment of the patients with vocal polyp.

  • PDF

Voice Onset Time in Patients with Bilateral Vocal Nodules (양측성 성대결절 환자의 발성시작시간(VOT)에 관한 연구)

  • Park, Sun-Young;Kim, Seong-Tae;Kim, Sang-Yoon;Choi, Seung-Ho;Roh, Jong-Lyel;Nam, Soon-Yuhl
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.17 no.2
    • /
    • pp.107-110
    • /
    • 2006
  • Background and Objeetives : There are few studies reported that specifically examined the voice onset time(VOT) in patients with bilateral vocal nodules. The purpose of this study was to study the characteristics of voice onset in patients with bilateral vocal nodules. Materials and Methods : 52 female patients with bilateral vocal nodules were examined, aged from 20 to 54 years, and were compared with 25 normal female control group. All subjects produced five repetitions of the voiceless stops $/p^h,\;t^h\;k^h/$ in vowel context /ai_a/. VOT was measured by the time between the release of the stops and the onset of voicing. Results : VOTs of the voiceless stops $/p^h/\;and\;/t^h/$ in patients with bilateral vocal nodules were significantly shorter than those of normal subjects. VOT of the $/k^h/$ in them was shorter than those of normals, but the difference was not significant. This results showed that VOTs of the voiceless stops in patients with bilateral vocal nodules were shorter than those of normal subjects. Conclusion : The rapid onset of voicing in patients with bilateral vocal nodules might be associated with increased laryngeal muscle tension by hard glottal attacks. We suggest that VOT can be a clinically useful acoustic parameter for evaluating voice in patients with bilateral vocal nodules.

  • PDF

The Correlation between The Size and Location of Vocal Polyp and Voice Quality, Before and After Laryngeal Microsurgery (후두미세수술 전후 성대 용종의 크기 및 위치가 음성의 질의 변화에 미치는 영향)

  • Han, Won Gue;Kim, Min-Su;Oh, Kyung Ho;Woo, Jeung Soo;Jung, Kwang Yoon;Kwon, Soon Young
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.27 no.2
    • /
    • pp.102-107
    • /
    • 2016
  • Background and Objectives : Vocal polyps are caused by inflammation induced by stress or irritation. Many patients with vocal polyps complain voice discomfort. For vocal polyps, surgery such as laryngeal microsurgery has been the mainstay of management. We analyzed the clinical features of vocal polyps, and how the size and location of vocal polyps affect the outcomes of surgery. Methods : We retrospectively reviewed 42 patients from March 2014 to December 2015, who were diagnosed as unilateral single vocal polyp. When we operated on a vocal polyp with laryngeal microscopy, we measured their size and location. The quality of voice was evaluated by GRABS scale, jitter, shimmer, NHR (noise to harmonic ratio), MPT (maximum phonation time), and VHI (voice handicap index) before operation and 4 weeks after operation. Results : When we divided the patients into large-sized vocal polyp group (the longest length >3 mm) and small-sized vocal polyp group (the longest length ${\leq}3mm$), all parameter differences tend to be greater at large sized vocal polyp. However, these differences were not statistically significant (p>0.05). When we divided into two groups depending on the volume of vocal polyp, no distinct tendency was found. When we compared the location (anterior, mid and posterior) of vocal polyp with the improvement of voice quality, more change was found at mid portion vocal polyp, except the difference of VHI. However, these differences were also not statistically significant (p>0.05). Conclusion : All parameter differences tend to be greater at large vocal polyp and polyp of the mid location.

  • PDF

MR Technology to 4T

  • Vaughan, Thomas
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.103-105
    • /
    • 2003
  • After fifteen years of development, Magnetic Resonance (MR) technology for human imaging and spectroscopy is reaching a refined state with FDA approved 3T clinical products from Siemens, GE, and Philips. Broker has cleared CE approval with a 4T system. Varian supports a 4T system platform as well. Shielded magnets are standard at 3T from GE, Oxford, Magnex, and IGC. A shielded 4T whole body magnet is available from Oxford. Stronger switched gradients and dynamic shim coils, desired at any field, areespecially useful at higher static magnetic fields B0. In addition to the higher currents required for higher resolution slice or volume selection afforded by higher SNR, whole body gradient coils will be driven at increasing slew rates to meet the needs of new cardiac applications and other requirements. For example 3T and 4T systems are now being equipped with 2kV, 500A gradient coils and amplifiers capable of generating 4G/cm in 200msec, over a 67+/-cm bore diameter. High field EPI applications require oscillation rates at 1 kHz and higher. To achieve a benchmark 0.2 ppm shim over a 30cm sphere in a high field magnet, at least four stages of shimming need to be considered. 1) A good high field magnet will be built to a homogeneity spec. falling in the range of 100 to 150 ppm over this 30cm spherical "sweet spot" 2) Most modern high field magnets will also have superconducting shim coils capable of finding 1.5 ppm by their adjustment during system installation. 3) Passive ferro-magnetic shimming combined with 4) active, high order room temperature shim coils (as many as five orders are now being recommended) will accomplish 0.2 ppm over the 30cm sphere, and 0.1 ppm over a human brain in even the highest field magnets for human studies. Safety concerns for strong, fast gradients at any B0 field include acoustic noise and peripheral nerve stimulation. One or more of the mechanical decoupling methods may lead to quieter gradients. Patient positioning relative to asymmetric or short gradient coils may limit peripheral nerve stimulation at higher slew rates. Gradient designs combining a short coil for local speed and strength with a longer coil for coverage are being developed for 3T systems. Local gradients give another approach to maximizing performance over a limited region while keeping within the physiologically imposed dB0/dt performance limits.

  • PDF

Phonetic analysis of Korean elementary students who had overseas study at early ages (조기 유학 후 귀국한 초등학생의 발음 이상에 대한 음성학적 연구)

  • Ryu, Mee-Heun;Lee, Chang-Woo
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.4
    • /
    • pp.579-584
    • /
    • 2010
  • Purpose : The number of the repatriated Korean students who had overseas study at early ages is increasing. They received foreign education, they can speak international languages, but they have many difficulties in articulation and intonation of the Korean language. This study aims to measure closure and aspiration duration, length of consonants, length of subsequent vowels, and ratio of consonants against subsequent vowels in vowel-consonant-vowel (VCV) syllables. Methods : This study compares the acoustic and phonetic characteristics of repatriated and native students, the ratio of articulation error of Korean plosives, the closure and aspiration duration, and the ratio of the aspiration duration against the closure duration. Results : The ratio of articulation error of Korean plosives between repatriated and native students is 19% and 2%, respectively. The closure duration was significantly longer in repatriated students than in native students. The aspiration duration was significantly longer in repatriated students than in native students. No difference was found in the ratio of aspiration duration against closure duration between the native and repatriated students. Conclusion : This study can be a good reference for estimating the phonetic difficulties of Korean elementary students who had overseas study at early ages.

Comparison of Voice Outcomes between Medialization Thyroplasty and Arytenoid Adduction with or without Injection Laryngoplasty in Unilateral Vocal Fold Paralysis Patients (일측성 성대마비 환자에서 내전형 갑상성형술, 피열연골 내전술, 피열연골내전술과 성대주입술 병행치료의 음성 결과 비교)

  • Jin, Hokyung;Won, Seong Jun;Choi, Nayeon;Son, Young-Ik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.28 no.2
    • /
    • pp.118-122
    • /
    • 2017
  • Background and Objectives : In unilateral vocal fold paralysis (VFP), medialization thyroplasty (MT), arytenoid adduction (AA) and injection layrngoplasty (IL) are the most common procedures to correct phonatory problems. There is no consensus that which procedure is superior to the other for correcting the glottal insufficiency. The purpose of this study was to compare the phonatory parameters between MT, AA and AA with IL (AA+IL) in patients with unilateral VFP. Materials and Methods : This retrospective study enrolled patients from 2005 to 2016. Total 72 patients (49 male, 23 female, mean age 54.5 years) were classified into three groups ; MT (n=28), AA (n=12), and AA+IL (n=32). GRBAS scales, maximum phonation time (MPT), jitter, shimmer, noise to harmonic ratio (NHR), and voice handicap index (VHI)-10 and VHI-30 were preoperatively and postoperatively collected and compared between the three groups. Results : Age, gender and cause of VFP were not significantly different between the three groups. In MT and AA groups, MPT, VHI, G (overall grade) and B (breathiness) were significantly improved. In AA+IL group, jitter, shimmer, NHR, MPT, VHI, G and B were significantly improved. In analysis of differences (pre-postoperative values), ${\Delta}$ jitter (p<0.001), ${\Delta}$ shimmer (p=0.031), and ${\Delta}$ NHR (p=0.002) were significantly different and AA+IL group showed the greatest improvement. Conclusion : Analysis of voice parameters showed that all the three procedures for patients with unilateral VFP are effective in the improvement of voice ; especially in MPT, VHI-10, G and B scales. Compared to the others, AA+IL provided the better acoustic values including jitter, shimmer and NHR.

  • PDF

Differentiation of Adductor-Type Spasmodic Dysphonia from Muscle Tension Dysphonia Using Spectrogram (스펙트로그램을 이용한 내전형 연축성 발성 장애와 근긴장성 발성 장애의 감별)

  • Noh, Seung Ho;Kim, So Yean;Cho, Jae Kyung;Lee, Sang Hyuk;Jin, Sung Min
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.28 no.2
    • /
    • pp.100-105
    • /
    • 2017
  • Background and Objectives : Adductor type spasmodic dysphonia (ADSD) is neurogenic disorder and focal laryngeal dystonia, while muscle tension dysphonia (MTD) is caused by functional voice disorder. Both ADSD and MTD may be associated with excessive supraglottic contraction and compensation, resulting in a strained voice quality with spastic voice breaks. The aim of this study was to determine the utility of spectrogram analysis in the differentiation of ADSD from MTD. Materials and Methods : From 2015 through 2017, 17 patients of ADSD and 20 of MTD, underwent acoustic recording and phonatory function studies, were enrolled. Jitter (frequency perturbation), Shimmer (amplitude perturbation) were obtained using MDVP (Multi-dimensional Voice Program) and GRBAS scale was used for perceptual evaluation. The two speech therapist evaluated a wide band (11,250 Hz) spectrogram by blind test using 4 scales (0-3 point) for four spectral findings, abrupt voice breaks, irregular wide spaced vertical striations, well defined formants and high frequency spectral noise. Results : Jitter, Shimmer and GRBAS were not found different between two groups with no significant correlation (p>0.05). Abrupt voice breaks and irregular wide spaced vertical striations of ADSD were significantly higher than those of MTD with strong correlation (p<0.01). High frequency spectral noise of MTD were higher than those of ADSD with strong correlation (p<0.01). Well defined formants were not found different between two groups. Conclusion : The wide band spectrograms provided visual perceptual information can differentiate ADSD from MTD. Spectrogram analysis is a useful diagnostic tool for differentiating ADSD from MTD where perceptual analysis and clinical evaluation alone are insufficient.

  • PDF