• Title/Summary/Keyword: acoustic methods

Search Result 918, Processing Time 0.041 seconds

A Study on Skin Status with Acoustic Measurements of Skin Friction Noise (피부 마찰 소음 측정을 통한 피부 상태 연구)

  • Chang, Yun Hee;Seo, Dae Hoon;Koh, A Rum;Kim, Sun Young;Lim, Jun Man;Han, Jong Seup;Lee, Sang Hwa;Park, Sun Gyoo;Kim, Yang Han
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.42 no.2
    • /
    • pp.103-109
    • /
    • 2016
  • Efficacy of cosmetics has been mainly evaluated by qualitative and quantitative methods based on visual sense, tactile sense and skin structure until now. In this study, we suggested a novel evaluation method for skin status based on sound; measuring and analyzing the rubbing noise generated by applying cosmetics. First, the rubbing noise was measured at a close range by a high-sensitivity microphone in anechoic environment, and the noises were analyzed by 1/3 octave band analysis in frequency-domain. Three conditions, 1) before washing, 2) after washing and 3) after application of cosmetics, were compared. As a result, sound pressure level (SPL) of rubbing noise after washing was larger than that of before washing, and the SPL of rubbing noise after cosmetic application was the smallest. Furthermore, the energy of rubbing noise after application was higher than that of the before and after washing conditions in a low frequency band (lower than 2 kHz region). Conversely, the energy of rubbing noise after application was much lower than the others in a high-frequency band (upper than 2 kHz region). This change of energy distribution was described as a balloon-skin model. High SPL in the low frequency region after the cosmetic applications was due to the increase of "flexibility index", while SPL in the high frequency region significantly decreased because of the attenuation which is related to "softness index". Therefore, we developed two indices based on the spectrum-energy difference for evaluating skin conditions. This proposed method and indices were verified via skin flexibility and roughness measurement using cutometer and primos respectively. These results suggest that acoustic measurement of skin friction noise may be a new skin status evaluation method.

Type I Thyroplasty Using Prefabricated Hydroxylapatite Implant(VoCoM$^{\circledR}$) (미리 제작된 Hydroxylapatite 보형물을(VoCoM$^{\circledR}$) 이용한 제 1 형 갑상성형술)

  • 이현종;정한신;백정환;손영익
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.14 no.2
    • /
    • pp.117-122
    • /
    • 2003
  • Background and Objectives : $VoCoM^{\circledR}$ is a commercialized set composed of prefabricated hydroxylapatite implants and shims of various sizes which are specially designed for the type I thyroplasty. Even though a previously published preliminary report showed that $VoCoM^{\circledR}$ is a convenient and safe product for the type I thyroplasty, further investigations or experiences are yet to be reported. Authors aimed to evaluate the efficacy of $VoCoM^{\circledR}$type I thyroplasty, and its advantage and/or disadvantage. Materials and Method : Twenty three consecutive patients with unilateral vocal cord palsy enrolled for the study, who received type I thyroplasty with $VoCoM^{\circledR}$ between July 2001 and June 2003. Acoustic, aerodynamic and stoboscopic analyses were performed prior to surgery and 1 to 3 months after surgery. Speech language pathologists evaluated their voice quality by GRBAS scale, and patients themselves reported subjective changes of their voice by visual analog scale. Results : The average time for the operation was 80 min, which is about 30 min less than other methods. Preoperative jitter was 3.25$\pm$1.65% and improved to 1.94$\pm$1.79% postoperatively (p<0.05). Preoperative shimmer was 9.72$\pm$6.56% and improved to 5.61 $\pm$3.76% (p<0.05), Maximal phonation time increased from 4.41$\pm$2.99 to 7.98$\pm$4.35 sec (p<0.05) The postoperative stroboscopy revealed an effective medialization in 91.3% of the patients. The subjective phonetic improvements were reported in 21 out of 23 patients. GRBAS scale improved from 2.71$\pm$0.46 to 1.47$\pm$1.12(p<0.05). Additional medialization with $Gore-Tex^{\circledR}$ was easily performed in two revision cases. Previously inserted $VoCoM^{\circledR}$ implant was hard to remove because of the tight integration of soft tissues around the implant. Side effects such as extrusion or foreign body reaction are not observed. $VoCoM^{\circledR}$ was relatively expensive and costed more than 10 times of $Gore-Tex^{\circledR}$. Conclusion : Prefabricated hydroxylapatitie implant($VoCoM^{\circledR}$) provides a convenient, safe and efficient way of vocal fold medialization. However it is relatively expensive and hard to remove.

  • PDF

The Influence of the Regional Weather in Geriatric Trauma (지역기상이 노인외상에 미치는 영향)

  • Kim, Jung Ho;Do, Byung Soo;Lee, Sam Beom;Lee, Sung Hoon;Si, Jong Won;Lee, Jae Young;Kim, Oh Lyong
    • Journal of Trauma and Injury
    • /
    • v.19 no.2
    • /
    • pp.97-104
    • /
    • 2006
  • Purpose: Many factors influence the occurrence and severity of geriatric trauma, and regional weather is regarded as one factor that influences geriatric trauma. In this study, to predict the type, severity, and incidence of geriatric trauma patient, we analyzed the influence of regional weather on geriatric trauma. Methods: The subjects of our investigation were trauma patients over sixty-five years of age who visited the Emergency Department (ED) of Yeungnam University Hospital during a one-year period. We retrospectively reviewed the medical charts of 436 geriatric trauma patients, and the data were analyzed by using SPSS 12.0 for Window. The weather was based on data from the Korea Meteorological Administration. Results: The average age was 72.8 years old, and the ratio of males to females was 1:1.1. The mean spell out ISS was 10.8, and no difference was found between males and females. Slips were the most common cause of trauma. The largest numbers of aged trauma patients, 46, visited the ED in May, and the smallest number of such patients, 24, visited the ED in December. In addition to, summer saw the largest number of aged trauma patients. The type of trauma, the Injury Severity Score, and the number of patients had no relationship with season. On sunny days, the ISS was larger in patients who had hypotension and who had tachycardia. On rainy day, the ISS was larger in male patients and cultivator accident patients. The number of patients was larger on partly cloudy days. Conclusion: In spring and summer and on partly cloudy days, we must be prepared to treat aged traumatized patients in the E.D. On rainy days, visual sensation, tactual sense, and acoustic sense must be closely examined. In addition,on rainy day, aged male traumatized patients or cultivator accident patients must to be closely observation.

A Study on Performance Evaluation of Hidden Markov Network Speech Recognition System (Hidden Markov Network 음성인식 시스템의 성능평가에 관한 연구)

  • 오세진;김광동;노덕규;위석오;송민규;정현열
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.4
    • /
    • pp.30-39
    • /
    • 2003
  • In this paper, we carried out the performance evaluation of HM-Net(Hidden Markov Network) speech recognition system for Korean speech databases. We adopted to construct acoustic models using the HM-Nets modified by HMMs(Hidden Markov Models), which are widely used as the statistical modeling methods. HM-Nets are carried out the state splitting for contextual and temporal domain by PDT-SSS(Phonetic Decision Tree-based Successive State Splitting) algorithm, which is modified the original SSS algorithm. Especially it adopted the phonetic decision tree to effectively express the context information not appear in training speech data on contextual domain state splitting. In case of temporal domain state splitting, to effectively represent information of each phoneme maintenance in the state splitting is carried out, and then the optimal model network of triphone types are constructed by in the parameter. Speech recognition was performed using the one-pass Viterbi beam search algorithm with phone-pair/word-pair grammar for phoneme/word recognition, respectively and using the multi-pass search algorithm with n-gram language models for sentence recognition. The tree-structured lexicon was used in order to decrease the number of nodes by sharing the same prefixes among words. In this paper, the performance evaluation of HM-Net speech recognition system is carried out for various recognition conditions. Through the experiments, we verified that it has very superior recognition performance compared with the previous introduced recognition system.

  • PDF

Research for Characteristics of Sound Localization at Monaural System Using Acoustic Energy (청각에너지를 이용한 모노럴 시스템에서의 음상 정위 특성 연구)

  • Koo, Kyo-Sik;Cha, Hyung-Tai
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.4
    • /
    • pp.181-189
    • /
    • 2011
  • According to developments of digital signal processing, 3D sound come into focus on multimedia systems. Many studies on 3d sound have proposed lots of clues to create realistic sounds. But these clues are only focused on binaural systems which two ears are normal. If we make the 3d sound using those clues at monaural systems, the performance goes down dramatically. In order to use the clues for monaural systems, we have studies algorithms such as duplex theory. In duplex theory, the sounds that we listen are affected by human's body, pinna and shoulder. So, we can enhance sound localization performances using its characteristics. In this paper, we propose a new method to use psychoacoustic theory that creates realistic 3D audio at monaural systems. To improve 3d sound, we calculate the excitation energy rates of each symmetric HRTF and extract the weights in each bark range. Finally, they are applied to emphasize the characteristics related to each direction. Informal listening tests show that the proposed method improves sound localization performances much better than the conventional methods.

Usefulness of S/Z Ratio and Maximum Phonation Time in Unilateral Vocal Fold Paralysis with Decreased Pulmonary Function (최장발성폐기능저하를 동반한 일측성 성대마비 환자에서의 S/Z Ratio와 최장 발성시간(Maximum Phonation Time)의 유용성 비교)

  • Park, Joon Pyo;Jeong, Go-Eun;Kang, Byung Chul;Kim, Seong-Tae;Nam, Soon Yuhl;Kim, Sang-Yoon;Roh, Jong-Lyel;Choi, Seung-Ho
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.23 no.2
    • /
    • pp.129-132
    • /
    • 2012
  • Background and Objectives : MPT is directly related to degree of glottal closure. So it is widely used in the assessment of glottal closure with unilateral vocal fold paralysis. But MPT could be influenced not only by glottal closure but also by pulmonary function. So MPT might not reflect glottal closure in UVFP with decreased pulmonary function. The purpose of the study is to evaluate usefulness of MPT and ratio of /s/ time to /z/ time before and after injection laryngoplasty in UVCP with decreased pulmonary function. Materials and Methods : This study involved 34 patients with unilateral vocal fold paralysis : with decreased pulmonary function in group A (n=15) : with normal pulmonary function in group B (n=19). All patients underwent injection laryngoplasty. Paramters of perceptual analysis, acoustic analysis, aerodynamic analysis, videostroboscopy were compared between two groups. Results : Breathness and asthenic scale, G scale of perceptual analysis were significantly improved in both groups. Glottal gap index were significantly decreased after injection in both groups. In aerodynamic analysis, MPT was improved after injection laryngoplasty in both groups, but S/Z ratio was improved only in group B. In correlation analysis, /s/ time was not correlated with pulmonary function. Conclusion : S/Z ratio reflects neither the pulmonary function nor the glottal clousure properly. MPT is more useful indicator than S/Z ratio to evaluate vocal fold paralysis even with decreased pulmonary function.

  • PDF

Low Noise Vacuum Cleaner Design (저소음 청소기 개발)

  • Joo, Jae-Man;Lee, Jun-Hwa;Hong, Seun-Gee;Oh, Jang-Keun;Song, Hwa-Gyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.939-942
    • /
    • 2007
  • Vacuum cleaner is a close life product that can remove various dusts from our surroundings. However well vacuum cleaner clean our environments, many people are looking away from it, due to its loud noise. Its noise causes a big trouble in the usual life, for example, catch calls, TV watching and discussing etc. To reduce these inconveniences, noise reduction methods and systematic design of low noise vacuum cleaner are studied in this paper. At first, sound quality investigation is performed to get the noise level and quality that make people TV watching and catch calls available. Based on the European and domestic customer SQ survey result, sound power, peak noise level and target sound spectrum guideline are studied and introduced. As a second, precise product sound spectrums are designed into each part based on the sound quality result. Fan-motor, brush, mainbody, cyclone spectrums are decided to get the final target sound based on the contribution level. Fan-motor is the major noise source of vacuum cleaner. Specially, its peak sound, RPM peak and BPF Peak, cause the people nervous. To reduce these peak sounds, high rotating impeller and diffuser are focused due to its interaction. A lot of experimental and numerical tests, operation points are investigated and optimization of flow path area between diffusers is performed. As a bagless device, cyclones are one of the major noise sources of vacuum cleaner. To reduce its noise, previous research is used and adopted well. Brush is the most difficult part to reduce noise. Its noise sources are all comes from aero-acoustic phenomena. Numerical analysis helps the understanding of flow structure and pattern, and a lot of experimental test are performed to reduce the noise. Gaps between the carpet and brush are optimized and flow paths are re-designed to lower the noise. Reduction is performed with keeping the cleaning efficiency and handling power together and much reduction of noise is acquired. With all above parts, main-body design is studied. To do a systematic design, configuration design developments technique is introduced from airplane design and evolved with each component design. As a first configuration, fan-motor installation position is investigated and 10 configuration ideas are developed and tested. As a second step, reduced size and compressed configuration candidates are tested and evaluated by a lot of major factor. Noise, power, mass production availability, size, flow path are evaluated together. If noise reduction configuration results in other performance degrade, the noise reduction configuration is ineffective. As a third configuration, cyclones are introduced and the size is reduced one more time and fourth, fifth, sixth, seventh configuration are evolved with size and design image with noise and other performance indexes. Finally we can get a overall much noise level reduction configuration. All above investigations are adopted into vacuum cleaner design and final customer satisfaction tests in Europe are performed. 1st grade sound quality and lowest noise level of bagless vacuum cleaner are achieved.

  • PDF

Acoustic differences according to the epileptic focus in benign partial epilepsy with centrotemporal spikes patients (양성 부분 간질 환아에서 간질 발생 위치에 따른 음성언어 분석)

  • Kim, Jung Tae;Choi, Sang Hoon;Kim, Sun Jun
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.9
    • /
    • pp.896-900
    • /
    • 2007
  • Purpose : The aim of this study was to investigate the speech problems in benign rolandic epilepsy (BRE) according to the seizure focus in EEG and semiology. Methods : Twenty three patients [right origin (13 patients) or left side (10 patients)] who met the BRE criteria by International League Against Epilepsy (ILAE) were prospectively enrolled. We excluded the patients who had abnormal MRI or showed both side spikes in EEG. Computerized Speech Lab was used to assess the speech characteristics of the patients. Results : The error pattern of laryngeal articulation in BRE was exclusively substitution of stop consonants, these errors showed more frequent in the left group (16.0% vs 25.5%). Voice onset time (VOT) of stop consonants and Total duration (TD) of word in both groups were prolonged than normal control group, especially in left group (P<0.05). The first formant of vowel /o/ and second formant of /e/ were significantly decreased in left group (P<0.05). The right group scored wider on pitch range ($192.9{\pm}54.0Hz$) and energy range in spontaneous speech ($14.2{\pm}6.4db$) than the left group ($233.3{\pm}12.5Hz$, $19.4{\pm}9.3db$, respectively, P>0.05). Duration of counting (5 to 9) in left group slower than right group ($8.6{\pm}1.7$ vs $7.9{\pm}1.8sec$). Conclusion : Our data suggested that interictal spikes and seizures in either centrotemporal sides, especially left side group, may induce speech problems. We recommend the logopedic and phoniatric evaluations of speech in BRE patients.

Internal Defection Evaluation of Spot Weld Part and Carbon Composite using the Non-contact Air-coupled Ultrasonic Transducer Method (비접촉 초음파 탐상기법을 이용한 스폿용접부 및 탄소복합체의 내부 결함평가)

  • Kwak, Nam-Su;Lee, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6432-6439
    • /
    • 2014
  • The NAUT (Non-contact Air coupled Ultrasonic Testing) technique is one of the ultrasonic testing methods that enables non-contact ultrasonic testing by compensating for the energy loss caused by the difference in acoustic impedance of air with an ultrasonic pulser receiver, PRE-AMP and high-sensitivity transducer. As the NAUT is performed in a state of steady ultrasonic transmission and reception, testing can be performed on materials of high or low temperatures or specimens with a rough surface or narrow part, which could not have been tested using the conventional contact-type testing technique. For this study, the internal defects of spot weld, which are often applied to auto parts, and CFRP parts, were tested to determine if it is practical to make the NAUT technique commercial. As the spot welded part had a high ultrasonic transmissivity, the result was shown as red. On the other hand, the part with an internal defect had a layer of air and low transmissivity, which was shown as blue. In addition, depending on the PRF (Pulse Repetition Frequency), an important factor that determines the measurement speed, the color sharpness showed differences. With the images obtained from CFRP specimens or an imaging device, it was possible to identify the shape, size and position of the internal defect within a short period of time. In this paper, it was confirmed in the above-described experiment that both internal defect detection and image processing of the defect could be possible using the NAUT technique. Moreover, it was possible to apply NAUT to the detection of internal defects in the spot welded parts or in CFRP parts, and commercialize its practical application to various fields.

3D Node Deployment and Network Configuration Methods for Improvement of Node Coverage and Network Connectivity (커버리지와 네트워크 연결성 향상을 위한 3차원 공간 노드 배치 및 망 구성 방법)

  • Kim, Yong-Hyun;Kim, Lee-Hyeong;Ahn, Mirim;Chung, Kwangsue
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37B no.9
    • /
    • pp.778-786
    • /
    • 2012
  • Sensors that are used on wireless sensor networks can be divided into two types: directional sensors, such as PIR, image, and electromagnetic sensors; and non-directional sensors, such as seismic, acoustic and magnetic sensors. In order to guarantee the line-of-sight of a directional sensor, the installation location of the sensor must be higher than ground level. Among non-directional sensors, seismic sensors should be installed on the ground in order to ensure the maximal performance. As a result, seismic sensors may have network connectivity problems due to communication failure. In this paper, we propose a 3D node deployment method to maximize the coverage and the network connectivity considering the sensor-specific properties. The proposed method is for non-directional sensors to be placed on the ground, while the directional sensor is installed above the ground, using trees or poles, to maximize the coverage. As a result, through the topology that the detection data from non-directional sensors are transmitted to the directional sensor, we can maximize the network connectivity. Simulation results show that our strategy improves sensor coverage and network connectivity.