• 제목/요약/키워드: acoustic energy

검색결과 848건 처리시간 0.032초

해저지형${\cdot}$지층탐사에 적용되는 음파특성 (Acoustic Characteristics Applied to Seafloor and Sub-bottom Survey)

  • 김성렬;이용국;정백훈
    • 한국지구과학회:학술대회논문집
    • /
    • 한국지구과학회 2005년도 추계학술발표회 논문집
    • /
    • pp.42-50
    • /
    • 2005
  • The electromagnetic (light) waves are limited to penetrate the media, ie, water and sea-bottom layers, due to high energy attenuation, but acoustic (sound) waves play as the good messenger to gather the underwater target information. Therefore the acoustic methods are applied to almost of ocean equipments and technology in terms of in-water and sub-bottom surveys. Generally the sound character is controlled by its frequency. In case that the sound source is low frequency, the penetration is high and the resolution is low. On the other hand, its character is reversed at the high frequency. The common character at the both of light and sound is the energy damping according to the travel distance increase.

  • PDF

플래즈머용사에 의한 세라믹 코팅 강재의 음향방출 특성 (Acoustic Emission Characteristics of Ceramic Coated Steel by Plasma Spraying)

  • 김귀식
    • 동력기계공학회지
    • /
    • 제2권3호
    • /
    • pp.49-54
    • /
    • 1998
  • This paper is investigated of hardness and adhesiveness of plasma sprayed coating steels by AE(Acoustic Emission) testing when loading a tensile. AE Parameters used are Event, Count, Energy and Amplitude. Test specimens are carbon steel(S45C) with sprayed coating layers of Ni-4.5wt.%Al(bond coating) and $TiO_2$(top coating), and carry out heat treatment at $800^{\circ}C\;and\;1000^{\circ}C$, respectively. The micro-hardness of the heat treatment specimen have been improved more than that of non-heat treatment. On the tensile test, the process and occurence of the exfoliation of the sprayed coating layer can be estimated by AE Characteristics of AE parameters, such as event, count, amplitude and energy, on the layer exfoliation are shown the similar aspects. The exfoliation of bond coating occure at about 20% of strain and top coating is about 5% of strain.

  • PDF

음향방출을 이용한 탄소섬유강화 플라스틱의 손상 평가에 관한 연구 (A Study on the Damage Estimation of CFRP using Acoustic Emission)

  • 이장규;박성완;김봉각
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.307-312
    • /
    • 2003
  • The object of this study is to investigate a damage estimation of single edge cracked tensile specimens ($2_a$/W) as a function of acoustic emission (AE) according to the unidirectionally oriented carbon/epoxy composites, CFRP AE signals were analyzed and classified 3 regions by event counts, energy and amplitude for coressponding applied load. On tensile loading and using the results of the AE analysis, it was found that the event counts, cumulative counts or energy, and amplitude distributions useful for the prediction of damage failure.

  • PDF

시간영역 빔포밍을 사용한 풍력터빈 축소모델 소음원 측정 (Acoustic Noise Measurement for the Wind Turbine Blade by Using Time-domain Beamforming)

  • 조태환;김철완
    • 신재생에너지
    • /
    • 제5권2호
    • /
    • pp.25-30
    • /
    • 2009
  • The wind tunnel test to identify the acoustic noise source position of the wind turbine blade was conducted in KARI low speed wind tunnel. Microphone array and time-domain beamforming methodology was applied to this study. To reduce the data processing time, a modified beamforming method with a criteria between calculation time step and grid size for rotating angle in the cylinderical coordinate system was proposed. The test results shows that the data processing time to identify the noise source position was reduced to 20% compared with conventional method. And the dominant noise source of the blade moves from inboard to blade tip as the frequency increases.

  • PDF

AE 센서를 이용한 헤드/디스크 틈새의 텁촉력 측정에 관한 실험적 연구 (An Experimental Study on Measurement of Contact Force of Head/Disk Interface Using Acoustic Emission Sensor)

  • 김지훈;김도형;황평
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제28회 추계학술대회
    • /
    • pp.278-284
    • /
    • 1998
  • In order to measure the real contact force between head and disk on hard disk drive quantitatively, many technique of measurement have been developed. Acoustic Emission Sensor can be used for detect elastic energy of head/disk contact as arms value. In this study using pencil breaking test is proposed for finding contact force using transfer function between calibrated force and real contact force. And real AE data of subambient and tripad slider shows bending and torsional mode and their energy are dominant in hard disk and head contact.

  • PDF

Infant Crying Acoustic Characteristics Evoking Unpleasant Emotions in Mothers

  • Kim, Yeoun-Jung
    • International Journal of Human Ecology
    • /
    • 제12권2호
    • /
    • pp.109-117
    • /
    • 2011
  • This study examines the infant crying acoustic characteristics likely to arouse negative emotions and distress in mothers. We used samples of infant crying from three situations (hunger, pain, and the mother's absence) in six healthy infants over six months. We played the recordings of infants crying to 90 mothers in the care of infants and had them self-evaluate emotions and feelings. In addition, the sounds were analyzed acoustically through a CSL4400 to analyze frequency, energy, total expiratory time, and the number of the expirations. In this study, cries due to pain and the absence of the mother caused more unpleasant emotions and irritation in comparison to the infant sounds of hunger. In particular, crying from the absence of the mother caused the most distress. An analysis of these sounds showed that crying in the situations of pain and the absence of the mother were strong in frequency, high energy, and prolonged. These results suggest a relation between infant crying acoustical characteristics and the feelings of distress by the mother.

Spatio-temporal Charge Distribution in Electric Double Layer Capacitors observed by pulsed Electro Acoustic Method

  • Sung, Youl-Moon
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권4호
    • /
    • pp.182-187
    • /
    • 2007
  • The use of the pulsed electro acoustic (PEA) method allowed us to perform the direct observations of spatio-temporal charge distributions in Electric double layer capacitors (EDLCs) based on polarizable nanoporous carbonaceous electrode. The negative charge density became the maximum, about $205C/m^3$ at the region where was near to collector layer in EDLCs for case $V_{DC}=2.5V$, while the positively charged density became the maximum, about $61.1C/m^3$ at the region where it was located around the cathode layer. The performance of the best sample was found to be better in terms of the charge density (Cs) and specific energy ($E_s$) with a maximum value of ${\sim}8.4F/g$ and 26 Wh/kg. The $C_s$ obtained from the PEA method agreed well with that from the energy conversion method. The PEA measurement used here is a very useful method to quantitively investigates the spatio-temporal charge distribution in EDLCs.

An improved cross-correlation method based on wavelet transform and energy feature extraction for pipeline leak detection

  • Li, Suzhen;Wang, Xinxin;Zhao, Ming
    • Smart Structures and Systems
    • /
    • 제16권1호
    • /
    • pp.213-222
    • /
    • 2015
  • Early detection and precise location of leakage is of great importance for life-cycle maintenance and management of municipal pipeline system. In the past few years, acoustic emission (AE) techniques have demonstrated to be an excellent tool for on-line leakage detection. Regarding the multi-mode and frequency dispersion characteristics of AE signals propagating along a pipeline, the direct cross-correlation technique that assumes the constant AE propagation velocity does not perform well in practice for acoustic leak location. This paper presents an improved cross-correlation method based on wavelet transform, with due consideration of the frequency dispersion characteristics of AE wave and the contribution of different mode. Laboratory experiments conducted to simulate pipeline gas leakage and investigate the frequency spectrum signatures of AE leak signals. By comparing with the other methods for leak location identification, the feasibility and superiority of the proposed method are verified.

Factors Related to Successful Energy Transmission of Focused Ultrasound through a Skull : A Study in Human Cadavers and Its Comparison with Clinical Experiences

  • Jung, Na Young;Rachmilevitch, Itay;Sibiger, Ohad;Amar, Talia;Zadicario, Eyal;Chang, Jin Woo
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권6호
    • /
    • pp.712-722
    • /
    • 2019
  • Objective : Although magnetic resonance guided focused ultrasound (MRgFUS) has been used as minimally invasive and effective neurosurgical treatment, it exhibits some limitations, mainly related to acoustic properties of the skull barrier. This study was undertaken to identify skull characteristics that contribute to optimal ultrasonic energy transmission for MRgFUS procedures. Methods : For ex vivo skull experiments, various acoustic fields were measured under different conditions, using five non-embalmed cadaver skulls. For clinical skull analyses, brain computed tomography data of 46 patients who underwent MRgFUS ablations (18 unilateral thalamotomy, nine unilateral pallidotomy, and 19 bilateral capsulotomy) were retrospectively reviewed. Patients' skull factors and sonication parameters were comparatively analyzed with respect to the cadaveric skulls. Results : Skull experiments identified three important factors related skull penetration of ultrasound, including skull density ratio (SDR), skull volume, and incidence angle of the acoustic rays against the skull surface. In clinical results, SDR and skull volume correlated with maximal temperature (Tmax) and energy requirement to achieve Tmax (p<0.05). In addition, considering the incidence angle determined by brain target location, less energy was required to reach Tmax in the central, rather than lateral targets particularly when compared between thalamotomy and capsulotomy (p<0.05). Conclusion : This study reconfirmed previously identified skull factors, including SDR and skull volume, for successful MRgFUS; it identified an additional factor, incidence angle of acoustic rays against the skull surface. To guarantee successful transcranial MRgFUS treatment without suffering these various skull issues, further technical improvements are required.