• 제목/요약/키워드: acid gas

검색결과 2,062건 처리시간 0.029초

전류검출형 가스센서의 기술 (Technology of Amperometric Gas Sensors)

  • 김귀열
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.222-225
    • /
    • 2002
  • The nitrogen oxides, NO and NO2, abbreviated usually as NOx, emitted from combustion facilities such as power plants and automobiles are the typical air-pollutants causing acid rain and photochemical smog. In order to solve the NOx-related pollution problems effectively, we need efficient techniques to monitor NOx in the combustion exhausts and in environments. Development of solid-state electrochemical devices for detecting NOx is demonstrated based on various combination of solid electrolytes and auxiliary sensing materials. The object of this research is to develop various sensor performance for solid state amperometric sensor, and to test gas sensor performance manufactured. So we try to present a guidance for developing amperometric gas sensor.

  • PDF

염산 흡입 후 발생한 Reactive Airways Dysfunction Syndrome (RADS) 1례 (Reactive Airways Dysfunction Syndrome (RADS) from Chlorine Gas Releasing Cleaning Agents)

  • 조광현;김승환;조영순;이한식;박준석
    • 대한임상독성학회지
    • /
    • 제3권1호
    • /
    • pp.60-62
    • /
    • 2005
  • A previously healthy 57-year-old woman with dyspnea and wheezing presented to the emergency department a few minutes after exposure to unknown gas from mixing bleach (sodium hypochlorite) and cleaning agent (hydrochloric acid) at work place. Initial physical examination revealed severe wheezing on both whole lung fields, but the chest radiograph was normal. Arterial blood gas analysis showed only moderate hypoxemia. The patient was treated with oxygen, $\beta$adrenergic bronchodilators, antihistamines and corticosteroids, after then symptoms were improved. And the patient discharged against medical advice. We report a rare case of reactive airways dysfuntion syndrome from chlorine gas exposure.

  • PDF

양극산화에 의한 다공성 알루미나 막의 기체투과 특성 (Gas Permeation Characteristics of Porous Alumina Membrane Prepared by Anodic Oxidation)

  • 함영민
    • 환경위생공학
    • /
    • 제13권3호
    • /
    • pp.72-78
    • /
    • 1998
  • For investigation into gas permeation characteristics, the porous alumina membrane with asymmetrical structure, having upper layer with 10 nanometer under of pore diameter and lower layer with 36 nanometer of pore diameter, was prepared by anodic oxidation using DC power supply of constant current mode in an aqueous solution of sulfuric acid. The aluminium plate was pre-treated with thermal oxidation, chemical polishing and electrochemical polishing before anodic oxidation. Because the pore size depended upon the electrolyte, electrolyte concentration, temperature, current density, and so on, the the membranes were prepared by controling the current density, as a very low current density for upper layer of membrane and a high current density for lower layer of membrane. By control of current quantity, the thicknesses of upper layer of membranes were about $6{\;}{\mu}m$ and the total thicknesses of membranes were about $80-90{\;}{\mu}m$. We found that the mechanism of gas permeation depended on model of the Knudsen flow for the membrane prepared at each condition.

  • PDF

고채전해질을 사용한 전류검출형 가스센서 연구 (Amperometric Gas Sensors Research of Solid Electrode)

  • 서장수;김귀열;백승철;김용주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.924-926
    • /
    • 2000
  • The nitrogen oxides, NO and NO2, abbreviated usually as NOx, emitted from combustion facilities such as power plants and automobiles are the topical air-pollutants causing acid rain and photochemical smog. In order to solve the NOx-related pollution problems effectively, we need efficient techniques to monitor NOx in the combustion exhausts and in environments. Development of solid-state electrochemical devices for detecting NOx is demonstrated based on various combination of solid electrolytes and auxiliary sensing materials. The object of this research is to develop various sensor performance for solid state amperometric sensor, and to test gas sensor performance manufactured. So we try to present a guidance for developing amperometric gas sensor. We concentrated on development of manufacturing process and performance test.

  • PDF

Biological Monitoring of Human Exposure to Volatile Halogenated Hydrocarbons Using Urinalysis with Capillary GC-ECD

  • Jung, Won-Tae;Sohn, Dong-Hun
    • Archives of Pharmacal Research
    • /
    • 제15권2호
    • /
    • pp.109-114
    • /
    • 1992
  • For the risk assessment of human exposure to volatile halogenated hydrocarbons, a dynamic purge trap/on-column cryofocusing method using capillary gas chromatograph-$^{63}Ni$ electron capture detector and thermal desorption unit was applied to analyze the free forms, metabolites of 1, 1, 2-trichloroethylene and 1, 1, 2, 2-tetrachloroethylene. The urine sample was diluted with distilled water, hydrolyzed and sealed. Then the inert gas was infused to purge out free 1, 1, 2-trichloroethylene, free 1, 1, 2, 2-tetrachloroethylene and urichloroethanol. These compounds were trapped to $Tenax^R$ / GC-gas trap device throughout clean up tube. Being undertectable to gas chromatograph directly, trichloroacetic acid was methyl esterificated and trapped in the manner above mentioned. The optimal incubation time to get best recovery of methyl ester was 4 hours at $60^circ$C. The concentrations of free volatile halogenated hydrocarbons and their metabolites in urine were obtained of free volatile halogenated hydrocarbons and their metabolites in urine were obtained from 5 healthy volunteers. This analytical method is expected to make the biological monitoring more precise and convenient.

  • PDF

Gas Permeable Membranes Composed of Carboxylated Poly(vinyl chloride) and Polyurethane

  • 임전원;김채균;김완영;정용섭;이윤식
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권6호
    • /
    • pp.672-676
    • /
    • 1999
  • Gas-Permeable polymeric membranes containing carboxyl groups which are suitable for enzyme immobilization were investigated in order to use them as gas electrode membranes in biosensors. Carboxylated polyurethane (CPU) was synthesized via a reaciton between 2,2-bis(hydroxymethyl)propionic acid as a chain extender and prepolymers prepared from polycarprolactone(Mn=2,000) and 4,4'-diphenylmethane diisocynate. It was difficult to prepared membranes from the pure CPU because of its high elasticity and cohesion. However, transparent free-standing membranes were easily prepared from the blend solution of CPU and carboxylated poly(vinyl chloride)(CPVC) in tetrahydrofuran. Both elasticity and cohesion of the CPU/CPVC membranes were decreased with increasing the content of CPVC. DSC experiment suggests that CPU and CPVC may be well mixed. Permeability coefficients for O₂and CO₂(Po₂and Pco₂)in the membranes increased as the proportion of CPU increased. The addition of dioxtyl phthalate(DOP), a plasticizer, significantly enhanced the Po₂and Pco₂which were 4,4 and 30 barrer, respectively, in the CPU/CPVC(80/20 wt/wt) membranes containing 20% of DOP at 25℃ and 100psi. Thus this type of membranes may have a potential for the use as gas electrode membranes in biosensors.

불화수소산에 의한 화학화상 2례 (Two Cases of Chemical Burns by Hydrofluoric Acid)

  • 장성원;손유동;주명돈;최우익
    • Journal of Trauma and Injury
    • /
    • 제19권2호
    • /
    • pp.173-177
    • /
    • 2006
  • Hydrofluoric acid is a colorless gas or fuming liquid with a strong, irritating odor. Hydrofluoric acid burns are uncommon; however, if severe burn occur, they caused death from systemic effects, such as fatal cardiac arrthmia. We experienced two cases of hydrofluoric acid chemical burns on digits. These patients had typical clinical features of hydrofluoric acid chemical burns, such as pulsating pain at the burn site, as well as ischemic and necrotic skin changes. The hydrofluoric acid chemical burn was confirmed by a history of exposure. Subsequently, we made a calcium gluconate gel by mixing 20% calcium gluconate, an antagonist against hydrofluoric acid, with lubricant, and we injected 10% calcium gluconate subcutaneously when they complained of pain rated at higher than 5 on the pain scale. Simultaneously, we monitored the patients' electrocardiographs and checked their serum total calcium, ionized calcium, and magnesium levels serially. Clinical presentations and the emergency management of hydrofluoric acid chemical burns were reviewed along with the current literature. These patients were discharged without any significant complications.

대전 지역 어린이 기호식품의 지방산조성 (Fatty Acid Composition of Children's Favorite Foods in Daejeon Area)

  • 장준호;전미선;이기택
    • 농업과학연구
    • /
    • 제36권2호
    • /
    • pp.211-217
    • /
    • 2009
  • 대덕구 관내 학교주변 분식점과 길거리 노점, 소규모 제과점에서 수거한 시료들의 조지방과 총 트랜스, 포화, 불포화 지방산의 함량 조사결과 어린이들이 선호하는 식품 중의 하나인 수입 비스켓류에서 100 g 당 트랜스지방산 함량이 0.05~0.83 g으로 나타났으며, 또한 포화지방산은 전체 구성 지방산 중에서 42.25~66.24%를 차지하였고 이때 100 g 당 포화지방산의 함량은 3.18~6.06 g으로 나타났다.

  • PDF

나무딸기의 화학적(化學的) 성분(成分) 조성(組成)에 관한 연구(硏究) (유리아미노산, 유기산 및 유리당) (Studies on Chemical Composition of Raspberry (Free Amino Acids, Non-Volatile Organic Acids and Sugar))

  • 주광지
    • Journal of Nutrition and Health
    • /
    • 제11권3호
    • /
    • pp.21-24
    • /
    • 1978
  • 나무딸기의 화학적 성분의 조성(組成)을 알기 위하여 유리 아미노산은 아미노산 자동분석계, 유기산은 GC 유리당은 ppC를 통하여 분석 조하여 다음과 같은 결론(結論)을 얻었다. 1. 유리아미노산은 18종(種) 발견되었으며 특히 lysine의 함량(含量)이 많았다. 필수(必須)아미노산을 고르게 함유하여 타 과실에 비하여 좋은 아미노산 조성(組成)을 이루고 있다. 2. 유기산은 citric acid, tartaric acid, maleic acid, fumaric acid가 발견 되어졌으며 일반적으로 그 함량은 적었다. 3. 당은 glucose, fructose, mannose, maltose lactose등을 함유하고 있다.

  • PDF

Rubber gaskets for fuel cells-Life time prediction through acid ageing

  • Kim, Mi-Suk;Kim, Jin-Kuk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.47-51
    • /
    • 2007
  • The present paper reports the life time prediction of Acrylonitrile-Butadiene rubber (NBR) fuel cell gasket materials as a function of operational variables like acid concentration, ageing time and temperature. Both material and accelerated acid-heat aging tests were carried out to predict the useful life of the NBR rubber gasket for use as a fuel cell stack. The acid ageing of the gasket compounds has been investigated at 120, 140 and $160^{\circ}C$, with aging times from 3 to 600 h and increasing acid ($H_2SO_4$) concentrations of 5, 6, 7 and 10 vol%. Material characteristics the gas compound such as cross-link density, tensile strength and elongation at break were studied. The hardness of the NBR rubber was found to decrease with decreasing acid concentration at both 120 and $140^{\circ}C$, but at $160^{\circ}C$ interestingly the hardness of the NBR rubber increased abruptly in a very short time at different acid concentrations. The tensile strength and elongation at break were found to decrease with increase in both the acid concentrate ion & temperature. The life time of the compounds were evaluated using the Arrhenius equation.

  • PDF