• 제목/요약/키워드: acetabulum

검색결과 44건 처리시간 0.017초

Pulmonary Thromboembolism during Acetabular Fracture Operation

  • Seo, Il;Oh, Chang-Wug;Kim, Joon-Woo;Park, Kyeong-Hyun
    • Journal of Trauma and Injury
    • /
    • 제31권2호
    • /
    • pp.72-75
    • /
    • 2018
  • Acetabular and Pelvic ring fractures are major high-energy trauma injuries and are often combined with other injuries. In particular, cause of long duration of immobilization and combined injuries, venous thromboembolism is a common complication in trauma patients with pelvic or acetabular fractures. We report a case of a fatal pulmonary thromboembolism during the acetabulum fracture operation in a 62-year-old male patient.

인공고관절 전치환술에 있어서 비구 재건 술에 관한 3차원 유한요소해석 (3-D Finite Element Analysis of Acetabular Reconstruction of THR)

  • 류제청;문무성;김규석;유명철
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.34-38
    • /
    • 1995
  • Using a 3-D finite element method (FEM), the biomechanical characteristics of a threaded truncated acetabular component and a porous coated hemispherical acetabular component were studied. The Von-Mises stress/strain patterns in the acetabulum reconstructed with these two different types of cementless acetabular cups were investigated. The geometry and dimensions of human hemi-pelvis used in the present shape modeling for finite element analysis were scanned with a 3-D laser scanner(TDS-9000, Cyberware, USA). The scanned data was numerically handled with a shape modelling software 'Pro-Engineer'. Using 19836, 16853 tetrahedral elements, respectively, the stress and displacement field of the acetabulum reconstructed with the two different types of the acetabular components were computed. While the hemi-sphere component was found to show a relatively similar stress/strain patterns to those in the normal hip, the results with the threaded cup showed a considerably different patterns from those in the normal condition. Several regions in cancellous bone near the threads and the edge of the truncated cup was found to be overstressed, especially in the superior-lateral part of the acetabulum. It was postulated that the excessive reaming-out of subchondral bone layer when the truncated cup was used can cause the presence of these overstressed regions of cancellous bone. This theoretical prediction for the implanted acetabulum appeared to consistent with the pathological observation of proximal/medial migration of the threaded truncated acetabular prostheses in the previous publications.

  • PDF

고관절을 이루는 골격의 골절 환자의 통증 감소에 대한 한의학적 치료 효과 : 후향적 관찰연구 (Effect of Korean Medicine Treatments for Pain Reduction in Patients with Hip Fracture : A Retrospective Observational Study)

  • 김남훈;오민석
    • 동의생리병리학회지
    • /
    • 제34권5호
    • /
    • pp.263-268
    • /
    • 2020
  • The aim of this study was to observe the effectiveness of Korean Medicine treatments on pain reduction of patients who were diagnosed hip fracture - Acetabulum and Proximal Femur. We reviewed the 17 patients' records who had admitted to Daejeon Korean Medical hospital and diagnosed fracture of acetabulum or proximal femur bones from January 1, 2011 to April 30, 2020 during the admission retrospectively. Statistical analysis was done using the IBM SPSS statistics 25 program. We measured Numeric Rating Scale to evaluate the treatment's efficacy. Korean Medicine treatments reduced median of Numeric Rating Scale reduced statistically significantly from 6.00 to 3.00(p<0.05). During the admission, patients didn't experience the side effects of Korean Medicine treatments. In conclusion, these results implied that Korean medicine treatments showed a positive effect on pain reduction of hip fracture patients. Further research is required to confirm the effectiveness of Korean Medicine treatments.

발달성 고관절 이형성증 또는 탈구 환자의 수술후 물리치료 (A Case Study of Physical Therapy for Developmental Dysplasia or Dislocation of the Hip After Operation)

  • 박소연
    • 한국전문물리치료학회지
    • /
    • 제6권2호
    • /
    • pp.77-86
    • /
    • 1999
  • Developmental dysplasia or dislocation of the hip is the most pronounced form of a condition in which the femoral heads tends progressively to leave the acetabulum. In the young child the variability of findings and course suggest a spectrum of conditions in which there are a number of common features: restriction of movement, particularly of abduction in flexion; shortening; and abnormal radiology, including a sloping or dysplastic acetabulum and delay in the appearance of the upper femoral epiphysis. It is vital to make the diagnosis of a congenital dislocation as soon after birth as possible. Conservative treatment with an abduction brace before the child run begins to walk is completely adequate, but after the age of 4 even surgical repositioning is difficult and after the age of 7 it is almost impossible. The aim of the study was to gain insight into the value of physical therapy of developmental dysplasia or dislocation after operation.

  • PDF

Bilateral Asymmetric Traumatic Dislocation of the Hip Joint

  • Park, Hee Gon;Yi, Hyung Suk;Han, Kyoo Hong
    • Journal of Trauma and Injury
    • /
    • 제31권1호
    • /
    • pp.43-50
    • /
    • 2018
  • Traumatic hip joint dislocations account for 2-5% of total joint dislocations. Bilateral asymmetric hip joint dislocation with anteriorly and posteriorly dislocation is an even more rare case because it was according to G. Loupasis reported in 11 cases only since 1879. We want to report 2 cases of bilateral asymmetric hip joint dislocation with unilateral acatabulum fracture which happened in our hospital. Bilateral asymmetric dislocation of hip joint accompanied by unilateral fracture of acetabulum is a very rare case so statistical verification cannot be done. However, close examinations are required at early treatment and follow-up because the patterns of dislocation and fracture of hip joint are variable and an orthopedic emergent condition and several complications may occur at both hip joints.

유한요소법을 이용한 인공 고관절의 접촉응력 해석에 관한 연구 (Contact Stress Analysis of Artificial Hip Joints Using Finite Element Method)

  • 김청균;윤종덕
    • Tribology and Lubricants
    • /
    • 제13권1호
    • /
    • pp.82-87
    • /
    • 1997
  • The modern orthopaedics frequently uses the total hip replacement in the artificial hip joint. The wear in this joint requires a re-replacement of hip joints because it is under the severe load and friction conditions. To solve these problems the previous studies have been mainly focussed on the development of new materials. The research of new materials, however, needs much time and effort since it should be experimented for its bio-compatibility, friction, and wear characteristics. To reduce the work, in this study, the finite element analysis is applied to find new combinations of bio-materials in the total hip replacement which has the excellent contact characteristics. A non-linear FEM program MARC with 5-node axisymmetric element was used for analyzing the contact stresses between the hip joints. The computed results show that in case of acetabulum UHMWP has good characteristics, in femoral head, $Al_2O_3$, and in stem, Ti6Al4V.

입체각 측정을 통한 대퇴골두에 대한 관골구 coverage 측정 (The solid angle estimation of acetabular coverage of the femoral head using 3D method)

  • 최교환;김만찬;임제탁;김선일
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.123-126
    • /
    • 1997
  • We present a method for the estimation of 3D solid angle assessment of the acetabular coverage of the femoral head in 3D space. At first, femoral head and acetabulum is segmented from the original CT scan images. The slice thickness is 1.5mm and the number of slices is usually 30-40 to cover the entire acetabulum. The superior half of the femoral head is modeled as part of a sphere. Thus, the axial cross sections of the upper half of the femoral head are also modeled as circles. A set of points from each outline image of femoral head is fitted recursively into a circle by minimizing root-mean-square (RMS) error. With these fitted circles, a center point of the femoral head model is evaluated. This is a reference point for calculating the solid angle of the acetabular inner surface. Next, the tangent lines connecting from a set of points of the acetabular edge to the center of the fitted sphere are obtained. The lines pass through the unit sphere whose center is the same as that of the femoral head. With the points on the unit sphere, we calculate area and estimate the solid angle. Based on this solid angle, the deformity of the acetabulum is analyzed. In case of normal subject, the solid angle is about 4.3 (rad) and acetabular coverage is 68%.

  • PDF

Comparison of radiographic and computed tomographic acetabular index in small-breed dogs: a preliminary study using Maltese and Shih Tzu

  • Kanthavichit, Kanokporn;Klaengkaew, Auraiwan;Thanaboonnipat, Chutimon;Darawiroj, Damri;Soontornvipart, Kumpanart;Choisunirachon, Nan
    • Journal of Veterinary Science
    • /
    • 제22권4호
    • /
    • pp.58.1-58.13
    • /
    • 2021
  • Background: The morphometry of the acetabulum is one source of information that assists in the clinical diagnosis of the hip and influences the proper selection of a prosthesis, reducing post-operative complications such as those seen in total hip replacement (THR). However, acetabular parameters in small-breed dogs are rarely reported. Objectives: To investigate acetabular parameters using radiography and computed tomography (CT) in small-breed dogs with Maltese and Shih Tzu dogs used as model breeds. Methods: Standard calibrated, extended hip radiographs and CT images were obtained. Subsequently, acetabular width (AW) in various directions was measured using radiography and CT, whereas acetabular depth (AD) was obtained by CT. Acetabular index (AI) is a ratio calculated from AD and AW. Results: The values of AW and AD were much higher in Shih Tzu than in Maltese dogs. Male Shih Tzus showed higher values of these parameters than females, while sex-based differences in most of the parameters could not be detected in Maltese. Body weight, but not age, influenced AWs and ADs. While AWs and ADs were influenced by several factors, AI was comparable among the assessed factors and between Maltese and Shih Tzu dogs (p = 0.172; 31.42 ± 1.35 and 32.60 ± 1.80, respectively). Also, AI did not vary with breed, sex, or body size. Conclusions: The obtained radiographic and CT acetabular parameters could be useful as guidelines for evaluating the acetabulum of small-breed dogs in clinical practice.

Euryhelmis squamula (Digenea: Heterophyidae) Recovered from Korean Raccoon Dog, Nyctereutes procyonoides koreensis, in Korea

  • Kim, Hyeon Cheol;Hong, Eui Ju;Ryu, Si Yun;Park, Jinho;Cho, Jeong Gon;Yu, Do Hyeon;Chae, Joon Seok;Choi, Kyoung Seong;Park, Bae Keun
    • Parasites, Hosts and Diseases
    • /
    • 제59권3호
    • /
    • pp.303-309
    • /
    • 2021
  • In this study, we intended to describe an unrecorded species of heterophyid trematode recovered from the small intestine of a Korean raccoon dog, Nyctereutes procyonoides koreensis, in Korea. A total of 13 small flukes were collected from a deceased Korean raccoon dog which was found in Chuncheon-si, Gangwon-do, Korea in May 2017. The trematode body were covered with many small spines, rectangular, broader than long, 807-1,103 ㎛ long and 1,270-1,550 ㎛ wide. Oral sucker in the anterior end slightly smaller than acetabulum. Pharynx muscular and well developed. Esophagus relatively long and sigmoid. Acetabulum small and located at median in anterior 2/5 portion. Ceca bifurcated at the anterior of genital pore and acetabulum and terminated at testis level. Testes larger, deeply lobed and located at the near of posterior end of body. Ovary small, triangular and located at the slight left of median and the anterior of left testis. Vitelline follicles dendritic and extend from the middle level of esophagus to the posterior portion of body. Eggs embryonated, operculated, small and 33-35×15-16 ㎛ in size. Based on the morphological characteristics, the small heterophyid flukes recovered from the small intestines of Korean raccoon dog, N. procyonoides koreensis, were identified as Euryhelmis squamula (Digenea: Heterophyidae). Accordingly, this species of heterophyid flukes is to be a new trematode fauna in Korea by this study.

컴퓨터 단층 촬영으로 계측한 정상 한국 성인에서의 대퇴 경부 전경사, 비구 전경사 및 합산 전경사 (Normal Korean Femoral Neck Anteversion, Acetabular Anteversion and Combined Anteversion Measured with Computed Tomography)

  • 김범수;김성태;위승명;최원락;김동석
    • 대한정형외과학회지
    • /
    • 제54권3호
    • /
    • pp.261-268
    • /
    • 2019
  • 목적: 정상 한국 성인의 컴퓨터 단층촬영 영상으로 비구 전경사, 대퇴 경부 전경사 및 합산 전경사의 값을 구한 뒤 정상 범위와 남녀간의 차이, 좌우측의 차이 및 대퇴 경부 전경사와 비구 전경사와의 상관관계를 분석하고자 하였다. 대상 및 방법: 한국 정상 성인 중 21세에서 49세 범위 내의 남자 118명과 여자 114명의 컴퓨터 단층촬영 영상을 이용하여 좌우측의 비구 전경사, 대퇴 경부 전경사를 측정하고, 합산 전경사를 계산하여 각 측정값의 평균과 표준편차를 구하고 남녀 간의 차이, 좌우측의 차이가 있는지와 비구 전경사와 대퇴 경부 전경사 간의 상관관계를 통계적으로 분석하였다. 결과: 비구의 전경사는 남자에서 우측 15.3±6.1도, 좌측 15.3±6.6도, 대퇴 경부 전경사는 Hernandez 등의 방법으로 측정한 경우 우측 5.3±7.6도, 좌측 1.5±9.2도였으며 여자에서 비구 전경사는 우측 16.8±5.4도, 좌측 16.3±5.8도, 대퇴 경부 전경사는 Hernandez 등의 방법으로 측정한 경우 우측 10.3±8.2도, 좌측 7.9±8.2도였다. 남녀 간의 차이분석 시 좌우측 모두 비구 전경사는 통계적으로 차이가 없었으며 대퇴 경부 전경사는 좌우측 모두 통계적으로 의미있는 차이가 있었다. 좌측과 우측을 비교하였을 때 비구 전경사는 차이가 없었으며 대퇴 경부 전경사는 Hernandez 등의 측정법이나 Weiner 등의 측정법 모두 좌우측 간에 통계적으로 차이가 있는 것으로 나타났다. 대퇴 경부 전경사와 비구 전경사 간의 상관관계를 보기 위하여 피어슨 상관계수를 구하였으며 그 결과 상관관계가 없는 것으로 나타났다. 결론: 남녀 간의 비구 전경사는 통계적인 차이가 없었고 대퇴 경부 전경사는 차이가 있었다. 개인별로는 좌우측 간에 대퇴 경부 전경사가 의미 있는 차이가 있었고 비구 전경사는 차이가 없었다. 대퇴 경부 전경사와 비구 전경사 간에는 상관관계가 없었다.