• Title/Summary/Keyword: accuracy-study

Search Result 16,294, Processing Time 0.046 seconds

A Study on Measurement System Accuracy of Theodolite System(IV) - A Measurement System Accuracy depending on a Distance of Scale Bar on the Distance 4m between two Theodolites (데오드라이트 시스템의 측정 정확도에 대한 연구(IV) - 시준거리 4m에서의 기준자 거리에 따른 측정 정도)

  • Yoon Yong-Sik;Lee Dong-Ju;Park Yo-Chang
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.3
    • /
    • pp.67-73
    • /
    • 2005
  • An accuracy of theodolite system may be affected by a measurement environment and a measurement distance change from theodolite to scale bar and/or targets. This study was performed for measuring an accuracy when the distance from thodolite system to scale bar was changed $2\~6m$ on the distance 4m between two theodolites. The results showed that an accuracy was ${\pm}0.025mm$ or better when the distance from theodolite system to targets was 3, 4 and 5m. According to the results, it was found that the best distance from theodolite system to scale bar was $3\~4m$ when the collimation distance was $3\~4m$.

A Study on Variation of an Accuracy Rate as the Gradient of a Pistol (총기 경사도에 따른 명중률 변화에 관한 연구)

  • Yeo, Woon-Joo;Lee, Joon-Ho;Choi, Eui-Jung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.167-172
    • /
    • 2011
  • In this paper, a study on variation of an accuracy rate as the gradient of a rifle is shown. In the a state of hostilities, a soldier is not easy to take a shot vertically against the ground. If a soldier shoots as the pistol is inclined, how the accuracy rate is changed. While the pistol is shot, the change of ballistic curve is estimated. And we also verify the accuracy rate through the firing test. Then we compare two results and present some ideas which overcome the decrease of an accuracy rate. Hereafter, it is possible to adapt in the future soldier system and expected that the accuracy rate of the conventional gun is maintained.

Do Analyst Practices and Broker Resources Affect Target Price Accuracy? An Empirical Study on Sell Side Research in an Emerging Market

  • Sayed, Samie Ahmed
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.1 no.3
    • /
    • pp.29-36
    • /
    • 2014
  • This paper attempts to measure the impact of non-financial factors including analyst practices and broker resources on performance of sell side research. Results reveal that these non-financial factors have a measurable impact on performance of target price forecasts. Number of pages written by an analyst (surrogate for analyst practice) is significantly and directly linked with target price accuracy indicating a more elaborate analyst produces better target price forecasts. Analyst compensation (surrogate for broker resource) is significantly and inversely linked with target price accuracy. Out performance by analysts working with lower paying firms is possibly associated with motivation to migrate to higher paying broking firms. The study finds that employing more number of analysts per research report has no significant impact on target price accuracy -negative coefficient indicates that team work may not result in better target price forecasts. Though insignificant, long term forecast horizon negatively affects target price accuracy while stock volatility improves target price accuracy.

A Study on Measurement Accuracy of Theodolite System( I ) - A Measurement Accuracy According to a Theodolite Collimations Distance (데오도라이트 시스템의 측정 정확도에 대한 연구( I ) - 데오도라이트 시준 거리에 따른 측정 정확도)

  • 윤용식;이동주
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.2
    • /
    • pp.61-68
    • /
    • 2004
  • A non-contact precision measurement system is a theodolite system, a laser tacker and a photogrammetry system etc. Nowadays, the system reaches to a limit of measurement accuracy required from industrial product of middle and large scale. The one of the solutions for this problem is to maximize the accuracy of the existing measurement system. According to it we performed the study far a measurement accuracy of theodolite system when the distance between two theodolites is changed 1m to 5m. We could blow that the changes of distance affect the measurement accuracy of theodolite system and that the maximum measurement accuracy is $\pm$ 0.02 mm on theodolite distance 3∼4 m.

Accuracy analysis of flood forecasting of a coupled hydrological and NWP (Numerical Weather Prediction) model

  • Nguyen, Hoang Minh;Bae, Deg-Hyo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.194-194
    • /
    • 2017
  • Flooding is one of the most serious and frequently occurred natural disaster at many regions around the world. Especially, under the climate change impact, it is more and more increasingly trend. To reduce the flood damage, flood forecast and its accuracy analysis are required. This study is conducted to analyze the accuracy of the real-time flood forecasting of a coupled meteo-hydrological model for the Han River basin, South Korea. The LDAPS (Local Data Assimilation and Prediction System) products with the spatial resolution of 1.5km and lead time of 36 hours are extracted and used as inputs for the SURR (Sejong University Rainfall-Runoff) model. Three statistical criteria consisting of CC (Corelation Coefficient), RMSE (Root Mean Square Error) and ME (Model Efficiency) are used to evaluate the performance of this couple. The results are expected that the accuracy of the flood forecasting reduces following the increase of lead time corresponding to the accuracy reduction of LDAPS rainfall. Further study is planed to improve the accuracy of the real-time flood forecasting.

  • PDF

Diagnostic Accuracy of Clinical Test for Anterior Cruciate Ligament Injury: Systematic Review

  • Deniz Yasemin;Sang-Woo Pyun;HyungSu Lee;Seong-Eun Kim;SunGyu Han;Dongyeop Lee;Ji-Heon Hong;Jae-Ho Yu;Jin-Seop Kim;Seong-gil Kim
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.3
    • /
    • pp.57-63
    • /
    • 2023
  • Purpose: The aim of this study was to conduct a systematic review of randomized controlled studies from 2012 to present that explore the diagnostic accuracy of clinical tests used for diagnosing anterior cruciate ligament (ACL) injury. Methods: Study design: Systematic review. Literature search of the PubMed and Scholar databases was conducted using keywords related to diagnostic accuracy of clinical tests for ACL injury. The PRISMA Guidelines were followed to conduct this study. The Cochrane Risk of Bias Tool was utilized to assess the quality of each included study. Results: As a result, 8 studies were included, and 6 clinical tests used in ACL tears were evaluated for diagnostic accuracy. The pivot shift test was reported as having the highest +LR (29.5) value with a sensitivity of 59% and a specificity of 98%. However, the test with the lowest -LR value was the lever test, and the values were as follows: -LR (0.08), +LR (4.7), specificity (80%), sensitivity (94%). Conclusion: In this study, it was concluded that a single clinical test is not sufficient to determine the presence of ACL injury. Test combinations have a higher diagnostic accuracy than a single test. In this study, the accuracy of the clinical tests was examined without considering the amount of ACL rupture and acute-chronic condition. Further research is required to examine the impact of these two factors on diagnostic accuracy of clinical test.

The Accuracy analysis of a RFID-based Positioning System with Kalman-filter (칼만필터를 적용한 RFID-기반 위치결정 시스템의 정확도 분석)

  • Heo, Joon;Kim, Jung-Hwan;Sohn, Hong-Gyoo;Yun, Kong-Hyun
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2007.04a
    • /
    • pp.447-450
    • /
    • 2007
  • Positioning technology for moving object is an important and essential component of ubiquitous. Also RFID(Radio Frequency IDentification) is a core technology of ubiquitous wireless communication. In this study we adapted kalman-filter theory to RFID-based Positioning System in order to trace a time-variant moving object and verify the positioning accuracy using RMSE (Roong technology for moving object is an important and essential component of ubiquitous Mean Square Error). The purpose of this study is to verify an effect of kalman-filter on the positioning accuracy and to analyze what does each design factor have an effect on the positioning accuracy by means of simulations and to suggest a standard of optimal design factor of a RFID-based Positioning System. From the results of simulations, Kalman-filer improved the positioning accuracy remarkably; the detection range of RFID tag is not a determining factor. The smaller standard deviation of detection range improves the positioning accuracy. However it accompanies a smaller fluctuation of the positioning accuracy. The larger detection rate of RFID tag yields the smaller fluctuation in the positioning accuracy and has more stable system and improves the positioning accuracy;

  • PDF

A Study on the Machining Accuracy according to Vibration and Unbalance Decrease in Rotational Speed Domains of High Precision Machine Tools (정밀 공작기계의 회전 영역별 진동 및 불평형량 감소에 따른 가공 정밀도 영향에 관한 연구)

  • Son, Deok-Soo;Kim, Sang-Hwa;Park, Il-Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.2
    • /
    • pp.121-126
    • /
    • 2013
  • Precision machine tools for high dignity cutting are needed for efforts to improve machining accuracy. However, there are many factors to improve machining accuracy. This study investigated how machining accuracy changes when variation and unbalance amount in rotational speed domain is decreased. Machining accuracy of initial machine tools depends on manufacturing and assembly of parts such as bearing. And then, vibration and noise vary with volume of unbalance amount when it is rotation, so it effects unbalance amount. Also vibration and noise increased by unbalance shorten spindle's life and it especially makes worse boring accuracy. Therefore, this study studied the change of roundness and cylindricity of workpiece when it decreases variation and unbalance in rotational speed domain.

A Study on Forecast Accuracies by the Localized Land Forecast Areas over South Korea (육상 국지 예보 구역의 예보 정확도에 관한 연구)

  • Park, Chang-Yong;Choi, Young-Eun;Kim, Seung-Bae
    • Journal of the Korean Geographical Society
    • /
    • v.42 no.1 s.118
    • /
    • pp.1-14
    • /
    • 2007
  • This study aimed to evaluate weather forecast accuracies of minimum temperature, maximum temperature, precipitation and sky cover by the localized land forecast areas over South Korea Average forecast accuracy score of precipitation was the lowest while that of sky cover was the highest during the study period Overall forecast accuracy scores for Gangwon-do was the lowest while those for Gyeongsangnam-do and Gyeongsangbuk-do were higher than other areas. The frequencies of perfect forecast(eight points) by seasons, were the highest during winter and the lowest during summer. pressure pattern analyses for days when forecast accuracy scores were poor, showed that precipitation forecast accuracy scores were lower due to the movement of the stationary fronts during summers. When continental polar air masses expanded, forecast accuracy of temperature became greatly lower during autumns and winters As the migratory anticyclone pattern rapidly moved, forecast accuracy became lower during springs and autumns. Forecast accuracies were compared by wind directions at 850hPa for the Young-dong region where forecast accuracy was the lowest. Forecast accuracy scores on minimum and maximum temperatures were low when winds were westerlies and forecast accuracy scores of precipitation were low when winds were easterlies.

A Study on Measurement Accuracy of Theodolite System(III) - A Measurement System Accuracy depending on a Distance of Scale Bar on the Distance 3 m between two Theodolites (데오드라이트 시스템의 측정 정확도에 대한 연구(III) - 시준거리 3 m에서 기준자 거리에 따른 측정 정도)

  • Yoon Yong Sik;Lee Dong Ju;Yoon In Jin
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.2
    • /
    • pp.48-54
    • /
    • 2005
  • The theodolite system consists of two theodolites, a scale bar and a target bu. A measurement accuracy of theodolite system is affected by a measurement distance of each equipment. This study was performed fir measuring an accuracy when the distance from theodolite to scale bar was changed 2~ 6 m on two theodolites distance 3 a The results showed thai the measurement accuracy could be $\pm$0.021 mm when the distance from theodolite to target was 2,3 and 6 n Specially, it was found that the maximum measurement accuracy was 10.017mm on theodolite collimation distance 3m and the distance 4 m of the theodolite and scale bar.