• Title/Summary/Keyword: accuracy-study

Search Result 16,294, Processing Time 0.04 seconds

Analysis and verification of vitamin B12 in animal foods for update of national standard food composition table (국가표준식품성분표 개정을 위한 동물성 식품 비타민 B12 분석 및 검증)

  • Jeong, Yon Na;Park, Su-Jin;Lee, Sang Hoon;Choi, Youngmin;Choi, Kap Seong;Chun, Jiyeon
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.4
    • /
    • pp.317-324
    • /
    • 2020
  • In order to create the national food nutrient database, a total of 41 animal foods (ham, seafood, edible insects and eggs) were analyzed for their vitamin B12 content and the applied immunoaffinity-HPLC was verified. Ham vitamin B12 contents were 0.30-0.65 ㎍/100 g. Seafood showed relatively high vitamin B12 level, where the values of fermented clam were the highest (26.80 ㎍/100 g) followed by fermented pollack roe. Vitamin B12 was not detected in silkworm pupae and beetles, while relatively high levels were found in the two-spotted cricket imago (6.70 ㎍/100 g). Chicken and quail egg yolk had roughly 100- and 30-times higher vitamin B12 levels as compared to their egg white. Vitamin B12 contents in quail and chicken eggs were significantly enhanced by boiling (p<0.05). Results based on accuracy (97-102% recovery) and precision (<5% RSD) indicate that this study provides reliable vitamin B12 information on animal foods consumed in Korea.

Study on Labeling Efficiency of $^{99m}Tc$-HMPAO ($^{99m}Tc$-HMPAO 표지효율에 대한 고찰)

  • Hyeon, Jun Ho;Lim, Hyeon Jin;Kim, Ha Kyun;Cho, Seong Uk;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.131-134
    • /
    • 2012
  • Purpose : The labeling efficiency of radiopharmaceuticals in nuclear medicine is important in terms of accuracy and reliability of the examination. Usually $^{99m}Tc$-HMPAO used for brain SPECT scan is chemically unstable since lots of impurities are existing. Therefore, occurrence of loss of labeling efficiency is easy to appear. In this paper, labeling and use of $^{99m}Tc$-HMPAO should be helpful through experiments on factors affecting the labeling efficiency of $^{99m}Tc$-HMPAO. Materials and Methods : Domestic HMPAO vials (Dong-A) used for brain SPECT scan were tested. Domestic Samyeong Generator 55.5 GBq (1,500 mCi), TLC measurement sets (ITLC-SG, butanone, saline, TLC chamber) and radio-TLC scanner (Advantest, Bioscan) were used. In the first experiment, after eluting generator at 1, 8, 16, 24, 28 hours apart, each eluted $^{99m}Tc$-pertechnetate were labeled with HMPAO and the labeling efficiency was measured. In the second experiment, after eluting $^{99m}Tc$-pertechnetate from a generator, $^{99m}Tc$-pertechnetate was drawn at 0, 1, 3, 6 hours. And each drawn $^{99m}Tc$-pertechnetate were labeled with HMPAO for measuring labeling efficiency. In the third experiment, labeling efficiency was measured at 0, 0.5, 3, 5, 7 hours after labeling $^{99m}Tc$-HMPAO. Results : In the first experiment, measured values were appeared 95.05, 94.64, 94.94, 95.64, 96.76% in passing order of time. In the second experiment, measured values were appeared 94.38, 94.23, 93.26, 91.03% in passing order of time. In the third experiment, measured values were appeared 95.76, 94.17, 88.19, 83.6, 76.86% in passing order of time. Conclusion : In the first experiment of this paper, labeling efficiency of $^{99m}Tc$-HMPAO labeled with $^{99m}Tc$-pertechnetate eluted after 24 hours from first elution. Additional experiments will be needed to discuss for usability. In the second experiment, the labeling efficiency was slightly decreased in chronological order, but it was measured higher than 90%. Also, additional experiments will be needed to discuss for usability. In the third experiment, the labeling efficiency was decreased considerably. Especially, within 3 hours after the labeling is recommended to use $^{99m}Tc$-HMPAO

  • PDF

Evaluation of Average CT to Reduce the Artifact in PET/CT (PET/CT 검사에서 호흡에 따른 인공산물을 줄이기 위한 Average CT의 유용성)

  • Kim, Jung-Sun;Nam, Ki-Pyo;Park, Seung-Yong;Ryu, Jae-Kwang;Cha, Min-Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.3-7
    • /
    • 2010
  • Purpose: The usefulness of Positron Emission Tomography (PET) images in diagnosis, staging, recurrent and treatment response evaluation has already been known. However, tumors which are small size, located in lower lobe of lung or upper lobe of liver are shown misalignment, distortion and different Standard Uptake Value (SUV) by respiration in PET images. Therefore, if radiotherapy based on normal respiration, it may cause low treatment response or more side effects because targets which had to treat, out of treat range or over dose to normal tissue. The purpose of this study is to evaluate attenuation-correction with Average CT (ACT) for more accuracy SUV measurement and minimize artifact by respiration. Materials and Methods: 13 patients, who had tumors which are around the diaphragm, underwent ACT scan after Helical CT (HCT) scan with PET/CT (Discovery DSTE 8; GE Healthcare). We quantified the differences between attenuation corrected image with HCT and attenuation corrected image with ACT in artifact size and maximum SUV ($SUV_{max}$). Artifacts were evaluated by measurement of the curved photogenic area in the lower thorax of the PET images for all patients. $SUV_{max}$ was measured separately at the primary tumors. Analysis program was Advantage Workstation v4.3 (GE Healthcare). Patients were injected with 7.4 MBq (0.2 $mC_i$) per kg of $^{18}F$-FDG and scanned 1 hour after injection. The PET acquisition was 3 minute per bed. Results: Significantly lower artifact were observed in PET/ACT images than in PET/HCT images (below-thoracic artifacts caused by under corrected $1.5{\pm}3.5$ cm vs. $13.4{\pm}4.2$ cm). Significantly higher $SUV_{max}$ were noted in PET/ACT images than in PET/HCT images in the primary tumor. Compared with PET/HCT images, $SUV_{max}$ in PET/ACT images were higher by $5.3{\pm}3.9%$ (mean value) tumor. The highest difference was observed in Lower lobe of lung (7.7 to 8.7; 13%). Conclusion: Due to its significantly reduced artifacts in lower thoracic, attenuation corrected image with ACT images provided more reliable $SUV_{max}$ and may be helpful in monitoring treatment response. Moreover, ACT can separate upper lobe of liver and lower lobe of lung, it may be helpful in interpretation. ACT will be clinically useful, considering increased dose caused by ACT scan and adapt.

  • PDF

Real-time Reverse Transcription Polymerase Chain Reaction Using Total RNA Extracted from Nasopharyngeal Aspirates for Detection of Pneumococcal Carriage in Children (소아에서 폐렴구균 집락률 측정을 위해 비인두 흡인 물의 총 RNA를 이용한 실시간 중합효소 연쇄반응법)

  • Kim, Young Kwang;Lee, Kyoung Hoon;Yun, Ki Wook;Lee, Mi Kyung;Lim, In Seok
    • Pediatric Infection and Vaccine
    • /
    • v.23 no.3
    • /
    • pp.194-201
    • /
    • 2016
  • Purpose: Monitoring pneumococcal carriage rates is important. We developed and evaluated the accuracy of a real-time reverse transcription polymerase chain reaction (RT-PCR) protocol for the detection of Streptococcus pneumoniae. Methods: In October 2014, 157 nasopharyngeal aspirates were collected from patients aged <18 years admitted to Chung-Ang University Hospital. We developed and evaluated a real-time PCR method for detecting S. pneumoniae by comparing culture findings with the results of the real-time PCR using genomic DNA (gDNA). Of 157 samples, 20 specimens were analyzed in order to compare the results of cultures, real-time PCR, and real-time RT-PCR. Results: The concordance rate between culture findings and the results of real-time PCR was 0.922 (P<0.01, Fisher exact test). The 133 culture-negative samples were confirmed to be negative for S. pneumoniae using real-time PCR. Of the remaining 24 culture-positive samples, 21 were identified as S. pneumonia -positive using real-time PCR. The results of real-time RT-PCR and real-time PCR from 20 specimens were consistent with culture findings for all S. pneumoniae -positive samples except one. Culture and real-time RT-PCR required 26.5 and 4.5 hours to perform, respectively. Conclusions: This study established a real-time RT-PCR method for the detection of pneumococcal carriage in the nasopharynx. Real-time RT-PCR is an accurate, convenient, and time-saving method; therefore, it may be useful for collecting epidemiologic data regarding pneumococcal carriage in children.

Operational Ship Monitoring Based on Multi-platforms (Satellite, UAV, HF Radar, AIS) (다중 플랫폼(위성, 무인기, AIS, HF 레이더)에 기반한 시나리오별 선박탐지 모니터링)

  • Kim, Sang-Wan;Kim, Donghan;Lee, Yoon-Kyung;Lee, Impyeong;Lee, Sangho;Kim, Junghoon;Kim, Keunyong;Ryu, Joo-Hyung
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_2
    • /
    • pp.379-399
    • /
    • 2020
  • The detection of illegal ship is one of the key factors in building a marine surveillance system. Effective marine surveillance requires the means for continuous monitoring over a wide area. In this study, the possibility of ship detection monitoring based on satellite SAR, HF radar, UAV and AIS integration was investigated. Considering the characteristics of time and spatial resolution for each platform, the ship monitoring scenario consisted of a regular surveillance system using HFR data and AIS data, and an event monitoring system using satellites and UAVs. The regular surveillance system still has limitations in detecting a small ship and accuracy due to the low spatial resolution of HF radar data. However, the event monitoring system using satellite SAR data effectively detects illegal ships using AIS data, and the ship speed and heading direction estimated from SAR images or ship tracking information using HF radar data can be used as the main information for the transition to UAV monitoring. For the validation of monitoring scenario, a comprehensive field experiment was conducted from June 25 to June 26, 2019, at the west side of Hongwon Port in Seocheon. KOMPSAT-5 SAR images, UAV data, HF radar data and AIS data were successfully collected and analyzed by applying each developed algorithm. The developed system will be the basis for the regular and event ship monitoring scenarios as well as the visualization of data and analysis results collected from multiple platforms.

The Effects of Sight Alignment Method on Pistol Shooting Records of Security Guard (경호요원 권총사격시 조준선정렬방식과 기록변화와의 관계)

  • Lee, Sang-Chul;Shin, Seung-Cheol
    • Korean Security Journal
    • /
    • no.14
    • /
    • pp.367-388
    • /
    • 2007
  • Some of individuals working at various fields of security guard are given the legal right to use a gun to cope with expected risks and crimes. Not only in Korea but also throughout the world, a pistol is being used as a device for the workers of security guard such as the army, the police and intelligence agencies to keep the law and social order. A pistol, which is regarded as the last safety measure of security guard, is easy to carry but, because of its short barrel for high portability, its hit ratio and long-range shooting performance are much lower than ordinary guns. Despite such weak points, a pistol can be a great tool because of its high portability and if the users make steady efforts to improve their skills and, for this reason, it has been being used widely until now. National agency workers' pistol shooting skills depend on several important factors, but for the fast and accurate shooting, the mot important factor is how to aim at the target. Because it takes a relatively longer time to align the sight on the target, the change of the sight alignment method is expected to improve pistol shooting skills a lot. In Korea, however, most of national agency training centers teach the basic aiming method that crosses the foresight and the backsight and aligns the crossing to the target. That is, they teach the sight alignment method for fixed targets. Some agencies in Korea and foreign countries that have used guns more frequently and longer than us are teaching different sight alignment methods as well. Representative ones of them are aiming only with the foresight and pointing shooting. These aiming methods are expected to produce good results against moving targets. While the basic sight alignment method has to cross the foresight and the backsight and then to align the crossing to the target, so takes a longer time than other aiming methods, the other two aiming methods are expected to be effective in fields where both swiftness and accuracy are require. Because domestic agencies are teaching mainly the basic sight alignment method, the present study purposed to examine the effects of different aiming methods on shooting records and ultimately to contribute to national agency workers' operation. For this purpose, we selected 20 policemen from local police commandos under the National Police Agency who were accustomed to pistol shooting and measured their pistol shooting. According to the results, the pointed shooting method showed the best record in 5m short.range shooting. As to hit ratio in 15m shooting, which is relatively long.range for pistol shooting, the basic aiming method showed the best record, but the results of statistical analysis showed that pointed shooting is most superior. Of course, the results were obtained from a group who were used to and skillful in pistol shooting, but they are considered meaningful in that all the police and national agency workers should have such high shooting skills.

  • PDF

Estimation of Groundwater Recharge by Considering Runoff Process and Groundwater Level Variation in Watershed (유역 유출과정과 지하수위 변동을 고려한 분포형 지하수 함양량 산정방안)

  • Chung, Il-Moon;Kim, Nam-Won;Lee, Jeong-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.5
    • /
    • pp.19-32
    • /
    • 2007
  • In Korea, there have been various methods of estimating groundwater recharge which generally can be subdivided into three types: baseflow separation method by means of groundwater recession curve, water budget analysis based on lumped conceptual model in watershed, and water table fluctuation method (WTF) by using the data from groundwater monitoring wells. However, groundwater recharge rate shows the spatial-temporal variability due to climatic condition, land use and hydrogeological heterogeneity, so these methods have various limits to deal with these characteristics. To overcome these limitations, we present a new method of estimating recharge based on water balance components from the SWAT-MODFLOW which is an integrated surface-ground water model. Groundwater levels in the interest area close to the stream have dynamics similar to stream flow, whereas levels further upslope respond to precipitation with a delay. As these behaviours are related to the physical process of recharge, it is needed to account for the time delay in aquifer recharge once the water exits the soil profile to represent these features. In SWAT, a single linear reservoir storage module with an exponential decay weighting function is used to compute the recharge from soil to aquifer on a given day. However, this module has some limitations expressing recharge variation when the delay time is too long and transient recharge trend does not match to the groundwater table time series, the multi-reservoir storage routing module which represents more realistic time delay through vadose zone is newly suggested in this study. In this module, the parameter related to the delay time should be optimized by checking the correlation between simulated recharge and observed groundwater levels. The final step of this procedure is to compare simulated groundwater table with observed one as well as to compare simulated watershed runoff with observed one. This method is applied to Mihocheon watershed in Korea for the purpose of testing the procedure of proper estimation of spatio-temporal groundwater recharge distribution. As the newly suggested method of estimating recharge has the advantages of effectiveness of watershed model as well as the accuracy of WTF method, the estimated daily recharge rate would be an advanced quantity reflecting the heterogeneity of hydrogeology, climatic condition, land use as well as physical behaviour of water in soil layers and aquifers.

Compact Orthomode Transducer for Field Experiments of Radar Backscatter at L-band (L-밴드 대역 레이더 후방 산란 측정용 소형 직교 모드 변환기)

  • Hwang, Ji-Hwan;Kwon, Soon-Gu;Joo, Jeong-Myeong;Oh, Yi-Sok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.7
    • /
    • pp.711-719
    • /
    • 2011
  • A study of miniaturization of an L-band orthomode transducer(OMT) for field experiments of radar backscatter is presented in this paper. The proposed OMT is not required the additional waveguide taper structures to connect with a standard adaptor by the newly designed junction structure which bases on a waveguide taper. Total length of the OMT for L-band is about 1.2 ${\lambda}_o$(310 mm) and it's a size of 60 % of the existing OMTs. And, to increase the matching and isolation performances of each polarization, two conducting posts are inserted. The bandwidth of 420 MHz and the isolation level of about 40 dB are measured in the operating frequency. The L-band scatterometer consisting of the manufactured OMT, a horn-antenna and network analyzer(Agilent 8753E) was used STCT and 2DTST to analysis the measurement accuracy of radar backscatter. The full-polarimetric RCSs of test-target, 55 cm trihedral corner reflector, measured by the calibrated scatterometer have errors of -0.2 dB and 0.25 dB for vv-/hh-polarization, respectively. The effective isolation level is about 35.8 dB in the operating frequency. Then, the horn-antenna used to measure has the length of 300 mm, the aperture size of $450{\times}450\;mm^2$, and HPBWs of $29.5^{\circ}$ and $36.5^{\circ}$ on the principle E-/H-planes.

A Review on Ultimate Lateral Capacity Prediction of Rigid Drilled Shafts Installed in Sand (사질토에 설치된 강성현장타설말뚝의 극한수평지지력 예측에 관한 재고)

  • Cho Nam Jun;Kulhawy F.H
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.2
    • /
    • pp.113-120
    • /
    • 2005
  • An understanding of soil-structure interaction is the key to rational and economical design for laterally loaded drilled shafts. It is very difficult to formulate the ultimate lateral capacity into a general equation because of the inherent soil nonlincarity, nonhomogeneity, and complexity enhanced by the three dimensional and asymmetric nature of the problem though extensive research works on the behavior of deep foundations subjected to lateral loads have been conducted for several decades. This study reviews the four most well known methods (i.e., Reese, Broms, Hansen, and Davidson) among many design methods according to the specific site conditions, the drilled shaft geometric characteristics (D/B ratios), and the loading conditions. And the hyperbolic lateral capacities (H$_h$) interpreted by the hyperbolic transformation of the load-displacement curves obtained from model tests carried out as a part of this research have been compared with the ultimate lateral capacities (Hu) predicted by the four methods. The H$_u$ / H$_h$ ratios from Reese's and Hansen's methods are 0.966 and 1.015, respectively, which shows both the two methods yield results very close to the test results. Whereas the H$_u$ predicted by Davidson's method is larger than H$_h$ by about $30\%$, the C.0.V. of the predicted lateral capacities by Davidson is the smallest among the four. Broms' method, the simplest among the few methods, gives H$_u$ / H$_h$ : 0.896, which estimates the ultimate lateral capacity smaller than the others because some other resisting sources against lateral loading are neglected in this method. But it results in one of the most reliable methods with the smallest S.D. in predicting the ultimate lateral capacity. Conclusively, none of the four can be superior to the others in a sense of the accuracy of predicting the ultimate lateral capacity. Also, regardless of how sophisticated or complicated the calculating procedures are, the reliability in the lateral capacity predictions seems to be a different issue.

Shade comparative analysis of natural tooth measured by visual and spectrophotometric methods (육안과 분광 측정기를 이용한 자연 치아의 색조비교분석)

  • Kim, Bum-Suk;Shin, Soo-Yeon;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.443-454
    • /
    • 2008
  • Statement of problem: A clinically successful color match is one of the important factor to get an esthetic dental restoration. Dental shade guides are commonly used to evaluate tooth color in restorative procedure. But numerous reports have indicated that common shade guides do not provide sufficient spectral coverage of the natural tooth colors. To address issues associated with the shade guide, distinct avenues have been pursued objective spectrophotometric / colorimetric assessment. Purpose: This study compared the accuracy of tooth color selection of spectrophotometer with that of human visual determination. Three main factors were investigated, namely, the effect of light, the individual variation and the experience of the observer. Material and methods: At the first experiment, on ten patients, one operator independently selected the best matching shade to the unrestored maxillary central incisor, using a Vita Classical Shade Guide in the morning, at noon and in the afternoon. The same teeth were measured by means of a reflectance spectrophotometer. At the second experiment, on ten patients, ten operators (5 experts, 5 novices) selected and measured by the same method above at noon. At the third experiment, the results of the second experiment were divided into two groups, expert and novice, and analyzed. Results: 1. There was significant difference between visual and spectrophotometric assessment (mean ${\Delta}E$ values) in experiment 1, 2, 3 (P < .05). 2. There was no significant difference between experts and novices group, when comparing with each visual and spectrophotometric assessment (mean ${\Delta}E$ values). Conclusion: Spectrophotometer could be used to analyze the shade of natural tooth objectively. Thereby, this method offers the potential tominimize considerably the need for corrections or even remakesafter intraoral try-in of restoration. Furthermore, to achieve its advantage, both the shade-matching environment and communication between dentist and technician should be optimized with use of visual and instrumental shade-matching systems.