• 제목/요약/키워드: accuracy standard

검색결과 2,399건 처리시간 0.029초

포구속도 계측 시스템의 정확도 분석 (An Analysis of the Accuracy of Muzzle Velocity Measurement System)

  • 최주호;황의성;박원우;홍성수;유준
    • 제어로봇시스템학회논문지
    • /
    • 제5권1호
    • /
    • pp.88-94
    • /
    • 1999
  • This paper presents an accuracy evaluation method for muzzle velocity measurement systems. Among various measuring techniques, the solenoid coil scheme and the doppler radar scheme are considered due to their popularity in applications. The error sources are first identified and their effects on the accuracy of the measuring systems are quantified using mathmatical equations. The theoritic accuracy limits are then verified through comparison with experimental results. From the accuracy point of view, they turn out to be standard velocity measuring systems.

  • PDF

머시닝 센터에서 하중이 위치결정정밀도에 미치는 영향 (The effect on the position precision by load in M.C.)

  • 이승수
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 춘계학술대회 논문집
    • /
    • pp.143-147
    • /
    • 1998
  • As the accuracy of manufactured goods needed high-accuracy processing has made the efficiency of NC and measurment technology develop, the innovation of machine tools has influence the development of the semi-conductor and optical technology. We can mention that a traction role of the acceleration for the development like that depends on the development of the measurement technics - Stylus instrument method, STM, SEM, Laser interferometer method - which are used for measuring the movement accuracy of machine tools. The movement error factors in movement accuracy are expressed as yaw, roll, and pitch etc. Machining center has 21 movement error factors including of 3 axies joint errors because that has 3 axies and has been measured as the standard of the unloaded condition until now inspite of getting static, dynamic, and servo-gain errors in the case of expending the error range. Therefore, this study tries to measure position accuracy according to loading on the X-Y table of the machining center.

  • PDF

하중에 의한 위치결정오차와 테이블 처짐에 관한 연구 (A Study on the Positioning Accuracy and table Deflection by Load)

  • 전언찬
    • 한국생산제조학회지
    • /
    • 제8권6호
    • /
    • pp.98-104
    • /
    • 1999
  • As the accuracy of manufactured goods needed high accuracy processing has made the efficiency of NC and measurement technology development, the innovation of machine tools has influence the development of the semi-conductor and optical technology. The movement errors can be expressed in terms of yaw, roll an pitch etc. In the case of expanding the error range, static, dynamic and servo gain errors can be included. Machining center might have twenty-one movement errs including three types of joint errors. Those errors have been measured on the condition of just loading of standard table. Regarding these measuring methods, the mechanical compliance of the structure has not been considered. In this paper, therefor, the influences of the additional load on the positioning accuracy are investigated. The results and the techniques proposed in this study can be considered very effective and useful to compensate more correctly the positioning motion.

  • PDF

실시간 앙상블 가뭄전망정보 생산 체계 구축 및 평가 (Development & Evaluation of Real-time Ensemble Drought Prediction System)

  • 배덕효;안중배;김현경;김헌애;손경환;조세라;정의석
    • 대기
    • /
    • 제23권1호
    • /
    • pp.113-121
    • /
    • 2013
  • The objective of this study is to develop and evaluate the system to produce the real-time ensemble drought prediction data. Ensemble drought prediction consists of 3 processes (meteorological outlook using the multi-initial conditions, hydrological analysis and drought index calculation) therefore, more processing time and data is required than that of single member. For ensemble drought prediction, data process time is optimized and hardware of existing system is upgraded. Ensemble drought data is estimated for year 2012 and to evaluate the accuracy of drought prediction data by using ROC (Relative Operating Characteristics) analysis. We obtained 5 ensembles as optimal number and predicted drought condition for every tenth day i.e. 5th, 15th and 25th of each month. The drought indices used are SPI (Standard Precipitation Index), SRI (Standard Runoff Index), SSI (Standard Soil moisture Index). Drought conditions were determined based on results obtained for each ensemble member. Overall the results showed higher accuracy using ensemble members as compared to single. The ROC score of SRI and SSI showed significant improvement in drought period however SPI was higher in the demise period. The proposed ensemble drought prediction system can be contributed to drought forecasting techniques in Korea.

pH 측정 시스템의 표준화에 관한 연구 (Studies on the Standardization of pH Measurement System)

  • 이화심;김명수;김진복;오상협
    • 대한화학회지
    • /
    • 제42권4호
    • /
    • pp.432-442
    • /
    • 1998
  • $pH=-loga_H$ 정의에서 pH는 단일 이온의 활동도항을 포함하므로 단지 측정의 방법만으로는 결정되어질 수 없고 근사법을 필요로 한다. 근사법에 의한 pH 측정은 수소전극과 은/염화은 전극을 사용한 액간 접촉이 없는 cell의 기전력 측정으로부터 이루어지는 방법이며, 이 과정을 통해 pH 값이 인증된 pH의 일차 표준 물질을 얻을 수 있다. 일반적인 pH 미터와 전극을 검정하는 데에는 인증된 pH 값을 가지는 표준 완충용액을 사용하므로 표준 완충용액의 pH 값 정혹도는 실제 측정된 pH 값의 실효성을 제한할 수 있다. 본 연구에서는 정확한 pH의 측정을 위해서 pH 값을 인증할 수 있는 시스템을 구축하기 위한 제반의 연구를 수행하였으며, 이를 토대로 pH 1.6∼12.5의 범위에 해당하는 완충용액의 pH를 0.005 pH 단위 이내의 불확도로 인증하였다.

  • PDF

디지털 트윈국토 건물 데이터 품질 표준 개발을 위한 항목 도출에 관한 연구 (A Study on the Derivation of Items for Development of Data Quality Standard for 3D Building Data in National Digital Twin)

  • 김병선;이희석;홍상기
    • 지적과 국토정보
    • /
    • 제52권1호
    • /
    • pp.37-55
    • /
    • 2022
  • 본 연구는 디지털 트윈국토 건물 데이터 품질 표준을 개발하기 위한 품질 항목 모델을 제시하는데 목적이 있다. 이를 위해 3차원 공간정보 오류의 특징과 품질 표준 필요성에 대해 도출하였으며, 디지털 트윈국토 건물 품질 개발에 필요한 데이터 모델 표준과 공간정보 품질 표준에 대해 분석하였다. 이러한 내용을 토대로 디지털 트윈국토 건물 데이터의 품질 평가 범위, 품질 표준 확장 요소(기하 무결성, 기하 충실도, 위치 정확성, 시맨틱 분류 정확성) 및 품질 항목 모델(안)을 제시하였다. 본 연구에서 제안한 디지털 트윈국토 건물 품질 항목모델은 디지털 트윈국토 품질 표준 개발은 물론 이와 관련된 다양한 디지털 트윈국토 공간정보표준 개발에 기여할 것으로 판단된다.

가정용 전자식 혈압계의 정확도에 대한 임상적 평가 (Clinical Evaluation of the Accuracy of Electronic Home Blood Pressure Measuring Devices)

  • 추진아
    • 기본간호학회지
    • /
    • 제9권1호
    • /
    • pp.101-112
    • /
    • 2002
  • Purpose: This study evaluated the accuracy of electronic devices compared with mercury sphygmomanometer. Of 132 outpatients with electronic devices. 77 who possessed oscillometric cuff devices participated in this study. Method: When the blood pressure was measured, all electronic devices were connected by means of a Y-connector to a mercury sphygmomanometer. Using the simultaneous same arm approach, each comparison was carried out three times at 2-minute intervals. Results: Compared with the mercury sphygmomanometer, the electronic devices underestimated systolic and diastolic blood pressure, respectively by $4.0{\pm}5.8mmHg$ and $2.5{\pm}67mmHg$, which satisfies the standard error range of the American Association for the Advancement of Medical Instrumentation. According to the British Hypertension Society criteria, these differences achieved C grade for both systolic and diastolic pressure. For the graphical analysis, the differences had a tendency to fulfill the permitted error limits in both diastolic and systolic blood pressure. Moreover, the purchase duration was not correlated with the accuracy of electronic devices. Conclusion: These results indicate that difference in blood pressure between electronic devices and mercury sphygmomanometer is within the standard error. Therefore, electronic blood pressure measuring devices may be useful for therapeutic self-management of hypertension.

  • PDF

비파괴검사 전용 시뮬레이터를 이용한 와전류검사 신호 시뮬레이션 (Simulation of Eddy Current Testing Signals Using Simulation Software Dedicated to Nondestructive Testing)

  • 이태훈;조찬희;이희종
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.75-81
    • /
    • 2014
  • A simulation of eddy current testing has been utilized for predicting the signal characteristics to the various defects and developing the probes. Especially, CIVA which is a simulation tool dedicated to nondestructive testing has a good accuracy and speed, and provides a three-dimensional graphical user interface for improved visualization and familiar data displays consistent with NDE technique. Although internal validations have been performed by the CIVA software development specialists, an independent validation study is necessary for the accuracy assessment of the software prior to practical use. For this purpose, in this study, eddy current testing signals of ASME FBH calibration standard tube for bobbin probe were simulated using CIVA and the results were compared to the experimental inspected signals based on the relationship between each flaw signal in terms of amplitude and phase, and the shape of the Lissajous curve. And then we verified the accuracy of the simulated signals and the possible range for simulation. Overall, there is a good qualitative agreement between the CIVA simulated and experimental results in the absolute and differential modes at the two inspection frequencies.

The Development of a Cuff for the Accuracy Enhancement of the Sphygmomanometer

  • Kim, Won-Ki;Shin, Ki-Young;Mun, Joung-Hwan
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제7권2호
    • /
    • pp.30-35
    • /
    • 2006
  • The purpose of this study is to develop a new cuff to improve the accuracy of blood pressure measurement, and to evaluate the performance of the developed system. We added a small bladder to the normal cuff, which we refer to as the double bladder system. The system that we developed for blood pressure measurement was based on the oscillometric method using a double bladder. This system was developed in order to reduce the oscillation noise and to amplify the signal of pure blood pressure. An oscillometric signal database based on the developed system was evaluated according to the ANSI/AAMI/SP10-1992 standard. The correlation coefficients between the cuff of the double bladder and the normal cuff were 0.98 for systolic pressure and 0.94 for diastolic pressure. The mean differences and the standard deviations between the average blood pressure obtained from a mercury manometer and that obtained from an automated sphygmomanometer were -0.7mmHg and 4.9mmHg for systolic, and -1.4mmHg and 5.4mmHg for diastolic pressure. We conclude that the proposed double bladder-based cuff system improves the accuracy of oscillometric blood pressure measurement. The developed system reduces the range of error by about $44{\sim}62%$ for systolic pressure and about $6{\sim}21%$ for diastolic pressure compared to the most recently developed, commercially available sphygmomanometers.

부산지방에서의 오메가전파의 전파특성과 측정위치의 정도에 관하여 (Accuracy of the Position Fix and the Propagational Characteristic of Omega Radio Wave at Busan)

  • 안장영;신형일
    • 수산해양기술연구
    • /
    • 제17권1호
    • /
    • pp.19-28
    • /
    • 1981
  • Accuracy of the position fix obtained by navigation with Omega in the capacity of worldwide navigation depends on the predicted propagation correction. The authors observe continuously the phase differences of the A-C pair and the A-E pair from April 17 to October 14, 1980, at Busan(35\ulcorner07'. 9N, 129\ulcorner06'. 3E), and analyze the characteristic of daily variation the relation between the theoretical PPC and the measu red PPC to study the accuracy of the position fix. The results are as follows: 1. The results of fourier's analysis for the theoretical PPC and the measured PPC are positive correlation in the coefficients ao, a2, a3 with A-C pair and in the coefficients aO-a3 with A-E pair, and those PPC are apparent to daily periodicity during all measured time. The initial phase is around to 280\ulcorner with A-C pair and 1800 with A-E pair. 2. Daily variatons of the phase difference tend to decrease and the time width to narrow from April toward July, but these variations are opposed to those from July toward October. 3. Mean value of total errors of the position fix by theoretical PPC is 2.67 miles and its standard deviationis O.90miles. 4. Mean value of total errors of the position fix by the measured PPC is 0.63 miles and its standard deviation is 0.217 miles.

  • PDF