• 제목/요약/키워드: accumulated charge

검색결과 123건 처리시간 0.028초

Influence of wall charge configurations prior to addressing discharge on dynamic margin in AC Plasma Display Panel

  • Jung, Y.;Choi, J.H.;Jung, K.B.;Kim, S.B.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.764-767
    • /
    • 2003
  • We have experimentally investigated the influence of wall charge configurations prior to addressing discharge on dynamic margin in AC plasma display panel. In this experiment, we have analyzed the quantity and polarity of wall charge accumulated on the front and rear dielectrics just prior to the addressing discharge under the conventional driving sequence.

  • PDF

AC-PDP구동에서 전위차로 인한 벽전하의 소실과 어드레스 방전 지연시간에 관한 연구 (A Study on an Address Discharge Time Lag and a Wall-Charge Loss Due to the Potential)

  • 전원재;김동훈;김종열;이석현;이천
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1315-1317
    • /
    • 2008
  • The plasma display panel is an image expression display using gas discharge. However gas discharge characteristics vary with temperature. Furthermore, the potential difference among three electrodes appears in sustain period due to external applied voltages. It affects to the wall charge state accumulated on the electrodes. This research aims at identifying that the discharge characteristics depend on the potential difference and temperature. The results show that the wall charge loss increases with increase of the number of applied pulse during sustain period and it severely appears at high temperature.

  • PDF

PE Laminate의 공간전하 형성 (SPACE CHARGE IN PE LAMINATE)

  • 노홍석;김재영;한재홍;서광석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1428-1430
    • /
    • 1994
  • The accumulation of space charge in PE/PE/PE laminates was investigated using the low density polyethylenes having different melt indices from 0.25 to 45 g/10 min. Both heterocharge and homocharge accumulated in parent polyethylenes depend on the value of melt index. A general rule found in this study was that the heterocharge decreases as the melt index increases and finally the homocharge accumulates when the melt index is very high. Because of this reason, PE laminates showed different charge formation characteristics depending on melt index of polyethylene. Details of up to date results are described in the text.

  • PDF

공기층을 가진 저밀도 폴리에틸렌에서의 전도특성과 공간전하 효과 (Effects of Space Charge on Conduction Mechanism in Low density Polyethylene with Air Gap)

  • 박희웅;권윤혁;전승익;황보승;한민구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1438-1440
    • /
    • 1998
  • In this work, simultaneous measur of space charge and conduction current was c out in LDPE with air gap by Pulsed-Electro-Aco Method. Also, effect of long time charging at con electric field on the formation of space charge conduction was investigated. From the experim results. we knew that the homo space charge formed near the dielectric surfaces and moving the bulk of dielectric as the electric field elevated. This was related with the deep traps b carriers and de trapping by Poole-field lowering conduction current was coincident with the Pool emission. From the long time charging experimen obtained the results that the negative space was moving into the dielectric bulk as the cha continued and the positive space charge accumulated at upper surface of LDPE.

  • PDF

RTV 실리콘 고무 코팅재의 표면전하 축적이 발수성에 미치는 영향 (Effect of Accumulated charges on Surface Hydrophobicity of RTV Silicone Rubber)

  • 연복희;허창수;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.597-600
    • /
    • 2001
  • In this paper, we evaluated the effect of accumulated charges on hydrophobicity of room temperature vulcanized(RTV) silicone rubber, which could improve the contamination performance of porcelain insulators, with uv radiation time. Outdoor insulating material could be charged by the corona discharge on field intensified area of insulator and discharge between the water drops. In addition, we performed the accelerated uv radiation on samples and investigated the change of charging decay with time. In this results, it is found that silica-like structure on the surface of RTV silicone rubber was formed by uv treatments and this layer have the characteristic of retaining the charges on surface for a long time. These charges have effects on its hydrophobicity and so adversely effects on contamination performance. Based on our results, we discussed the other degradation mechanism with well known ones.

  • PDF

RIMS 데이타를 활용한 전동차 운행 신뢰성 향상방안 (The Rolling Stock operation reliability improvement plan which applies a data base of the RIMS)

  • 박수중;이도선;전서탁;손영진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.57-64
    • /
    • 2007
  • RIMS(Rolling Stock Information Maintenance System) was installed in structure which it can analyze the data base in need of credibility maintenance. So it could accumulate real data without repulsion of working spot. Information system was installed not following to system but following to working spot. The development of RIMS project was started from March 29, 2001 and it has been operating from October 12, 2004 in Chang-dong Car depot for light maintenance in charge subway line4. So substantial data base was accumulated for three years. This study calculated all RAMS data by analyzing data base accumulated in RIMS and used in dada base about credibility maintenance and found investigation of propriety, expectation of the life cycle cost, the improvement plan on credibility of sorts of cars and formation about the cycle of repairing and maintenance. This got MKBSF MKBF and MTBF about devices and sorts of line4 Rolling Stocks for it.

  • PDF

RIMS 데이타를 활용한 전동차 운행 신뢰성 향상방안 (The Rolling Stock operation reliability improvement plan which applies a data base of the RIMS)

  • 박수중;이도선;전서탁;손영진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.143-150
    • /
    • 2007
  • RIMS(Rolling Stock Information Maintenance System) was installed in structure which it can analyze the data base in need of credibility maintenance. So it could accumulate real data without repulsion of working spot. Information system was installed not following to system but following to working spot. The development of RIMS project was started from March 29, 2001 and it has been operating from October 12, 2004 in Chang-dong Car depot for light maintenance in charge subway line4. So substantial data base was accumulated for three years. This study calculated all RAMS data by analyzing data base accumulated in RIMS and used in dada base about credibility maintenance and found investigation of propriety, expectation of the life cycle cost, the improvement plan on credibility of sorts of cars and formation about the cycle of repairing and maintenance. This got MKBSF MKBF and MTBF about devices and sorts of line4 Rolling Stocks for it.

  • PDF

캐패시터 부정합 보정 기능을 가진 8비트 스위치-캐패시터 사이클릭 D/A 변환기 설계 (A Design of 8-bit Switched-Capacitor Cyclic DAC with Mismatch Compensation of Capacitors)

  • 양상혁;송지섭;김석기;이계신;이용민
    • 전기학회논문지
    • /
    • 제60권2호
    • /
    • pp.315-319
    • /
    • 2011
  • A switched-capacitor cyclic DAC scheme with mismatch compensation of capacitors is designed. In cyclic DAC, a little error between two capacitors is accumulated every cycle. As a result, the accumulated error influences the final analog output which is wrong data. Therefore, a mismatch compensation technique was proposed and the error can be effectively reduced, which alleviates the matching requirement. In order to verify the operation of the proposed DAC, an 8-bit switched-capacitor cyclic DAC is designed through HSPICE simulation and implemented through magna 0.18um standard CMOS process.

정전기 방전에 의한 개소린-공기혼합기체의 최소착화에너지에 관한 연구 (The Study about The Minimum Ignition Energy for Electrostatic Discharge in The Gasoline-air Mixture)

  • 황명환;이덕출
    • 한국화재소방학회논문지
    • /
    • 제10권1호
    • /
    • pp.3-9
    • /
    • 1996
  • Electrostatic charge is generated in large scale or high speed processes dealing with materials with large resistance, or under complicated condition. Fire and explosion often occur due to electrostatic charge accumulated in flammable gases, vapor, liquids and powder. It is usually very difficult to verify the cause of accidents as well as the prevention. In this study, it is shown that the needle electrode needs the electrode gap from 1.8mm to 3.8mm, sphere electrode and plate electrodes need the electrode gap of 1.9mmfor the minimum ignition energy. The sphere electrode and the plate electrode requires 12.8mJ and 3.2mJ of minimum ignition energy respectively with the electrode gap of 1.1mm. The ignition voltage rises to very large value as the ground resistance increases.

  • PDF

직류 및 교류인가시 CV전력 케이블에 미치는 공간전하 특성 연구 (A Study of Characteristic for Space Charge in CV Power Cable When Impressed DC and AC Voltage)

  • 정영일;임용배;김종서
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1960-1962
    • /
    • 2000
  • Polyehtylene[PE] in polymer insulation materials of used power cable have carried out in abundance of experiment and study for electrical conduction. insulation breakdown. dielectric character and so on. When apply to field for power cable to make PE, application of DC withstand test to put in practice for inspection is get to effect accumulated space charge. In this paper, to make use of Pulsed Electro-Acoustic(PEA). It is analysis to take shape space charges under AC and DC voltage, clear up the point at issue for effect of DC withstand test.

  • PDF