• 제목/요약/키워드: acceleration braking force

검색결과 23건 처리시간 0.022초

사장교의 구조식별을 위한 가진실험 데이터분석 (FVT Signal Processing for Structural Identification of Cable-stayed Bridge)

  • 이정휘;김정인;윤자걸
    • 한국소음진동공학회논문집
    • /
    • 제14권10호
    • /
    • pp.923-929
    • /
    • 2004
  • In this research, Forced Vibration Test(FVT) on a cable stayed bridge was conducted to examine the validity of the frequency domain pattern recognition method using signal anomaly index and artificial neuralnetwork. 7he considering structure, Samchunpo Bridge, located in Sachun-Shi, Kyungsangnam-Do, is a cable stayed bridge with the 436 meter span. The excitation force was induced by a sudden braking of a fully loaded truck. and vortical acceleration signals were acquired at 14 points. The initial 2-dimensional FE-model was developed from the design documents to prepare the training sets for the artificial neural network, and then the model calibration was performed with the field test data. As a result of the model calibration, we obtained the FFT spectrums from the model simulation, which was similar to those from the vibration test. These tests and the simulation data will be used for the structural identification using arbitrarily added masses to the bridge.

사장교의 구조식별을 위한 가진실험 데이터분석 (FVT Signal Processing for Structural Identification of Cable-Stayed Bridge)

  • 윤자걸;이정휘;김정인
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.619-623
    • /
    • 2003
  • In this research, Forced Vibration Test(FVT) on a cable stayed bridge was conducted to examine the validity of the frequency domain pattern recognition method using signal anomaly index and artificial neural network. The considering structure, Samchunpo Bridge, located in Sachun-Shi, Kyungsangnam-Do, is a cable stayed bridge with the 436 meter span. The excitation force was induced by a sudden braking of a fully loaded truck, and vertical acceleration signals were acquired at 14 points. The initial 2-dimensional FE-model was developed from the design documents to prepare the training sets for the artificial neural network, and then the model calibration was performed with the field test data. As a result of the model calibration, we obtained the FFT spectrums from the model simulation, which was similar to those from the vibration test. These tests and the simulation data will be used fur the structural identification using arbitrarily added masses to the bridge.

  • PDF

철도교용 프리케스트 바닥판의 온도변화를 고려한 적정한 종방향 프리스트레스 수준의 산정 (Evaluation of Proper Level of the Longitudinal Prestress for the Precast Deck of Railway Bridges Considering the Temperature Change)

  • 전세진;김영진;김성운;김철영
    • 대한토목학회논문집
    • /
    • 제26권3D호
    • /
    • pp.499-509
    • /
    • 2006
  • 프리캐스트 콘크리트 바닥판은 일반적인 현장타설 바닥판과 비교할 때 많은 장점을 가지고 있으며, 최근 국내에서도 도로교의 노후 바닥판 교체 공사 및 신설 도로교에 성공적으로 적용되고 있다. 하지만, 철도교에 프리캐스트 바닥판을 적용하기 위해서는 활하중, 장대레일 종하중, 시제동하중, 온도변화, 건조수축 등 도로교와 철도교의 하중 특성의 차이를 적절히 반영한 설계가 요구되며, 특히 횡방향 이음부의 연속성을 확보하여 일체화시키기 위해 바닥판 내부에 배치한 종방향 텐던의 적정한 프리스트레스 수준을 평가하는 연구가 요망된다. 따라서 본 연구에서는 철도교에 빈번히 적용되는 PSC 합성거더 철도교에 대하여 정밀한 3차원 유한요소해석을 통해 주요 설계하중이 유발하는 바닥판의 종방향 응력을 산정하였다. 그 결과 종방향 인장응력을 유발하는 지배적인 요인은 활하중보다는 바닥판의 온도 저하나 시동하중으로 나타났으며, 특히 온도의 영향은 설계기준상의 제안식 또는 이론식과도 비교해 가며 중점적으로 분석하였다. 종방향 인장응력을 상쇄하여 올바른 구조거동을 유도하기 위한 프리스트레스의 범위를 고찰한 결과, 대상 철도교에 대해 2.4 MPa 이상의 프리스트레스를 도입하는 것이 적정한 것으로 나타났으며 이는 도로교의 경우와 유사한 수준으로 평가되었다.