• 제목/요약/키워드: ac susceptibility

검색결과 60건 처리시간 0.022초

Substrate-free Biosensing using Brownian Rotation of Bio-conjugated Magnetic Nanoparticles

  • Chung Seok-Hwan;Hoffmann Axel;Chen, Liaohai;Sun, Shouheng;Guslienko Konstantin;Grimsditch Marcos;Bader Samuel D.
    • Journal of Magnetics
    • /
    • 제11권4호
    • /
    • pp.189-194
    • /
    • 2006
  • The recent development of bio-conjugated magnetic nanoparticles offers many opportunities for applications in the field of biomedicine. In particular, the use of magnetic nanoparticles for biosensing has generated widespread research efforts following the progress of various magnetic field sensors. Here we demonstrate substrate-free biosensing approaches based on the Brownian rotation of ferromagnetic nanoparticles suspended in liquids. The signal transduction is through the measurement of the magnetic ac susceptibility as a function of frequency, whose peak position changes due to the modification of the hydrodynamic radius of bio-conjugated magnetic nanoparticles upon binding to target bio-molecules. The advantage of this approach includes its relative simplicity and integrity compared to methods that use substrate-based stray-field detectors.

Current Carrying Iron Whiskers: A New Magnetic Configuration

  • Lee, J.G.;Arrott, A.S.
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.372-375
    • /
    • 1995
  • The magnetization pattern of the central cross section deduced from the ac susceptibility measurement is described with an analytical function. The function is based on a charge-free configuration. The thickness of the $^{\circ}$ wall lying in a (100) plane and the wall energy are calculated analytically. Total energy of the domain structure has been minimized with Ritz's method. As the result of the minimization, the energy density of the $^{\circ}$ wall lying in a (100) plane is $0.58\;erg/cm^{2}$ and the one for a (110) plane is $1.18\;erg/cm^{2}$. Thicknesses of these walls are calculated numerically. Also, the calculation indicates there is a small central domain at the cross section without applied current. With the ac susceptibility measurement the existence of the domain without current can be identified.

  • PDF

Identification and Screening of Gene(s) Related to Susceptibility to Enterotoxigenic Escherichia coli F4ab/ac in Piglets

  • Li, Hejun;Li, Yuhua;Qiu, Xiaotian;Niu, Xiaoyan;Liu, Yang;Zhang, Qin
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제21권4호
    • /
    • pp.489-493
    • /
    • 2008
  • In 2004, Jorgensen and coworkers proposed the MUC4 gene as a candidate gene of enterotoxigenic Escherichia coli (ETEC) F4ab/ac receptor in piglets and a mutation of $G{\rightarrow}C$ in intron 7 of MUC4 was identified to be associated with the ETEC F4ab/ac adhesion phenotypes. In this study, we used 310 piglets of three breeds (Landrace, Large White and Chinese Songliao Black) to analyze the relationship between this mutation and the F4ab/ac adhesion phenotype. The results show that the genotypes at this site and the ETEC F4ab/ac adhesion phenotypes were not completely consistent, although they are very strongly associated. Among the individuals with genotype CC, which was identified as a resistant genotype to F4ab/ac adhesion, only 72.1% (124/172) were non-adhesive to ETEC F4ab and 77.9% (134/172) were non-adhesive to ETEC F4ac infections. This suggests that this mutation may not be the causative mutation for ETEC F4ab/ac adhesion, rather, the actual causative mutation may be in another gene closely linked to MUC4, or at aother site within the MUC4 gene. Our results also suggest that the receptors of F4ab and F4ac may be determined by two different but closely linked loci. In order to screen other genes related to F4ab/ac adhesion in piglets, the mRNA profiles from six full sib piglets, of which three were adhesive to ETEC F4ab/ac and three non-adhesive, were analyzed by suppression subtractive hybridization (SSH). One up-regulated gene, Ep-CAM, was selected for further analysis based on its role in the intestinal epithelial cells adhesion. Using real-time RT-PCR, we found that the Ep-CAM gene was significantly up-regulated in the piglets adhesive to F4ab/ac. It was mapped to SSC3q11-q14 by radiation hybrid mapping.

Determination of the Size Distribution of Magnetite Nanoparticles from Magnetic Measurements

  • Yoon, Sung-Hyun
    • Journal of Magnetics
    • /
    • 제16권4호
    • /
    • pp.368-373
    • /
    • 2011
  • Particle size distributions in 10 nm magnetite ferrofluids are analyzed based on both dc and ac magnetic measurements. Modified log-normal distributions are used for fitting the experimental results, which allows for a proper account of the narrow distributions. The calculated average particle sizes are in good agreement with the TEM results. However the ac method gives a much narrower distribution width than that of the dc magnetization curve fit. The proposed measurements combined with the analysis methods are useful for the characterization of ferrofluids being considered for biomedical applications.

Standardization of the Critical Temperature Measurement by Using an AC Susceptometer

  • Lee, K. W.;Kim, M. S.;Kim, K.;Kim, D. H.;Lee, S. G.
    • Progress in Superconductivity
    • /
    • 제7권1호
    • /
    • pp.22-27
    • /
    • 2005
  • We have studied the standardization of critical temperature measurements by using an ac susceptometer. Wire forms of NbTi, $Nb_{3}Sn$, and Bi-2223 superconductors were prepared to measure the temperature dependences of the magnetization. In order to study the optimum ac magnetic field and frequency, various amplitudes from 2 Oe to 10 Oe with frequencies from 11.3 Hz to 1033 Hz were applied to three specimens. Analytical comparison of the magnetic curves with the resistive curves was accomplished to investigate validity of using the new method.

  • PDF

AC Loss Measurement and Analysis of Ag-sheathed Bi-2223 Conductors in Terms of Eddy Currents and Flux Creep

  • Jang, Mi-Hye
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권6호
    • /
    • pp.211-215
    • /
    • 2003
  • Alternating current (AC) losses of two Bi-2223 ([Bi, Pb] : Sr : Ca : Cu :O = 2:2:2:3) tapes [one untwisted (Tape I, twist-pitch of $\infty$ mm) and the other with a twist-pitch of 8mm (Tape II) ] were measured and compared. These samples, produced by the powder-in-tube (PIT) method, are multi-filamentary and have a Ag/Au and Ag matrix, respectively. Susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation.

Comparative Performance of Susceptibility Map-Weighted MRI According to the Acquisition Planes in the Diagnosis of Neurodegenerative Parkinsonism

  • Suiji Lee;Chong Hyun Suh;Sungyang Jo;Sun Ju Chung;Hwon Heo;Woo Hyun Shim;Jongho Lee;Ho Sung Kim;Sang Joon Kim;Eung Yeop Kim
    • Korean Journal of Radiology
    • /
    • 제25권3호
    • /
    • pp.267-276
    • /
    • 2024
  • Objective: To evaluate the diagnostic performance of susceptibility map-weighted imaging (SMwI) taken in different acquisition planes for discriminating patients with neurodegenerative parkinsonism from those without. Materials and Methods: This retrospective, observational, single-institution study enrolled consecutive patients who visited movement disorder clinics and underwent brain MRI and 18F-FP-CIT PET between September 2021 and December 2021. SMwI images were acquired in both the oblique (perpendicular to the midbrain) and the anterior commissure-posterior commissure (AC-PC) planes. Hyperintensity in the substantia nigra was determined by two neuroradiologists. 18F-FP-CIT PET was used as the reference standard. Inter-rater agreement was assessed using Cohen;s kappa coefficient. The diagnostic performance of SMwI in the two planes was analyzed separately for the right and left substantia nigra. Multivariable logistic regression analysis with generalized estimating equations was applied to compare the diagnostic performance of the two planes. Results: In total, 194 patients were included, of whom 105 and 103 had positive results on 18F-FP-CIT PET in the left and right substantia nigra, respectively. Good inter-rater agreement in the oblique (κ = 0.772/0.658 for left/right) and AC-PC planes (0.730/0.741 for left/right) was confirmed. The pooled sensitivities for two readers were 86.4% (178/206, left) and 83.3% (175/210, right) in the oblique plane and 87.4% (180/206, left) and 87.6% (184/210, right) in the AC-PC plane. The pooled specificities for two readers were 83.5% (152/182, left) and 82.0% (146/178, right) in the oblique plane, and 83.5% (152/182, left) and 86.0% (153/178, right) in the AC-PC plane. There were no significant differences in the diagnostic performance between the two planes (P > 0.05). Conclusion: There are no significant difference in the diagnostic performance of SMwI performed in the oblique and AC-PC plane in discriminating patients with parkinsonism from those without. This finding affirms that each institution may choose the imaging plane for SMwI according to their clinical settings.

파밤나방 세포주에서 Autographa californica 핵다각체병 바이러스의 감염 특성 (Characteristics of Autographa californica Nuclear Polyhedrosis Virus in Spodoptera exigua Cell Line.)

  • 최재영;우수동;홍혜경;강석권
    • 한국미생물·생명공학회지
    • /
    • 제26권2호
    • /
    • pp.161-166
    • /
    • 1998
  • AcNPV에 대해 감수성을 보이는 파밤나방 세포주인 Se301 세포주의 AcNPV를 이용한 발현 벡터계에서의 유용성을 알아보기 위하여 Se301세포주에서 AcNPV의 감염 특성을 Sf-21 세포주에서와 비교하였다. 그 결과, 바이러스의 감염상은 두 세포주에서 거의 유사하였으나 감염 7일 후에 세포로부터 방출된 다각체의 비율은 Se301 세포주에서 훨씬 높았다. 또한 전체 다각체 생성율은 Se301 세포주에서 약간 높았지만 그 차이는 매우 근소하여 대체적으로 두 세포주에서 거의 비슷하였으나 생성된 다각체의 크기는 Se301세포주에서 더욱 컸다. 한편, 세포주나 바이러스의 증식율과는 무관하게 AcNPV에 의한 다각체 단백질의 발현량이 Se301 세포주에서 약 2.4배 높게 나타남으로써 Se301 세포주가 AcNPV를 이용한 발현 벡터계에서 숙주 세포로서 매우 유용하게 이용될 수 있음을 보여 주었다.

  • PDF

A Study of Characteristic of Electrical-magnetic and Neutron Diffraction of Long-wire High-superconductor for Reducing Energy Losses

  • Jang, Mi-Hye
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권6호
    • /
    • pp.265-272
    • /
    • 2008
  • In this paper, AC losses of long wire Bi-2223 tapes with different twist pitch of superconducting core were fabricated, measured and analyzed. These samples produced by a powder-in-tube method are multi-filamentary tape with Ag matrix. Also, it's produced by non-twist. The critical current measurement was carried out under the environment in Liquid nitrogen and in zero field by 4-prob method. And the Magnetic measurement was carried out under the environment of applied time-varying transport current by transport method. From experiment, the susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O).

Flux Loss and Neutron Diffraction Measurement Ag-sheathed Bi-2223 Tapes in terms of Flux Creep

  • Jang Mi-Hye
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권5호
    • /
    • pp.204-210
    • /
    • 2005
  • Alternating current (AC) losses of two Bi-2223 ([Bi, Pb]: Sr: Ca: Cu: O = 2:2:2:3) tapes [(Tape I, un-twist-pitch) and the other with a twist-pitch of 10 mm (Tape II)] were measured and compared. These samples, produced by the powder-in-(Ag) tube (PIT) method, are multi-filamentary. Also, it's produced by non-twist and different twist pitch (8, 10, 13, 30, 50 and 70 mm). The critical current measurement was carried out under the environment in liquid Nitrogen and in zero-field by 4-probe method. Susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O)