• Title/Summary/Keyword: absorption test

Search Result 1,433, Processing Time 0.032 seconds

Method of deriving the acoustic impedance and sound absorption coefficient of materials by manipulating electrical impedance of a loudspeaker (스피커의 전기적 임피던스를 이용한 시료의 음향임피던스와 흡음계수 도출 기법)

  • Doo, Sejin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.3
    • /
    • pp.254-260
    • /
    • 2021
  • When measuring the sound absorption coefficient of a specimen, a reverberation room which is costly or an impedance tube which has limitations in measuring low frequencies have been engaged. In this paper, a new measurement method of acoustic impedance or sound absorption coefficient has been suggested, which does not need microphones and only uses electrical impedance measurement data and derived Thiele/Small parameters of a speaker. The theory of this method has been described using equivalent circuit of the loudspeaker and acoustic properties of a test specimen are measured to demonstrate the validity of this method. It was confirmed that this method can easily measure the sound absorption coefficient in the low frequency band, which was previously difficult to trust. The advantages, limitations, and applicability of this method are discussed.

A Study on the Characteristics of Local Corrosion for Gas Absorption Refrigeration and Hot Water Systems in LiBr-$H_2O$ Working Fluids (LiBr작동유체 중에서 가스흡수식 냉온수기의 국부부식 특성에 관한 연구)

  • Uh- Joh Lim;Ki-Cheol Jeong;Byoung-Du Yun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.714-720
    • /
    • 2003
  • Due to the electric power shortage in summer season and regulation of freon refrigerant, the application of gas absorption refrigeration and hot water systems are considerably increasing trend. But, this system consists of condenser, heat exchanger, supply pipe and radiator etc. which are easily corroded by acidity and dissolved oxygen and gases. In result, this system occurs scale attachment and corrosion damage like pitting and crevice corrosion. In this study, electrochemical polarization test of heat exchanger tubing material (copper, aluminium brass, 30% cupronickel(30% Cu-Ni)) was carried out in 60% lithium bromide solution at $95^{\circ}C$. As a result of polarization test, corrosion behavior by impressed potential and local corrosion. such as galvanic corrosion, pitting corrosion behavior, of tubing materials was investigated. The main results obtained are as follows: (1) The effect of pitting and crevice corrosion control of 30% cupronickel in 60% LiBr solution at $95^{\circ}C$ is very excellent. (2) Dissimilar metal corrosion of 30% cupronickel coupling to aluminium bronze is the most sensitive. (3) Current density behavior of tube materials by impressed potential is high in order of copper > aluminium brass > 30% cupronickel.

A Study on the Axial Crushing Behavior of Aluminum Cm Circular Members for light-weight (경량화용 Al/CFRP원형 부재의 축 압궤거동에 관한 연구)

  • Lee, Kil-Sung;Cha, Cheon-Seok;Yang, In-Young
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.5
    • /
    • pp.50-56
    • /
    • 2005
  • Aluminum member absorbs energy by stable plastic deformation under axial loading. While CFRP(Carbon Fiber Reinforced Plastics) member absorbs energy by unstable brittle failure but its specific strength and stiffness is higher than those of aluminum member. In this study, for complement of detects and synergy effect by combination with the advantages of each member, the axial collapse tests were performed for aluminum CFRP members which are composed of aluminum members wrapped with CFRP outside aluminum circular members. Based on the respective collapse characteristics of aluminum and CFRP members, crushing behavior and energy absorption characteristics were analyzed for aluminum CRRP members which have different CFRP fiber orientation angle and thickness Test results showed that aluminum CFRP members supplemented the unstable brittle failure of CFRP members due to ductile nature of inner aluminum members. It turned out that the CFRP fiber orientation angle and thickness influence energy absorption capability together with the collapse mode of the members.

Experimental Study on Cavitation Instability of a Solution Pump Inducer in an Absorption Chiller-Heater (흡수식 냉온수기내 용액펌프 Inducer의 Cavitation 불안정성에 대한 실험적 연구)

  • Seo, Min;Lee, Kyung-Hoon;Kang, Shin-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2434-2439
    • /
    • 2008
  • This paper was studied on the cavitation instability of a Solution Pump Inducer in an absorption chiller-heater. Inlet pressure of LiBr and rotational speed at nominal mode are 2,800 Pa and 3,500 rpm respectively. Due to the marginal operation of available NPSH, the cavitation performance of the inducer is critical for the stable operation without the deterioration of head performance. In the study, cavitation performance and its mode of instability was investigated experimentally. Water was used as the working fluid and the test inducer was scaled up as 1.75 times for detail measurements and flow visualization. Inlet pressure was controlled by a vacuum pump. This research focused on types of cavitation instability and phenomena to investigate the possibility of harmful damage due to cavitation instability. Casing wall pressure and instantaneous inlet pressure was measured to observe the unsteady flow characteristics. Through the visualization and spectrum analysis of pressure, the occurrence region and intensity of asymmetric cavitation and cavitation surge are analyzed in the test inducer.

  • PDF

Fatigue Characterization of Glass/Polypropylene Composite Bone Plates Locked with an Artificial Tibia under Moisture Environment (인조골에 체결된 유리섬유/폴리프로필렌 복합재료 고정판의 수분 환경 피로 특성)

  • Han, Min-Gu;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.26 no.5
    • /
    • pp.328-333
    • /
    • 2013
  • In this study, bone plate made of glass/polypropylene composite material which was applied to an artificial bone was tested to check the service ability under fatigue loading. To check serviceability of composite bone plates fatigue test was carried out considering changes in the moisture absorption rate, locking position of screws and loading condition. Test results showed that all the tested specimens had the fatigue life more than one million cycles which was much higher fatigue life than the expected value of 650,000 cycles. Screw position was not critical impact on the deformation of the fracture site. In this paper, the mechanical performance of the glass/polypropylene composite was verified by fatigue test under various water absorption conditions, and this result may give useful information on the design of composite bone plate.

Energy Absorption Mechanism of Glass/Epoxy 3-D braided structure in Low Velocity Impact Test (유리/에폭시 3차원 브레이드 복합재료의 저속 충격 에너지 흡수기구)

  • Joo Ki Ho;Sul In Hwan;Kim Soo Chang;Kang Tae Jin
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.10a
    • /
    • pp.167-170
    • /
    • 2004
  • In order to investigate the impact behaviors of 3-D braided glass/epoxy composites, the energy profiles and damage area were compared to the laminates of similar volume fraction and composition. The energy profiles showed different characteristics from each other which indicates they have distict energy absorption mechanisms. The image analysis on the damage projections visualized the crack propagation paths along the fiber direction.

  • PDF

A Study on the Absorption Enhancing Effect of Sodium 5-Methoxysalicylate(II) (Sodium 5-Methoxy Salicylate의 흡수촉진 효과에 관한 연구 (II). 흡수촉진제에 대한 반응성)

  • 김기헌
    • YAKHAK HOEJI
    • /
    • v.30 no.2
    • /
    • pp.96-99
    • /
    • 1986
  • Absorption enhancing effect of 5 MSA-Na at the mucous memberanes of the rectum and duodenum was studied via in vitro sac test. There were no significant differences between two membranes. Effect of 5MSA-Na on the transfer of CMZ to the tissue was also studied via in situ loop method. There was no significant difference at the duodenum, compared to the control when CMZ was administered intravenously. Transfer of CMZ to the loop of the rectum was increased in the presence of 5MSA-Na compared to the control, which might be attributed to the enhanced permeability of the mucous memberane of the rectum.

  • PDF

The energy absorption characteristics of thin-walled members for the use of light-weight vehicles (경량화용 차체구조 박육부재의 에너지 흡수특성)

  • 김정호;윤규종;양인영
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.3
    • /
    • pp.33-43
    • /
    • 1996
  • In this paper, collapse test of thin-walled structures, which are widely used in the vehicle members is carried out to observe the dependence of cross-sectional forms and materials on the absorbed energy in the viewpoint of crashworthiness. Also, specimens consist of two kinds (Al, CFRP) with various thickness. Comparisons of circular specimens are made to find characteristics of the different specimens on the absorption ability according to specimen thickness and materials.

  • PDF

Impact Energy Absorption Characteristics of the Extruded Aluminum Sections for Rail Vehicles (철도차량 알루미늄 압출재의 충격에너지 흡수 특성)

  • 허승진;정영섭;양승국;구정서;송달호
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.155-162
    • /
    • 1999
  • Extruded aluminum sections are used to the light construction of the rall vehicles structures However, the research works on the crashworthy design of the extruded aluminum sections are not published sufficiently in this paper, the impact energy absorption characteristics of extruded aluminum sections are investigated by crash simulation and test The optimized energy absorbing studies are also performed based on the selected design parameter variations of the sectional shapes and the dimensional ratios.

  • PDF