• Title/Summary/Keyword: absorption and scattering coefficient

Search Result 55, Processing Time 0.026 seconds

An Analysis of the Characteristics of Aerosol Light Scattering Coefficients at Seoul and Baengnyeongdo (서울과 백령도의 에어로솔 산란계수 특성 분석)

  • Eun, Seung-Hee;Nam, Hyoung-Gu;Kim, Byung-Gon;Park, Jin-Soo;Ahn, Jun-Young;Lee, Seok-Jo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.3
    • /
    • pp.264-274
    • /
    • 2013
  • This study investigates long-term trends and characteristics of aerosol light scattering coefficient at Seoul and Baengnyeongdo in order to understand aerosol optical and radiative properties around Korea. The analysis period is limited to one year of 2011. First, the aerosol scattering coefficients (${\sigma}_{sp}$) of both sites show strong linear dependence on the $PM_{2.5}$ mass concentrations with significant correlations between both. Further, correlations and sensitivity between ${\sigma}_{sp}$ and $PM_{2.5}$ increase with relative humidity, implying both relationships are strongly dependent upon moisture amounts in the atmosphere. This study applied 3-step careful quality control procedures to the analysis of ${\sigma}_{sp}$ for the insurance of data confidence. For the relationship analysis of extinction coefficients (${\sigma}_{ext}$) to visibility and aerosol optical depth, ${\sigma}_{sp}$ observed at 3 p.m. have been used with help of aerosol absorption coefficients (${\sigma}_{ap}$) in order to remove its dependence upon relative humidity, and also those of rainy period have been excluded. As expected, ${\sigma}_{ext}$ estimated are inversely proportional to visibility observation by eye. Finally, aerosol extinction coefficients have been vertically integrated with an assumption of nearly well-mixed within an e-folding height to determine aerosol optical depth, and compared with those retrieved from sunphotometer. The results show a reasonable agreement in spite of an inherent difference of each definition. We expect these findings would help to eventually understand aerosol radiative forcing and its effect on the regional climate change around Korea.

A Compact Optical System using LED and CMOS Image Sensor for Liver Function Analysis (LED와 CMOS 이미지 센서 기반 간 기능 분석용 소형 광학장치)

  • Kim, Chul;Lim, Chang-Jin;Nam, Myung-Hyun;Kim, Dong-Sik;Seo, Sung-Kyu;Pak, Jung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.270-275
    • /
    • 2012
  • This paper presents a portable and compact optical device which can conveniently be used to perform a functional analysis of human liver function. The proposed system employed red/green LEDs, as a light source, and CMOS image sensor, which is commonly used in cellular phones. With this system, several blood serum samples have been evaluated for liver functional analysis by measuring light absorption level through the blood serum samples depending on aspartate aminotransferase (AST), alanine aminotransferase (ALT), and total bilirubin concentration. The light absorption through the blood serum samples containing AST, ALT, or total bilirubin can provide their concentrations. The green light absorption is more sensitive to the concentration of AST or ALT, and the red light absorption is more sensitive to the total bilirubuin concentration. Additional calibration steps were performed by using a MATLAB program in order to eliminate the light scattering effects from the extraneous particles existing in each blood serum sample. From the blind test, three standard light intensity curves through each enzyme have been obtained and the enzyme concentration values have been compared to those obtained from a commercially available biochemistry analyzer (Toshiba 200 FR). The average percent difference in the obtained concentrations from two systems for AST, ALT, and total bilirubin concentration came out to be 7.79%, 7.98%. and 7.56%, respectively, with the adjusted coefficient of determination (R2) higher than 0.98. This system can possibly lead to a low-cost and simple system that can be used as a point-of-care (POC) system in a condition without advanced equipments.

A numerical study on the combined natural convection and radiation in a partially open complex enclosure with a heater and partitions (발열체와 격막이 있고 일부가 열린 복합공간내의 자연대류-복사열전달에 관한 수치적 연구)

  • Kim, Tae-Guk;Min, Dong-Ho;Han, Gyu-Ik;Son, Bong-Se;Seo, Seok-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.2
    • /
    • pp.235-251
    • /
    • 1997
  • A numerical simulation on the combined natural convection and radiation is carried out in a partially open rectangular enclosure with a heater by using the finite volume and the S-8 discrete ordinate methods. The fluid inside the enclosure is considered as an absorbing, emitting and anisotropic scattering media. The heater causes a natural circulation of the fluid (10$^{5}$ $^{9}$ ) which results in significant in-flow of the ambient cold fluid through the partially open wall. Comparing the results of pure convection with those of the combined convection- radiation, the combined heat transfer results with small Planck numbers (P$_{l}$ <1.0) show much stronger circulation than those of the pure convection, and the fluid circulation is more evident for larger Rayleigh numbers. When one of three radiative properties - the medium absorption coefficient, the wall reflectivity, and the scattering albedo - increases, the fluid circulation and the heat transfer in the enclosure are reduced. The location of the heater and the open ratio of the right wall are also shown to affect the fluid circulation and heat transfer significantly. However, the anisotropy of the scattering phase function is shown to be unimportant for the fluid circulation and heat transfer within the enclosure considered in this study.

The Effects of the Cutting Length of Paper Mulberry Bast Fiber on Pulping and Hanji Properties(I) - White bast of Korea grown paper mulberry - (닥나무 인피섬유의 절단장이 펄프화 및 한지의 물성에 미치는 영향(제1보) - 국산 닥 백피의 특성 -)

  • Lim, Gang-Hyouk;Choi, Tae-Ho
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.40 no.2
    • /
    • pp.57-64
    • /
    • 2008
  • In general, the entire of paper mulberry bark, which is not cut into pieces with an appropriate length, have been used in the pulping. This kind of pulping method couldn't accomplish the improvement of beating and sheet forming efficiency. For this reason, we investigated the effects of the cutting length of paper mulberry bast fiber on pulping and Hanji (Korean traditional paper) properties, in order to develop high quality Hanji manufacturing process. The cutting length variation of paper mulberry white bast did not great effects on pulp yields. The pulp yields based on pulping methods were sulfomethylated pulping av. 57.4%, alkali-hydrogen peroxide pulping av. 55.4%, and alkaline pulping av. 53.5% respectively. The optical properties such as brightness, opacity, scattering coefficient, and absorption coefficient were slightly improved by the increase of paper mulberry white bast cutting length. The increase of paper mulberry white bast cutting length resulted in poor sheet formation. Physical properties such as breaking length, TEA, tear index, burst index, and folding endurance were slightly improved by the increase of cutting length. The modified pulping processes, which used sulfomethylated method and alkali-hydrogen peroxide method, showed better pulp and sheet properties than conventional alkaline pulping.

A Study on the Radiation Heat Transfer Characteristics of Liquid Droplet Radiator (액적방열기의 복사열전달 특성에 관한 연구)

  • 김금무;김용모;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.32-40
    • /
    • 1994
  • The radiative heat transfer analysis in particle layer has an inherent difficulty in treating the governing integro-differential equations, which are derived from the remote effects. Most of the existing analyses are limited to the one dimensional system, taking into account only absorption or isotropic scatting of solid particles. Fortunately, a new Monte Carlo Simulation method is recently developed to analyse multidimensional radiative heat transfer in particles with anisotropically scatting. By this method, the present study analyses the radiative heat transfer in dispersed particles through the numerous droplets in the liquid droplet radiator to develop a technique of liquid droplet radiator. Consequently, knows that the radiative heat flux in particle layer is influenced by exitinction coefficient, optical thickness and surface area of particles in the system.

  • PDF

Experimental Investigation for the Attenuation Coefficient of Ultrasonic Guided Wave (유도초음파의 감쇠계수에 대한 실험적 고찰)

  • Lee, Dong-Jin;Cho, Youn-Ho;Lee, Joon-Hyun;Shin, Dong-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.458-465
    • /
    • 2009
  • In general, ultrasonic guided wave techniques that used for an evaluation of the internal defect have been applied without considering energy loss. It can be found out that the significant attenuation is observed in the signal of structure with defect by the scattering and absorption. Even in the signal acquired from defect-free structure, this attenuation can be also significant. Therefore, it is very essential to determine the Lamb wave propagation characteristics depending on modes because the dispersibility of Lamb wave can be easily influenced by the attenuation effect with frequency and thickness. For this reason, changing the propagation distance, attenuation coefficient of each Lamb wave mode needs to be investigated by the contact pitch-catch method with PZT(piezoelectric) sensors. In this paper, the experimental attenuation coefficient is measured by choosing the following three different variables; mode, thickness and plate materials. As a result, experimental attenuation coefficient is obtained as the function of variables.

A Study on Spectra of Laser Induced Flourescence in Phantom of N-propyl-N,N-dimethylethanolamine (N-propyl-N,N-dimethylethanolamine의 Phantom에서 Laser Induced Fluorescence의 스펙트라에 관한 연구)

  • Kim, Ki-Jun;Lee, Joo-Ho;Lee, Joo-Youb;Sung, Wan-Mo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.330-338
    • /
    • 2015
  • The influences of fluorescence, scattering, and flocculation in turbid material by light scattering of N-propyl-N,N-dimethylethanolamine, fluorescence agent and absorption agent were interpreted for the scattered fluorescence intensity and wavelength. They have been studied the molecular properties by the spectroscopy of laser induced fluorescence (LIF) and flocculation. The effects of optical properties in scattering media have been found by the optical parameters(${\mu}_s$, ${\mu}_a$, ${\mu}_t$). Flocculation is an important step in many solid-liquid separation processes and is widely used. When two particles approach each other, interactions of several colloid particles can come into play which may have major effect on the flocculation and LIF process. The values of scattering coefficient ${\mu}_s$ are large by means of the increasing scattering of scatterer, The values have been found that the slope decays exponentially as a function of concentration from laser source to detector by our experimental result. It may also aid in designing the best model for oil chemistry, bio-pharmaceutical, laser medicine and application of medical engineering on LIF and coagulation in particle transport mode.

Characteristics of Visibility Impairment by Semi-Continuous Optical and Chemical Property Monitoring of Aerosols in Seoul (에어로졸의 광학 및 화학 특성 준실시간 모니터링을 통한 서울지역 시정 감쇄 분석)

  • Park, Jong-Sung;Park, Seung-Myung;Song, In-Ho;Shin, Hye-Jung;Hong, You-Deog
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.4
    • /
    • pp.319-329
    • /
    • 2015
  • The characteristics of aerosol light extinction were investigated by comparing measured and calculated extinction coefficient to understand the contribution of air pollutants on visibility impairment for data during 4 months (Jan~ April), 2014. The integrated nephelometer and aethalometer system were installed to measure the scattering and absorption coefficients of aerosol as well as BAM 1020, MARGA, semi-continuous OCEC analyzer, and online-XRF to calculate the extinction coefficient. The IMPROVE_2005 equation was used to determine the contributions of different chemical components on visibility impairment in $PM_{2.5}$ and $PM_{10}$ due to highest correlation with measured data. Sulfate, nitrate, and organic mass by carbon (OMC) of fine aerosol were the major contributors affecting on visibility impairment. Total contributions to light extinction were calculated as $631.0Mm^{-1}$ for the worst-case and $64.4Mm^{-1}$ for the best-case. The concentrations of aerosol component for the worst-case were 38.4 times and 45.5 times larger than those of the best-case for $(NH_4)_2SO_4$ and $NH_4NO_3$, respectively. At lower visibility condition, in which extinction coefficient was higher than $400Mm^{-1}$, extinction coefficient varied according to the relative humidity variation regardless of $PM_{2.5}$.

Aerosol Light Absorption and Scattering Coefficient Measurements with a Photoacoustic and Nephelometric Spectrometer (광음향 및 네펠로미터 방식을 이용한 에어로졸 흡수 및 산란계수 측정)

  • Kim, Ji-Hyoung;Kim, Sang-Woo;Heo, Junghwa;Nam, Jihyun;Kim, Man-Hae;Yu, Yung-Suk;Lim, Han-Chul;Lee, Chulkyu;Heo, Bok-Haeng;Yoon, Soon-Chang
    • Atmosphere
    • /
    • v.25 no.1
    • /
    • pp.185-191
    • /
    • 2015
  • Ambient measurements of aerosol light absorption (${\sigma}_a$) and scattering coefficients (${\sigma}_s$) were done at Gosan climate observatory during summer 2008 using a 3-wavelength photoacoustic soot spectrometer (PASS). PASS was deployed photoacoustic method for light absorption and integrated nephelometry for light scattering measurements. The ${\sigma}_a$ and ${\sigma}_s$ from PASS were compared with those from co-located aethalometer and nephelometer measurements. The aethalometer measurements of ${\sigma}_a$ correlated reasonably well with photoacoustic measurements, but the slope of the linear fitting line indicated the PASS measurement values of ${\sigma}_a$ were larger by a factor of 1.53. The nephelometer measurement values of ${\sigma}_s$ correlated very well with PASS measurements of ${\sigma}_s$, with a slope of 1.12 and a small offset. Comparing to the aethalometer measurements, the photoacoustic measurements of ${\sigma}_a$ didn't exhibit a significant (i.e., the ratio between aethalometer and PASS increased) change with increasing relative humidity (RH). The ratio of ${\sigma}_s$ between nephelometer and PASS increased with increasing RH, especially when the RH increased beyond 80%. This apparent increase in ${\sigma}_s$ with RH may be due to the contribution of hygroscopic growth of aerosols.

Simple Model of Bright-room Contrast Ratio Measurement System for Plasma Display Panels with Contrast Enhancement Film

  • Beom, Tae-Won;Park, Gi-Chan;Park, Jong-Rak;Kim, Young-Sik;Zhang, Jun;Song, Bu-Seup;Chun, Jong-Pil;Yoon, Ki-Cheol;Jang, Won-Gun
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.38-43
    • /
    • 2011
  • We have developed a simple model of a bright-room contrast ratio (BRCR) measurement system for plasma display panels (PDPs) adopting a contrast enhancement film (CEF) by using an illumination design tool. Only four model parameters were used, namely, total ambient illumination power delivered by fluorescent lamps, a panel scattering rate, illuminance of PDP white patterns, and the absorption coefficient of a color adjusting film. These parameters were determined by simple optical measurements and matching simulations. The proposed model was employed to predict the BRCR values of four different CEF samples, and the simulated ones were found to be in agreement with measured ones within about 10% relative-error.