• Title/Summary/Keyword: absolute deviation

Search Result 329, Processing Time 0.022 seconds

Prediction of Autoignition Temperature of n-Propanol and n-Octane Mixture (n-Propanol과 n-Octane 혼합물의 최소자연발화온도의 예측)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.2
    • /
    • pp.21-27
    • /
    • 2013
  • The lowest values of the AITs(Autoignition temperatures) in the literature were normally used fire and explosion protection. In this study, the AITs of n-Propanol+n-Octane system were measured from ignition delay time(time lag) by using ASTM E659 apparatus. The AITs of n-Propanol and n-Octane which constituted binary systems were $435^{\circ}C$ and $218^{\circ}C$, respectively. The experimental ignition delay time of n-Propanol+n-Octane system were a good agreement with the calculated ignition delay time by the proposed equations with a few A.A.D.(average absolute deviation).

A Multiobjective Process Planning of Flexible Assembly Systems with Evolutionary Algorithms (진화알고리듬을 이용한 유연조립시스템의 다목적 공정계획)

  • Shin, Kyoung Seok;Kim, Yeo Keun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.31 no.3
    • /
    • pp.180-193
    • /
    • 2005
  • This paper deals with a multiobjective process planning problem of flexible assembly systems(FASs). The FAS planning problem addressed in this paper is an integrated one of the assignment of assembly tasks to stations and the determination of assembly routing, while satisfying precedence relations among the tasks and flexibility capacity for each station. In this research, we consider two objectives: minimizing transfer time of the products among stations and absolute deviation of workstation workload(ADWW). We place emphasis on finding a set of diverse near Pareto or true Pareto optimal solutions. To achieve this, we present a new multiobjective coevolutionary algorithm for the integrated problem here, named a multiobjective symbiotic evolutionary algorithm(MOSEA). The structure of the algorithm and the strategies of evolution are devised in this paper to enhance the search ability. Extensive computational experiments are carried out to demonstrate the performance of the proposed algorithm. The experimental results show that the proposed algorithm is a promising method for the integrated and multiobjective problem.

Measurement and Prediction of Autoignition Temperature(AIT) of n-Propanol and Acetic acid System (노말프로판올과 아세틱에씨드 계의 최소자연발화온도(AIT) 측정 및 예측)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.66-71
    • /
    • 2017
  • The autoignition temperature (AIT) is crucial combustible characteristics which need attention in chemical process that handle hazardous materials. The AIT, also to as minimum spontaneous ignition temperature(MSIT), is the lowest temperature of a hot surface at which the substance will spontaneously ignite without any obvious sources of ignition such as a spark or flame. The AIT may be used as combustion property to specify operating, storage, and materials handling procedures for process safety. This study measured the AITs of n-propanol+acetic acid system from ignition delay time(time lag) by using ASTM E659 apparatus. The AITs of n-propanol and acetic acid which constituted binary system were $435^{\circ}C$ and $212^{\circ}C$, respectively. The experimental AITs of n-propanol+acetic acid system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D.(average absolute deviation). In the case of n-propanol and acetic acid system, the minimum autoignition temperature behavior (MAITB), which is lower than the lower AIT, is shown among the two pure substances constituting the mixture.

Smoothing Output Power Variations of Isolated Utility Connected Multiple PV Systems by Coordinated Control

  • Datta, Manoj;Senjyu, Tomonobu;Yona, Atsushi;Sekine, Hideomi;Funabashi, Toshihisa
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.320-333
    • /
    • 2009
  • A Photovoltaic (PV) system's power output varies with the change of climate. Frequency deviations, tie line voltage swings are caused by the varying PV power when large PV power from several PV systems is fed in the utility. In this paper, to overcome these problems, a simple coordinated control method for smoothing the variations of combined PV power from multiple PV systems is proposed. Here, output power command is formed in two steps: central and local. Fuzzy control is used to produce the central smoothing output power command considering insolation, variance of insolation and absolute average of frequency deviation. In local step, a simple coordination is kept between the central power command and the local power commands by producing a common tuning factor. Power converters are used to achieve the same output power as local command power employing PI control law for each of the PV generation systems. The proposed method is compared with the method where conventional Maximum Power Point Tracking (MPPT) control is used for each of the PV systems. Simulation results show that the proposed method is effective for smoothing the output power variations and feasible to reduce the frequency deviations of the power utility.

A Study on the Change and Characteristics of Stereotyped Japanese Elementary School in Meiji Era - Focusing on the Standard Drawings by Japanese Ministry of Education - (명치기(明治期) 일본(日本) 소학교건축(小學校建築)의 표준화 과정 및 특성에 관한 연구 - 문부성 제정 표준도 분석을 중심으로 -)

  • Lee, Jeong-Woo;Shim, Woo-Gab
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.15 no.2
    • /
    • pp.27-38
    • /
    • 2008
  • This study aims to examine Japanese elementary school architecture in Meiji Era, in which Japanese modern education system was settled down and the school architecture flourished by mass construction of stereotyped school buildings. It is assumed that stereotyped school architecture is due to the influence of the standard drawings made by Japanese Ministry of Education, therefore standard drawings could be a key to understand the characteristics of the stereotyped school buildings in Meiji Era. In this perspective this study attempts to analyze 4 standard drawings and interpret it in relation to regulations and design guidelines for school architecture in that time. As results of this study the change and characteristics of stereotyped school architecture in Meiji Era are clarified in several categories. They are as follows : the deviation of classroom and corridor, the change of classroom size fixing to 4 kan(間) by 5 kan(間), the absolute use of north-lacing single corridor type block-plan, and the change of other space such as waiting room(控所), special instruction room, auditorium and gymnasium.

Thermal System Analysis to Optimize Torch Position in The Core Making Machine. (중자조형기의 토치위치 최적화를 위한 열계해석)

  • Han, Geun-Jo;Ahn, Sung-Chan;Shim, Jae-Joon;Han, Dong-Seop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.1
    • /
    • pp.43-47
    • /
    • 2002
  • The new core making method economizing the amount of core sand has been requested. The new method is that a core box is heated until it reaches reasonable temperature and then core sand with core binder is sprayed into the core box. Since inner temperature distribution have to be uniform in order to form uniform thickness of core, we studied inner temperature distribution of core box. First, we determined proper number of torches and optimized torch positions to minimize the average of absolute deviation(AVEDEV) of inner temperature. The results are as fellowed: 1. The number of torches that enables uniform inner temperature distribution about $300^{\circ}C$ is 25. 2. When $S_H$ and $S_V$ is 0.7, the torch positions are optimized and AVEDEV is 5.85.

Prediction of Autoignition Temperature of n-Decane and sec-Butanol Mixture (n-Decane과 sec-Butanol 혼합물의 최소자연발화온도의 예측)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.85-90
    • /
    • 2012
  • The autoignition temperature (AIT) of a material is the lowest temperature at which the material will spontaneously ignite. The AIT is important index for the safe handling of flammable liquids which constitute the solvent mixtures. This study measured the AITs of n-Decane+sec-Butanol system by using ASTM E659 apparatus. The AITs of n-Decane and sec-Butanol which constituted binary system were $212^{\circ}C$ and $447^{\circ}C$, respectively. The experimental AITs of n-Decane+sec-Butanol system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D. (average absolute deviation).

Measurement of Autoignition Temperature of Ethylbenzene+n-hexanol and Ethylbenzene+n-propionic Acid Systems (Ethylbenzene+n-hexanol 계와 ethylbenzene+n-propionic acid계의 최소자연발화온도의 측정)

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.33-40
    • /
    • 2007
  • The values of the AITs(Autoignition temperatures) for fire and explosion protection are normally the lowest reported. This study measured the AITs of ethylbenzene+n-hexanol and ethylbenzene+n-propionic acid Systems from ignition delay time(time lag) by using ASTM E659-78 apparatus. The AITs of ethylbenzene, n-hexanol and n-propionic acid which constituted binary systems were $475^{\circ}C,\;275^{\circ}C\;and\;511^{\circ}C$, respectively. The experimental ignition delay time of ethylbenzene+n-hexanol and ethylbenzene+n-propionic acid systems were a good agreement with the calculated ignition delay time by the proposed equations with a few A.A.D.(average absolute deviation).

Outcome of Open Reduction Via Retromandibular Approach for Mandibular Subcondyle Fracture (하악골 과두경부 골절에 있어서 후하악부 절개법을 이용한 관혈적 정복술의 유용성)

  • Lee, Hyung Chul;Kang, Dong Hee;Koo, Sang Hwan;Park, Seung Ha
    • Archives of Plastic Surgery
    • /
    • v.32 no.6
    • /
    • pp.739-743
    • /
    • 2005
  • Subcondylar fractures have generally been treated by intermaxillary fixation except in cases where there is an absolute indication for open reduction. The reason behind a less aggressive surgical approach lies on the inherent difficulties in manipulating fragments in such a small area at the risk of damaging facial nerves or vessels such as the internal maxillary artery. However, long-term follow-up studies showed that conservative treatment of subcondylar fractures results in disturbances of occlusal function, deviation of the mandible, internal derangement of the temporomandibular joint, and ankylosis of the joint. We carried out open reduction of dislocated subcondylar fractures in 14 patients from 2000 to 2004 by a retromandibular approach. After the reduction of fractured bone, two H-shaped miniplates with 6 holes were fixed with screws at the anterior and posterior surfaces of the subcondyle. The retromandibular approach allowed good access and easy manipulation of the subcondyle. Immediate relief from malocclusion and correction of mandibular midline shifting were observed in all patients. Late temporomandibular dysfunction and ankylosis were not observed. Open reduction with plate osteosynthesis made it possible to avoid IMF in 7 of the 14 patients. The present study shows that open reduction through this retromandibular approach can produce good outcome in adult patients with subcondylar fracture.

Evaluation of C50 in Elementary School Classrooms (초등학교 교실의 C50 실태 평가)

  • Lee, Seong-Bok;Kim, Myung-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.888-892
    • /
    • 2014
  • This paper evaluates $C_{50}$ in elementary school classrooms and considers utilization of $C_{50}$ as an assessment indicator of acoustic performance. $C_{50}$ is early-to-late arriving sound ratio, recent study reported that $C_{50}$ is more appropriate as a measure of clarity and speech intelligibility than D50 because it is linearly related to subjective responses. The average of $C_{50}$ in elementary school classrooms appeared to be about +2 dB ~ +3 dB throughout 500 Hz ~ 4 kHz. However, absolute evaluation is difficult because there is no suitable reference or standard yet. As deviation of $C_{50}$ according to location is larger than reverberation time, it is expected that $C_{50}$ will be more sensitive when someone assesses acoustic performance of classrooms. Correlation between $C_{50}$ and reverberation time is very high. From logarithmic regression equation, we can estimate appropriate range of $C_{50}$ in elementary school classrooms indirectly, using standard of reverberation time in ANSI.

  • PDF