• 제목/요약/키워드: abrasive flow rate

검색결과 38건 처리시간 0.024초

An Experimental Investigation on the Contamination Sensitivity of an Automotive Fuel Pump

  • Lee Jae-Cheon;Shin Hyun-Myng
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제6권3호
    • /
    • pp.51-55
    • /
    • 2005
  • This study addresses the contamination sensitivity test of a typical fuel pump for an automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of a fuel pump on specific contaminant particle sizes so that an optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of the fuel pump is measured under the experiments of various contaminants size ranges of ISO test dust up to $80\;{\mu}m$. The fundamental theory of contamination sensitivity is introduced and the contamination sensitivity coefficients are estimated using the experimental data. Maximum contamination sensitivity coefficient of $5\chi\;10^{-6}\;L/min{\cdot}Ea$ is found in the contaminant size range of $40\;{\mu}m\~50\;{\mu}m$. The magnified picture of the surface of vane disc reveals that the abrasive wear is the principal cause of discharge flow rate degradation. Hence, this study reveals that a high efficiency filter for contaminant particles especially in the size range of $30\;{\mu}m\~70\;{\mu}m$ especially should be used to maintain the service life of the fuel filter.

자동차 연료펌프의 오염민감도 실험 연구 (An Experimental Investigation on The Contamination Sensitivity of An Automotive Fuel Pump)

  • 이재천;장지현;신현명
    • 한국정밀공학회지
    • /
    • 제21권6호
    • /
    • pp.102-108
    • /
    • 2004
  • This study addresses the contamination sensitivity test of a typical fuel pump for automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of fuel pump on specific contaminant particle sizes so that optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of fuel pump was measured under the experiments of various contaminants size ranges of ISO test dust up to 80${\mu}{\textrm}{m}$. The fundamental theory of contamination sensitivity was introduced and the contamination sensitivity coefficients were estimated using the experimental data. Maximum contamination sensitivity coefficient of $5{\times}10^{-6}$ L/minㆍEa was found on the contaminant size range of 40${\mu}{\textrm}{m}$∼50${\mu}{\textrm}{m}$. The magnified picture of the surface of vane disc revealed that the abrasive wear was the principal cause of discharge flow rate degradation. Hence, this study revealed that high efficiency filter on the contaminant particle size range of 30${\mu}{\textrm}{m}$∼70${\mu}{\textrm}{m}$ especially should be used to maintain the service lift of the fuel filter.

Sr 페라이트의 총형연삭특성 (Form grinding characteristics of Sr ferrite)

  • 김성청;이재우
    • 한국정밀공학회지
    • /
    • 제14권3호
    • /
    • pp.21-27
    • /
    • 1997
  • This paper aims to clarify the effects of grinding conditions in form grinding of Sr-ferrite with the electro-plated diamond wheel. The main conclusions obtained were as follows. (1) The flexural strength and surface roughness of ferrite became the best at the peripheral wheel speed of 1700 m/min. (2) In the case of the depth of cut larger than 0.4mm, crack layers is induced in the ground surface, and the fracture type of chips exhibits slight ductile mode in the depth of cut smaller than 0.2mm. (3) Whe the depth of cut exceeds 0.6mm, the wheel life becomes extremely severe due to the large chipping and brack- age in the diamond grains. However, at the depth of cut .leq. 0.05mm, the diamond grain shows abrasive wear. (4) The decrease of flexural strength and the increase of surface roughness is in proportion to the increase of the feed rate. (5) Most effective nozzle setting angles with various delivery conditions of the grinding fluid, such as nozzle position .PHI. , flow rate Q, etc., were made clear.

  • PDF

연속식 현미 조질기 개발 (Development of a Continuous Type Brown Rice Conditioning Equipment)

  • 송대빈;고학균
    • Journal of Biosystems Engineering
    • /
    • 제25권6호
    • /
    • pp.503-510
    • /
    • 2000
  • To improve the milling condition of brown rice a continuous type conditioning equipment was developed. To validate the performance of this machine the experimental operation was done at Sa-cheon RPC(Rice Processing Complex) using short grain rough. The initial moisture contents of brown rice were 15.0∼16.5%(w.b) and the flow rate of brown rice passing through the conditioner were 4,370kg per hour. The moisture content differences of brown rice between conditioned and non-conditioned were showed within 0.5%(w.b) This results means that the water injected to brown rice were absorbed to the surface of brown rice evenly. The moisture contents of conditioned treated milled rice were showed slightly higher than that of non-conditioned ones but it was considered that the conditioning process did not affected the weight increasing of milled rice by water supply. For initial moisture contents of 15.0∼16.5%(wb) brown rice it was found that the proper water supply rate was 0.115(cc-water)/(kg·%-brown rice) and the increments of whole rice were 2.2% compared to the non-conditioned ones. it was considered that the conditioning process did not influenced the whiteness of milled rice because the whiteness differences between conditioned and non-conditioned milled rice were negligible. About 18% of electric power which drives the abrasive type rice milling machine was saved at 0.115(cc-water)/(kg·%-brown rice) of water supply rate.

  • PDF

Separation of PET and PS with Air Separation

  • Nakazawa, Hiroshi;Kudo, Yasuo;Sato, Hayato
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.727-729
    • /
    • 2001
  • The air separation of PET (Polyethylene terephthalate) and PS(Polystyrene) was carried out by taking advantage of the different abrasive resistance of two plastics. PET bottles and PS packages were shredded to small square pieces $(5{\times}5mm)$. Both plastic shreds were treated by a shear-type crusher. The PET shreds were bent and twisted by the crush so that they were blown up easily, but the PS shreds were not. After the crush of mixture of both plastics, air separation experiments were carried out using four types of air separators. The number and location of the baffle attached to them are different. With the separator with a baffle attached at the upper part, PET recoveries for the crushing time of 30, 60 and 90sec were 67, 98 and 99% respectably at the air flow rate of 3.5m/s, whereas PS recoveries were null regardless of the crushing time.

  • PDF

Corrosive Wear of Alloy 690 Tubes in Alkaline Water

  • Hong, Seung Mo;Jang, Changheui;Kim, In Sup
    • Corrosion Science and Technology
    • /
    • 제8권3호
    • /
    • pp.126-131
    • /
    • 2009
  • The interaction between wear and corrosion can significantly increase total material losses in water chemistry environment. The corrosive wear tests of a PWR steam generator tube material (Alloy 690) against the anti vibration bar material (409 SS) were performed at room temperature. The tests were performed in alkaline water chemistry conditions. NaOH solution was selected for test condition to investigate the corrosive wear effect of steam generator tube material in alkaline pH condition without other factors. The flow induced vibration can caused tube damage and the corrosion can be occurred by water chemistry. The test results showed that, in the alkaline solution at pH 13.9, the corrosion current density was increased about ten times than that in the distilled water. And wear rate at pH 13.9 was increased about ten times from that at neutral condition. However, the wear rate was decreased with time. The decrease would be attributed to the change in roughness of specimen or sub-layer of the worn surface with time. From microstructure observation, severe abrasive shape and several wear debris were found. From those results, it could infer that the oxide film on Alloy 690 changed to easily breakable one in the alkaline water, and then abrasion with corrosion became the main wear mechanism.

미립분사가공을 이용한 유리 소재의 가속도 센서 구조물 성형 (Fabrication of the Acceleration Sensor Body of Glass by Powder Blasting)

  • 박동삼;강대규;김정근
    • 한국정밀공학회지
    • /
    • 제23권2호
    • /
    • pp.146-153
    • /
    • 2006
  • Acceleration sensors have widely been used in the various fields of industry. In recent years, micromachining accelerometers have been developed and commercialized by the micromachining technique or MEMS technique. Typical structure of such sensors consist of a cantilever beam and a vibrating mass fabricated on Si wafers using etching. This study investigates the feasibility of powder blasting technique for microfabrication of sensor structures made of the pyrex glass alternating the existing Si based acceleration sensor. First, as preliminary experiment, effect of blasting pressure, mass flow rate of abrasive and no. of nozzle scanning on erosion depth of pyrex and soda lime glass is studied. Then the optimal blasting conditions are chosen for pyrex sensor. Structure dimensions of designed glass sensor are 2.9mm and 0.7mm for the cantilever beam length and width and 1.7mm for the side of square mass. Mask material is from aluminium sheet of 0.5mm in thickness. Machining results showed that tolerance errors of basic dimensions of glass sensor ranged from 3um in minimum to 20um in maximum. This results imply the powder blasting can be applied for micromachining of glass acceleration sensors alternating the exiting Si based sensors.

Chemical mechanical planarization 슬러리에 사용되는 point-of-use 필터의 평가 방법 개발 (Development of point-of-use filter evaluation method using chemical mechanical planarization slurry)

  • 장선재;아툴 쿨르카르니;김형우;김태성
    • 한국입자에어로졸학회지
    • /
    • 제12권4호
    • /
    • pp.145-150
    • /
    • 2016
  • During the chemical mechanical planarization (CMP) process, slurry that comprises abrasive particles can directly affect the CMP performance and quality. Mainly, the large particles in the slurry can generate the defects on the wafer. Thus, many kinds of filters have been used in the CMP process to remove unwanted over-sized particles. Among these filters, the point-of-use (POU) filter is used just before the slurry is supplied onto the CMP pad. In the CMP research field, analysis of the POU filter has been relatively exceptional, and previous studies have not focused on the standardized filtration efficiency (FE) or filter performance. Furthermore, conventional evaluation methods of filter performance are not appropriate for POU filters, as the POU filter is not a membrane type, but is instead a depth type roll filter. In order to accurately evaluate the POU filter, slurry FE according to particle size was measured in this study. Additionally, a CMP experiment was conducted with filtered slurry to demonstrate the effects of filtered slurry on CMP performance. Depending on the flow rate and the filter retention size, the FE according to particle size was different. When the small and large particles have different FEs, the total filtration efficiency (TFE) can still have a similar value. For this reason, there is a need to measure the FE with respect to the particle size to verify the effects of the POU filter on the CMP process.