• 제목/요약/키워드: abrasion resistance

검색결과 469건 처리시간 0.036초

생불활성 질화물 이온도금된 티타늄 임프란트의 표면특성 및 생체적합성 (Surface characteristics and biocompatibility of bioinert nitrides ion plated titanium implant)

  • 장갑성;김흥중;박주철;김병옥;한경윤
    • Journal of Periodontal and Implant Science
    • /
    • 제29권1호
    • /
    • pp.209-231
    • /
    • 1999
  • Even though titanium(Ti) and its alloys are the most used dental implant materials, there are some problems that Ti wears easily and interferes normal osteogenesis due to the metal ions. Ti coated with bioactive ceramics such as hydroxyapatite has also such problems as the exfoliation or resorption of the coated layer, Recent studies on implant materials have been proceeding to improve physical properties of the implant substrate and biocompatibility of the implant surfaces. The purpose of the present study was to examine the physical property and bone tissue compatibility of bioinert nitrides ion plated Ti, Button type specimens(14mm in diameter, 2.32rrun in height) for the abrasion test and cytotoxicity test and thread type implants(3.75mm in diameter, 6mm in length) for the animal experiments were made from Ti(grade 2) and 316LVM stainless steel. Ti specimens were ion plated with TiN, ZrN by the low temperature arc vapor deposition, and the depth profile of the TiN/Ti, ZrN/Ti ion plated surface was examined by Auger Electron Spectroscopy. Three kind of button type specimens .of TiN/Ti, ZrN/Ti and Ti were used for abrasion test, and HEPAlClC7 cells and CCD cells were cultivated for 4 days with the specimens for cytotoxicity test. Thread type implants of TiN/Ti, ZrN/Ti, Ti, 316LVM were implanted on the femur of 6 adult dogs weighing 10kg-13kg. Two dogs were sacrified for histological examination after 45 days and 90 days, and four dogs were sacrified for the removal torque test of the implant') after 90 days. The removal torque force was measured by Autograph (Shimadzu Co., AGS-1000D series, Japan). Abrasion resistance of TiN/Ti was the highest, and that of ZrN/Ti and Ti were followed. The bioinert nitride ion plated Ti had much better abrasion resistance, compared with Ti, In the cytotoxicity test, the number of both cells were increased in all specimens, and there were no significant difference in cytotoxic reaction among all groups (p>0.1), In histological examination, 316LVM showed the soft tissue engagement in interface between the implant and bone, but the other materials after 45 days noted immature new bone formation in the medullary portion along the implant surface, and those after 90 days showed implant support by new bone formation in both the cortical and the medullary portion, The removal torque force of Tilv/Ti showed significantly higher than that of Ti(p(O,05). The difference in removal torque force between TiN/Ti and ZrN/Ti was not significant(p>0.05), and that of 316LVM was lowest among all groups(p<0.05). These results suggest that bioinert nitrides ion plated Ti can resolve the existing problems of Ti and bioactive ceramics, and it may be clinically applicable to human.

  • PDF

불소도포제에 의한 치면열구전색제의 마모저항성과 표면 변화에 관한 실험연구 (Experimental Research on the Surface Changes and the Abrasion Resistance of Pit and Fissure Sealant by Fluoride)

  • 황수현;유지수
    • 치위생과학회지
    • /
    • 제10권5호
    • /
    • pp.373-378
    • /
    • 2010
  • 불소도포와 치면열구전색은 치아우식을 예방하기 위한 목적으로 임상에서 널리 병용하여 사용되고 있지만, 불소가 치면열구전색제의 표면 구조를 변화시켜 미생물이 서식할 조건을 마련하여 수복물의 수명을 단축시키는 원인이 될 수 있다. 이에 본 연구에서는 현재 치과 임상에서 많이 사용되고 있는 레진계 실란트 Concise와 Eco-S를 사용하였고, 대표적인 불소도포제재 1.23% APF gel과 5% NaF Fluoride Varnish가 치면열구전색제의 표면 구조에 미치는 영향을 평가하기 위해 제작된 치면열구전색제시편을 각각 5군으로 불소제재를 처리하지 않은 I군, APF gel 1분간 처리한 II군, APF gel 4분간 처리한 III군, Fluoride Varnish 1분간 처리한 IV군, Fluoride Varnish 4분간 처리한 V군으로 분류하여 마모실험에 의한 무게변화를 측정하였고, 광학현미경을 이용하여 표면구조를 관찰하여 다음과 같은 결론을 얻었다. 1. 치면열구전색제 Concise를 이용한 마모실험에서 불소제재를 처리하지 않은 I군에 비하여 APF gel 4분간 처리한 III군에 무게 감소가 증가하였으며, Fluoride Varnish 4분간 처리한 V군에서 무게 감소가 적으며(p<0.05), Eco-S를 이용한 마모실험 결과 또한 같았다(p<0.05). 2. 광학현미경으로 표면의 변화를 관찰한 결과 APF gel을 도포한 경우 기질의 소실로 필러가 두드러진 양상을 보였으며, 각 군 별로는 APF gel 4분간 처리한 III군, APF gel 1분간 처리한 II군, 불소제재를 처리하지 않은 I군, Fluoride Varnish 1분간 처리한 IV군, Fluoride Varnish 4분간 처리한 Ⅴ군의 순으로 표면 거칠기가 감소되는 결과를 보였다. 결론적으로, 치면열구전색과 불소도포를 당일 시행하는 경우, 불소도포제를 1.23% APF gel 사용 시 4분 보다 1분 도포하며, 1.23% APF gel보다는 5% NaF Fluoride Varnish 도포하는 것이 치면열구전색제의 표면 구조에 영향을 줄일 수 있다고 사료된다.

H-NBR/NBR 블렌드의 열노화거동 (Thermal Aging Behavior of H-NBR/NBR Blend)

  • 최원석;김건완;도제성;유명우;류승훈
    • Elastomers and Composites
    • /
    • 제46권2호
    • /
    • pp.132-137
    • /
    • 2011
  • 본 연구는 H-NBR 함량 변화에 따른 H-NBR/NBR 블렌드의 열노화 거동에 대하여 살펴보았다. 이 때 가교제로는 dicumyl peroxide와 황 혼합물을 사용하였으며, 열노화에 따른 H-NBR/NBR 블렌드의 인장강도, 파괴신율, 경도 그리고 내마모성의 변화를 살펴보았다. H-NBR을 첨가함에 따라 인장강도는 증가하였으나 내마모성은 감소하는 현상을 나타내었다. 파괴신율과 경도는 H-NBR의 영향을 받지 않았다. 노화가 진행된 모든 시편은 초기 시편보다 낮은 인장강도, 파괴신율, 경도를 나타내었다. 그러나 H-NBR의 함량이 증가함에 따라 이러한 물성저하 속도가 감소함을 알 수 있었다. 즉 H-NBR 첨가에의해 열노화 특성이 향상됨을 알 수 있었다. 모든 NBR/H-NBR 블렌드는 노화시간이 증가함에 따라 내마모성이 감소하였으며, H-NBR을 첨가한 경우 내마모성의 저하가 상대적으로 낮음을 알 수 있었다.

낙엽송 마루판재의 표면강화처리기술개발(I) (Development of Surface Improvement Technique of Japanese Larch flooring Board(I))

  • 박상범
    • Journal of the Korean Wood Science and Technology
    • /
    • 제27권3호
    • /
    • pp.31-38
    • /
    • 1999
  • 본 연구는 재면이 약한 낙엽송재의 교실용 마루판으로의 재질개량의 일환으로 경도와 내마모성 등 표면성능의 개선을 도모하기 위한 표면강화처리기술을 개발하기 위하여 수행되었다. 낙엽송 마루판의 밑칠을 폴리우레탄 우드실러, 중간칠을 폴리우레탄 샌딩실러도료로 도장한 다음, 마감칠로써 자외선 (UV) 경화형 에폭시아크릴레이트수지도료와 우레탄아크릴레이트수지도료를 이용한 표면강화처리에 의해 경도, 내마모성, 부착성, 내충격성이 향상되었다. 이 처리에 의해 브리넬경도가 1.75에서 2.25~2.27로 개선되어 2.38의 참나무재와 유사한 경도치를 나타내었으며, 약 2배의 내마모성 증대효과가 나타났다. 외부충격에 의한 도막의 갈라짐은 거의 발생하지 않았으며, 에폭시아크릴레이트가 우레탄아크릴레이트에 비해 충격에 의한 크랙의 발생율이 적었다.

  • PDF

합금크롬주철의 탄화물형상 및 열처리가 내마모성에 미치는 영향 (Effects of Carbide Morphology and Heat Treatment on Abrasion Wear Resistance of Chromium White Cast Irons)

  • Yu, Sung-Kon;Matsubara, Yasuhiro
    • 한국재료학회지
    • /
    • 제12권5호
    • /
    • pp.407-413
    • /
    • 2002
  • Eutectic high chromium cast irons containing 17%Cr and 26%Cr were produced for this research by making each of them solidify unidirectionally. Abrasion wear test against SiC or $Al_2$O$_3$bonded paper was carried out using test pieces cut cross-sectionally at several distances from the chill face of castings. The wear resistance was evaluated in connection with the parameters such as eutectic colony size($E_w$), area fraction of boundary region of the colony($S_B$) where comparatively large massive chromium carbides are crystallized and, average diameter of chromium carbides in the boundary region($D_c$). The wear rate($R_w$), which is a gradient of straight line of wear loss versus testing time, was influenced by the type and the particle size of the abrasives. The $R_w$ value against SiC was found to be larger than that against A1$_2$O$_3$under the similar abrasive particle size. In the case of SiC, the $R_w$ value increased with an increase in the particle size. The $R_w$ value also increased as the eutectic colony size decreased, and that of the 17%Cr iron was larger than that of the 26%Cr iron at the same $E_w$ value. Both of the $S_B$ and $D_c$ values were closely related to the $R_w$ value regardless of chromium content of the specimens. The $R_w$ values of the annealed specimens were greater than those of the as-cast specimens because of softened matrix structures. As for the relationship between wear rate and macro-hardness of the specimens, the hardness resulting in the minimum wear rate was found to be at 550 HV30.

페놀 변성 폴리아민계 내오존도료를 이용한 고도정수처리장의 방수$\cdot$방식 공법에 대한 현장 적용성 평가에 관한 연구 (A study on the evaluation of field application for the waterproofing or corrosion proof construction method, as coating high quality filtration plant with ozone resistance paints of phenol degeneration polyamine)

  • 정문정;권시원;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 추계 학술논문 발표대회
    • /
    • pp.33-38
    • /
    • 2005
  • It is applied in the high quality equipment construction by introduction of this high duality treating technology (ozone treating, activated carbon treating, high quality oxidation treating, UV treating etc.)waterproofing or corrosion proof method caused secondary economy damage of operation discontinuance and high quality treating equipment for applying existent waterproofing method that corrosion proof ability (ozone resistance performance, chemical resistance etc.) and abrasion resistance performance by comprehension insufficiency of user and designer. Therefor, In this study, we will analyze problem of waterproofing and corrosion material of existing construction application by high quality treating, and measure physical performance change by various condition. It is required to waterproofing and corrosion system and application of the field valuation.

  • PDF

PTFE 및 W 첨가가 Ni-P 도금의 내마모 특성에 미치는 영향 (Effects of PTFE and W Addition on the Anti-Wear Properties of Ni-P Coatings)

  • 김명식;홍진원;배규식
    • 반도체디스플레이기술학회지
    • /
    • 제6권2호
    • /
    • pp.25-28
    • /
    • 2007
  • Electroless Ni-P coating is widely used for chemical, electronic, and semiconductor equipment parts because of its corrosion resistance. The incorporation of chemically-inert PTFE particles into the Ni-P films improves properties such as, non-stick, anti-adhesive and better corrosion resistance. However, soft PTFE particles degrade the hardness, wear and abrasion resistance. In this study, effects of PTFE and W addition to the Ni-P-coatings were compared by the XRD, SEM, sheet resistance, contact angle, and microhardness measurements. The change in sheet resistance was negligible, but contact angle was doubled by the addition of PTFE and W. The microhardness was lower for Ni-P-PTFE, but higher for Ni-P-PTFE-W coatings, compared to that of Ni-P coatings.

  • PDF

무전해 Ni-P-X(X : $Al_2O_3$, Diamond) 복합도금층의 내마모성 (A Wear Resistance of Electroless Ni-P-X(X : $Al_2O_3$, Diamond) Composite Coating Layers)

  • 김만;장도연;노병호;한성호;이규환
    • 연구논문집
    • /
    • 통권22호
    • /
    • pp.151-160
    • /
    • 1992
  • The wear resistance of electroless Ni-P-X(X A1203, Diamond) composite coating layers was studied by Taber abrasion test technique. The wear resistance of composite coating layers was particularly relied upon the codeposited content, particle size and distribution of particles, and heat treatment of coating layers, as well as the electroless nickel plating bath employed. In this study, we lay emphasis on the wear resistance of electroless composite coating layers containing A1203 particles(1.2~Im, 6.7hIm, 11.5lIm, 20l1m) or diamond particles (1.5jim, 5gm). From the result of composite coating A1203 and diamond particles, the wear resistance of composite coating layers is as follows.

  • PDF