Statement of problem: The esthetic component of dental care has become increasingly more important, while new tooth-colored materials are continually marketed. Various new indirect composite materials have been developed with required advantages. The most recent development in the indirect composites has been the introduction of the second-generation laboratory composite or poly-glass materials. They are processed by different laboratory techniques based on combinations of heat, pressure, vacuum and light polymerization. Although, second generation products became available in 1995, their characteristics and clinical performance have not been adequately investigated. Purpose: The aim of this study was to measure the mechanical properties of the second generation indirect resin system and compare these with an existing universal direct composite resin. Material and method: In this study four indirect composite material (Adoro LC, BelleGlass HP, Tescera, Synfony) were tested for flexural strength, wear resistance, hardness and their degree of conversion against Z250, a light cure direct composite. Results: Within the limitations of this study, the following conclusions were drawn: 1. From the abrasion wear result, Adoro showed the least volume loss while Synfony showed the greatest volume loss. Z250 and BelleGlass HP didn't show significant difference (p>0.05), but they showed significant difference with other groups (p<0.05). From the attrition wear, BelleGlass HP showed the least volume loss and it didn’t show significant difference with Tescera (p>0.05). While Synfony showed the greatest volume loss that it showed significant difference with other groups (p>0.05). 2. Mean values of flexural strength by means of three point bending test was in the order of Z250, Adoro, Belleglass HP, Tescera and Synfony. Mean elastic modulus was in the order of Z250, BelleGlass HP, Tescera, Adoro and Synfony. 3. The result of Vicker‘s microhardness value showed that significantly higher value in Z250 (p<0.05), and is in the order of BelleGlass HP, Tescera, Adoro and Synfony. 4. The degree of conversion measured by FT-IR showed significantly higher value in BelleGlass HP (p<0.05), and is in the order of Adoro, Synfony, Tescera and Z250. Conclusion: Significant differences were found in the flexural strength, wear resistance, hardness and their degree of conversion.
작은 굴절률 및 높은 굴절률을 갖는 저 분산 렌즈에 대한 요구가 증가함에 따라, 높은 내열성 및 내마모성을 갖는 이형성 보호 필름에 대한 필요성이 증가하고 있다. 그러나 광학 산업은 비구면 유리 렌즈 성형에 사용되는 이형보호 필름의 제조 공정 및 품질 표준에 대한 명확한 표준을 아직 확립하지 못했다. 이 기술은 광학 렌즈를 제조하는 각 회사의 노하우로 취급된다. 본 연구에서는 FCVA (Filtered Cathode Vacuum Arc) 기반 ta-C 박막 코팅의 이온에칭, 각 소스 및 필터부의 마그네트론 및 아크 전류, 바이어스 전압의 최적화에 관한 실험을 수행하였다. 그 결과, 코팅성능 측면에서, 이리듐- 레늄 합금 박막 스퍼터링 제품 대비 필름 두께가 약 50% 얇고, 경도는 약 20%, 박막의 접착강도는 약 40 % 개선된 것으로 측정되었다. 본 연구의 박막 코팅 공정 결과는 금형 이형 박막층의 최소 기계적 특성 및 품질 확립을 위한 유리 렌즈의 개발 및 활용에 크게 기여할 것으로 사료된다.
목적: 본 연구의 목적은 air-blasting particle size를 달리하고 분사 압력과 시간을 통상보다 크게 증가시켜 표면에 큰 손상을 유발한 군을 상대적으로 작은 손상을 유발한 군과 비교하여 파절 저항과 접착 강도 차이를 보이는지 평가하는 데 있다. 연구 재료 및 방법: 지르코니아($LAVA^{TM}$) 디스크 표면에 각각 $30{\mu}m$- particle size (Cojet) 2.8 bar 15초, $110{\mu}m$- (Rocatec) 2.8 bar 15초, $110{\mu}m$- (Rocatec) 3.8 bar 30초로 조건을 달리하여 표면처리 후 각각 이축 굽힘하중 강도 실험과 접착 파절 하중 실험을 실행하였다. 접착은 상아질 유사 베이스에 $200{\mu}m$ 두께의 레진시멘트로 시행하여 인장력을 극대화하였으며 음향방출(AE) 센서로 실패하중을 검출하였다. 결과: 이축 굽힘하중 강도, 접착 파절하중은 세 군간 서로 유의성 있는 차이를 보이지 않았다(P > 0.05). 접착 시편의 균열은 대부분 radial crack이었다. 결론: 정하중 평가의 한계 내에서, air-blasting particle size와 압력에 의한 표면 손상은 크지 않았으며, 접착 파절하중 평가는 표면 손상과 접착 강도를 동시에 평가할 수 있는 방법이라 여겨진다.
본 연구에서는 최근 치과임상에서 이용되고 있는 7종의 복합레진을 시험재료로 선택한 다음 법랑질과 복합레진 충전재가 대합하는 경우의 마모 양상을 조사하기 위해 광중합형 복합레진과 제2소구치 교두를 핀-디스크 구동 방식의 전동식 마모시험기에 고정한 다음 68.6N의 하중을 가한 상태에서 30,000회전시켜 $1.3{\times}10^3m$의 미끄럼 접촉을 가하였다. 마모도를 평가하기 위해 복합레진의 종류에 따른 제2소구치 교두의 수직고경 변화, 시편의 두께 감소와 체적 손실 및 마모시험 전후의 표면을 주사전자현미경으로 관찰하였고, 표면경도가 마모도에 미치는 영향을 평가하기 위해 누프 경도를 측정한 결과, 다음과 같은 결론을 얻었다. 1. 누프 경도는 Spectrum 군에서 70.4로 가장 높고 Heliomolar 군에서 19.8로 가장 낮은 값을 보였으며, Tukey 다중범위검증법에 의해서 각 군 사이의 통계적 유의성을 검증한 결과, Spectrum 군, Z100 군 및 Clearfil AP-X 군을 제외한 나머지 모든 군들 사이에서 상호간에 통계학적으로 유의한 차이를 보였다(p<0.05). 2. 법랑질의 내마모성은 microfill 형인 Heliomolar 군과 대합하는 경우에 가장 높게 나타났으며, 구치부용에서는 구상의 zirconia silica 미세 입자를 복합화한 micro hybrid 형의 Palpique 군에서 가장 높게 나타났다. 3. 복합레진의 연마성 마모에 대한 저항성은 필러의 평균 입경이 작고 미세 필러를 고밀도로 분산시켜 복합화한 hybrid 형 복합레진에서 높게 나타나는 경향을 보였다. 4. 주사전자현미경 관찰 결과, 마모면에서는 필러의 돌출, 마멸과 탈락 및 기질레진의 미세 균열 진전과 표면층의 박리 등이 관찰되었다.
1970 년대 이후, 우레탄 도막방수공법은 자외선에 강하고 탄성 및 수밀성이 뛰어나 지붕 및 지하바닥, 스포츠경기장 등에 널리 활용되고 있다. 그러나 옥상 및 지하공간은 미끄럼으로 인한 위험이 많고 다양한 외력으로 하자발생이 빈번하여, 미끄럼방지기능 및 내구성을 향상시켜야 하고 사용자의 편의성 및 심미적 측면의 기능성을 고려한 우레탄 도막방수공법의 개발이 절실하다. 따라서 기존 우레탄의 장점을 유지하고 성능 및 기능을 향상시킨 다양한 공법이 개발되고 있으며, 최근에 엠보스프레이 코팅시스템(Embo spray coating system)을 활용한 엠보탄(Embo-thane) 도막방수공법이 개발되었다. 본 논문은 엠보탄 도막방수공법의 노출 비노출 바닥재에 대하여 살펴보고 기존의 우레탄 도막방수공법과의 성능 및 기능에 대한 객관적 비교 분석을 실시하기 위하여 인장강도, 신장률, 부착성능, 내마모성, 미끄럼저항성능에 대한 실험적 연구를 실시하였다. 그리고 엠보탄 방수공법의 물리적 성능뿐만 아니라 공법의 설계적 측면을 고려한 평가기준항목 설정과, AHP(Analytic Hierarchy Process)기법을 활용한 VE(Value Engineering)분석을 실시하여, 엠보탄 도막방수공법이 기존의 우레탄 도막방수공법에 비교하여 성능 및 기능에 대한 개선정도를 성능점수(performance index)를 통하여 제시하였다. 또한, 불확실성이 고려된 결과에 대한 평가를 위하여 Monte Carlo Simulation기법을 활용하여 확률적 접근방법을 통한 신뢰도 분석을 실시하고자한다.
복합레진은 치질과 우수한 결합력을 가지며 심미적인 이유로 치과의 대표적 수복재로 자리잡고 있다. 그러나 저작력에 따른 마모와 구강내 환경에서의 수분흡수에 따른 가수분해가 복합레진의 강도약화를 야기하고 있다. 실험에 사용된 복합레진은 현재 임상에서 많이 사용되고 있는 Point4, Tetric flow, Heliomolar flow, Filtek supreme 이다. 각 제품의 화학적 분해와 마모도를 평가하기 위해 각각 10개의 시편을 제작하여 그 중 5개는 $37^{\circ}C$의 수중하에 1Kg의 하중을 가하여 10,000 cycle동안의 마모도를 측정하였다. 나머지 5개 시편은 무게 측정을 한 후 0.1N NaOH용액, 3ml에 저장하여 $60^{\circ}C$에서 보관한 후 2주 후 제거하여 1.23% HCl로 2시간 동안 중화하고 증류수로 세척한 후 $60^{\circ}C$에서 건조하였다. 무게 손실, 분해층 깊이 및 시편내의 Si의 농도 변화. 최대 마모 깊이를 근거로 평가하여 다음과 같은 결과를 얻었다. 1. 각 제품의 무게 손실량은 Heliomolar flow, Filtek supreme, Point4, Tetric flow 순이었으며 Heliomolar flow, Filtek supreme을 제외한 다른 제품간에는 유의한 차이를 보였다(P<0.05). 2. 각 제품의 표면하 분해층 깊이는 Filtek supreme, Heliomolar flow, Tetric flow, Point4 순이었으며 Heliomolar flow, Tetric flow을 제외한 다른 제품간에는 유의 한 차이를 보였다(P<0.05). 3. 각 제품으로부터 용출된 Si은 Filtek supreme, Heliomolar flow, Point4. Tetric flow 순이었으며 Point4, Tetric flow을 제외 한 다른 제품간에는 유의한 차이를 보였다(P<0.05). 4. 최대마모깊이 측정시 Heliomolar flow, Point4, Filtek supreme, Tetric flow 순이며 0.1N NaOH 용액에 보관한 레진의 마모깊이가 물에 보관한 레진에 비해 증가한 양상을 보였다. 5. 주사전자현미경 관찰시 NaOH 용액에 보관한 후 레진 기질과 충전제 사이의 결합의 파괴를 관찰할 수 있었으며, 공촛점 레이저 현미경 관찰시 NaOH 용액에 보관한 후 수복재의 기질과 충전제 사이의 파괴양상인 분해층 깊이를 관찰할 수 있었다.
폴리머 콘크리트는 일반 콘크리트에 비해 경화시간이 짧고, 압축, 인장, 휨, 부착강도, 마찰저항성, 마모감량 등이 우수해 건축 재료로써 폭넓은 활용이 기대되는데, 특히, 레진 바인더와 골재만의 결합으로 이루어진 폴리머 콘크리트는 진동 감쇠 성능이 우수하여, 다양한 보강재로의 활용과 관련한 연구가 진행되고 있다. 한편, 이러한 폴리머 콘크리트가 일반 콘크리트 및 일반 방진보강재를 완전히 대체하기 위해서는 물리적 특성, 동적 특성, 생산성 및 현장 적용성 등을 고려한 진동저감 성능에 대한 전반적인 검토가 필요한 실정이다. 본 연구에서는 폴리머 콘크리트의 에폭시 혼입비율별 물리적, 동적 특성을 일반 콘크리트와 비교한 결과, 압축, 인장, 휨, 부착강도가 상당히 우수한 결과를 보였으며, 특히 인장강도는 4~6.5배 이상 큰 차이를 보였다. 폴리머 콘크리트의 기본적인 물리적 특성에 근거하여 폴리머 콘크리트의 일반적인 사용성에 대해 검토함과 동시에, 에폭시 혼입비율에 따른 동적 특성인 감쇠비를 해석 모델과 실험을 통해 도출하여 검토한 결과, 폴리머 콘크리트의 동적 강성은 일반 콘크리트의 동적 강성 보다 20% 높고, 손실률은 약 3배 정도 높은 것으로 나타났다.
The indirect technique for making cast restoration requires that dies be as accurate and durable as possible. Currently, stone is the most commonly used material for die. However, it has some problems such as the weakness in its strength and low abrasion resistance. Recently, epoxy resin die systems have become available. The purpose of this study was to examine two commercially available resin die systems and evaluate some characteristics for their clinical performance. This study evaluated the dimensional accuracy of epoxy resins and their wettability with impression materials. In this study, the first experiment was about dimensional accuracy of different die materials. The master model was made of stainless steel. 10 models were made of two epoxy resins (Die-epoxy, Tri-epoxy) and a die stone (Fujirock) each. Occlusal diameter (Dimension I), occluso-gingival height (Dimension II), and interabutment distance (Dimension III) were measured in each model. Next, the contact angles of die materials with impression materials were observed. The blocks were made of polyether, hydrophilic additional silicone, polysulfide impression materials. By drop-ping the same amount (0.05ml) of Tri-epoxy, Die-epoxy, and die stone on the blocks, 10 samples of each die material were made. After setting of materials, the contact angles were measured. The results of this study were as follows. 1. The expansion of stone die and the shrinkage of resin dies in occlusal diameter were observed, and stone and Tri-epoxy were expanded and Die-epoxy was shrinked in occluso-gingival height. There was little change among materials in interabutment distance (p<0.05). 2. In comparison with the master model Tri-epoxy had the least variation in measurement of the three die systems examined. Die-epoxy was next, and die stone showed the greatest variation. 3. The compatibility of die stone for polyether, hydrophilic additional silicone, polysulfide decreased in order, wherease epoxy materials had the decreased compatibility for polyether and polysulnde, hydrophilic additional silicone in order. It was not statistically different between polyether and polysulfide (p<0.05). 4. The contact angles of Tri-epoxy, Die-epoxy, die stone were getting bigger in order.
전투차량의 연료탱크에 설치되어 엔진으로 연료를 이송하는 장치인 전기식 연료펌프에 대하여 고장분석과 내열성능 평가가 수행되었다. 고장의 원인을 파악하기 위하여 직류 전동기가 적용된 연료펌프를 분해하여 검사를 수행하였다. 하우징 내부를 관찰한 결과를 바탕으로 고장 현상을 권선 소손, 브러시 조기 마모, 연료 혼입의 세 가지로 분류하였다. 연료펌프 내부 검사를 실시한 결과를 바탕으로, 과열에 의한 권선 소손을 고장을 발생시킨 주된 원인으로 추정하였다. 이에 따라서 전기식 연료펌프의 권선이 과열로 소손될 가능성을 확인하기 위하여 온도 센서를 고정자 표면과 브러시 홀더에 설치한 후 무부하 조건으로 24시간동안 가동을 실시하였다. 연료펌프의 주변 온도를 68 ℃로 설정하였을 때 고정자 온도는 최대 135.9 ℃까지 상승하였으며, 전동기의 고정자 및 회전자 권선이 소손되었다. 이 결과를 통해서 전기식 연료펌프를 위한 전동기 권선의 내열성능이 부족함을 확인할 수 있었으며, 이를 해결하기 위하여 현재 155 ℃ 이하에서 사용할 수 있는 절연등급 F종의 권선 및 함침액을 180 ℃ 이상에서도 사용할 수 있는 C종 이상의 절연등급으로 대체하도록 제안하였다.
$Si_3N_4$와 Ti 또는 TiAl 합금을 $900^{\circ}C$에서 확산쌍을 제조하여 분석하고, 확산층의 분석을 통하여 생성된 층마다의 조성을 분석하여 각 원소들의 확산 경로 및 속도를 비교 하였다. $Si_3N_4/Ti$의 확산 쌍의 확산 경로는 $Si_3N_4/Ti_5Si_3+TiN/TiN/Ti$로 나타났고, Ti 측면에서 TiN층이 생성 되었음으로 N의 확산 속도가 Si 보다 빠름을 알 수 있었다. $Si_3N_4/TiAl$ 합금의 확산쌍은 $Si_3N_4/Ti$ 사이의 확산쌍과는 다르게 Si, N, Ti, Al 의 각 원소 마다의 확산 속도 차이로 인하여 확산 경로는 $Si_3N_4/TiN(Al)/Ti_3Al/TiAl$ 상으로 나타났다. 상태도를 통하여 생성된 확산쌍의 확산경로를 파악한 결과, 확산경로의 요구사항을 모두 만족하였다. $Si_3N_4/Ti$ 확산에서 Ti를 이용한 적분확산 계수는 $Ti_5Si_3$, TiN에서 $2.18{\times}10^{-16}m^2/sec$, $2.19{\times}10^{-16}m^2/sec$, $Si_3N_4/TiAl$ 확산 쌍에서 Ti를 이용한 적분확산 계수는 각각 TiN(Al) 상에서 $2.88{\times}10^{-16}m^2/sec$, $Ti_3Al$ 상에서 $1.48{\times}10^{-15}m^2/sec$으로 나타났다. 본 연구는 $Si_3N_4$와 Ti 및 TiAl의 계면 반응을 분석한 결과로서 $Si_3N_4$ 상을 이용한 확산반응의 기초자료로 사용될 수 있을 것으로 사료된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.