• 제목/요약/키워드: abrasion

검색결과 1,213건 처리시간 0.03초

극지 운항 선박 Ice Belt Zone의 도장 사양 설계 연구 (A Study on Coating Performance Design for Ice Belt Zone of the Arctic Vessels)

  • 백윤호;박충서;소용신
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2013년도 특별논문집
    • /
    • pp.66-72
    • /
    • 2013
  • The demand for an ice class ship is rising expected to rise according to the increase of energy consumption and the opening of arctic sea routes. Ice class ship should be designed to cope with the severe environmental conditions of arctic sea such as a high mechanical impact and abrasion damage, caused by pack ice, ice bergs and low temperature. The ice class ship hulls are coated with an anti-abrasion and low friction coating such as a solvent free epoxy or high solid-volume epoxy. These coatings require two-component heating pump and a high grade surface preparation. In this study, the coating performances for the arctic vessels, such as puncture absorbed energy, abrasive wear loss, friction coefficients and impact absorbed energy were evaluated. Based on this study, a proper coating performance specification for the arctic vessels was proposed and coating selection guideline in terms of coating performance and workability was also established.

  • PDF

A comparison of different gingival depigmentation techniques: ablation by erbium:yttrium-aluminum-garnet laser and abrasion by rotary instruments

  • Lee, Kwang-Myung;Lee, Dong-Yeol;Shin, Seung-Il;Kwon, Young-Hyuk;Chung, Jong-Hyuk;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • 제41권4호
    • /
    • pp.201-207
    • /
    • 2011
  • Purpose: The aim of this study is to compare two different gingival depigmentation techniques using an erbium:yttrium-aluminum-garnet (Er:YAG) laser and rotary instruments. Methods: Two patients with melanin pigmentation of gingiva were treated with different gingival depigmentation techniques. Ablation of the gingiva by Er:YAG laser was performed on the right side, and abrasion with a rotary round bur on the opposite side. Results: The patients were satisfied with the esthetically significant improvement with each method. However, some pigment still remained on the marginal gingival and papilla. The visual analog scale did not yield much difference between the two methods, with slightly more pain on the Er:YAG laser treated site. Conclusions: The results of these cases suggest that ablation of the gingiva by an Er:YAG laser and abrasion with a rotary round bur is good enough to achieve esthetic satisfaction and fair wound healing without infection or severe pain. Prudent care about the gingival condition, such as the gingival thickness and degree of pigmentation along with appropriate assessment is needed in ablation by the Er:YAG laser procedure.

Potassium oxalate와 Sodium fluoride의 상아질 지각과민 억제효과 (THE EFFECTIVENESS OF POTASSIUM OXALATE AND SODIUM FLUOIRIDE ON THE REDUCTION OF DENTINAL HYPERSENSITIVITY)

  • 서민수;박동수;정창모
    • Restorative Dentistry and Endodontics
    • /
    • 제16권1호
    • /
    • pp.216-225
    • /
    • 1991
  • The purpose of this study was to evaluate the desensitizing effect of potassium oxalate(Group I), sodium fluoride (Group II), and control group (Group III). The 120 teeth of 26 patients who had been complained dentinal hypersensitivity were divided into three groups by applicating agent. The observation was done before and immediately after treatment. The data were statistically analyzed and the results were as followed. 1. Potassium oxalate showed the best desensitizing effect to the stimuli, followed by sodium fluoride, control group, and there was a significant difference (p<0.05) in desensitizing effect among the groups. 2. Potassium oxalate showed the best desensitizing effect to the stimuli, followed by sodium fluride, control group on both cervical abrasion and gingival recession, and there was a significant difference (p<0.05) in desensitizing effect among the groups on both cervical abrasion and gingival recession. 3. There was no significant difference (p<0.05) in effect of the desensitization between cervical abrasion and gingival recession. 4. The scratch and air blast I were more effective in desensitiziation than other stimuli with significant difference (p<0.05). In view of the results mentioned above, it can be conceived that potassium oxalate is more effective than sodium fluoride on the reduction of dentinal hypersensitivity.

  • PDF

고크롬 백주철의 미세조직과 기계적 특성에 미치는 초기응고 조직의 영향 (Effect of Primarily Solidified Structure on the Microstructure and the Mechanical Properties of High Cr White Iron)

  • 조현욱;도정현;조원제;정현득;이재현;조창용
    • 한국주조공학회지
    • /
    • 제35권6호
    • /
    • pp.178-184
    • /
    • 2015
  • Due to excellent abrasion resistance the high-chrome white irons are widely used in mining and mineral industries. Minor variation of carbon content in 28% chrome white iron resulted in difference in primarily solidified microstructure. Sub-eutectic (hypoeutectic) composition led to formation of primarily solidified dendrites. Formation of primarily solidified dendrites which were supersaturated with carbon and chrome also caused precipitation of fine secondary carbides that are different from relatively large plate type $M_7C_3$ carbides in the eutectic structure. Small portion of primarily solidified dendrite expected to contribute significantly to the improvement of abrasion resistance of the white iron because the dendrites provided mechanical support to carbides. The relative fraction of primary dendrite increased with reduction of carbon content from the eutectic composition. The increased fraction of primary dendrite increased hardness value of the white irons.

스탬핑 리드프레임의 버와 잔류응력 제거를 위한 전해연마의 적용 (The Application of Electropolishing for Removing Burrs and Residual Stress of Stamping Leadframe)

  • 신영의;김헌희;김경섭;코조후지모토;김종민
    • 마이크로전자및패키징학회지
    • /
    • 제8권3호
    • /
    • pp.19-24
    • /
    • 2001
  • 반도체 패키지에 사용되는 주요 재료인 리드프레임은 반도체 제품의 소형화, 박형화, 고집적 화에 대응하기 위해서 리드 및 피치의 미세화가 요구되며 제조 과정에서 발생되는 버(burr)의 제거와 잔류응력 제거에 대한 노력이 필요하다. 본 논문은 리드프레임의 제작 시 스탬핑 공정 중에 발생하는 버와 잔류응력을 제거하기 위해 전해연마를 적용하였다. 전해연마를 적용한 리드프레임은 표면의 버 등이 제거되었으며, 잔류음력은 실험에 사용된 전해액의 종류에 따라 차이가 있으나, 과염소산계의 경우에는 잔류응력을 23%제거하여 리드프레임의 신뢰성을 높일 수 있었다.

  • PDF

-금속(金屬) 표면처리방법(表面處理方法)에 따른 비귀금속합금(非貴金屬合金)과 도재(陶材)와의 결합강도(結合强度)에 관(關)한 실험적(實驗的) 연구(硏究)- (An Experimental study on the bond strength according to the surface treatment of metal alloy for porcelain fused metal crown)

  • 정인성
    • 대한치과기공학회지
    • /
    • 제11권1호
    • /
    • pp.83-88
    • /
    • 1989
  • This investigation was performed to evaluate the effect of four different preteatment techniques on the bond strength of porcelain to non-precious metal alloy. Samples of total of 40 were divided into 4 groups according to the 4 variables which included the 50$\mu$alumina oxide air abrasion, method, the as retention bead method, the L-retention bead method, the Etching method. The completed metal-porcelain samples were compressed in Instron loading machine until gross fracture occured to examine the effect of the complex variables on the bond strength of porcelain to non precious metal alloy. The result obtained were as follows : 1. The difference of bond strength according to four different pretreatment techniques was statistically significant(p<0.01). 2. The difference of bond strength between the ss-retention bead method and the L-retention bead method was not significant statistically(p>0.05) 3. The difference of bond strength between the retention bead method and the etching method was statistically significant(p<0.01). 4. The difference of bond strength between the retention bead method and the 50$\mu$alumina oxide air abrasion method was statistically significant(p<0.01). 5. The difference of bond strength between the etching method and the 50$\mu$alumina oxide air abrasion method was statistically significant(p<0.01).

  • PDF

치경부 마모병소의 상아질 표면처리 방식에 따른 상아질과 접착제 간의 계면 양상 (INTERFACIAL MORPHOLOGY BETWEEN DENTIN AND ADHESIVES ACCORDING TO TREATMENT OF DENTIN SURFACE OF CERVICAL ABRASION LESION)

  • 이용희;이희주;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제26권1호
    • /
    • pp.51-63
    • /
    • 2001
  • In order to know the effect of dentin bonding agents on the restoration of cervical abrasion, Scotchbond Multipurpose Single Bond and Clearfil Liner Bond 2 were used in 51 teeth with abrasion lesion and normal teeth. The surface structure and dentinal tubules of acid etched dentin and resin replica were examined using scanning electron microscopy. The interfacial morphology between dentin and adhesives was investigated by confocal laser scanning microscopy. Following results were obtained. 1. The hybrid layer and resin tag of the dentin showing cross-sectional surface of dentinal tubules are thicker and longer than those of dentin showing oblique surface of dentinal tubules. 2. The sclerotic cast was frequently observed in dentinal tubule, and the cast looked like cuboidal or rhomboidal-shaped crystals clumped from outer side to inner side. 3. The formation of hybrid layer and resin tag was the most prominent in Scotchbond Multipurpose group, whereas Clearfil Liner Bond 2 group showed very poor formation. The formation of hybrid layer and resin tag in Single Bond group was less than Scotchbond Multipurpose group.

  • PDF

라식수술을 시행한 환자에서 결막절개를 통한 하안검성형술 시 발생한 각막손상 (Corneal Abrasion Occurred during Transconjunctival Blepharoplasty in a Patient with History of LASIK Operation)

  • 신종인;권인오;김창연
    • Archives of Plastic Surgery
    • /
    • 제38권4호
    • /
    • pp.543-546
    • /
    • 2011
  • Purpose: LASIK, one of the currently popular ophthalmic procedures, can sometimes result in dry eye symptoms. In the patient who had underwent LASIK operation, the periorbital surgery may be more likely to lead to such a complication as dry eye symptom. We would like to report a case of corneal abrasion occurred after transconjunctival blepharoplasty in post-LASIK state and suggest the method about preventing the complication. Methods: A 30-year-old female patient underwent transconjunctival blepharoplasty and microfat graft into the face. She had history of LASIK operation 2 years ago. Corneal protector was applied to both eye during transconjunctival operation. After the surgery, she complained of visual blurring at left side. Ophthalmic examination revealed corneal abrasion of left eye. Results: Cornea protecting lens was applied to left eye for 2 weeks. Steroid and antibiotic eye drops were applied for relieving the symptoms and the prevention from progressing of complication. After 1 week, visual power and acuity was recovered to preoperative state. No other specific complications happened. Conclusion: Post-LASIK patient may have possibility of decreased corneal sensation and tear production. Preoperative ophthalmic examination is recommended for the prevention of complication. When corneal protector is applied, we suggest Optagel$^{(R)}$ as a useful lubricant.

NBR계(系) 고무롤의 생성개질(物性改質)에 관(關)한 연구(硏究) (I) -NBR/PVC 혼합계(混合系) 고무- (A Study on Modification of NBR Rubber Roll (I) -NBR/PVC Blend Systems-)

  • 서관호;고영철;하현달;조을용
    • Elastomers and Composites
    • /
    • 제30권3호
    • /
    • pp.195-206
    • /
    • 1995
  • To modify the NBR rubber roll which has poor abrasion and chemical resistance, NBR/PVC blends were prepared in various composition ratios. First of all, their miscibility and vulcanization characteristics were investigated. Their abrasion and chemical resistant properties and physical properties were also studied. DSC thermograms for NBR/PVC blends show only one Tg in the entire composition range, demonstrating a perfect miscibility. In the vulcanization characteristics tested by rheometer, maximum torque decreases as PVC contents increased. In the investigation of physical properties of NBR/PVC blends, hardness increases and elongation decreases along with the increasing contents of PVC. On the other hands, tensile strength increases with the increasing contents of PVC up to 11.1 wt. %, and then decreases with higher contents of PVC. While the abrasion resistance of NBR/PVC blends was similar to that of NBR itself, the chemical resistance of NBR/PVC blends was superior to that of NBR.

  • PDF

클로로부틸 고무 함량이 클로로부틸 고무 블렌드물의 기계적 물성에 미치는 영향 (Effects of Chlorobutyl Rubber Content on the Mechanical Properties of Chlorobutyl Rubber Blends)

  • 박차철;표경덕
    • Elastomers and Composites
    • /
    • 제45권4호
    • /
    • pp.280-285
    • /
    • 2010
  • CIIR에 BR, SBR 및 NBR을 다양한 조성으로 혼합하여 블렌드물의 마찰계수와 내마모특성 및 물리적 특성 변화 등을 검토하였다. 영구압축줄음율 측정에서 블렌드비율 25%에서 가장 높은 값을 나타내어 변형에 대한 저항 특성이 가장 낮은 것으로 나타났다. SBR, NBR, BR이 CIIR에 블렌딩됨에 따라 블렌드물의 마찰계수는 산술평균적으로 저하하는 경향을 나타내었다. 마찰력 향상을 위하여 BR에 CIIR을 블렌딩하는 경우 마찰계수 증가에 의한 접지력 향상보다는 내마모 성능 저하에 의한 마이너스효과가 더욱 큰 것으로 나타났다.