• Title/Summary/Keyword: abnormal noise

Search Result 234, Processing Time 0.055 seconds

Noise Reduction of Traction Motor for High Speed Train (고속전철용 견인전동기 소음개선)

  • Kim, Jung-Chul;Kim, Dea-Kwang;Kim, Bong-Chul;Park, Yeong-Ho;Choi, Jong-Mook
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.95-100
    • /
    • 2007
  • The traction motor for High Speed Train is being required reliability and stability for high-speed operation. And also required low noise level, high performance, compact size owing to the space and weight limitation for attaching to train, etc. As a result of requiring the low noise level and high power capacity, it is adopted forced-air-ventilation insead of self-ventilation that is generally used on electric multiple unit. Traction motor is cooled by cooling air through the air-ventilation hole. When the traction motor is operated with forced-air-ventilation, there is some abnormal noise in the specific RPM. This paper is dealing with the method to reduce the resonance phenomena by adopting the rotor blade.

  • PDF

Improvement of Noise Characteristics in Super-RENS Disc (Super-RENS 디스크의 노이즈 특성 향상)

  • Kim, Joo-Ho;Hwang, In-Oh;Kim, Hyun-Ki;Park, In-Sik;Bae, Jae-Cheol
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.1
    • /
    • pp.48-52
    • /
    • 2005
  • The research topic of super-RENS technology is shifting from the signal intensity (CNR; Carrier to Noise Ratio) to the signal uniformity (Jitter or bER). To achieve an uniform signal characteristics, it is important to reduce signal fluctuation in a super-RENS disc. In this study, we investigated the relation between signal fluctuation and low frequency noise (LFN), and analyzed LFN increase in recording and readout processes. It was found that signal fluctuation had a close relationship with the LFN. Also, it was found that the recorded mark shape such a bubble type and high readout power increased the LFN in recording and readout process of a super-RENS disc. So, using non-bubble type recording material and low super-resolution readout material, we markedly improved the LFN in a super-RENS disc.

  • PDF

A Real Time QRS Detection Algorithm Based-on microcomputer (마이크로 컴퓨터를 이용한 실시간 QRS검출 앨고리즘)

  • 김형훈;이경중;이성환;이명호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.4
    • /
    • pp.127-135
    • /
    • 1986
  • This paper represents a real time algorithm which improves the some drawbacks in the past methods for detection of the QRS conplexes of ECG signals. In the conventional method we can't detect QRS complex and QRS duration more correctly in case of (1) the contaminated ECG with 60Hz noise, muscle noise. (2) the movement of the baseline for a QRS complex. (3) being abnormal QRS complex with prolonging QRS. Therefore, we have proposed a new algorithm which can detect accurate QRS complex detection in case of the contaminated ECG with 60Hz noise, muscle noise, and movement of baseline for QRS complex. Moreover, in case of prolonging QRS we accomplished to detect not only QRS complex but also a single pulse that has a width proportional to QRS duration. This algorithm which is proposed in our paper in our paper in programmed with 6502 assembly language for real time ECG signal processing.

  • PDF

A Study on the Spectrum Analyzing of Internal Leak in Valve for Power Plant Using Acoustic Emission Method (음향방출법에 의한 발전용 밸브내부 누설의 스펙트럼분석 연구)

  • Lee, Sang-Guk;Lee, Sun-Ki;Lee, Jun-Shin;Sohn, Seok-Man
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.694-699
    • /
    • 2004
  • The purpose of this study is to estimate the availability of acoustic emission method to the internal leak of the valves at nuclear power plants. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. From the comparison of the background noise data with the experimental results as to relation between leak flow and acoustic signal, the minimum leak flow rates that can be detected by acoustic signal was suggested. When the background levels are higher than the acoustic signal, the method described below was considered that the analysis the remainder among the background noise frequency spectrum and the acoustic signal spectrum become a very useful leak detection method. A few experimental examples of the spectrum analysis that varied the background noise characteristic were given.

  • PDF

Noise-Vibration Phenomenon inducing Propeller on the 55ft Class Sailing Yacht (55피트급 세일링 요트의 프로펠러 유기 소음·진동 현상)

  • Lee, Donchool;Kim, Hobin;Eam, Gitak
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.753-756
    • /
    • 2013
  • The demand for sailing yacht is increasing in consonance the improvement of people's live. These yachts can be dually propelled by wind and by diesel engine power. A singing (humming, whistling) phenomenon induced on the propeller was discovered on a 55-foot catamaran sailing yacht. As a result, an increase in the structural vibration of the stern tube room and propulsion system with abnormal noise was detected due to this flow. In this study, the cause of the phenomenon is investigated and its possible countermeasures proposed.

  • PDF

The Study on noise Analysis of Bush on Suspension System (현가계 부쉬 이상소음 분식에 관한 연구)

  • Bae, Chul-Yong;Lee, Dong-Won;Kim, Chan-Jung;Lee, Bong-Hyun;Na, Byung-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.69-74
    • /
    • 2006
  • It is known that the various noise sources which are engine, transmission, tire, intake system, etc exist at vehicle driving status. Specially noises which cannot be expected by a driver induce unpleasantness to all passengers. These noises are difficult to distinguish noise sources or specifications because of too many vehicle parts. Therefore in this paper, study on abnormal noise of bush on suspension system is performed by the measurement and analysis of the noises of bushings that are generated artificially. The measured noises are analyzed by two points-view of spectrum and sound quality. Finally, it is shown that the noise sources of bushings on the suspension system which are the pillow ball joint bush of a control arm and the rubber bush of a lower arm could be distinguished by the spectrum distribution and a index value based on tonality.

  • PDF

A study on the reduction of noise and vibration by acoustic resonance in the tube bank of a circulating fluidized bed combustion boiler (순환 유동층 보일러 관군의 음향공진에 의한 이상소음 발생 및 저감 연구)

  • Park, Eung-Kyu;Song, Keun-Bok;Kim, Won-Hyun;Joo, Won-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.101-106
    • /
    • 2011
  • In the present paper, the phenomena of abnormal noise and vibration due to acoustic resonance of CFBC(Circulating Fluidized Bed Combustion) boiler was presented. The acoustic resonance which occurred in the gas path of CFBC boiler system was caused by coincidence of vortex shedding frequency of tube bank and acoustic natural frequency of duct and hopper. And, the phenomena of beating arose from the interference of two closed resonant waves at 66.4Hz and 70.8Hz. There are two control methods for acoustic resonance in this system. The first method is to change the vortex shedding frequency from the structural alterations on the tube bank. And the second method is to change the acoustic natural frequency of the gas path with the installation of anti-noise baffles. The second one which is relatively easy to apply, was adapted in this study. As a result, the noise and vibration level have been decreased by 41dB and 94% at 66.4Hz, respectively. And the improvement of noise and vibration at 70.8Hz was identified by sensory evaluation.

  • PDF

Vibration Reducing Method for High Pressure Feedwater Heater Drain Piping System (고압급수가열기 배수계통 배관계 고진동 해소방안 연구)

  • Lee, Wook-Ryun;Lee, Jun-Shin;Kim, Sang-Bok;Hong, Soon-Bup;Shin, Yong-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1290-1295
    • /
    • 2006
  • The 120 meters high pressure feedwater heater drain piping in nuclear power plant had been suffered by excessive vibration from the beginning of power generation. As time goes by, the piping vibration was beyond the allowable limit and an appropriate countermeasure was required to prevent the fatigue failure of the pipeline from the abnormal vibration. In this study, the vibrational characteristics of high pressure feedwater heater drain piping and the countermeasure for abnormal vibration were investigated. Among the several vibration reduction methods, the piping layout changed by making the smooth pipeline was applied to the high Pressure feedwater heater drain piping in nuclear Power plant. Applying the countermeasure, the vibration level was found to reduce over 54 percents and was satisfied under the allowable velocity at the full-power operation condition.

  • PDF

Combustion Condition Monitoring of the Marine Diesel Engine using Acceleration Signal of Cylinder Head (실린더 헤더의 가속도 신호를 이용한 선박용 디젤엔진의 연소 상태 모니터링)

  • Seo, Jong-Cheol;Kim, Sang-Hwan;Lee, Don-Chool
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.607-610
    • /
    • 2009
  • The abnormal combustion in the running engine results to knocking which increases the pressure and temperature in the cylinder, thereby decreasing the generated power by reducing the thermal efficiency. When the temperature and pressure in the cylinder increased rapidly by knocking, abnormal combustion takes place and the engine power is decreased. To investigate the knocking phenomenon, accelerometers are installed in the cylinder head to monitor and diagnose the vibration signal. As method of signal analysis, the time-frequency analysis method was adapted for acquisition of vibration signal and analyzes engine combustion in the short time. In this experiment, after analyzing time data which is stored in the signal recorder in one unit work (4 strokes: 2 revolutions), the signal with frequency and Wavelet methods with extracted one engine combustion data was also analyzed. Then, normal condition with no knocking signal is analyzed at this time. Hereafter, the experiments made a standard for distinguishing normal and abnormal condition to be carried out in acquisition of vibration signal at all cylinders and extracting knocking signal. In addition, analyzing methods can be diverse with Symmetry Dot Patterns (SDP), Time Synchronous Average (TSA), Wigner-Ville Distribution (WVD), Wigner-Ville Spectrum (WVS) and Mean Instantaneous Power (MIP) in the cold test [2]. With signal processing of vibration from engine knocking sensor, the authors adapted a part of engine /rotor vibration analysis and monitoring system for marine vessels to prevent several problems due to engine knocking

  • PDF

Sound Quality evaluation of the interior noise for the driving vehicle using Mahalanobis Distance (Mahalanobis Distance 를 이용한 주행중 차량 실내소음의 음질평가)

  • Park, Sang-Gil;Kim, Ho-San;Bae, Chul-Yong;Lee, Bong-Hyun;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.318-321
    • /
    • 2007
  • Since human listening is very sensitive to sound, a subjective index of a sound quality is required. Therefore, in the analysis for each situation, the sound evaluation is composed with sound quality factor. Many researchers spends their effort to make a more reliable and more accurate of sound in term of sound quality index for various system noise. The previous methods to evaluation of the SQ about vehicle interior noise are linear regression analysis of subjective SQ metrics by statistics and the estimation of the subjective SQ values by neural network. But these are so depended on jury test very much that they result in many difficulties. So, to reduce jury test weight, we suggested a new method using Mahalanobis distance for SQ evaluation. Threrefore, in this study Mahalanobis distance for the vehicle interior noise was derived using the objective SQ except jury test. Finnaly, the results of the SQ evaluation was analyzed discrimination between reference and abnormal group.

  • PDF